相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
A significant improvement in blood velocity estimation accuracy can be achieved by simultaneously processing both temporal and spatial information obtained from a sample volume. Use of the spatial information becomes especially important when the temporal resolution is limited. By using a two-dimensional sequence of spatially sampled Doppler signal "snapshots" an improved estimate of the Doppler correlation matrix can be formed. Processing Doppler data in this fashion addresses the range-velocity spread nature of the distributed red blood cell target, leading to a significant reduction in spectral speckle. Principal component spectral analysis of the "snapshot" correlation matrix is shown to lead to a new and robust Doppler mode frequency estimator. By processing only the dominant subspace of the Doppler correlation matrix, the Cramer-Rao bounds on the estimation error of target velocity is significantly reduced in comparison to traditional narrowband blood velocity estimation methods and achieves almost the same local accuracy as a wideband estimator. A time-domain solution is given for the velocity estimate using the root-MUSIC algorithm, which makes the new estimator attractive for real-time implementation.  相似文献   

3.
Transducer design and phased array beam steering are developed for a volumetric ultrasound scanner that enables the 3-D visualization of dynamic structures in real time. The authors describe the design considerations and preliminary evaluation of a high-speed, online volumetric ultrasound imaging system that uses the principles of pulse-echo, phased array scanning with a 2-D array transducer. Several 2-D array designs are analyzed for resolution and main lobe-side lobe ratio by simulation using 2-D fast Fourier transform methods. Fabrication techniques are described for 2-D array transducer. Experimental measurements of pulse-echo point spread responses for 2-D arrays agree with the simulations. Measurements of pulse-echo sensitivity, bandwidth, and crosstalk are included  相似文献   

4.
We present a cost-effective portable ultrasound system based on a single field-programmable gate array (FPGA) for point-of-care applications. In the portable ultrasound system developed, all the ultrasound signal and image processing modules, including an effective 32-channel receive beamformer with pseudo-dynamic focusing, are embedded in an FPGA chip. For overall system control, a mobile processor running Linux at 667 MHz is used. The scan-converted ultrasound image data from the FPGA are directly transferred to the system controller via external direct memory access without a video processing unit. The potable ultrasound system developed can provide real-time B-mode imaging with a maximum frame rate of 30, and it has a battery life of approximately 1.5 h. These results indicate that the single FPGA-based portable ultrasound system developed is able to meet the processing requirements in medical ultrasound imaging while providing improved flexibility for adapting to emerging POC applications.  相似文献   

5.
A major design problem concerning high-frequency broad-band ultrasound imaging systems is caused by the strong dispersive attenuation of the tissue, which gives rise to images with inhomogeneous resolution and poor signal to noise ratio (SNR). To address the noise problem, strongly focused transducers with high energy density in a narrow focal region are utilized, which also provide more isotropic images due to improved lateral resolution. To account for the short depth of the focal area two suitable imaging conceptions are used: 1) synthetic aperture concept and 2) B/D-scan concept. To avoid the inhomogeneity of the images, different transmitter signals for each depth are applied, which are pseudoinversely prefiltered according to the transfer function of the tissue. To gain signal energy required for inverse filtering, a pulse compression technique with nonlinearly frequency modulated chirp signals is utilized. These procedures have been implemented in an ultrasound imaging system, which has been developed in the authors' laboratory for eye and skin examinations, It can be used with transducers in a frequency range from 20 to 250 MHz.  相似文献   

6.
This is Part I of a series of two papers describing the development of a digital high-frequency, annular-array, ultrasonic imaging system. In this paper, the design and fabrication of a high-frequency annular array as well as its performance will be reported. A six-element, 50 MHz array, which incorporated an acoustic lens to provide an initial focal point, was designed and fabricated. A submicron size grain lead titanate piezoelectric ceramic was used to both reduce lateral coupling and keep the electrical impedance matched close to the 50 ohm receive electronics. The array elements were isolated using laser micromachining to fully separate the annuli, and electrical interconnection was achieved by directly soldering thin wires to the elements. The resulting array attained an average impulse response that exhibited a 43 MHz center frequency, 30% relative bandwidth, and an average insertion loss of 31 dB at 45 MHz. Maximum next-element crosstalk was -27 dB in water.  相似文献   

7.
High-resolution clinical systems operating near 15 MHz are becoming more available; however, they lack sensitive harmonic imaging modes for ultrasound contrast agent (UCA) detection, primarily due to limited bandwidth. When an UCA is driven to nonlinear oscillation, a very wideband acoustic transient response is produced that extends beyond 15 MHz. We propose a novel strategy using two separate transducers at widely separated frequencies and arranged confocally to simultaneously excite and receive acoustic transients from UCAs. Experiments were performed to demonstrate that this new mode shows similar resolution, higher echo amplitudes, and greatly reduced attenuation compared to transmission at a higher frequency, and superior resolution compared to transmission and reception at a lower frequency. The proposed method is shown to resolve two 200 microm tubes with centers separated by 400 microm. Strong acoustic transients were detected for rarefaction-first 1-cycle pulses with peak-negative pressures above 300 kPa. The results of this work may lead to uses in flow and/or targeted imaging in applications requiring very high sensitivity to contrast agents.  相似文献   

8.
For pt.I see ibid., vol.38, no.2, p.100-8 (1991). The authors describe the design, application, and evaluation of parallel processing to the high-speed volumetric ultrasound imaging system. The scanner produces images analogous to an optical camera or the human eye and supplies more information than conventional sonograms. Potential medical applications include improved anatomic visualization, tumor localization, and better assessment of cardiac function. The system uses pulse-echo phased array principles to steer a 2-D array transducer of 289 elements in a pyramidal scan format. Parallel processing in the receive mode produces 4992 scan lines at a rate of approximately 8 frames/s. Echo data for the scanned volume is presented online as projection images with depth perspective, stereoscopic pairs, or multiple tomographic images. The authors also describe the techniques developed for the online display of volumetric images on a conventional CRT oscilloscope and show preliminary volumetric images for each display mode.  相似文献   

9.
For pt.I see ibid., vol.45, no.4, pp.939-54 (1998). The statistical performance of the new 2-D narrowband time-domain root-MUSIC blood velocity estimator described previously is evaluated using both simulated and flow phantom wideband (50% fractional bandwidth) ultrasonic data. Comparisons are made with the standard 1-D Kasai estimator and two other wideband strategies: the time domain correlator and the wideband point maximum likelihood estimator. A special case of the root-MUSIC, the "spatial" Kasai, is also considered. Simulation and flow phantom results indicate that the root-MUSIC blood velocity estimator displays a superior ability to reconstruct spatial blood velocity information under a wide range of operating conditions. The root-MUSIC mode velocity estimator can be extended to effectively remove the clutter component from the sample volume data. A bimodal velocity estimator is formed by processing the signal subspace spanned by the eigenvectors corresponding to the two largest eigenvalues of the Doppler correlation matrix. To test this scheme, in vivo common carotid flow complex Doppler data was obtained from a commercially available color flow imaging system. Velocity estimates were made using a reduced form of this data corresponding to higher frame rates. The extended root-MUSIC approach was found to produce superior results when compared to both 1- and 2-D Kasai-type estimators that used initialized clutter filters. The results obtained using simulated, flow phantom, and in vivo data suggest that increased sensitivity as well as effective clutter suppression can be achieved using the root-MUSIC technique, and this may be particularly important for wideband high frame rate imaging applications.  相似文献   

10.
An external ultrasound oscillating probe has been developed for the purpose of visualizing dynamically the left cardiac ventricle three-dimensional (3D) movements and deformations. The fundamental principle of this probe is to maintain in continuous oscillation a classical one-dimensional (1D) transducer array around its axis at a maximum oscillation rate of 3 degrees per millisecond. A global medical system, including hardware elements and a software package, has been designed for this application. A motorization set and electronic boards enable this new oscillating probe to be used with any recent echograph equipped with a cardiac module and an external triggering cineloop. Moreover, in order to obtain 3D/4D left ventricle movements from a set of 2D recorded images, a rendering method based on the 2D discrete Fourier transform is applied. Promising preliminary results have been obtained on some patients, and a clinical study on a great number of subjects (both healthy and heart complaint people) was carried out.  相似文献   

11.
Ultrasound tomography has considerable potential as a means of breast cancer detection because it reduces the operator-dependency observed in echography. A half-ring transducer array was designed based on breast anatomy, to obtain reflectivity images of the ductolobular structures using tomographic reconstruction procedures. The 3-MHz transducer array comprises 1024 elements set in a 190-degree circular arc with a radius of 100 mm. The front-end electronics incorporate 32 independent parallel transmit/receive channels and a 32-to-1024 multiplexer unit. The transmit and receive circuitries have a variable sampling frequency of up to 80 MHz and 12-bit precision. Arbitrary waveforms are synthesized to improve the signal-to-noise ratio and to increase the spatial resolution when working with low-contrast objects. The setup was calibrated with academic objects and a needle hydrophone to develop the data correction tools and specify the properties of the system. The backscattering field was recorded using a restricted aperture, and tomographic acquisitions were performed with a pair of 0.08-mm-diameter steel wires, a low-contrast 2-D breast phantom, and a breast-shaped phantom containing inclusions. Data were processed with dedicated correction tools and a pulse compression technique. Objects were reconstructed using the elliptical back-projection algorithm.  相似文献   

12.
A new system for real-time synthetic aperture ultrasonic imaging   总被引:2,自引:0,他引:2  
The authors devised a way to generate in real time a cross-sectional image of an object with uniformly high resolution based on the synthetic aperture focusing technique (SAFT). A computer simulation was conducted to study the effects of essential parameters on the resulting images. An imaging system was built that produces a cross-sectional image composed of an assembly of line images of depth direction, i.e. processed A-scan images, and displays a scroll picture on a CRT (cathode ray tube) with no interruption regardless of the object size. It takes only 3 ms from the start of transmission of the ultrasonic wave to the completion of a line image reconstruction, and the framed image on a CRT is updated at the TV rate of 1/30 s. Imaging experiments were conducted using the system, and its expected performance was demonstrated.  相似文献   

13.
Modeling ultrasound imaging as a linear, shift-variant system   总被引:1,自引:0,他引:1  
Wo solve the equation that governs acoustic wave propagation in an inhomogeneous medium to show that the radio-frequency (RF) ultrasound signal can he expressed as the result of filtering the scatterer field with a point-spread function. We extend the analysis to make the link between the RF ultrasound signal and the representation of ultrasound scatterers as vectors with small magnitude and random phase in the complex plane. Others have previously performed parts of this analysis. The contribution of the present paper is to provide a single, coherent treatment emphasizing the assumptions that have to be made and the physical consequences of the models derived. This leads to insights into the interaction of monopole and dipole scattering, useful techniques for simulating and analyzing speckle statistics in the complex plane and a new expression for the normalized covariance of the analytic RF ultrasound signal in terms of the complex envelope of the point-spread function.  相似文献   

14.
Prostate cancer is the most commonly diagnosed cancer in men in North America. Although two-dimensional (2-D) transrectal ultrasound imaging is widely used for the evaluation of prostate disease, it suffers from limitations that limit its use in diagnosis and therapy of prostate cancer. The use of conventional ultrasound requires that the diagnosticians mentally integrate a series of 2-D images in order to develop an impression of the three-dimensional (3-D) anatomy, and to estimate the volume of the prostate. This approach depends of the expertise of the physician resulting in variability. We have developed a 3-D ultrasound imaging approach that overcomes this problem. In this paper, we describe a 3-D ultrasound imaging system for use in prostate imaging and report on its performance. The system consists of a conventional ultrasound machine, a microcomputer with a video frame grabber, and a custom-built assembly for rotating the ultrasound transducer. A typical scan of 100 2-D B-mode images takes 8 s. These images are then reconstructed into a 3-D image, which can be displayed and interactively manipulated using 3-D visualization software. We also show that manual planimetry of prostates in the 3-D images can be used to estimate volumes in vitro with an accuracy of 2.6%, and a precision of 2.5%; and in vivo with 5.1% intra-observer variability and 11.4% interobserver variability. Thus, 3-D ultrasound imaging overcomes some of the limitations of conventional imaging of the prostate, and has great potential as a tool in the diagnosis and treatment of prostate disease  相似文献   

15.
A new ultrasound contrast imaging technique is described that optimally employs the rupture of the contrast agent. It is based on a combination of multiple high frequency, broadband, imaging pulses and a separate release burst. The imaging pulses are used to survey the target before and after the rupture and release of free gas bubbles. In this way, both processes (imaging and release) can be optimized separately. The presence of the contrast agent is simply detected by correlating or subtracting the signal responses of the imaging pulses. Because the time delay between the imaging pulses can be very short, the subtraction is less affected by tissue motion and can be done in real time. In vitro measurements showed that by using a release burst, the detection sensitivity increased 12 to 43 dB for different types of contrast agents. In the presence of a moving phantom, the increase in sensitivity was 22 dB. This new method is very sensitive for contrast agent detection in fundamental imaging mode and, therefore, non-linear propagation effects do not limit the maximum obtainable agent-to-tissue ratio. However, because of the inherent destruction of the contrast agent, it has to operate in an intermittent way. Through experiments, we have demonstrated the potential of the method to achieve simultaneous high sensitivity for contrast detection, i.e., high agent-to-tissue ratio, and high spatial resolution performance for different types of contrast agents  相似文献   

16.
An ultrasonic ring transducer system has been developed for experimental studies of scattering and imaging. The transducer consists of 2048 rectangular elements with a 2.5-MHz center frequency, a 67% -6 dB bandwidth, and a 0.23-mm pitch arranged in a 150-mm-diameter ring with a 25-mm elevation. At the center frequency, the element size is 0.30lambda x 42lambda and the pitch is 0.38lambda. The system has 128 parallel transmit channels, 16 parallel receive channels, a 2048:128 transmit multiplexer, a 2048:16 receive multiplexer, independently programmable transmit waveforms with 8-bit resolution, and receive amplifiers with time variable gain independently programmable over a 40-dB range. Receive signals are sampled at 20 MHz with 12-bit resolution. Arbitrary transmit and receive apertures can be synthesized. Calibration software minimizes system nonidealities caused by noncircularity of the ring and element-to-element response differences. Application software enables the system to be used by specification of high-level parameters in control files from which low-level hardware-dependent parameters are derived by specialized code. Use of the system is illustrated by producing focused and steered beams, synthesizing a spatially limited plane wave, measuring angular scattering, and forming b-scan images.  相似文献   

17.
We report the design and experimental results of a field-programmable gate array (FPGA)-based real-time ultrasound imaging system that uses a 16-element phased-array capacitive micromachined ultrasonic transducer fabricated using a fusion bonding process. The imaging system consists of the transducer, discrete analog components situated on a custom-made circuit board, the FPGA, and a monitor. The FPGA program consists of five functional blocks: a main counter, transmit and receive beamformer, receive signal pre-processing, envelope detection, and display. No dedicated digital signal processor or personal computer is required for the imaging system. An experiment is carried out to obtain the sector B-scan of a 4-wire target. The ultrasound imaging system demonstrates the possibility of an integrated system-in-a-package solution.  相似文献   

18.
In vitro and/or in vivo experimental tests represent a crucial phase in the development of new ultrasound (US) investigation methods for biomedical applications. Such tests frequently are made difficult by the lack of flexibility of general purpose instruments and commercial US machines typically available in research laboratories. This paper presents a novel, real-time development system specifically designed for US research purposes. Main features of the system are the limited dimensions (it is based on a single electronic board), the capability of transmitting arbitrary waveforms to two probes, of storing the received radio-frequency (RF) echo data in a file and/or of processing them in real-time according to programmable algorithms. As an example of application, results of simultaneous hemodynamic and mechanic investigations in human arteries are reported. However, the high system flexibility and portability make it suitable for a large class of US applications.  相似文献   

19.
A phase aberration correction method for ultrasound imaging   总被引:2,自引:0,他引:2  
A computationally efficient method for phase aberration correction in ultrasound imaging is presented. The method is based on time delay estimation via minimization of the sum of absolute differences between radio frequency samples of adjacent array elements. Effects of averaging estimated aberration patterns over scan angle and truncation to a single bit wordlength are examined. Phase distortions due to near-field inhomogeneities are simulated using silicone rubber aberrators. Performance of the method is tested using experimental data. Simulation studies addressing different factors affecting efficiency of the method, such as the number of iterations, window length, and the number of scan angles used for averaging, are presented. Images of a standard resolution phantom are reconstructed and used for qualitative testing.  相似文献   

20.
A real-time ultrasound time-domain correlation (UTDC) blood flowmeter has been developed. Real-time performance has been achieved through the implementation of a custom-designed high-speed residue-number system (RNS) hardware correlator. The flowmeter is interfaced to a commercial ultrasound imager and can produce one-dimensional velocity versus range graphs at a rate of three per second. It has been validated in a blood flow phantom under a variety of conditions along with in vivo measurements in the human carotid artery. The theory of the time-domain correlation technique, design and implementation of flowmeter hardware, and the important correlation parameters which affect the performance of the flowmeter are described.  相似文献   