首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
New recording techniques for detecting surface electromyographic (EMG) signals based on concentric-ring electrodes are proposed in this paper. A theoretical study of the two-dimensional (2-D) spatial transfer function of these recording systems is developed both in case of rings with a physical dimension and in case of line rings. Design criteria for the proposed systems are presented in relation to spatial selectivity. It is shown that, given the radii of the rings, the weights of the spatial filter can be selected in order to improve the rejection of low spatial frequencies, thus increasing spatial selectivity. The theoretical transfer functions of concentric systems are obtained and compared with those of other detection systems. Signals detected with the ring electrodes and with traditional one-dimensional and 2-D systems are compared. The concentric-ring systems show higher spatial selectivity with respect to the traditional detection systems and reduce the problem of electrode location since they are invariant to rotations. The results shown are very promising for the noninvasive detection of single motor unit (MU) activities and decomposition of the surface EMG signal into the constituent MU action potential trains.  相似文献   

2.
A new class of spatial filters for surface electromyographic (EMG) signal detection is proposed. These filters are based on the 2-D spatial wavelet decomposition of the surface EMG recorded with a grid of electrodes and inverse transformation after zeroing a subset of the transformation coefficients. The filter transfer function depends on the selected mother wavelet in the two spatial directions. Wavelet parameterization is proposed with the aim of signal-based optimization of the transfer function of the spatial filter. The optimization criterion was the minimization of the entropy of the time samples of the output signal. The optimized spatial filter is linear and space invariant. In simulated and experimental recordings, the optimized wavelet filter showed increased selectivity with respect to previously proposed filters. For example, in simulation, the ratio between the peak-to-peak amplitude of action potentials generated by motor units 20 degrees apart in the transversal direction was 8.58% (with monopolar recording), 2.47% (double differential), 2.59% (normal double differential), and 0.47% (optimized wavelet filter). In experimental recordings, the duration of the detected action potentials decreased from (mean +/- SD) 6.9 +/- 0.3 ms (monopolar recording), to 4.5 +/- 0.2 ms (normal double differential), 3.7 +/- 0.2 (double differential), and 3.0 +/- 0.1 ms (optimized wavelet filter). In conclusion, the new class of spatial filters with the proposed signal-based optimization of the transfer function allows better discrimination of individual motor unit activities in surface EMG recordings than it was previously possible.  相似文献   

3.
This paper presents a method to decompose multichannel long-term intramuscular electromyogram (EMG) signals. In contrast to existing decomposition methods which only support short registration periods or single-channel recordings of signals of constant muscle effort, the decomposition software EMG-LODEC (ElectroMyoGram LOng-term DEComposition) is especially designed for multichannel long-term recordings of signals of slight muscle movements. A wavelet-based, hierarchical cluster analysis algorithm estimates the number of classes [motor units (MUs)], distinguishes single MUAPs from superpositions, and sets up the shape of the template for each class. Using three channels and a weighted averaging method to track action potential (AP) shape changes improve the analysis. In the last step, nonclassified segments, i.e., segments containing superimposed APs, are decomposed into their units using class-mean signals. Based on experiments on simulated and long-term recorded EMG signals, our software is capable of providing reliable decompositions with satisfying accuracy. EMG-LODEC is suitable for the study of MU discharge patterns and recruitment order in healthy subjects and patients during long-term measurements.  相似文献   

4.
As more and more intramuscular electromyogram (EMG) decomposition programs are being developed, there is a growing need for evaluating and comparing their performances. One way to achieve this goal is to generate synthetic EMG signals having known features. Features of interest are: the number of channels acquired (number of detection surfaces), the number of detected motor unit action potential (MUAP) trains, their time-varying firing rates, the degree of shape similarity among MUAPs belonging to the same motor unit (MU) or to different MUs, the degree of MUAP superposition, the MU activation intervals, the amount and type of additive noise. A model is proposed to generate one or more channels of intramuscular EMG starting from a library of real MUAPs represented in a 16-dimensional space using their Associated Hermite expansion. The MUAP shapes, regularity of repetition rate, degree of superposition, activation intervals, etc. may be time variable and are described quantitatively by a number of parameters which define a stochastic process (the model) with known statistical features. The desired amount of noise may be added to the synthetic signal which may then be processed by the decomposition algorithm under test to evaluate its capability of recovering the signal features.  相似文献   

5.
In the present study, different isotropic and anisotropic filters have been compared by means of theoretical field simulations and experiments in volunteers. A tripole model for an excited motor unit (MU) was used as the basis for simulating the spatial extension of the filter response for each of the investigated filters. The spatial extension is an indicative of the spatial resolution. For the experimental validation, the total number of single motor units was not directly investigated, but the signal-to-noise ratio (SNR) has been determined. Therefore, the potential distribution generated on the skin surface during maximum voluntary contraction has been simultaneous spatially filtered with each of the investigated filters. The simulations show that an isotropic spatial filtering procedure reduces the spatial extension of the filter response and improves the spatial resolution of the electromyography (EMG)-recording arrangement in comparison to anisotropic spatial filters up to 30%. In other words, the spatial selectivity of the arrangement is increased. This improvement in the filter performance is more pronounced for MU's located close to the skin surface than for MU's more distantly located. Additionally, this theoretical improvement in selectivity depends on the direction of the excitation spread relative to the filter alignment. However, the investigations also show that isotropic filters offer an advantage, compared to anisotropic filters, only when the investigated MU is located extremely close to the filter input. The results of the simulations can be confirmed by the experimental investigations. An improvement of 11% in the SNR, relative to anisotropic spatial filters, can be established when using an isotropic spatial filter. This experimental improvement in selectivity is less than the theoretical improvement because the experimentally investigated MU's have less portion in the anisotropic range of the filters than the simulated one at best  相似文献   

6.
This study introduces the application of nonlinear spatial filters to help identify single motor unit discharge from multiple channel surface electromyogram (EMG) signals during low force contractions. The nonlinear spatial filters simultaneously take into account the instantaneous amplitude and frequency information of a signal. This property was used to enhance motor unit action potentials (MUAPs) in the surface EMG record. The advantages of nonlinear spatial filtering for surface MUAP enhancement were investigated using both simulation and experimental approaches. The simulation results indicate that when compared with various linear spatial filters, nonlinear spatial filtering achieved higher SNR and higher kurtosis of the surface EMG distribution. Over a broad range of SNR and kurtosis levels for the input signal, nonlinear spatial filters achieved at least 32 times greater SNR and 11% higher kurtosis for correlated noise, and at least 15 times greater SNR and 1.7 times higher kurtosis for independent noise, across electrode array channels. The improvements offered by nonlinear spatial filters were further documented by applying them to experimental surface EMG array recordings. Compared with linear spatial filters, nonlinear spatial filters achieved at least nine times greater SNR and 25% higher kurtosis. It follows that nonlinear spatial filters represent a potentially useful supplement to linear spatial filters for detection of motor unit activity in surface EMG at low force contractions.  相似文献   

7.
We describe a new method for the estimation of muscle fiber conduction velocity (CV) from surface electromyography (EMG) signals. The method is based on the detection of two surface EMG signals with different spatial filters and on the compensation of the spatial filtering operations by two temporal filters (with CV as unknown parameter) applied to the signals. The transfer functions of the two spatial filters may have different magnitudes and phases, thus the detected signals have not necessarily the same shape. The two signals are first spatially and then temporally filtered and are ideally equal when the CV value selected as a parameter in the temporal filters corresponds to the velocity of propagation of the detected action potentials. This approach is the generalization of the classic spectral matching technique. A theoretical derivation of the method is provided together with its fast implementation by an iterative method based on the Newton's method. Moreover, the lowest CV estimate among those obtained by a number of filter pairs is selected to reduce the CV bias due to nonpropagating signal components. Simulation results indicate that the method described is less sensitive than the classic spectral matching approach to the presence of nonpropagating signals and that the two methods have similar standard deviation of estimation in the presence of additive, white, Gaussian noise. Finally, experimental signals have been collected from the biceps brachii muscle of ten healthy male subjects with an adhesive linear array of eight electrodes. The CV estimates depended on the electrode location with positive bias for the estimates from electrodes close to the innervation or tendon regions, as expected. The proposed method led to significantly lower bias than the spectral matching method in the experimental conditions, confirming the simulation results.  相似文献   

8.
The detection volume of the surface electromyographic (EMG) signal was explored using a finite-element model, to examine the feasibility of obtaining independent myoelectric control signals from regions of reinnervated muscle. The selectivity of the surface EMG signal was observed to decrease with increasing subcutaneous fat thickness. The results confirm that reducing the interelectrode distance or using double-differential electrodes can increase surface EMG selectivity in an inhomogeneous volume conductor. More focal control signals can be obtained, at the expense of increased variability, by using the mean square value, rather than the root mean square or average rectified value.  相似文献   

9.
The speed of propagation of an action potential along a muscle fiber, its conduction velocity (CV), can be used as an indication of the physiological or pathological state of the muscle fiber membrane. The motor unit action potential (MUAP), the waveform resulting from the spatial and temporal summation of the individual muscle fiber action potentials of that motor unit (MU), propagates with a speed referred to as the motor unit conduction velocity (MUCV). This paper introduces a new algorithm, the MU tracking algorithm, which estimates MUCVs and MUAP amplitudes for individual MUs in a localized MU population using SEMG signals. By tracking these values across time, the electrical activity of the localized MU pool can be monitored. An assessment of the performance of the algorithm has been achieved using simulated SEMG signals. It is concluded that this analysis technique enhances the suitability of SEMG for clinical applications and points toward a future of noninvasive diagnosis and assessment of neuromuscular disorders.  相似文献   

10.
The contribution of motor unit action potential trains (MUAPT) of distinct motor units (MU) to the crosscorrelation function between myoelectric signals (MES) recorded at the skin surface is studied. In specific, the significance of the correlation between the firing activity of concurrently active MUs (which results in cross-terms in the overall correlation function) is compared to the representation obtained using the contributions of single MUs at each recording site (auto-terms). A model for the generation of surface MUAPs is combined with the generation of MU firing statistics in order to obtain surface MUAPTs. MU firing statistics are simulated to incorporate MU synchronization levels reported in the literature. Alternatively, experimental firing statistics are fed to the model generating the MUAPTs. The contribution of individual MU pairs to the global myoelectric signal correlation function is assessed. Results indicate that the cross-terms from different MUs decrease steadily contributing very little to the overall correlation for record lengths as short as 30 s. Thus, the error expected when computing the crosscorrelation function between two channels of MES as the superposition of the auto-terms contributed by single MUs (i.e., ignoring the cross-terms from different MUs) is shown to be very small.  相似文献   

11.
Physiologically based simulation of clinical EMG signals   总被引:1,自引:0,他引:1  
An algorithm that generates electromyographic (EMG) signals consistent with those acquired in a clinical setting is described. Signals are generated using a model constructed to closely resemble the physiology and morphology of skeletal muscle, combined with line source models of commonly used needle electrodes positioned in a way consistent with clinical studies. The validity of the simulation routines is demonstrated by comparing values of statistics calculated from simulated signals with those from clinical EMG studies of normal subjects. The simulated EMG signals may be used to explore the relationships between muscle structure and activation and clinically acquired EMG signals. The effects of motor unit (MU) morphology, activation, and neuromuscular junction activity on acquired signals can be analyzed at the fiber, MU and muscle level. Relationships between quantitative features of EMG signals and muscle structure and activation are discussed.  相似文献   

12.
Muscle fiber conduction velocity (CV) can be estimated by the application of a pair of spatial filters to surface electromagnetic (EMG) signals and compensation of the spatial filter transfer function with equivalent temporal filters. This method integrates the selection of the spatial filters for signal detection to the estimation of CV. Using this approach, in this paper, we propose a novel technique for signal-based selection of the spatial filter pair that minimizes the effect of nonpropagating signal components (end-of-fiber effects) on CV estimates (optimal filters). The technique is applicable to signals with one propagating and one nonpropagating component, such as single motor unit action potentials. It is shown that the determination of the optimal filters also allows the identification of the propagating and nonpropagating signal components. The new method was applied to simulated and experimental EMG signals. Simulated signals were generated by a cylindrical, layered volume conductor model. Experimental signals were recorded from the abductor pollicis brevis with a linear array of 16 electrodes. In the simulations, the proposed approach provided CV estimates with lower bias due to nonpropagating signal components than previously proposed methods based on the entire signal waveform. In the experimental signals, the technique separated propagating and nonpropagating signal components with an average reconstruction error of 2.9 +/- 0.9% of the signal energy. The technique may find application in single motor unit studies for decreasing the variability and bias of CV estimates due to the presence and different weights of the nonpropagating components.  相似文献   

13.
This study analytically describes surface electromyogram (EMG) signals generated by a planar multilayer volume conductor constituted by different subdomains modeling muscle, bone (or blood vessel), fat, and skin tissues. The bone is cylindrical in shape, with a semicircular section. The flat portion of the boundary of the bone subdomain is interfaced with the fat layer tissue, the remaining part of the boundary is in contact with the muscle layer. The volume conductor is a model of physiological tissues in which the bone is superficial, as in the case of the tibia bone, backbone, and bones of the forearm. The muscle fibers are considered parallel to the axes of the bone, so that the model is space invariant in the direction of propagation of the action potential. The proposed model, being analytical, allows faster simulations of surface EMG with respect to previously developed models including bone or blood vessels based on the finite-element method. Surface EMG signals are studied by simulating a library of single-fiber action potentials (SFAP) of fibers in different locations within the muscle domain, simulating the generation, propagation, and extinction of the action potential. The decay of the amplitude of the SFAPs in the direction transversal to the fibers is assessed. The decay in the direction of the bone has a lower rate with respect to the opposite direction. Similar results are obtained by simulating motor unit action potentials (MUAPs) constituted by 100 fibers with territory 5 mm2. M waves and interference EMG signals are also simulated based on the library of SFAPs. Again, the decay of the amplitude of the simulated interference EMG signals is lower approaching the bone with respect to going farther from it. The findings of this study indicate the effect of a superficial bone in enhancing the EMG signals in the transversal direction with respect to the fibers of the considered muscle. This increases the effect of crosstalk. The same mathematical method used to simulate a superficial bone can be applied to simulate other physiological tissues. For example, superficial blood vessels (e.g., basilic vein, brachial artery) can influence the recorded EMG signals. As the electrical conductivity of blood is high (it is of the same order as the longitudinal conductivity in the muscle), the effect on EMG signals is opposite compared to the effect of a superficial bone.  相似文献   

14.
Simulation Techniques in Electromyography   总被引:4,自引:0,他引:4  
A motor unit action potential (MUAP) recorded in clinical electromyography (EMG) is the spatial and temporal summation of the action potentials (AP's) from all muscle fibers in a motor unit (MU). An important determinant of MUAP waveform characteristics is the size of the recording electrode. In this paper, we have described the use of a modified line source model of single muscle fiber action potentials to simulate MUAP's as recorded by single fiber (SF) EMG, concentric needle (CN) EMG, and macro-EMG electrodes. Results indicate that SFEMG recordings from a normal MU contain mainly the AP's of the closest one to three muscle fibers of the MU. The amplitude, area, and duration of the simulated CNEMG MUAP's are determined mainly by the number and size of muscle fibers within a semicircular territory of 0.5, 1.5, and 2.5 mm, respectively, around the tip of the electrode. The amplitude and area of simulated macro-EMG MUAP's increase with the number of muscle fibers in the MU.  相似文献   

15.
The cell-free massive MIMO (multiple-input multiple-output) system involves a large number of access points serving a smaller number of mobile users (MUs) over identical time/ frequency resource. By providing large number of service antennas closer to the MUs, the cell-free massive MIMO can offer great spectral efficiency, better macro-diversity and minimal path loss. Despite several advantages, the cell-free massive MIMO suffers from energy overloading caused by uncontrolled backhaul power consumption for large number of distributed access points (APs) and pilot contamination during channel estimation. In this paper, we have taken into consideration a cell-free massive MIMO system with APs equipped with multiple antennas performing time-division-duplex (TDD) operation. Here, all the APs coordinate through a constrained backhaul network for joint transmission of signals to all the users simultaneously by multiplying the received signal with the normalized conjugate of the estimated channel state information (CSI) and send back a rounded off version of the weighted pattern to the central processing unit (CPU). Finally, an effective user defined algorithm is presented involving selection and grouping of various APs based on their individual contributions for a particular MU to improve the overall performance of the system.  相似文献   

16.
We propose a novel method for estimation of muscle fiber conduction velocity from surface electromyographic (EMG) signals. The method is based on the regression analysis between spatial and temporal frequencies of multiple dips introduced in the EMG power spectrum through the application of a set of spatial filters. This approach leads to a closed analytical expression of conduction velocity as a function of the auto- and cross-spectra of monopolar signals detected along the direction of muscle fibers. The performance of the algorithm was compared with respect to that of the classic single dip approach on simulated and experimental EMG signals. The standard deviation of conduction velocity estimates from simulated single motor unit action potentials was reduced from 1.51 m/s [10 dB signal-to-noise ratio (SNR)] and 1.06 m/s (20 dB SNR) with the single dip approach to 0.51 m/s (10 dB) and 0.23 m/s (20 dB) with the proposed method using 65 dips. When 200 active motor units were simulated in an interference EMG signal, standard deviation of conduction velocity decreased from 0.95 m/s (10 dB SNR) and 0.60 m/s (20 dB SNR) with a single dip to 0.21 m/s (10 dB) and 0.11 m/s (20 dB) with 65 dips. In experimental signals detected from the abductor pollicis brevis muscle, standard deviation of estimation decreased from (mean +/- SD over 5 subjects) 1.25 +/- 0.62 m/s with one dip to 0.10 +/- 0.03 m/s with 100 dips. The proposed method does not imply limitation in resolution of the estimated conduction velocity and does not require any iterative procedure for the estimate since it is based on a closed analytical formulation.  相似文献   

17.
In this paper, we propose techniques of surface electromyographic (EMG) signal detection and processing for the assessment of muscle fiber conduction velocity (CV) during dynamic contractions involving fast movements. The main objectives of the study are: 1) to present multielectrode EMG detection systems specifically designed for dynamic conditions (in particular, for CV estimation); 2) to propose a novel multichannel CV estimation method for application to short EMG signal bursts; and 3) to validate on experimental signals different choices of the processing parameters. Linear adhesive arrays of electrodes are presented for multichannel surface EMG detection during movement. A new multichannel CV estimation algorithm is proposed. The algorithm provides maximum likelihood estimation of CV from a set of surface EMG signals with a window limiting the time interval in which the mean square error (mse) between aligned signals is minimized. The minimization of the windowed mse function is performed in the frequency domain, without limitation in time resolution and with an iterative computationally efficient procedure. The method proposed is applied to signals detected from the vastus laterialis and vastus medialis muscles during cycling at 60 cycles/min. Ten subjects were investigated during a 4-min cycling task. The method provided reliable assessment of muscle fatigue for these subjects during dynamic contractions.  相似文献   

18.
Pattern recognition techniques have been applied to extract information from electromyographic (EMG) signals that can be used to control electrical powered hand prostheses. In this paper, optimized spatial filters that enhance separation properties of EMG signals are investigated. In particular, different multiclass extensions of the common spatial patterns algorithm are applied to high-density surface EMG signals acquired from the forearms of ten healthy subjects. Visualization of the obtained filter coefficients provides insight into the physiology of the muscles related to the performed contractions. The CSP methods are compared with a commonly used pattern recognition approach in a six-class classification task. Cross-validation results show a significant improvement in performance and a higher robustness against noise than commonly used pattern recognition methods.  相似文献   

19.
Two three-dimensional (3-D) under-decimated uniform discrete Fourier transform polyphase filter bank structures are proposed along with two applications: first, the sub-pixel motion discrimination of two-dimensional spatial objects moving with approximately constant local velocity in a noisy 3-D spatio-temporal image sequence and, second, the selective filtering of 3-D spatio-temporal broad-band plane waves based on their directions of arrival. The desired 3-D filter passband shapes are realized utilizing combinations of highly selective first-order 3-D infinite-impulse response frequency-planar filters in each band between the analysis and synthesis sections. Measured spatio-temporal performance confirms the high-quality broad-band transmission of passband signals, high directional selectivity and low computational complexity.  相似文献   

20.
Modeling of surface myoelectric signals. I. Model implementation   总被引:2,自引:0,他引:2  
The relationships between the parameters of active motor units (MU's) and the features of surface electromyography (EMG) signals have been investigated using a mathematical model that represents the surface EMG as a summation of contributions from the single muscle fibers. Each MU has parallel fibers uniformly scattered within a cylindrical volume of specified radius embedded in an anisotropic medium. Two action potentials, each modeled as a current tripole, are generated at the neuromuscular junction, propagate in opposite directions and extinguish at the fiber-tendon endings. The neuromuscular junctions and fiber-tendon endings are uniformly scattered within regions of specified width. Muscle fiber conduction velocity and average fiber length to the right and left of the center of the innervation zone are also specified. The signal produced by MU's with different geometries and conduction velocities are superimposed. Monopolar, single differential and double differential signals are computed from electrodes placed in equally spaced locations on the surface of the muscle and are displayed as functions of any of the model's parameters. Spectral and amplitude variables and conduction velocity are estimated from the surface signals and displayed as functions of any of the model's parameters. The influence of fiber-end effects, electrode misalignment, tissue anisotropy, MU's location and geometry are discussed. Part II of this paper will focus on the simulation and interpretation of experimental signals.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号