首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The authors constructed and tested a model superconducting fault current limiter (SFCL) using a high-temperature superconducting film according to a design that includes a vacuum interrupter with an electromagnetic repulsion mechanism. The superconductor and the vacuum interrupter are connected in parallel with a bypass coil. If a fault occurs and current flows through the system, the superconductor is quenched and the current is transferred to the parallel coil because of the voltage drop in the superconductor. This large current in the parallel coil actuates the magnetic repulsion mechanism of the vacuum interrupter. On opening the vacuum interrupter, the current in the superconductor is interrupted. This model is expected to exhibit very low-energy consumption by the superconductor. The authors succeeded in interrupting the current flowing in the superconductor within a half-cycle using a prototype SFCL. An improved SFCL with higher voltage and current ranges was used to carry out current-limiting tests and to investigate the possibility of adapting our SFCL in a power system. The authors also carried out a currentlimiting test using a conventional high-speed vacuum circuit breaker (HSVCB) as a new method for realising our concept.  相似文献   

2.
Numerous proposed and developed superconducting fault current limiters and self-limiting transformers limit successfully fault currents but do not provide uninterrupted supplying of consumers. A design investigated in the work combines the functions of a conventional transformer with the functions of fast energy redistribution and fault protection. The device constitutes a transformer containing an additional high-temperature superconducting (HTS) coil short-circuited by a thin film HTS switching element. Fault current limitation and redistribution of the power flow to a standby line are achieved as a result of a fast transition of the superconducting switching element from the superconducting into the normal state. Transient and steady-state characteristics were experimentally investigated. A mathematical model of the device operation was proposed, and the calculated results were found to be in good agreement with the experimental data. The application field and basic requirements to such devices were discussed and it was shown that the proposed device meets these requirements.  相似文献   

3.
There are many irreplaceable advantages of high temperature superconducting (HTS) fault current limiter, applying in electric utilities. It is expected to be able to solve excessive fault current problems and to enhance safety and stability of power systems. In this paper, the R and D of an improved bridge-type 10.5 kV three-phase superconducting fault current limiter (SFCL) was present. Each phase adopted a HTS coil with inductance of 6.2 mH. The three coils wound with 8,571 m Bi2223/Ag tapes totally. After installation at a 110 kV/10.5 kV substation in Hunan Province of China, the performances of the whole SFCL were tested, including a three-phase-to-ground short circuit experiment at the pre-setup short circuit point. And then, the SFCL was put into operations in the 10.5 kV power grids for more than 11000 h. About 3 years later, the SFCL was moved, reinstalled, and put into operation again since February 16 of 2011 at a 10.5-kV superconducting power substation located in Baiyin, Gansu Province of China. In this paper, the redesigned and manufactured cryostats with nonmagnetic stainless steel, tests, and long-term operations of the SFCL in 10.5 kV power grids were also described in detail.  相似文献   

4.
Saturated DC reactor type superconducting fault current limiter (SFCL) had been proposed two years ago. It was classified to rectifier type SFCL. The changing inductance value with the operating mode has superior characteristics to reduce voltage sag during step increase of the load current. But it has the disadvantage of its weight. In this paper, rectifier type SFCL with shielded reactor has been proposed. The reactor which has superconducting ring or tube inside its winding is substituted to the DC link of the rectifier. The configuration looks like an air core transformer with secondary short winding. When the current through the bulk shield-ring reaches to a certain level, the flux penetrates to the shield body and finite impedance appears in the primary winding. In other words, when the surface flux density exceeds its critical flux density, the flux penetrates into the bulk superconductor, and increases equivalent inductance. The equivalent transient resistance of the shield was represented as a function of exponential of the time. Using this equivalent transient resistance, the transient impedance was expressed. The transient wave analysis using EMTDC (electro-magnetic transients in DC systems) has been described. Simulated waveforms are shown considering the source inductance, the leakage inductance, the coupling coefficient and the forward voltage drop of the semiconductor. And voltage sag was also investigated with 50% step load increase.Preliminary design was also performed. The coil size and number of turns are designed to obtain adequate inductance for the current limitation, and the central magnetic field of the coils are calculated. There is optimal aspect ratio to minimize the magnetic field with restriction in outer diameter of the coil.  相似文献   

5.
Research of the resistance characteristics of YBCO tape under short-time DC large current impact is the foundation of the developing DC superconducting fault current limiter (SFCL) for voltage source converter-based high voltage direct current system (VSC-HVDC), which is one of the valid approaches to solve the problems of renewable energy integration. SFCL can limit DC short-circuit and enhance the interrupting capabilities of DC circuit breakers. In this paper, under short-time DC large current impacts, the resistance features of naked tape of YBCO tape are studied to find the resistance – temperature change rule and the maximum impact current. The influence of insulation for the resistance – temperature characteristics of YBCO tape is studied by comparison tests with naked tape and insulating tape in 77 K. The influence of operating temperature on the tape is also studied under subcooled liquid nitrogen condition. For the current impact security of YBCO tape, the critical current degradation and top temperature are analyzed and worked as judgment standards. The testing results is helpful for in developing SFCL in VSC-HVDC.  相似文献   

6.
This paper presents a comparative study of resistive and inductive superconducting fault current limiter (SFCL) for power systems transient stability improvement. Two applications of transient stability assessment are presented in this paper: The first shows the efficiency of the resistive and inductive SFCL in series with a generator, the second uses SFCL installed in series with a transmission line. SFCL can just be operated during the period from the fault occurrence to the fault clearing; the modeling and the effect of SFCL has been investigated to have higher benefits for the power system. In the present work, modification of the admittance matrix method is used for modeling of SFCL; Critical Clearing Time (CCT) has been used as an index for evaluated transient stability. The transient stability is assessed by the criterion of relative rotor angles, using the Runge–Kutta method. The effectiveness of the proposed method is tested on the WSCC3 nine-bus system applied to the case of three-phase short circuit fault in one transmission line. A simulation and comparison are presented in this document.  相似文献   

7.
A superconducting fault current limiter (SCFL) consisted of a transformer with low reactance connected to the power line and with the secondary winding short-circuited by a modular superconducting limiter device with 16 elements connected in series was constructed and tested. The designed coupling transformer has low dispersion reactance in order to limit the voltage drop in the power line within the range of 5 % to 10 %. The experimental results showed that an insertion of a 0.125 Ω resistance limited the peak current to a factor of 2.5 times of the unlimited current. The power dissipation reached 39 kW during 100 ms, with an energy density of 380 J/cm3. Based on these results, the SCFL will be further tested in a 3 MVA (15 kV/380 V) generator for currents up to 10 kA.  相似文献   

8.
Minseok Joo 《低温学》2005,45(5):343-347
This paper dealt with current-limiting performances of an inductive high-Tc superconducting fault current limiter with an auxiliary coil. The fault current limiter mainly consists of the primary copper coil, secondary high-Tc superconducting rings, and auxiliary high-Tc superconducting coils, which are magnetically coupled through three-legged core. The superconducting fault current limiter as a series element in the power system is inserted to limit the fault current. The device presents fast variable-impedance features in the event of a fault condition. The fault current peak can become relatively large for certain ranges of the flux and the fault instant due to the core saturation. The auxiliary coil proposed in this paper was proven to increase the impedance of the SFCL up to more than 31% while preventing the core saturation.  相似文献   

9.
A rectifier type superconducting fault current limiter (SFCL) with non-inductive reactor has been proposed. The concept behind this SFCL is the appearance of high impedance during non-superconducting state of the coil. In a hybrid bridge circuit, two superconducting coils connected in anti-parallel: a trigger coil and a limiting coil. Both the coils are magnetically coupled with each other and have same number of turns. There is almost zero flux inside the core and therefore the total inductance is small during normal operation. At fault time when the trigger coil current reaches to a certain level, the trigger coil changes from superconducting state to normal state. This super-to-normal transition of the trigger coil changes the current ratio of the coils and therefore the flux inside the reactor is no longer zero. So, the equivalent impedance of both the coils increased thus limits the fault current. We have carried out computer simulation using EMTDC and observed the results. A preliminary experiment has already been performed using copper wired reactor with simulated super-to-normal transition resistance and magnetic switches. Both the simulation and preliminary experiment shows good results. The advantage of using hybrid bridge circuit is that the SFCL can also be used as circuit breaker. Two separate bridge circuit can be used for both trigger coil and the limiter coil. In such a case, the trigger coil can be shutdown immediately after the fault to reduce heat and thus reduce the recovery time. Again, at the end of fault when the SFCL needs to re-enter to the grid, turning off the trigger circuit in the two-bridge configuration the inrush current can be reduced. This is because the current only flows through the limiting coil. Another advantage of this type of SFCL is that no voltage sag will appear during load increasing time as long as the load current stays below the trigger current level.  相似文献   

10.
J. Sim  H.R. Kim  B.W. Lee  I.S. Oh 《低温学》2007,47(3):183-188
We present the fabrication and short circuit test results of a 14 kV single-phase resistive superconducting fault current limiter (SFCL) based on YBa2Cu3O7 (YBCO) films. Individual components were processed using the 4″ YBCO films and have the rated voltage and current of 600 V and 35 A at 77 K, respectively. Twenty four components, eight components in series and three lines in parallel, make a module having the rated voltage and current of 4.8 kV and 105 A, respectively. Three modules were assembled in series to produce the SFCL working at 77 K, a 14 kV single-phase machine for the 22.9 kV Y-Y grid. short circuit tests were successfully conducted in an accredited test facility with the maximum fault currents up to 14.1 kAP. All components quenched together upon faults and shared the rated voltage evenly without any supplementary device between the modules. This proves that the SFCL based on YBCO films may not only work reliably at 22.9 kV, but also provide technical feasibility for higher voltage application including the transmission grids.  相似文献   

11.
《低温学》2003,43(10-11):555-560
The high-Tc superconducting (HTS) magnet is an important element for developing HTS power equipments such as the dc reactor of the inductive type superconducting fault current limiter (SFCL). In order to use the HTS magnet for the large-scale power system, its critical current needs to be high enough. Generally, the double pancake HTS magnet has the severe decrease in the critical current because of magnetic field perpendicular to the tape surface. To fabricate a high critical current magnet, we wound a solenoid with the stacked tape. In this paper, the characteristics of the critical current of the HTS solenoid wound with the stacked tape were investigated. The results of this research can be used as the background data for the design of the large-scale HTS magnet.  相似文献   

12.
For the design of superconducting fault current limiter, the research about recovery time and AC loss is essential issue because this characteristic is closely related to stability and efficiency. In general, superconducting fault current limiter (SFCL) modules can be made into pancake or solenoid type coil. While the pancake type coil has smaller AC loss, it has longer recovery time compared with the solenoid type coil. In this paper, a new pancake type coil was proposed to decrease recovery time by improving their cryogenic condition. A new pancake type coil is made with spacers between adjacent superconducting tapes. However, as the thickness of the spacer was increased, the AC loss was increased unlike the recovery characteristic. From the experimental results, our group confirmed that the pancake type coil with the spacer has trade-off relationship between AC loss and recovery characteristics with the spacer thickness.The proposed results in this paper would be utilized to design superconducting fault current limiters.  相似文献   

13.
The characteristics of a flux-coupling type superconductor fault current limiter (SFCL) with pancake coils are investigated in this paper. The conventional double-wound non-inductive pancake coil used in AC power systems has an inevitable defect in Voltage Sourced Converter Based High Voltage DC (VSC-HVDC) power systems. Due to its special structure, flashover would occur easily during the fault in high voltage environment. Considering the shortcomings of conventional resistive SFCLs with non-inductive coils, a novel flux-coupling type SFCL with pancake coils is carried out. The module connections of pancake coils are performed. The electromagnetic field and force analysis of the module are contrasted under different parameters. To ensure proper operation of the module, the impedance of the module under representative operating conditions is calculated. Finally, the feasibility of the flux-coupling type SFCL in VSC-HVDC power systems is discussed.  相似文献   

14.
Superconducting fault current limiter (SFCL) has become one of the most ideal current limiting devices to solve the problem of increasing short-circuit current in high-voltage power grid. This paper presents a resistive-type SFCL model developed using simulation software PSCAD/EMTDC. After being verified by finite-element model and experimental results, the model is used to study the impact of SFCLs on the power grid and the co-ordination between SFCL and relay protections in 10 kV distribution network. A series of simulations are carried out to find appropriate parameters of SFCL model to cooperate with relay protection devices. The final result in this paper could provide important quantitative basis of parameters for SFCL to be applied in a real power system.  相似文献   

15.
Saturated iron core superconducting fault current limiter (SIC-SFCL) is a promising fault current limiting device for high or extra-high voltage power grids. It has low impedance in normal power transmission and turns high impedance when a short-circuit takes place. The dc bias system of a saturated iron core superconducting fault current limiter plays a key role in realizing these features. Our 35 kV/90 MVA SIC-SFCL has been running live-grid since January 2008 at Puji substation in Yunnan, China. In this paper, the working principle of the dc bias system will be introduced and results of artificially imposed short-circuit tests will be provided, which verifies the validity of this system.  相似文献   

16.
17.
When an HTS coated conductor (CC) is used as a conductor of a superconducting fault current limiter (SFCL), the CC is expected to be exposed to the over-current and temperature of the CC is expected to be increased rapidly by electrical joule heating. Because the CC is a composite tape, thermal and electrical properties of composite materials could affects over-current limiting capacity and recovery time of SFCL. This paper presents experimental and numerical results of over-current test and recovery time measurement test on four bifilar wound SFCL modules. The temperature transitions of the samples were estimated from total electrical resistance of the coils. We fabricated one bifilar solenoid coil and three bifilar pancake coils whose cryogenic conditions were different from the other coils. An numerical model was also fabricated to simulate the temperature transition and the numerical results were compared with experimental results.  相似文献   

18.
The hybrid superconducting fault current limiter (SFCL) is now at the stage of practical use in a power grid in Korea. A cryogenic cooling system was designed, fabricated, and successfully tested for a prototype of 22.9 kV/630 A SFCL. The operation scheme of cryogenic system has been investigated in preparation for temporary loss of cryocooler power in hybrid SFCL (in Kim et al., IEEE Trans. Appl. Supercond. 21(3):1284–1287, 2011). In this paper, we investigated the empirical modeling of cryogenic cooling system for SFCL using principal components and auto-associative support vector regression (PCSVR) for the prediction and fault detection of the cryogenic cooling system. For empirical model, data were acquired during a blackout test of cryogenic cooling system. Blackout times of the test were 1 hour and 4 hours at two operation current levels. Three set of data were used for training and optimization of the model and the rest set of data was used for verification. Signals for the model are temperatures measured at copper band and cold head of cryocooler, system pressure and liquid temperatures measured at two locations in liquid-nitrogen pool. For optimization of the SVR parameters, the response surface method (RSM) and particle swarm optimization (PSO) were adopted in this paper. After developing the empirical model we analyzed the accuracy of the model. Also, these results were compared with that of auto-associative neural networks (AANN). RSM and PSO gave almost the same optimum point. PCSVR showed much better performance than AANN in accuracy aspects. Moreover, this model can be used for the prognosis of cryogenic cooling system for SFCL.  相似文献   

19.
《低温学》2003,43(10-11):621-628
An inductive superconducting fault current limiter protects power system by limiting the amplitude of fault current by the inductance of its dc reactor. Therefore, it is very important to design the dc reactor of high critical current prior to fabrication. At first, the optimal design parameters were calculated by using finite element method and then the superconducting dc reactor for 1.2 kV/80 Arms inductive superconducting fault current limiter was designed by considering the conduction-cooling characteristics. Moreover, the design, fabrication and conduction-cooling method of the superconducting dc reactor were introduced. Actually, the superconducting dc reactor was fabricated and cooled down to 20 K by using GM cryocooler. Finally, the short-circuit test was performed and the experimental results were discussed.  相似文献   

20.
In a resistive superconducting fault current limiter (SFCL), the electrodynamic force among the YBCO tapes is enormous when experiencing a high short circuit current, which may cause deformation of tapes and damage of their electrical characteristics. The purpose of this paper is to investigate how much electrodynamic force the YBCO tapes can bear. In this paper, an electrodynamic force simulation model is built to simulate the force, which the two parallel tapes experience and their deformation when short-circuit currents of different value flow through. Then we conducted experiments to observe the deformation of the tapes when they are experiencing a short-circuit current and see if the volt-ampere characteristic of the tapes has a noticeable change after that. Combining the results of the simulation and the experiments, we can obtain the electrodynamic force that tapes can bear. The result can guide us to design the layout of the tapes in the SFCL in accordance with the required fault current level.  相似文献   