首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A microfluidic separation system is developed to perform two-dimensional differential gel electrophoretic (DIGE) separations of complex, cellular protein mixtures produced by induced protein expression in E. coli. The micro-DIGE analyzer is a two-layer borosilicate glass microdevice consisting of a single 3.75 cm long channel for isoelectric focusing, which is sampled in parallel by 20 channels effecting a second-dimension separation by native electrophoresis. The connection between the orthogonal separation systems is accomplished by smaller channels comprising a microfluidic interface (MFI) that prevents media leakage between the two dimensions and enables facile loading of discontinuous gel systems in each dimension. Proteins are covalently labeled with Cy2 and Cy3 DIGE and detected simultaneously with a rotary confocal fluorescence scanner. Reproducible two-dimensional separations of both purified proteins and complex protein mixtures are performed with minimal run-to-run variation by including 7 M urea in the second-dimension separation matrix. The capabilities of the micro-DIGE analyzer are demonstrated by following the induced expression of maltose binding protein in E. coli. Although the absence of sodium dodecyl sulfate (SDS) in the second-dimension sizing separation limits the orthogonality and peak capacity of the separation, this analyzer is a significant first step toward the reproducible two-dimensional analysis of complex protein samples in microfabricated devices. Furthermore, the microchannel interface structures developed here will facilitate other multidimensional separations in microdevices.  相似文献   

2.
Wang YC  Choi MH  Han J 《Analytical chemistry》2004,76(15):4426-4431
Methods are described to achieve more efficient multidimensional protein separation in a microfluidic channel. The new methods couple isoelectric focusing (IEF) with high ionic strength electrophoretic separations by active microvalve control in a microchip. Several experiments demonstrating independent 2D separation were performed, and critical parameters for optimal chip performance were identified, including channel passivation, electroosmosis control, and IEF linearity control. This strategy can be used for integration of different heterogeneous separation techniques, such as IEF, capillary electrophoresis, and liquid chromatography. This new device can be ideal for preseparation and preconcentration of complex biomolecule samples for a streamlined biomolecule analysis using mass spectrometry.  相似文献   

3.
The work presented herein describes highly efficient, two-dimensional (2D) electrophoretic separations of proteins in a PMMA-based microchip. Sodium dodecyl sulfate microcapillary gel electrophoresis (SDS micro-CGE) and micellar electrokinetic chromatography (MEKC) were used as the separation modes for the first and second dimension of the electrophoresis, respectively. The microchip was prepared by hot embossing into PMMA from a brass mold master fabricated via high-precision micromilling. The microchip incorporated a 30-mm SDS micro-CGE and a 10-mm MEKC dimension length. Electrokinetic injection and separation were used with field strengths of up to 400 V/cm. Alexa Fluor 633 conjugated proteins, ranging in size from 38 to 110 kDa, were detected using laser-induced fluorescence with excitation/emission at 633/652 nm. Average plate numbers (N) of 4.8 x 10(4) and 1.2 x 10(4) were obtained in the SDS micro-CGE and MEKC separation dimensions, respectively, for the investigated proteins corresponding to plate heights (H) of 0.62 and 0.87 microm. Effluents from the first dimension (SDS micro-CGE) were repetitively transferred into the second dimension every 0.5 s of run time in the first dimension with the electrophoresis run time in the MEKC dimension being 10 s. The 2D separation was performed on the investigated proteins in approximately 12 min and provided a peak capacity of approximately 1000.  相似文献   

4.
Ultra-thin-layer SDS gel electrophoresis in conjunction with automated laser-induced fluorescence detection is a novel and powerful method for the analysis of fluorophore-labeled proteins. The technique described in this paper employs instant, noncovalent fluorophore labeling by the addition of a fluorescent staining dye to the sample proteins either during or immediately prior to the sample loading process. Thus, the method does not require time-consuming post- or preseparation staining/labeling. By combining the multilane format of SDS polyacrylamide slab gel electrophoresis and the high separation efficiency of capillary SDS gel electrophoresis, ultra-thin-layer SDS gel electrophoresis features rapid, high-throughput, and high-resolution analysis of proteins in the molecular mass range of 14-116 kDa. The good heat dissipation inherent to the ultrathin format enables the use of agarose and agarose-based composite separation matrixes, which can be easily replaced within the separation platform. Labeling efficiency as a function of the concentration of the staining dye, SDS, and proteins is thoroughly discussed. Detection sensitivity of the method was found to be at the low-femtomole level (1.25 ng/band), determined by analyzing a set of serial dilutions of standard proteins. Practical example of molecular mass determination and characterization of a complex protein mixture are also shown.  相似文献   

5.
Gao J  Xu J  Locascio LE  Lee CS 《Analytical chemistry》2001,73(11):2648-2655
An integrated platform is presented for rapid and sensitive protein identification by on-line protein digestion and analysis of digested proteins using electrospray ionization mass spectrometry or transient capillary isotachophoresis/capillary zone electrophoresis with mass spectrometry detection. A miniaturized membrane reactor is constructed by fabricating the microfluidic channels on a poly(dimethylsiloxane) substrate and coupling the microfluidics to a poly(vinylidene fluoride) porous membrane with the adsorbed trypsin. On the basis of he large surface area-to-volume ratio of porous membrane media, adsorbed trypsin onto the poly(vinylidene fluoride) membrane is employed for achieving ultrahigh catalytic turnover. The extent of protein digestion in a miniaturized membrane reactor can be directly controlled by the residence time of protein analytes inside the trypsin-adsorbed membrane, the reaction temperature, and the protein concentration. The resulting peptide mixtures can either be directly analyzed using electrospray ionization mass spectrometry or further concentrated and resolved by electrophoretic separations prior to the mass spectrometric analysis. This microfluidic system enables rapid identification of proteins in minutes instead of hours, consumes very little sample (nanogram or less), and provides on-line interface with upstream protein separation schemes for the analysis of complex protein mixtures such as cell lysates.  相似文献   

6.
Miniaturized electrophoresis was successfully coupled with native fluorescence detection for direct analysis of proteins in one- and two-dimensional separations. The detection setup was based on direct observation of the UV-induced fluorescence of proteins using a CCD camera and a Hg (Xe) lamp for sample excitation. Protein mixtures were readily separated by size on a 1-cm segment of the one-dimensional gel in 8 min, and a detection limit of 0.04 ng per band was achieved. The dynamic range of the system was larger than 2 orders of magnitude. Miniaturized slab gel electrophoresis was performed on a special holder designed to couple isoelectric focusing with SDS-PAGE. Two-dimensional separation, including rehydration of IEF strip and fluorescence detection was completed in 2.5 h. Approximately 200 protein spots from Escherichia coli were detected on a 1 cm(2) area. A detection limit of 0.1 microg of total protein was achieved. The operation should be amenable to total automation.  相似文献   

7.
We have developed an acrylic microfluidic device that sequentially couples liquid-phase isoelectric focusing (IEF) and free solution capillary electrophoresis (CE). Rapid separation (<1 min) and preconcentration (73x) of species were achieved in the initial IEF dimension. Using full-field fluorescence imaging, we observed nondispersive mobilization velocities on the order of 20 microm/s during characterization of the IEF step. This transport behavior allowed controlled electrokinetic mobilization of focused sample bands to a channel junction, where voltage switching was used to repeatedly inject effluent from the IEF dimension into an ampholyte-based CE separation. This second dimension was capable of analyzing all fluid volumes of interest from the IEF dimension, as IEF was 'parked' during each CE analysis and refocused prior to additional CE analyses. Investigation of each dimension of the integrated system showed time-dependent species displacement and band-broadening behavior consistent with IEF and CE, respectively. The peak capacity of the 2D system was approximately 1300. A comprehensive 2D analysis of a fluid volume spanning 15% of the total IEF channel length was completed in less than 5 min.  相似文献   

8.
As a part of an ongoing investigation of the use of isoelectric focusing (IEF) in microfluidic devices, pH gradients were electrochemically formed and optically quantified in microfluidic channels using acid-base indicators. The microchannels consisted of two parallel 40-mm-long electrodes with an interelectrode gap of 2.54 mm; top and bottom transparent windows were separated by 0.2 mm. Gradients in pH were formed as a result of the electrochemical decomposition of water at an applied potential not higher than 2.5 V to avoid generation of gas bubbles. Solutions contained low concentrations of a single buffer. The stability of the pH gradients and their sensitivity to changes in initial conditions were investigated under static (nonflow) conditions. Isoelectric focusing of sample biological analytes, bovine hemoglobin and bovine serum albumin, was performed to illustrate the potential of "microfluidic transverse IEF" for use in continuous concentration and separation systems.  相似文献   

9.
A 16-channel microfluidic chip with an integrated contact conductivity sensor array is presented. The microfluidic network consisted of 16 separation channels that were hot-embossed into polycarbonate (PC) using a high-precision micromilled metal master. All channels were 40 microm deep and 60 microm wide with an effective separation length of 40 mm. A gold (Au) sensor array was lithographically patterned onto a PC cover plate and assembled to the fluidic chip via thermal bonding in such a way that a pair of Au microelectrodes (60 microm wide with a 5 microm spacing) was incorporated into each of the 16 channels and served as independent contact conductivity detectors. The spacing between the corresponding fluidic reservoirs for each separation channel was set to 9 mm, which allowed for loading samples and buffers to all 40 reservoirs situated on the microchip in only five pipetting steps using an 8-channel pipettor. A printed circuit board (PCB) with platinum (Pt) wires was used to distribute the electrophoresis high-voltage to all reservoirs situated on the fluidic chip. Another PCB was used for collecting the conductivity signals from the patterned Au microelectrodes. The device performance was evaluated using microchip capillary zone electrophoresis (mu-CZE) of amino acid, peptide, and protein mixtures as well as oligonucleotides that were separated via microchip capillary electrochromatography (mu-CEC). The separations were performed with an electric field (E) of 90 V/cm and were completed in less than 4 min in all cases. The conductivity detection was carried out using a bipolar pulse voltage waveform with a pulse amplitude of +/-0.6 V and a frequency of 6.0 kHz. The conductivity sensor array concentration limit of detection (SNR = 3) was determined to be 7.1 microM for alanine. The separation efficiency was found to be 6.4 x 10(4), 2.0 x 10(3), 4.8 x 10(3), and 3.4 x 10(2) plates for the mu-CEC of the oligonucleotides and mu-CZE of the amino acids, peptides, and proteins, respectively, with an average channel-to-channel migration time reproducibility of 2.8%. The average resolution obtained for mu-CEC of the oligonucleotides and mu-CZE of the amino acids, peptides, and proteins was 4.6, 1.0, 0.9, and 1.0, respectively. To the best of our knowledge, this report is the first to describe a multichannel microchip electrophoresis device with integrated contact conductivity sensor array.  相似文献   

10.
A method for carrying out 2D gel electrophoresis in a capillary format is presented. In this method, separation in the first dimension is carried out in a 1D capillary, with this system physically isolated from the capillaries that provide the separation in the second dimension. After completion of the first separation, the 1D channel is physically connected to the 2D capillaries, and a second separation is carried out in an orthogonal set of parallel capillaries. The ability of poly(dimethylsiloxane) (PDMS) to support the fabrication of 3D microfluidic systems makes it possible to produce membranes that both enclose the gel used in the first separation in a capillary and provide passages for the proteins to migrate into the array of orthogonal capillaries. The elastomeric nature of PDMS makes it possible to make reversible connections between pieces of PDMS. The feasibility of this system is demonstrated using a protein mixture containing fluorescein-conjugated carbonic anhydrase, fluorescein-conjugated BSA, and Texas Red-conjugated ovalbumin. This work suggests one type of design that might form the basis for a microfabricated device for 2D capillary electrophoresis.  相似文献   

11.
A comprehensive on-line two-dimensional 2D-HPLC system with integrated sample preparation was developed for the analysis of proteins and peptides with a molecular weight below 20 kDa. The system setup provided fast separations and high resolving power and is considered to be a complementary technique to 2D gel electrophoresis in proteomics. The on-line system reproducibly resolved approximately 1000 peaks within the total analysis time of 96 min and avoided sample losses by off-line sample handling. The low-molecular-weight target analytes were separated from the matrix using novel silica-based restricted access materials (RAM) with ion exchange functionalities. The size-selective sample fractionation step was followed by anion or cation exchange chromatography as the first dimension. The separation mechanism in the subsequent second dimension employed hydrophobic interactions using short reversed-phase (RP) columns. A new column-switching technique, including four parallel reversed-phase columns, was employed in the second dimension for on-line fractionation and separation. Gradient elution and UV detection of two columns were performed simultaneously while loading the third and regenerating the fourth column. The total integrated workstation was operated in an unattended mode. Selected peaks were collected and analyzed off-line by MALDI-TOF mass spectrometry. The system was applied to protein mapping of biological samples of human hemofiltrate as well as of cell lysates originating from a human fetal fibroblast cell line, demonstrating it to be a viable alternative to 2D gel electrophoresis for mapping peptides and small proteins.  相似文献   

12.
A novel method for performing electrophoretic separations is described-gradient elution moving boundary electrophoresis (GEMBE). The technique utilizes the electrophoretic migration of chemical species in combination with variable hydrodynamic bulk counterflow of the solution through a separation capillary or microfluidic channel. Continuous sample introduction is used, eliminating the need for a sample injection mechanism. Only analytes with an electrophoretic velocity greater than the counterflow velocity enter the separation channel. The counterflow velocity is varied over time so that each analyte is brought into the separation column at different times, allowing for high-resolution separations in very short channels. The new variable of bulk flow acceleration affords a new selectivity parameter to electrophoresis analogous to gradient elution compositions in chromatography. Because it does not require extra channels or access ports to form an injection zone and because separations can be performed in very short channels, GEMBE separations can be implemented in much smaller areas on a micro-fluidic chip as compared to conventional capillary electrophoresis. Demonstrations of GEMBE separations of small dye molecules, amino acids, DNA, and immunoassay products are presented. A low-cost, polymeric, eight-channel multiplexed microfluidic device was fabricated to demonstrate the reduced area requirements of GEMBE; the device was less than 1 in.2 in area and required only n + 1 fluidic access ports per n analyses (in this instance, nine ports for eight analyses). Parallel separations of fluorescein and carboxyfluorescein yielded less than 3% relative standard deviation (RSD) in interchannel migration times and less than 5% RSD in both peak and height measurements. The device was also used to generate a calibration curve for a homogeneous insulin immunoassay using each of the eight channels as a calibration point with less than 5% RSD at each point with replicate analyses.  相似文献   

13.
Qu H  Wang H  Huang Y  Zhong W  Lu H  Kong J  Yang P  Liu B 《Analytical chemistry》2004,76(21):6426-6433
Chemical modification of a poly(methyl methacrylate) (PMMA) microchannel surface has been explored to functionalize microfluidic chip systems. A craft copolymer was designed and synthesized to introduce the silane functional groups onto the plastic surface first. Furthermore, it has been found that, through a silicon-oxygen-silicon bridge that formed by tethering to these functional groups, a stable patterning network of gel matrix could be achieved. Thus, anchorage of proteins could be realized onto the hydrophobic PMMA microchannels with bioactivity preserved as far as possible. The protein homogeneous patterning in a microfluidic channel has been demonstrated by performing microchip capillary electrophoresis with laser-induced fluorescence detection and confocal fluorescence microscopy. To investigate the bioactivity of enzymes entrapped within stable silica gel-derived microchannels, the suggested scheme was employed to the construction of immobilized enzyme microreactor-on-a-chip. The proteolytic activity of immobilized trypsin has been demonstrated with the digestion of cytochrome c and bovine serum albumin at a fast flow rate of 4.0 microL/min, which affords the short residence time less than 5 s. The digestion products were characterized using MALDI-TOF MS with sequence coverage of 75 and 31% observed, respectively. This research exhibited a simple but effective strategy of plastic microchip surface modification for protein immobilization in biological and proteomic research.  相似文献   

14.
Some basic aspects of capillary electrophoresis (CE) separations on a poly(methyl methacrylate) chip provided with two separation channels in the column-coupling (CC) configuration and on-column conductivity detectors were studied. The CE methods employed in this study included isotachophoresis (ITP), capillary zone electrophoresis (CZE), and CZE with on-line ITP sample pretreatment (ITP-CZE). Hydrodynamic and electroosmotic flows of the solution in the separation compartment of the chip were suppressed, and electrophoresis was a dominant transport process in the separations performed by these methods. Very reproducible migration velocities of the separated constituents were typical under such transport conditions, and consequently, test analytes could be quantified by various ITP techniques with 1-2% RSD. The CC configuration of the separation channels provides means for an effective combination of an enhanced load capacity of the separation system with high detection sensitivities for the analytes in concentration-cascade ITP separations. In this way, for example, succinate, acetate, and benzoate could be separated also in instances when they were present in the loaded sample (1.2 microL) at 1 mmol/L concentrations while their limits of detection ranged from 8 to 12 micromol/L concentrations. A well-defined ITP concentration of the analyte(s) combined with an in-column sample cleanup (via an electrophoretically driven removal of the matrix constituents from the separation compartment) can be integrated into the separations performed on the CC chip. These sample pretreatment capabilities were investigated in ITP-CZE separations of model samples in which nitrite, phosphate, and fluoride (each at a 10 micromol/L concentration) accompanied matrix constituents (sulfate and chloride) at considerably higher concentrations. Here, both the concentration of the analytes and cleanup of the sample were included in the ITP separation in the first separation channel while the second separation channel served for the CZE separation of the ITP pretreated sample and the detection of the analytes.  相似文献   

15.
Although well-established as a technique for protein purification, the application of continuous elution tube gel electrophoresis to proteome fractionation remains problematic. Difficulties associated with sample collection, particularly at the high mass range or at low sample loadings, continue to plague the technique. Furthermore, an upper mass limit is imposed as slow-moving higher molecular weight proteins are progressively diluted during the collection phase. In short, with current technology, effective separation over a broad mass range has not been achieved. In this work, we present improved techniques for continuous elution tube gel electrophoresis to accommodate broad mass range separation of proteins. Our device enables rapid partitioning of a proteome into discrete mass range fractions in the solution phase. High recovery is achieved at submicrogram to milligram sample loadings. We demonstrate comprehensive, reproducible separations of protein mixtures, as well as separation of a proteome in as fast as 1 h, over mass ranges from below 10 to 250 kDa. Finally, we identified proteins from a prefractionated standard protein mixture using liquid chromatography tandem mass spectrometric (LC-MS/MS) analysis.  相似文献   

16.
This paper reports a protocol that improves the resolving power of isoelectric focusing (IEF) in a polymeric microfluidic chip. This method couples several stages of IEF in series by first focusing proteins in a straight channel using broad-range ampholytes and then refocusing segments of the first channel into secondary channels that branch from the first one at T-junctions. Experiments demonstrate that several fluorescent proteins that had focused within a segment of the straight channel in the first stage were refocused at significantly higher resolution due to the shallower pH gradient and higher electrical field gradient. Two variants of green fluorescent protein from the second-stage IEF fractionation were further separated in a third stage. Three stages of IEF were completed in less than 25 min at electric field strengths ranging from 50 to 214 V/cm.  相似文献   

17.
The extension of microfluidic devices to include three-dimensional fluidic networks allows complex fluidic and chemical manipulations but requires innovative methods to interface fluidic layers. Externally controllable interconnects, employing nuclear track-etched polycarbonate membranes containing nanometer-diameter capillaries, are described that produce hybrid three-dimensional fluidic architectures. Controllable nanofluidic transfer is achieved by controlling applied bias, polarity, and density of the immobile nanopore surface charge and the impedance of the nanocapillary array relative to the microfluidic channels. Analyte transport between vertically separated microchannels has three stable transfer levels, corresponding to zero, reverse, and forward bias. The transfer can even depend on the properties of the analyte being transferred such as the molecular size, illustrating the flexible character of the analyte transfer. In a specific analysis implementation, nanochannel array gating is applied to capillary electrophoresis separations, allowing selected separated components to be isolated for further manipulation, thereby opening the way for preparative separations at attomole analyte mass levels.  相似文献   

18.
Microfabricated system for parallel single-cell capillary electrophoresis   总被引:4,自引:0,他引:4  
Munce NR  Li J  Herman PR  Lilge L 《Analytical chemistry》2004,76(17):4983-4989
Performing single-cell electrophoresis separations using multiple parallel microchannels offers the possibility of both increasing throughput and eliminating cross-contamination between different separations. The instrumentation for such a system requires spatial and temporal control of both single-cell selection and lysis. To address these problems, a compact platform is presented for single-cell capillary electrophoresis in parallel microchannels that combines optical tweezers for cell selection and electromechanical lysis. Calcein-labeled acute myloid leukemia (AML) cells were selected from an on-chip reservoir and transported by optical tweezers to one of four parallel microfluidic channels. Each channel entrance was manufactured by F2-laser ablation to form a 20- to 10-microm tapered lysis reservoir, creating an injector geometry effective in confining the cellular contents during mechanical shearing of the cell at the 10-microm capillary entrance. The contents of individual cells were simultaneously injected into parallel channels resulting in electrophoretic separation as recorded by laser-induced fluorescence of the labeled cellular contents.  相似文献   

19.
Analysis of protein and peptide mixtures via capillary electrophoresis is hindered by nonspecific adsorption of analytes to the capillary walls, resulting in poor separations and quantitative reproducibility. Phospholipid bilayer (PLB) coatings are very promising for improving protein and peptide separations due to the native resistance to nonspecific protein adsorption offered by PLBs; however, these coatings display limited chemical and temporal stability. Here, we show the preparation and characterization of a highly cross-linked, polymerized phospholipid capillary coating prepared using bis-SorbPC. Poly(bis-SorbPC) PLB coatings are prepared in situ within fully enclosed fused silica capillaries via self-assembly and radical polymerization. Polymerization of the PLB coating stabilizes the membrane against desorption from the surface and migration in an electric field, improves the temporal and chemical stability, and allows for the separation of both cationic and anionic proteins, while preserving the native resistance to nonspecific protein adsorption of natural PLBs.  相似文献   

20.
Here we present an integrated microfluidic device for rapid and automated isolation and quantification of glycoprotein biomarkers directly from biological samples on a multidimensional analysis platform. In the first dimension, digital isoelectric fractionation (dIEF) uses discrete pH-specific membranes to separate proteins and their isoforms into precise bins in a highly flexible spatial arrangement on-chip. dIEF provides high sample preconcentration factors followed by immediate high-fidelity transfer of fractions for downstream analysis. We successfully fractionate isoforms of two potential glycoprotein cancer markers, fetuin and prostate-specific antigen (PSA), with 10 min run time, and results are compared qualitatively and quantitatively to conventional slab gel IEF. In the second dimension, functionalized monolithic columns are used to capture and detect targeted analytes from each fraction. We demonstrate rapid two-dimensional fractionation, immunocapture, and detection of C-reactive protein (CRP) spiked in human serum. This rapid, flexible, and automated approach is well-suited for glycoprotein biomarker research and verification studies and represents a practical avenue for glycoprotein isoform-based diagnostic testing.  相似文献   