首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
PURPOSE: To compare lysozyme adsorption and absorption and bacterial adhesion interactions on conventional (etafilcon A) and silicone (balafilcon A) hydrogel contact lenses. METHOD: Lysozyme concentrations and activities associated with the lenses were determined after solvent extraction (trifluoroacetic acid/acetonitrile) and directly on the lenses without extraction with micrococcal- and micro-bicinchoninic acid (BCA) assays. Cells of bacteria with radiolabeled leucine and a cell recovery procedure were used in determinations of bacterial adhesion to lenses. RESULTS: Lysozyme was adsorbed and absorbed to the conventional etafilcon A lens at about a 10-fold greater concentration than to the balafilcon A silicone hydrogel lens. Enzyme activities on the surfaces of both lenses were similar but replenished after saline extraction only with the etafilcon A lens. Lysozyme on the lens surface showed significant lysis of Micrococcus luteus but had a negligible effect on the adhesion and survival of Staphylococcus aureus. Lysozyme did not appear to affect the survival of Pseudomonas aeruginosa on lenses. CONCLUSION: In vitro experiments show that concentrations of active lysozyme on the surface of the etafilcon A lens, unlike the balafilcon A lens which showed negligible absorption, may be sustained from the lens matrix. Lysozyme deposited on hydrogel lenses had marked activity against M. luteus but relatively minor effects on the primary adhesion of P. aeruginosa and S. aureus.  相似文献   

2.
PURPOSE: The aim of this study was to evaluate the influence of lens material and lens wear on the removal capability of Staphylococcus epidermidis. Assessment of viability of remaining adhered bacteria was another goal of this work. Four silicone hydrogel materials (galyfilcon A, balafilcon A, lotrafilcon A, lotrafilcon B) and one conventional hydrogel material (etafilcon A) were assayed. METHODS: Detachment studies on S. epidermidis were carried out in a parallel plate flow chamber. Contact lenses (CLs) were fitted to the bottom of the flow chamber and a bacterial suspension was perfused into the system, promoting bacterial adhesion. Afterwards, detachment was stimulated using a multipurpose solution (MPS, ReNu Multiplus) and the percentage of removed bacteria estimated through microscopic observation and enumeration. Remaining adhered bacteria were stained with propidium iodide (PI) and enumerated in order to assess their viability. Additionally, the worn lenses were observed by confocal laser scanning microscopy (CLSM) to visualize bacterial distribution along the lens surfaces. RESULTS: Bacterial removal was significant (p<0.05) for both unworn and worn galyfilcon A and etafilcon A. Galyfilcon A exhibited a detachment percentage of 59.1 and 63.5 while etafilcon A of 62.6 and 69.3, both for unworn and worn lenses, respectively. As far as bacterial viability is concerned, it was found that worn lenses exhibit a superior amount of non-viable bacteria than unworn CLs. Images obtained by CLSM revealed an irregular bacterial distribution for all lens materials. CONCLUSIONS: It appears that surface and/or bulk structure of the lens material affects removal of S. epidermidis while CL wear influences their viability.  相似文献   

3.
PURPOSE: The purpose of this work was to evaluate the ability of four silicone-hydrogel contact lenses (galyfilcon A, balafilcon A, lotrafilcon A and lotrafilcon B) to retain their equilibrium water content before and after wear, through measurements of refractive index and compare with that of a conventional disposable hydrogel contact lens (etafilcon A). METHODS: The refractive indices of 115 contact lenses were measured using an automated refractometer (CLR 12-70, Index Instruments, Cambridge, U.K.) before and after a schedule of daily wear by 58 patients for 30 days in the case of silicone-hydrogel lenses and 15 days for the conventional contact lenses. RESULTS: In the silicone-hydrogel contact lenses the changes on the refractive indices were not statistically significant, however after being worn the refractive index of the conventional etalfilcon A hydrogel contact lens increased significantly (p<0.001). CONCLUSION: The results presented here show that after being worn the silicone-hydrogel contact lens, show more capacity to retain or to reach their initial equilibrium water content than conventional hydrogel contact lenses. This suggests that the silicone-hydrogel contact lenses are less susceptible to spoilation over time maintaining its biocompatibility and contributing to the clinical success of lens performance.  相似文献   

4.
PurposeTo compare the potential of different soft contact lenses to be contaminated with Acanthamoeba castellanii as a function of material parameters and cleaning procedures.MethodsDifferent unworn soft hydrogel and silicone hydrogel contact lenses were incubated with human pathogenic A. castellanii. The adhesion of the acanthamoebae was investigated on the contact lenses and put into relation to their material parameters. The efficacy of a recommended contact lens cleaning procedure in reducing A. castellanii adhesion was investigated.ResultsWe found that material parameters such as elastic modulus, silicone content, ionic properties and swelling do not influence the adhesion of acanthamoebae to soft contact lenses. A material parameter that influenced adhesion significantly was the water content of the lens. With increasing water content, the adhesion of acanthamoebae increased. By following the cleaning instructions of the manufacturer the contamination of the lenses with A. castellanii could be reduced to a minimum, as shown both on contact lenses and in control experiments.ConclusionWith this study we show that for the tested lenses, the adhesion of A. castellanii to contact lenses is independent of the silicone content of the lens, but depends nonlinearly on the water content of the lens. Furthermore, we demonstrate that applying proper lens cleaning procedures minimizes the risk of acanthamoebae adhesion to contact lenses.  相似文献   

5.
PurposeSeveral clinical studies have suggested that reusable silicone hydrogel contact lens materials exhibit a two-times increased rate of corneal infiltrative events compared to reusable hydrogels. One potential factor contributing to this complication relates to the differential uptake of tear film-based pro-inflammatory cytokines. The purpose of this study was to use an in vitro assay to investigate whether four pro-inflammatory cytokines differed in their uptake onto six contemporary contact lens materials.MethodsConventional hydrogel (etafilcon A, omafilcon A) and silicone hydrogel (balafilcon A, comfilcon A, senofilcon A, somofilcon A) contact lens materials were soaked in solutions containing pro-inflammatory cytokines IL-1β, IL-6, IL-8 and TNF-α. Samples of the soaking solutions were collected over various time points and analyzed using the Meso Scale Discovery system, which served as a measurement of cytokine uptake onto the contact lens materials.ResultsBoth conventional hydrogels (etafilcon A, omafilcon A) and two of the four silicone hydrogels tested (balafilcon A, comfilcon A), exhibited some uptake of IL-1β, IL-8 or TNF-α (p < 0.05). Senofilcon A and somofilcon A did not exhibit uptake of any of these cytokines (p > 0.05). There was no uptake of IL-6 onto any of the contact lens materials investigated (p > 0.05).ConclusionThe contact lens materials tested did not exhibit any uptake of IL-6 and furthermore, did not exhibit more than 10 ± 3 % to 25 ± 12 % uptake of IL-1β, IL-8 or TNF-α. Numerous factors could contribute to the reported increase in corneal infiltrative events with reusable silicone hydrogel materials, however, based on these results, it appears that uptake of these four cytokines are unlikely to contribute to this finding.  相似文献   

6.
Frequent replacement contact lenses made from the etafilcon A hydrogel lens material were introduced onto the market over 30 years ago, and etafilcon A remains the most widely used hydrogel lens material today. Although the prescribing of silicone hydrogel lenses is increasing, millions of lens wearers globally have been wearing hydrogel lenses for many years and exhibit a physiologically-stable ‘quiet eye’, with a low profile of adverse events. Hydrogel lenses are demonstrated to maintain a low inflammatory response and infection risk profile during daily wear, which in the case of etafilcon A, may be related to its low modulus, and the naturally-protective, anti-microbial, non-denatured lysozyme absorbed into the lens from the tear fluid. Although improved corneal physiology from decreased hypoxia with silicone hydrogel lenses is well accepted, equivalent levels of corneal oxygenation are maintained during daily wear of low to medium powered hydrogel lenses, which do not impede the daily corneal de-swelling process, and do not induce clinically significant changes in ocular health. Therefore, hydrogel lenses remain an important alternative for daily wear in modern contact lens practice.  相似文献   

7.
PURPOSE: To investigate the water content of hydrogel lenses of relatively high plus power hydrogel lenses after 3 months extended wear and compare values with unused lenses. METHOD: Geriatric aphakic extended wear soft lens patients were fitted with one of four different brands of hydrogel lenses (A) Incanto 78 (Cantor and Nissel, UK), (B) PSL72 (Prospect lenses, UK), (C) ES70 (Ocular Sciences), (D) Proclear (Coopervision). After 3 months continuous wear the lens was removed and water content (WC) was determined at both lens surfaces using an Abbé refractometer. The water content was also measured for 40 unused lenses (+10 to +20D, 10 lenses per brand). RESULTS: One hundred and thirty-two lenses were checked after 3 months extended wear. Mean (+/-S.D.) WC values for front (f) and back (b) surfaces of worn and unworn lenses were, respectively, (A) Worn (n=45): f 73.2(4.13) b 73.8(4.33); unworn f 80.5(0.68) b 81.1 (0.80). (B) Worn (n=37); f 70.5(4.49) b 70.9 (3.89); unworn f 72.5(0.94) b 72.3 (0.89). (C) Worn (n=34); f 68.3(3.18) b 68.4(3.63); unworn f 70.6 (0.48) b 71.1 (0.55). (D) Worn (n=16); f 63.4(3.68) b 63.3(3.19); unworn f 60.9 (1.56) b 61.5 (1.92). There was a significant correlation between WC measured from front and back surfaces (p < 0.01). In worn A-C lenses, front surface WC tended to be lower than back surface WC. For lenses A and C at both surfaces the WC of worn lenses was significantly lower than unworn lenses (p < 0.05). For lens D, mean WC of worn lenses was significantly higher than unworn lenses (p < 0.05). In 80% of B lenses, surface WC of worn lenses were significantly lower than WC of unworn lenses (p < 0.05). There was no relationship between WC and lens power. CONCLUSION: On average, A and C lenses tended to desiccate but D lenses tended to swell as did 20% of B lenses. The front surface of worn lenses measured lower water content than the back surface suggesting the front surface is drier than the back. This apparent difference in water content between the surfaces could be an artefact emanating from differential rates of surface deposition.  相似文献   

8.
PURPOSE: To compare the initial comfort afforded by silicone hydrogel lenses (lotrafilcon A) versus the comfort afforded by conventional hydrogel lenses (etafilcon A) in extended wear (EW). DESIGN: Prospective, double-masked and randomized controlled trial. METHODS: Lotrafilcon A and etafilcon A contact lenses were eye randomly fitted on an EW basis for 7 days and nights in 20 subjects. A forced-choice subject preference questionnaire was made. Subjects were comfort, dryness, red eye and visual quality after night wear and at the end of the day. Subjective scored satisfaction (scale: 1-5) and lens preference were assessed. RESULTS: Lotrafilcon A proved more comfortable after night wear (60%, CI95% 38-82%) and at the end of the day (70%, CI95% 49-90%) than etafilcon A after night wear (10%, CI95% 0-23%, P<0.05) and at the end of the day (20%, CI95% 2-38%, P<0.05). The feeling of dryness was more marked with etafilcon A after night wear (50%, CI95% 27-72%) and at the end of the day (50%, CI95% 27-72%) than it was with lotrafilcon A (15%, CI95% 0%-31%) after night wear (P>0.05) and at the end of the day (25%, CI95% 5%-44%, P<0.05). General satisfaction with the lotrafilcon A lens was 3.65 points (CI95% 3-4.2) and with etafilcon A 2.95 points (CI95% 2.5-3.3, P<0.05). Eighty percent (CI95% 62%-98%) of subjects preferred lotrafilcon A (P<0.05) for EW. CONCLUSIONS: In EW, lotrafilcon A contact lenses were more comfortable and led to less dryness after night wear and at the end of the day than etafilcon A contact lenses.  相似文献   

9.
High Dk silicone hydrogel lenses have overcome many of the hypoxic problems associated with traditional extended wear and the popularity of continuous wear (up to 30 nights) with these lens types is increasing. Results from clinical trials indicate that the typical physiological changes associated with edema from conventional extended wear of low Dk/t lenses do not occur with continuous wear of silicone hydrogel lenses. These changes include neovascularization, striae, microcysts and an increase in bulbar and limbal hyperemia. It is perhaps not surprising though that a number of adverse events do still occur with silicone hydrogel lenses when they are worn on a continuous wear basis. These include inflammatory conditions such as contact lens-induced peripheral ulcers (CLPU), contact lens-induced acute red eye (CLARE), infiltrative keratitis (IK) and contact lens papillary conjunctivitis (CLPC). Other events such as superior epithelial arcuate lesions (SEAL) and localised CLPC may be due to mechanical influences. While these conditions are not sight threatening, they may be painful and are certainly inconvenient to both the patient and the practitioner. It is therefore very important that the signs and symptoms associated with these events be recognised in order that they may be accurately identified and appropriately managed. The purpose of this review article is to describe the pathophysiology, etiology, and clinical presentation of these adverse events when observed with continuous wear contact lenses and to discuss their associated risk factors and incidence. Clear management and treatment strategies are also presented and a number of approaches to minimize adverse events with continuous wear of silicone hydrogel contact lenses are suggested.  相似文献   

10.

Purpose

To describe the refitting of a soft lens wearer into a silicone hydrogel lens due to neovascularization. This change, in turn, caused contact lens induced papillary conjunctivitis (CLPC) and a further refitting was necessary.

Methods

The patient was refit into a high Dk surface treated silicone hydrogel with a high modulus value. A second refitting was undertaken into a lower Dk silicone hydrogel contact lens with a lower modulus value which had no surface treatment but incorporated an internal wetting agent.

Results

A high Dk/t lens was used to resolve existing neovascularization and chronic hyperaemia. Subsequently, CLPC response occurred, possibly due to a combination of factors, resulting in irritation of the palpebral conjunctiva. This resulted in temporary lens discontinuation. A second silicone hydrogel lens was fit, along with the use of a non-preserved care system, which led to improvement and eventual resolution of the condition.

Conclusion

High Dk silicone hydrogel lenses have shown excellent efficacy in resolving hypoxic complications such as neovascularization and hyperaemia. However, attention needs to be paid to their potential effect on the upper tarsal plate. More than one silicone hydrogel lens may be needed to help resolve these issues.  相似文献   

11.
AIM: To determine the dynamic emitted temperature changes of the anterior eye during and immediately after wearing different materials and modalities of soft contact lenses. METHOD: A dynamic, non-contact infrared camera (Thermo-Tracer TH7102MX, NEC San-ei) was used to record the ocular surface temperature (OST) in 48 subjects (mean age 21.7 +/- 1.9 years) wearing: lotrafilcon-A contact lenses on a daily wear (LDW; n=8) or continuous wear (LCW; n=8) basis; balafilcon-A contact lenses on a daily wear (BDW; n=8) or continuous wear (BCW; n=8) basis; etafilcon-A contact lenses on a daily disposable regimen (EDW; n=8); and no lenses (controls; n=8). OST was measured continuously five times, for 8s after a blink, following a minimum of 2h wear and immediately following lens removal. Absolute temperature, changes in temperature post-blink and the dynamics of temperature changes were calculated. RESULTS: OST immediately following contact lens wear was significantly greater compared to non-lens wearers (37.1 +/- 1.7 degrees C versus 35.0 +/- 1.1 degrees C; p < 0.005), predominantly in the LCW group (38.6 +/- 1.0 degrees C; p < 0.0001). Lens surface temperature was highly correlated (r=0.97) to, but lower than OST (by -0.62 +/- 0.3 degrees C). There was no difference with modality of wear (DW 37.5 +/- 1.6 degrees C versus CW 37.8+/-1.9 degrees C; p=0.63), but significant differences were found between etafilcon A and silicone hydrogel lens materials (35.3 +/- 1.1 degrees C versus 37.5 +/- 1.5 degrees C; p < 0.0005). Ocular surface cooling following a blink was not significantly affected by contact lens wear with (p=0.07) or without (p=0.47) lenses in situ. CONCLUSIONS: Ocular surface temperature is greater with hydrogel and greater still with silicone hydrogel contact lenses in situ, regardless of modality of wear. The effect is likely to be due to the thermal transmission properties of a contact lens.  相似文献   

12.
PurposeUsing atomic force microscopy (AFM) to investigate anterior surface topography (AST) in worn and unworn, plasma surface-treated (PST) and untreated (UT) gas permeable (GP) lenses, and influence of surface topography on in vivo comfort.MethodsGP lens AST evaluated with AFM in tapping mode, using an uncoated, 40 nm symmetric tip (sampling frequency: 300 kHz), at five randomised locations, over a 100μm2 area, to produce mean average roughness (Ra) and root mean square (RMS) values for each sample. Four unworn lenses (two PST, two UT) were examined (Quasar/Boston EO material). Twenty worn lenses (ten PST, ten UT) of same design and material as unworn lenses collected after 3 months lens wear. General wearing comfort reported by visual analogue scale (VAS) at 3 months visit. For sample preparation, two worn UT GP lenses were divided into four segments; each segment underwent a different lens rinse and drying method.ResultsUnworn: UT lenses had significantly higher mean RMS and Ra values compared to PST (Mann-Whitney, p < 0.05). Worn: UT Median RMS values were significantly higher than PST (Mann-Whitney, p < 0.05). Comfort: no correlation found between general comfort and RMS or Ra scores. Sample preparation: Method 4 (purified, distilled water rinse/nitrogen gas dry) produced optimum median RMS and Ra values.ConclusionsUnworn PST GP lenses had lower Ra and RMS values compared with unworn UT GP lenses. After 3 months wear, PST lenses had smoother surface topographies than UT lenses. No relationship was found between surface topography and lens wear comfort. Sample preparation protocol directly impacts AFM results.  相似文献   

13.
AIM: The study determined the effects of packaging solution osmolality and buffering agent on soft contact lens parameters. METHODS: One lens type from each FDA contact lens material category was equilibrated to phosphate buffered saline (PBS) or borate buffered saline (BBS), at three osmolality concentrations: 270, 310 and 414 mOsmol/kg. Lens diameter (LD), base curve (BOZR) and back vertex power (BVP) were measured and compared to nominal packaging label values. RESULTS: Statistically significant differences were found in all three parameters across all osmolality levels for both buffering agents. Etafilcon A showed the largest amount of parameter change, followed by alphafilcon A and balafilcon A. Lotrafilcon A was the least affected. LD of alphafilcon A lenses (greater than +/- 0.2 mm) and BVP of lotrafilcon A and etafilcon A lenses (greater than +/- 0.25 D) measured outside the International Standards Organization (ISO) tolerance from their packaging labels when measured in solutions that mimicked their packaging solutions. CONCLUSION: Osmolality and buffering agents influence lens parameters. Packaging solutions can vary the parameters of some lens types from their nominal value to outside the tolerance range set by ISO.  相似文献   

14.
PurposeThe purpose of this study was to evaluate the uptake and release of radiolabelled polyhexamethylene biguanide (PHMB) on reusable daily wear contact lenses (CLs) over 7 days.MethodsThree silicone hydrogel (SH) contact lens materials (lotrafilcon B, balafilcon A, senofilcon A) and two conventional hydrogel (CH) materials (etafilcon A, omafilcon A) were examined. In experiment 1 (1-day study), CLs were soaked in 2 mL of phosphate buffered solution (PBS) containing radiolabelled 14C PHMB (1 µg/mL) for 8 h. The release kinetics of 14C PHMB from the CLs was measured at t = 0.25, 0.5, 1, 2, 4, 8, and 24 h in fresh 2 mL PBS. In experiment 2 (7-day study), the CLs were soaked in the 14C PHMB (1 µg/mL) solution for 8 h followed by a 16-hour release in 2 mL PBS. The lens cycle was repeated daily for 7 days. After both experiments, the residual amount of PHMB remaining within the lenses was extracted to determine the total uptake of PHMB.ResultsIn experiment 1, the total uptake of PHMB for etafilcon A was significantly greater than senofilcon A (p = 0.01). There were no significant differences in total uptake of PHMB between other lens materials (p > 0.05). Etafilcon A released more PHMB compared to all other lens types over a 24-hr period (p < 0.001). In experiment 2, all CL materials continued to sorb more PHMB over time (p < 0.001). By day 7, the amount of PHMB sorbed by etafilcon A was significantly greater than senofilcon A (p = 0.02). After day 2, the CH materials released significantly more PHMB than the SH materials (p < 0.01).ConclusionThe CL materials continued to sorb PHMB with no signs of saturation after 7 days. All lens materials released a consistent amount of PHMB each day. Radioactive labelling provides a sensitive method of assessing the uptake and release of PHMB from CL materials.  相似文献   

15.
The use of rigid materials with high oxygen permeability (Dk) is on the increase, their major benefit being the reduction of hypoxia. However, there is a reluctance to use these materials possibly due to increased surface scratching, reduced wettability, increased deposition, reduced life expectancy and parameter instability. Considering parameter stability, various studies have demonstrated contradictory results or used high Dk materials based on the silicone acrylate polymer. This study was designed to investigate whether the parameters of a high Dk rigid fluorocarbon contact lens material changed during daily wear and extended wear schedules. Thirty five subjects, divided into group groups, Group I wore the lens on a daily wear basis, whereas those in Group II wore the lens on a monthly extended wear basis. The parameters and integrity of the lenses were monitored in both groups every 3 months. For lens integrity a statistically significant increase in surface scratching was demonstrated for the lenses worn by the subjects of both groups over the time of the study (Group I, F=7.990, P <0.0001 [ANCOVA]; Group II, F=6.241, P=0.003 [ANCOVA]). The only parameter to show a statistically significant variation over the study period was that of centre thickness for the lenses worn by the subjects in Group I (F=3.976, P=0.0063 [ANCOVA]), with a mean reduction in centre thickness of 0.022 mm at the 12 month visit. No change was noted for either group or between groups for the other parameters measured. This study demonstrates that the parameters of rigid contact lenses manufactured from high Dk fluorocarbons are stable with only a non-clinically significant reduction in centre thickness for the contact lenses worn by the subjects in Group I.  相似文献   

16.
PURPOSE: To evaluate the influence of surface treatment of silicone-hydrogel CL on lens hydrophobicity, protein adsorption and microbial colonisation by studying several silicone hydrogel contact lenses (CL) with and without surface treatment. The lenses used in this study were Balafilcon A, Lotrafilcon A, Lotrafilcon B and Galyfilcon A. A conventional hydrogel CL (Etafilcon A) was also tested. METHODS: Hydrophobicity was determined through contact angle measurement using the advancing type technique on air. The type and quantity of proteins adsorbed were assessed through SDS-PAGE and fluorescence spectroscopy, respectively. Microbial colonisation was studied by removing the microbes from the lenses through sonication, and counting the colony-forming units on agar plates. RESULTS: Regarding hydrophobicity, both surface and non-surface-treated silicone hydrogel CL were found to be hydrophobic, and the conventional hydrogel CL was found to be hydrophilic. Concerning protein adsorption, different protein profiles were observed on the several lenses tested. Nevertheless, the presence of proteins with the same molecular weight as lysozyme and lactoferrin was common to all lenses, which is probably related to their abundance in tears. In terms of total protein adsorption, silicone hydrogel CL did not exhibit any differences between themselves. However, the conventional hydrogel Etafilcon A adsorbed a larger amount of proteins. Regarding microbial colonisation, Balafilcon A exhibited the greatest amount of colonising microbes, which can be due to its superior hydrophobicity and higher electron acceptor capacity. CONCLUSION: This study suggests that silicone hydrogel lenses adsorb a lower amount of proteins than the conventional hydrogel lenses and that this phenomenon is independent of the presence of surface treatment. Concerning microbial colonisation, the surface treated Balafilcon A, exhibited a greater propensity, a fact that may compromise the lens wearer's ocular health.  相似文献   

17.
BACKGROUND: Models of oxygen delivery to the cornea with contact lens wear have considered the customary situation of one lens being worn on the cornea. However, two lenses, such as a rigid lens piggybacked on a soft lens, may be worn by patients with special ocular and visual needs. This paper extends existing single lens models to circumstances where two lenses offer resistance to oxygen in series. METHODS: Theoretical oxygen tensions are calculated for tear layers trapped beneath piggyback contact lens systems (and scleral lenses) and the anterior corneal surface with a simple single chamber corneal model using a personal computer software spreadsheet. RESULTS: Acceptable values are anticipated for contact lens materials of modern oxygen permeability values of approximately 60-100 Fatt Dk units under open eye conditions. CONCLUSIONS: The results of this spreadsheet model of oxygen supply to the anterior corneal surface offer a useful guide to clinicians concerned about providing their patients with physiologically acceptable piggyback lens systems.  相似文献   

18.
PurposeTo compare the sensitivity of two genotypes of P. aeruginosa to various disinfectant solutions and analyze the attached bacteria on worn cosmetic contact lenses (cosCLs).MethodsIn this prospective study, healthy volunteers wore etafilcon (brown), nelfilcon (gray), or hilafilcon (black) cosCLs and microbial adhesion analysis was performed. A rub-off test determined pigment dislodgement. Disinfectant sensitivity to Optifree Replenish (Alcon), Optifree Pure Moist (Alcon), Renu Fresh (Bausch & Lomb), and AoSept Plus (Ciba Vision) was tested at various disinfection times and compared between various genotypes and Type III secretion (T3S) system mutants.ResultsOf the 1152 cosCLs collected, 364 were culture positive (32%). The highest rate of culture-positive lens was hilafilcon (chi square, P = 0.0001). Hilafilcon also had a significantly greater number of isolates than etafilcon (P < 0.0001). Hilafilcon was the only lens to fail the rub-off test. Cytotoxic strains were significant more resistant to Renu Fresh than were invasive strains, even at 100% of recommended disinfection time (P = 0.0005). Of the tested disinfectants, Renu Fresh was significantly less effective in killing both genotypes of P. aeruginosa compared to AoSept Plus at all time points (25%, 50%, 75%, and 100% recommended disinfection time, P = 0.0001, 0.0001, 0.0005, and 0.0005, respectively). When the T3S system was dysfunctional, mutant strains were all susceptible to disinfectants (P = 0.0001 for both invasive and cytotoxic strains).ConclusionPseudomonas species is commonly found on cosCLs of asymptomatic individuals. Wearers of cosCLs that dislodge pigments may be predisposed to microbial contamination. Cytotoxic strains are more resistant to disinfectant solutions, especially to Renu Fresh. P. aeruginosa disinfectant resistance requires a functional T3S system.  相似文献   

19.

Purpose

To compare the effects of a hydrogen peroxide (H2O2)-based lens care solution and a polyhexamethylene biguanide (PHMB) multi-purpose solution on the eyelids when used with silicone hydrogel (SiHy) contact lenses.

Methods

A total of 74 symptomatic wearers of ACUVUE® OASYS® (senofilcon A; n?=?39) or PureVision® (balafilcon A; n?=?35) contact lenses were randomised 1:1 to either CLEAR CARE® Cleaning & Disinfecting Solution or renu® fresh? multi-purpose solution (n?=?37 each). Assessments of hyperaemia, papillae and lid margin staining of eyelid tissue were evaluated subjectively by a masked investigator at enrolment (with the subjects’ habitual SiHy contact lenses and PHMB-preserved care systems), at dispensing visit (when no lenses were worn) and at 3-months’ follow-up.

Results

There were no differences in eyelid assessments between the two lens care groups at dispensing visit (p?=?0.086 to 0.947). After 3 months, the papillae response was significantly less marked with H2O2-based solution than with PHMB-based solution (p?=?0.017). Lid hyperaemia (p?<?0.001) and papillae (p?=?0.002) were also significantly reduced. Although lid hyperaemia was also reduced with PHMB-based solution (p?<?0.001), there was no concurrent decrease in papillae response (p?=?0.051). No improvements were found in eyelid margin staining either over time or between the two lens care groups.

Conclusion

In symptomatic contact lens wearers, a H2O2-based lens care solution used with senofilcon A and balafilcon A lenses was better tolerated by eyelid tissues than was a PHMB-based solution and led to a decrease in clinical markers of eyelid inflammation.  相似文献   

20.
AimTo investigate whether cosmetic contact lenses (CCL) with surface pigments affect microbial adherence.MethodFifteen brands of CCL were purchased from optical, non-optical retail outlets, and via the Internet. A standardized rub-off test was performed on each CCL (five lenses per brand) to confirm the location of the pigments. The rub-off test comprised gentle rubbing on the surfaces of each CCL with wetted cotton buds for a maximum of 20 rubs per surface. A new set of CCL (five lenses per brand) were incubated in Pseudomonas aeruginosa overnight. Viable counts of adhered bacteria were determined by the number of colony-forming units (CFU) on agar media on each lens. The adherence of P. aeruginosa as well as Staphylococcus aureus and Serratia marcescens to three brands of CCL (A–C) (five lenses per brand) were also compared to their adherences on their clear counterparts.ResultsOnly two of the 15 brands of CCL tested (brands B and C) had pigments that did not detach with the rub-off test. The remaining 13 brands of CCL all failed the rub-off test and these lenses showed higher P. aeruginosa adherence (8.7 × 105–1.9 × 106 CFU/lens). Brands B and C lenses showed at least six times less bacterial adhesion than the other 13 brands. Compared to their clear counterparts, bacterial adherence to brands B and C lenses did not differ significantly, whereas brand A lenses showed significantly higher adherence.ConclusionSurface pigments on CCL resulted in significantly higher bacterial adherence.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号