首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This in vitro study evaluated the effects of etchant type, surface moisture, and resin composite type on the shear bond strength of dentin adhesives. Three adhesives which bond to etched dentin were used in the study: All-Bond 2, Amalgambond, and Clearfil Photo Bond. Occlusal enamel was removed from 200 human molars to expose dentin. The dentin surfaces were etched, treated with a dentin adhesive system, and bonded with resin composite. After thermocycling and storage, the composite columns were fractured from dentin using an Instron machine. Bond strengths were calculated and subjected to a statistical analysis. Etchant type, surface moisture, and resin composite type all had significant effects on dentin bond strengths. Overall, the highest bond strengths were obtained with 10/3 etchant, moist dentin, and hybrid composite. The highest bond strengths for All-Bond 2 and Amalgambond were obtained by using the manufacturer's recommended etchant, moist dentin, and a hybrid composite. The mean bond strengths for All-Bond and Amalgambond under these conditions were 22.5 and 19.0 MPa, respectively. Clearfil Photo Bond had significantly lower bond strengths, but was relatively unaffected by changes in experimental conditions.  相似文献   

2.
The aim of this investigation was to study the effect of dentin depth and patient's age on the shear bond strength of one dentin adhesive (ART Bond), using an Instron Universal testing machine at a cross-head speed of 0.5 mm/min. Forty human molar teeth were used and were divided into two main groups, twenty each representing two age groups of patients, i.e., between 20 to 30 years and between 30-40 years of age. Every group was further subdivided into two subgroups of different dentin depths, i.e., superficial and deep. Results were recorded in Kg/Cm2 and converted into MPa units, then tabulated and statistically analyzed. A Duncan's range statistic test at P < or = 0.05 showed statistically significant differences between the bond strength values for both age groups at different dentin depths, with the superficial dentin showing higher bond values, and there were also statistically significant differences between the bond strength values of the two age groups at the same dentin depth, with the older age group showing higher bond values.  相似文献   

3.
The purpose of this study was to investigate the effect of dentinal disinfection with a 2% chlorhexidine or a 0.11% I2-KI/CuSO4 solution on the shear bond strength of three resin-modified glass-ionomer cements: Fuji II LC, Photac-Fil, and Vitremer. The occlusal surfaces of extracted human teeth were flattened to dentin. Specimens were randomly assigned to one of nine treatment groups (n = 12). For each glass-ionomer material, there was a control group and two treatment groups in which the dentin was treated with either a 2% chlorhexidine or a 0.11% I2-KI/CuSO4 solution before the dentin was treated with the recommended dentin conditioner prior to glass-ionomer bonding. Specimens were stored for 1 day in water, thermocycled, and tested in shear until failure. The chlorhexidine solution did not significantly affect the shear bond strengths of any of the cements, but the I2-KI/CuSO4 solution significantly lowered the bond strengths of Vitremer and Fuji II LC compared to the controls.  相似文献   

4.
This study evaluated the interaction of five clinical application techniques and the shear bond strength of four DBAs (OptiBond FL, Clearfil SE Bond, PQ1 and Prime & Bond NT). A hybrid resin composite (Herculite XRV restorative resin) was attached to human dentin surfaces using five application techniques: Group A--adhesive spread with a 3M brush for 30 seconds, followed by compressed air 0.5 cm from the surface for one second to remove the excess adhesive. Group B--adhesive spread with a 3M brush for 30 seconds, followed by compressed air 0.5 cm from the surface for three seconds to remove the excess adhesive. Group C--adhesive spread with 3M brush for 30 seconds, excess adhesive removed with a clean brush, two strokes side by side, no compressed air. Group D--adhesive spread with a Micro-applicator brush for 30 seconds followed by compressed air 0.5 cm from the surface for one second to remove the excess adhesive. Group E--adhesive spread with a Micro-applicator brush for 30 seconds, the excess adhesive removed with a clean brush, two strokes side by side and no compressed air. The specimens were stored in distilled water at 37 degrees C for 24 hours, followed by thermocycling between 5 degrees C and 55 degrees C for 1,000 cycles. The shear bond strengths were determined on a universal testing machine operating with a crosshead speed of 5 mm/minute. The fracture sites were examined by 20x stereo microscope to determine the type of failure that occurred during the debonding procedure. Bond strength data were compared with analysis of variance at a significance level of p<0.05. Post hoc comparisons of means were performed with t-tests with p-values adjusted for multiple comparisons. This in vitro study concluded that there was an interaction between the application technique and bonding agent tested. All DBAs utilized the one-second compressed air technique, which yielded the highest bond strengths.  相似文献   

5.
This study compared the effects of different dentin surface treatments on the shear bond strengths of three adhesive systems. The adhesive systems included a resin-modified glass ionomer, Fuji II LC, and two dentin bonding systems, One Step and Scotchbond Multi-Purpose Plus. The surface treatments compared for each adhesive system were as follows: 1) the controls, which were conditioned, 2) air abrasion at 120 psi without conditioning, 3) air abrasion at 160 psi without conditioning, 4) air abrasion at 120 psi with conditioning, and 5) air abrasion at 160 psi with conditioning. The KCP 1000 Whisperjet was used for all air-abrasive specimens. Controls for each adhesive material (Fuji II LC, One Step, Scotchbond Multi-Purpose Plus) were bonded using manufacturers' recommendations. Results showed that air abrasion significantly lowered bond strength of the resin-modified glass ionomer, conditioned or nonconditioned (P < 0.01). Air abrasion alone significantly lowered bond strengths of the dentin bonding agent systems (P < 0.01). However, air abrasion plus conditioning of the dentin surface resulted in bond strengths that were similar to the conditioned-only specimens (P < 0.01).  相似文献   

6.
We report a simple new method for measuring the conduction velocity (CV) of A delta fibers in normal subjects. A large positive component of somatosensory evoked potential (SEP) whose peak latency was approximately 250 ms was clearly recorded only when strong electrical stimulation causing a definite painful feeling was applied to the skin. The CV of the peripheral nerve was calculated by measuring the latency difference of this component between the distal-stimulated SEP and proximal-stimulated SEP and the distance between two stimulus sites. The CV was approximately 11.4 m/s, (range 8.8-15.9 m/s), in the range of A delta fibers. The sleep effect on pain-related SEP was also observed in 3 subjects. The amplitude of pain-related SEP decreased with the progress of sleep stage. This simple and novel method is available in most clinics and should be very useful in investigating the physiologic functions of peripheral nerves in patients as well as normal subjects.  相似文献   

7.
Several patients with end-stage renal disease went to Bombay for renal transplantation from nonrelated living donors and then returned to Turkey for posttransplantation follow-up. The aims of this study are to evaluate the long-term results of renal transplantation from nonrelated living donors in Turkish patients with end-stage renal disease and to discuss the ethical and social aspects of nonrelated kidney donation. One hundred and twenty-seven patients (89 males, 38 females; mean age 38.1, range 17-63 years) were investigated retrospectively. None of the patients went to Bombay on our advice. All transplantations were performed between 1991 and 1995. The mean follow-up period after transplantation was 34.2 (range 1-68) months. Graft survival rates were 85, 83, and 57% after 3 months and 1 and 5 years, respectively. Patient survival rates were 94, 93, and 92% after 3 months and 1 and 5 years, respectively. Seven patients died within the first 3 months after the transplantation. Surgical problems, infections, acute rejection, ciclosporin nephrotoxicity, and hepatic problems were common complications. We conclude that medical and surgical complications occur frequently in paid kidney transplantation, but most of these complications can be prevented by adequate preoperative management, and precautionary measures should be taken to prevent commercialization of renal transplantation before the spread of emotionally related living kidney donation.  相似文献   

8.
Round enamel and dentin surfaces of sound and carious extracted human teeth were irradiated by an ArF:excimer laser for up to 180 sec. Thermographic measurements indicated that the temperature rise due to heat accumulation caused by laser irradiation on these enamel and dentin surfaces was up to 19 degrees C (10 HZ with 540 J/cm2), and the temperature returned to the preirradiation value within 10 sec after the irradiation was stopped. Under light microscopy, no carbonization was evident on these surfaces, and a simple recess was formed by abrasion or vaporization in the irradiated regions. In the secondary SEM, uniformly distributed fine pores and prism structures appeared slightly on the enamel surfaces. Between the peritubular and the intertubular dentin, there appeared a distinct difference in the dissolved area. The laser almost completely removed carious regions of the enamel and the dentin, and penetration extended beyond the carious regions. In the backscattered electron SEM, highly mineralized layers were observed on the enamel and dentin surfaces dissolved by the laser.  相似文献   

9.
Recent studies have suggested that failure of pentamidine prophylaxis against Pneumocystis carinii pneumonia (PCP) may be due to reduced deposition of pentamidine in the upper lobes. In this study, we performed bronchoalveolar lavage from the apical segment of the upper lobe and the middle lobe in 51 HIV-positive patients, all of whom were receiving prophylaxis with aerosolized pentamidine, who had presented with acute respiratory symptoms. Lavage fluid from each lobe was assayed for pentamidine using high-performance liquid chromatography (HPLC). The number of clusters of P carinii were counted after staining with a Wright-Giemsa stain. The patients were subclassified as PCP-positive (32 patients) and PCP-negative (19 patients) on the basis of the presence/absence of P carinii clusters in their BAL fluid. The concentration of pentamidine in the upper lobe compared with the middle lobe was no different (using paired Student's t tests) for either PCP-positive patients or PCP-negative patients. In comparing the positive with the negative subjects, using unpaired Student's t test, there was no difference in the concentration of pentamidine in the upper lobe or the middle lobe. For PCP-positive patients, the numbers of P carinii clusters were on average higher in the upper lobes (mean +/- SD: upper = 14.9 +/- 16.6, middle 7.5 +/- 10.8, p = 0.013, paired Student's t test), but there was no correlation between lobar P carinii cluster counts and pentamidine levels. We conclude that the absence of a relationship between cluster count and pentamidine level, the similarity in regional pentamidine levels between upper and middle lobes, as well as the similarity in pentamidine levels between the PCP-positive and PCP-negative groups indicate that the regional dose of pentamidine is not the determining factor as to whether aerosolized pentamidine prophylaxis will succeed or fail.  相似文献   

10.
Within the context of an extensive study of electroconvulsive therapy at the Psychiatric Clinic of the University of Bonn 15 patients suffering from therapy-resistant Major depression (DSM III-R) were examined with a detailed psychometric test battery, containing memory- and nonmemory tests. The test battery had been applied short time before, during and after the treatment with 10 ECT applied unilateral over the nondominant hemisphere. Comparing the test performances before and 1-2 days after the end of the series there were only few remarkable changes: a significant decrease was diagnosed exclusively in 30 min delayed recall of verbal items, while visual short-term memory and visual-constructive performance showed a significant improvement (in spite of unilateral stimulation on the right side). None of the other cognitive functions inclusively speed of performances and reaction time was detracted short time after the end of the ECT-treatment, instead all the measures improved albeit not significantly. Between responders to treatment (50% improvement in HAMD) and non-responders no significant differences neither before nor after the treatment were detected. The non-responders had in nearly all of the tests some better (but not significantly) results despite being older than the group of responders.  相似文献   

11.
The article describes ultrasonographic (US), computed tomographic (CT), 99mTc-MIBI and angiographic findings of 16 cases of multiple endocrine neoplasia (MEN) confirmed by operations and pathological examinations. Hyperparathyroidism either was the first manifestation of MEN I or was diagnosed simultaneously with other tumors. Medullary thyroid carcinoma usually developed first or coincided with pheochromocytoma in MEN I. Regular US and CT screening can lead to the detection of new endocrine neoplasia. The authors consider that US and CT are the best imaging methods for MEN.  相似文献   

12.
The objective of this paper is to provide an ethical analysis of the concept of the fetus as a patient and to identify the clinical implications of this concept for maternal-fetal medicine. The principles of beneficence and respect for autonomy are applied to the viable and previable fetus. We argue that the viable fetus is a fetal patient. The previable fetus is a fetal patient only when the pregnant woman confers such status on it. When the fetus is a patient, directive counseling for fetal benefit is ethically justified. When the fetus is not a patient, counseling should be non-directive.  相似文献   

13.
Previous studies have shown little agreement between the test methods used to assess the bond strength and the mode of failure of resilient liners. This study evaluated the bond strength characteristics of resilient liners by means of 180-degree peeling and butt tensile strength testing. Seventy-two specimens were divided into peel bond and tensile bond specimen groups and were then subdivided into four test groups to evaluate each resilient liner. Tests were conducted with an Instron universal testing machine at a cross-head speed of 2 mm/minute for the tensile specimens and 5 mm/min for the peel specimens. Tensile bond strength and peel bond strength varied significantly among resilient liners except between Novus and Palasiv-62 liners in tensile testing. The mode of failure of Molloplast-B and Novus liners was significantly different between the tensile bond and peel bond test methods. It was concluded that bond strength characteristics can vary according to the test method used.  相似文献   

14.
Four third-generation dentin bonding products (Scotchbond Multi-Purpose, Optibond, All-Bond 2, and Prisma Universal Bond 3) were tested to evaluate their tensile bond strength to enamel. Test enamel specimens were etched, primed, and polymerized according to each manufacturer's directions. Control specimens were treated identically except the primer application was eliminated. The results demonstrated that the dentin primer significantly increased the tensile bond strength of All-Bond 2, significantly decreased the tensile bond strength of Scotchbond Multi-Purpose and Optibond, and had no significant effect for Prisma Universal Bond 3. A one-way analysis of variance was run between the eight groups tested, and three significant subsets were found (P < .05). The subset with the highest mean tensile bond strengths consisted of Prisma Universal Bond 3 primed and nonprimed, All-Bond 2 primed, and Optibond nonprimed.  相似文献   

15.
The effects of argon laser on the bony semicircular canals were studied in the guinea pig. After intraperitoneal administration of Nembutal, the bulla was opened in order to approach the lateral and posterior canals. The anterior canal was approached through the posterior fossa. The argon laser was applied through a probe which was connected to a device from HGM Medical Laser Systems. One of the three semicircular canals was irradiated one to several times by argon laser (1.0-1.5 W x 0.5 sec). Histopathologic examination of the temporal bones revealed that the semicircular duct shrank immediately after irradiation. The laser produced a charred area in the bony canal wall. The semicircular canals gradually became fibrotic and ossified and completely occluded within several weeks. Heat produced in the bony canal may be responsible for the morphologic changes. On delayed observation, the cochlea of the canal-irradiated animals showed no morphologic changes. Auditory brain stem responses were normal. Caloric stimulation using 5 ml/5 sec of ice water revealed no response in the lateral canal-irradiated animals.  相似文献   

16.
Clinical performance of light-curing composite restorations is greatly influenced by the quality of the curing-light. Currently used photopolymerization units have some important drawbacks, such as decreasing light output with time and distance, which results in a relatively low degree of conversion and shallow depth of cure, particularly of darker shades. Experiments with continuous argon laser polymerization showed overheating of the composite sample, as well as increased shrinkage of the material. In this study a pulsed laser, set at 468 nm (the maximum of the camphorquinone absorption coefficient), with 20-ns pulse duration, repetition rate of 10 Hz and energy of 10 mJ per pulse, was used as a light source. The aim of the study was to evaluate the effect of polymerization of light and dark shades of three different hybrid composites cured by pulsed laser at the surface and at 3.0 mm depth. The degree of conversion was measured by Fourier transform infrared spectroscopy (FTIR). Applying pulsed blue laser, significantly better results were obtained for both shades compared to standard polymerization values. Very weak dependence of the degree of conversion, between the surface measurements and those at 3.0 mm, were observed in the case of pulsed laser polymerization due to the piercing nanopulses and the monochromatic light at 468 nm.  相似文献   

17.
The success of radiotherapy in eradicating tumours depends on the total radiation dose, but what limits this dose is the tolerance of the normal tissues within the treatment volume. Studies involving fibroblast survival have demonstrated the theoretical feasibility of a predictive assay of radiation sensitivity, but such an assay is still far from clinical application. Using pulsed-field gel electrophoresis (PFGE), we have quantified the initial "apparent" number of DNA double-strand breaks (dsb) induced by the radiation as an alternative measure of sensitivity in 2 different normal cell types from the same patients, epidermal skin cells and lymphocytes. We found significant inter-individual variation in the measured dsb (1-5 dsb/Gy/DNA unit). We also found a linear correlation between molecular damage in lymphocytes and skin samples from the same patient (slope = 0.83; r = 0.694; p = 0.0001). These results suggest that the initial number of dsb could be used as an indicator of the in vivo response to radiation.  相似文献   

18.
19.
Researchers have carried out a variety of investigations to determine the properties of available dentin bonding systems. The test methods and variables used in 50 published investigations of bond strength were analyzed. Among the studies analyzed, shear tests predominated, being used in 80% of the studies; dentin from human molar teeth was used most often (in 88% of investigations); and the most prevalent time of testing was 24 hours postcuring. However, a number of potential variables were not recorded in a high proportion of articles, among these the film thickness, the type of dentin tested, and the surface condition (moist or dry). The mode of failure was recorded in only 42% of the investigations assessed. It was found that there is little standardization of test methods in studies of dentin bond strength and that a number of variables are often either not recorded or reported.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号