首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 645 毫秒
1.
PURPOSE: To evaluate different-caliber biopsy cutting needles in terms of the benefits and potential risk of bleeding in a swine model. MATERIALS AND METHODS: A total of 190 sequential liver biopsy specimens were obtained in 11 Yorkshire pigs (weight, 50-70 lb [22.5-31.5 kg]) by using 14-, 18-, and 20-gauge cutting needles. For each biopsy procedure, blood loss was determined by weighing sponges used to absorb bleeding, and sample-tissue DNA content was measured with spectrofluorometry. Analysis of variance was used to compare results. RESULTS: The larger the caliber of needle, the greater the absolute blood loss (for 14-gauge, 1.69 g; for 18-gauge, 0.74 g; for 20-gauge, 0.32 g) and DNA content per sample (for 14 gauge, 40.38 microg; for 18-gauge, 12.18 microg; for 20-gauge, 5.86 microg). The ratio of blood loss to amount of DNA recovered did not differ among the different-caliber needles. To obtain the same amount of diagnostic tissue, more passes were needed with the smaller-caliber needles. CONCLUSION: Use of larger-caliber needles is more efficient despite the greater amount of blood loss, because more tissue can be recovered and because fewer passes are necessary, which reduces the chances of complications.  相似文献   

2.
PURPOSE: To evaluate the usefulness of sonographically guided percutaneous biopsy of small lymph nodes in the abdomen, retroperitoneum, and pelvis. MATERIALS AND METHODS: From May 1995 through January 1997, 35 sonographically guided lymph node biopsies were performed in 34 patients. All biopsies were performed with a 20- (n = 18) or 22-gauge (n = 10) self-aspirating needle alone or in combination (n = 7). To determine the amount of compression achieved with the transducer, the skin-to-lesion distance on reference computed tomographic (CT) scans was compared with that on sonograms. A biopsy was considered successful if a specific benign or malignant diagnosis was rendered by the pathologist. RESULTS: Of 35 sonographically guided biopsies, 30 (86%) were successful. Diagnoses included 26 (74%) cases of carcinoma, three (9%) cases of benign reactive lymphocytosis confirmed at open biopsy, and one (3%) case of a lymph node with a positive acid-fast bacilli stain. The average lymph node diameter was 2.1 cm (range, 0.9-4.3 cm). With sonography, a mean of 2.5 needle passes (range, 1-5) were made per biopsy. Transducer compression reduced the skin-to-lesion distance from an average of 8.8 cm (at CT) to 4.5 cm. CONCLUSION: Sonographic guidance seems to provide a reasonable alternative to CT in biopsy of small abdominal, pelvic and retroperitoneal lymph nodes.  相似文献   

3.
PURPOSE: The authors performed percutaneous biliary ductal shave biopsy through an existing transhepatic biliary drainage tract with use of the Simpson atherectomy catheter. The technical feasibility, sensitivity, and complications of this endoluminal biopsy method were studied when used for diagnosis of biliary ductal and pancreatic neoplasm. PATIENTS AND METHODS: Nineteen bile duct shave biopsies were performed in 18 patients with symptomatic biliary obstruction by using a 9-F Simpson directional atherectomy catheter. Seven of the 18 patients underwent nine negative percutaneous needle biopsies prior to undergoing percutaneous biliary drainage. Results of previous transcatheter brush biopsies performed through the transhepatic tract were negative in all patients. RESULTS: A histologic diagnosis was obtained in 15 of the 19 procedures (sensitivity, 0.79) and included cholangiocarcinoma (n = 7), pancreatic carcinoma (n = 5), metastatic carcinoma (n = 2), and primary sclerosing cholangitis (n = 1). Two complications occurred in the 19 procedures (10.5%), both transient but significant hemorrhage, one of which necessitated transfusion. CONCLUSIONS: Percutaneous biliary ductal shave biopsy with the Simpson atherectomy catheter can be performed successfully through the transhepatic approach and is a sensitive endoluminal biopsy technique, particularly in patients with tumors of the biliary tree that are not diagnosed by means of percutaneous needle biopsy or endoscopic methods. Disadvantages of this method include the high cost of the device and risk of hemorrhage. Atherectomy shave biopsy should be used cautiously and only after more conventional biopsy methods have been employed.  相似文献   

4.
Fetal/neonate kidneys obtained at the time of autopsy were utilized to determine a suitable needle biopsy gauge to obtain renal parenchyma for histologic evaluation. Twenty-one fresh kidney specimens from 11 fetuses/neonates between 16-40 weeks gestation were used to obtain needle biopsies using 20-, 18-, 16-, and 14-gauge biopsy catheters. The specimens were graded according to the presence of normal histologic features of renal parenchyma. Seventy-five renal biopsies were obtained. The biopsy histology was interpreted using a grading system based on the presence of normal features of the renal parenchyma. Sixty-three (84%) of the samples were graded histologically as adequate (cortex or medulla present). Samples with both cortex and medullary structures present (completely adequate) were obtained in 39/63 (62%) of these adequate biopsies. The 14- and 16-gauge biopsy catheters gave the best results, respectively yielding 79 and 69% completely adequate biopsies. This is in contrast to the 20- and 18-gauge catheters that respectively yielded 35 and 25% completely adequate biopsies. Our initial results indicate that adequate kidney biopsies can be obtained. However, the current technique is associated with core sample disruption when the smaller gauge catheters are used. This could account for the low rate of completely adequate samples with the smaller gauge catheters. A different sampling technique is needed to overcome sample disruption, to determine the smallest catheter gauge that will yield a suitable tissue sample for histologic evaluation.  相似文献   

5.
This study evaluates the efficacy of ultrasound guided percutaneous biopsy using an 18 gauge automated side-cutting needle in the diagnosis of small (< or = 3 cm) focal hepatic lesions. 137 consecutive percutaneous biopsies of 131 different small (< or = 3 cm) focal hepatic lesions were included. 11 biopsies were performed on lesions of < or = 1 cm in diameter, 56 were on lesions 1.1-2 cm in size and 70 on lesions 2.1-3 cm in size (average 2.3 +/- 0.7 cm; median 2.3 cm; range 0.7-3 cm). The biopsy specimen was sufficient for diagnosis in 135 cases (98.5%). The sensitivity for diagnosing malignancy was 96.4%; specificity was 100%, positive and negative predictive values were 100% and 94.6%, respectively; accuracy was 97.8%. There was no statistically significant difference in the diagnostic efficacy for lesions of different pathology and size. No significant post-biopsy complication occurred. It is concluded that the 18 gauge Temno needle is safe and effective in diagnosing small hepatic lesions.  相似文献   

6.
A technique for biopsy of small or inaccessible mediastinal, hilar, or pulmonary lesions with computed-tomographic (CT) guidance is described. A modified coaxial system was used in order to make multiple passes possible without multiple punctures. The size of the original puncture needle (23 gauge) provided the inherent safety associated with a fine needle. All repositioning was done using this needle and CT until the lesion was engaged. The hub of the needle was then cut, and a 19-gauge needle was inserted coaxially over the larger needle. After removal of the 23-gauge needle, multiple biopsy specimens were then obtained coaxially with a 22-gauge needle through the 19-gauge needle. One small pneumothorax and no bleeding occurred in 10 instances. Results suggest that the combined use of CT guidance and this modified coaxial system may offer an extra margin of safety for difficult cases.  相似文献   

7.
BACKGROUND: The introduction of automated biopsy devices and the localization of the kidney by ultrasound were aimed at optimizing efficacy and safety of the percutaneous renal biopsy procedure. We evaluated these technological advances in our renal biopsies performed in children. METHODS: We sequentially used the Silverman needle (1969-1974), the TruCut needle (1974-1990), and the automated Biopty device (1990-1996). Fluoroscopy was used to localize the kidney until 1985, ultrasound examination prior to biopsy from 1985 to 1992, and direct ultrasound guidance since 1992. A total of 962 native kidney biopsies and 119 allograft biopsies were performed. RESULTS: In the native kidney biopsies, the introduction of the Biopty device and ultrasound guidance were independently associated with fewer passes required to obtain adequate tissue and more glomeruli per specimen. The rate of biopsies yielding more than 9 glomeruli increased from 69 to 92% (p < 0.05). The number of glomeruli harvested per centimeter core length was inversely related to patient age (p < 0.01). More appropriate cortical tissue was retrieved in renal allograft biopsy specimens with the application of the new techniques. The occurrence of macroscopic hematuria (9. 6%) in the native kidney biopsies was not affected by the puncture or localization technique applied, but subcapsular hematomas were documented more often with the Biopty device (42%) than with the TruCut needle (16%), probably due to improved ultrasound equipment. In the whole series 2 patients died, and 3 others required renal surgery and 4 blood transfusions. CONCLUSIONS: The automated ultrasound-guided procedure is a feasible and reliable technique for percutaneous renal biopsy in children. It gives a greater yield of diagnostic tissue without increasing the rate of clinical complications.  相似文献   

8.
To determine the safety and advantages of laparoscopic liver biopsy in pediatric liver disorders, we reviewed the medical records of 80 children affected by liver disease of various etiologies who underwent this procedure from 1986 to 1996. The main indicators for laparoscopic biopsy were increased risk of bleeding (i.e., mild to moderate coagulation abnormalities in patients probably affected by cirrhosis) and/or previous poorly informative blind needle liver biopsy (65 cases), and the need for a large amount of liver tissue for biochemical assays (10 cases). After inspection of the liver surface, at least two core biopsies were performed using a Tru-cut needle. We encountered difficulties with the biopsy in only four cases, due to a hard consistency of the liver. Bleeding time from the liver orifice was greatly reduced by positioning a fibrin plug (50-120 s vs 5-10 s, on average). In 15 patients, a large excisional biopsy was also successfully performed. Our results confirm an important role for laparoscopy in the diagnosis of cirrhosis (30% of bioptic false negative diagnoses in this series) and show that in selected cases laparoscopy-guided needle or excisional biopsy is an easy, useful and safe alternative to percutaneous blind liver biopsy.  相似文献   

9.
Open testicular biopsy is a classic method of investigation in men with azoospermia. Recently, percutaneous needle biopsy of the testis has been used in attempts to obtain material for histopathological diagnosis in such cases and to retrieve spermatozoa for intracytoplasmic sperm injection (ICSI). To determine whether a 19 gauge (G) and a 21G butterfly needle could be used for percutaneous aspiration of testicular tissue to determine the presence of mature spermatids and assess spermatogenesis, 10 patients (16 testes) and 12 patients (17 testes) underwent 19G or 21G needle biopsy respectively, immediately followed by open testicular biopsy, with both procedures under local anaesthesia. Biopsy with each needle size was compared with open biopsy. With the 19G needle, in the 14 cases where material was obtained there was full agreement with open biopsy regarding the presence or absence of mature spermatozoa, whereas with the 21G needle only nine of the 13 biopsies yielding material were predictive in this respect. Each needle size correlated poorly with open biopsy regarding evaluation of spermatogenesis. We conclude that percutaneous biopsy with a 19G butterfly needle is a quick and reliable method for demonstrating spermatozoa for ICSI. But for a detailed histopathological diagnosis, however, the needle biopsies gave poor results, whereas the material from the open testicular biopsies was assessable.  相似文献   

10.
The ultrasound guided percutaneous fine needle biopsy (US-FNAB) of focal lesions in the liver is indispensable in many clinical situations. During the last 12 years, 657 US-FNAB were performed on patients with suspected neoplastic involvement of the liver with 22-gauge Chiba needles at our department. US-FNAB was performed mostly with the "free hand" technique. Sufficient material for cytologic analysis was obtained in 84% of the cases. The biopsies confirmed malignancy in 39.3%, including 9% primary hepatocellular carcinoma, 8% of the cases were suspect for malignancy, and in 36.7% were diagnosed benign lesion. 233 cases were confirmed histologically and with other follow up methods. The sensitivity rate was 91%, and specificity was 100%. There was no false positive diagnosis and no noteworthy complications were observed. US-FNAB is a highly reliable, safe, inexpensive and easy diagnostic procedure. On the basis of our experience, we recommend US-FNAB as a routine, first level procedure for the diagnosis of focal liver diseases.  相似文献   

11.
Renal allograft biopsy is very valuable in the assessment of graft dysfunction, but complications are frequent and graft loss has even been described. Between 1991 and 1993, a total of 133 graft biopsies were done. We used an automated biopsy gun with a fine-caliber core needle (diameter 1.2 mm) under ultrasound guidance. Histological diagnosis was possible in 95.5% of the biopsies. On average 5.5 glomerula per specimen were obtained. This method proved to be safe, surgical intervention becoming necessary in 2 cases (1.5%).  相似文献   

12.
BACKGROUND: Ultrasound-guided renal biopsy with an automated spring-loaded biopsy device has become the standard method for kidney biopsy. Information on the success rate and safety of the routine use of this procedure from large series is not available. Such information is of interest for cost benefit considerations and for medicolegal purposes. We performed an audit of this procedure. SUBJECTS AND METHODS: From January 1993 to June 1997, 1090 percutaneous renal biopsies were performed in the renal units of Heidelberg (n = 557) and Karlsruhe (n = 533) using a spring-loaded biopsy device (Biopty; Radiplast AB, Uppsala, Sweden). After intensive local disinfection, biopsies were performed under local anaesthesia and direct visualization by ultrasound (Sonolayer SSH-140 A, Toshiba Inc., Japan). A puncturing adaptor was used (model UAGV 009 A, Toshiba, Japan). Of the 1090 biopsies 114 (10.4%) were performed on renal allografts and 976 (89.6%) on orthotopic kidneys. Biopsies were performed only if patients were strictly normotensive (<140/90 mmHg) and had normal coagulation parameters (PT, PTT, factor VIII, thrombocyte count, and bleeding time). All patients had been advised not to take aspirin or non-steroidal antiinflammatory agents for at least 5 days prior biopsy. We analysed (1) yield of diagnostically useful material, and (2) frequency of postbiopsy complications (e.g. macrohaematuria, haematoma, infections, and AV fistula). RESULTS: Except for one case requiring interventional radiology because of persisting blood loss and three cases requiring blood transfusions, no serious complications were seen in the 1090 consecutive renal biopsies, e.g. death, loss of kidney, life-threatening haemorrhage, or persisting haemodynamically relevant AV fistulae. The frequency of minor haematoma with an extension >2 x 2 cm, but no significant decrease of haemoglobin, was 2.2% (25/1090). Self-limited mild macrohaematuria occurred in 0.8% (9/1090). The incidence of small, haemodynamically irrelevant AV fistulae detected by Doppler ultrasound was 9% (48/533). Sufficient tissue for reliable histopathological diagnosis was obtained in almost all cases (1077/1090 = 98.8%). The median number of glomeruli per biopsy sample was 9 (range 1-37). CONCLUSION: If contraindications, especially high blood pressure and abnormal haemostasis, are respected, ultrasound-guided percutaneous renal biopsy with an automated biopsy device is safe. Skilled operators obtain satisfactory amounts of kidney tissue in almost all cases.  相似文献   

13.
Ultrasound-guided percutaneous core biopsy technique was studied in 15 consecutive patients with chronic Achilles tendon disorder defined as persisting local pain during daily activities, localized pain and swelling on palpation 2-5 cm proximal to the calcaneal insertion. Ultrasound verified widening of the tendon and low echogenous areas at the site of pain. Percutaneous biopsies were taken from both the low echogenous areas and the normoechogenic tendon tissue. Of 104 core biopsies 99 were representative. Open biopsies were taken from the macroscopically injured and normal tendon for comparison. Core and open biopsies of the low echogenous and macroscopically injured tendon showed similar histopathology. In 10 patients the core biopsy was performed under local anesthesia with limited subjective symptoms. Five of these patients were operated 18-41 days later. No adverse effect was found referring to the biopsy taken a few weeks prior to surgery. No complications occurred. We conclude that the percutaneous core biopsy, guided by ultrasound and performed under local anesthesia, can be used under clinical and experimental in vivo studies for improving knowledge on pathoanatomy and healing processes of the Achilles tendon.  相似文献   

14.
BACKGROUND: Traditionally, radiologically detected lesions of the breast have been evaluated by open surgical biopsy with wire localization. Recently, core needle biopsy has been introduced as an alternative to open surgical biopsy. The authors evaluated their own results with long term follow-up after core needle biopsy and reviewed the experience of other physicians with this new technique. METHODS: Four hundred thirty-one core needle biopsies performed at UCLA were analyzed. The outcome of these cases was determined by either surgery or long term follow-up. Statistical analysis was performed to determine the accuracy of the method. RESULTS: Definitive outcome was obtained in 96% of the core needle biopsy cases, with a median follow-up time of 18 months (range, 6-38 months). The authors achieved a sensitivity of 99% and a specificity of 100%. The false-negative rate was 1.7%. There were no complications in this series. CONCLUSIONS: Core needle biopsy is a highly accurate and safe method for the diagnosis of radiologically detected lesions of the breast.  相似文献   

15.
INTRODUCTION: During the last 20 years routine application of various methods of multiple "small biopsies" of the lungs such as forceps, transbronchial, trucut percutaneous and so on, has significantly increased the efficacy of diagnostics of bronchopulmonary and pleural diseases. Tissue samples, not bigger than 3-4 mm, in which diagnostic pathological changes are expected on the basis of previous clinical, radiological and bronchoscopic examinations, can be the basis for making a definite therapeutical decision only if a skillful surgeon has performed the biopsy by correct instruments and from the right place and sent it for histological analysis with other important clinical information. This study is a comment on quality, significance and possibilities of improving clinical-pathological cooperation in this field of clinical pathology. MATERIAL AND METHODS: By correlation of clinical and histological diagnoses we analyzed the diagnostic efficiency of microscopic examinations of "small biopsies" of the respiratory tract in 319 patients (175 bronchial forceps biopsies, 31 transbronchial biopsies, 22 percutaneous needle pleural biopsies and 91 combined forceps and transbronchial biopsies) in whom biopsies were performed during 1996 in the Specialized Hospital for Lung Diseases Brezovik. RESULTS: Overall concordance between the clinical and histopathological diagnosis was 82.2%. In 99 cases (73.3%) out of 135 clinically "obvious" neoplasms, the histopathological examination confirmed existence of malignant tumor: squamous cell carcinoma in 80%, small cell carcinoma in 9.6% and adenocarcinoma in 5.6% of patients. In other patients it was not possible to perform a more precise classification. Endoscopic specimens of 29 patients (9.1%) were not representative. CONCLUSION: The level of diagnostic efficiency (73.3%) of definitive histopathological verification of bronchopulmonary lesions, which have been clinically diagnosed as malignancies, is rather high, but the increase of diagnostic efficiency requires application of more sophisticated histological diagnostic methods (immunohistochemical) and more frequent utilization of bioptic procedures which are more convenient for detection of peripheral pulmonary lesions (transbronchial and percutaneous fine needle aspiration biopsies of the lungs).  相似文献   

16.
OBJECTIVE: This investigation was performed to test the hypotheses that interactive guidance of MR image acquisition during needle-directed procedures using a clinical 0.2-T C-arm open MR imaging system integrated with a frameless optically linked stereotaxy system is feasible, and that procedure times can be sufficiently short to be well tolerated by the patient. SUBJECTS AND METHODS: One hundred six MR-guided procedures were performed in 86 patients (ranging in age from 5 months to 88 years) using a clinical C-arm imaging system supplemented with an in-room RF-shielded liquid crystal display monitor, a frameless stereotaxy system, rapid gradient-echo sequences for needle guidance, and MR-compatible monitoring and surgical lighting equipment. We performed 50 biopsies and aspirations of the head and neck in 37 patients, 23 biopsies of musculoskeletal lesions in 22 patients, 16 biopsies of abdominal sites in 10 patients, six biopsies of the thoracolumbar spine or sacrum in six patients, and 11 shoulder joint injections for MR arthrography in 11 patients, in addition to 38 MR arthrographic injections on the same imaging system described in a previous report. Tissue sampling included fine-needle aspiration (n = 90) and cutting needle core biopsy (n = 41). Thirty-five patients underwent both procedures. Procedures were evaluated for success of needle placement, procedure time, and complications. RESULTS: Needle placement was successful in all cases, and no complications occurred. Tissue was sufficient for pathologic diagnosis for all but eight patients. Passes per patient averaged 2.1. For fine-needle aspiration, instrument time averaged 7 min 42 sec per pass, cutting needle core biopsy averaged 6 min 24 sec, and shoulder injection averaged 8 min. CONCLUSION: MR imaging guidance for needle procedures on a clinical 0.2-T C-arm system with supplemental interventional accessories is feasible, with relatively rapid needle placement.  相似文献   

17.
Bone biopsy is necessary for the diagnosis of ambiguous skeletal lesions. Although several merits of computed tomography (CT)-guided percutaneous needle biopsy have been documented, few radiologists have performed this procedure in Japan. We performed this procedure with a newly introduced bone biopsy needle (OSTYCUT, angiomed, Karlsruhe, Germany) under CT guidance and evaluated the results. CT-guided bone biopsy (pelvic[n = 11]vertebral[n = 10], femoral[n = 1], sternal[n = 1]) was performed in 19 consecutive patients. Seventeen patients were suspected metastatic disease, and the others were suspected primary bone tumor. All biopsies but one were diagnostic. Malignancy was proved in 11 lesions. Three patients with prostatic carcinoma were proved to show no malignancy of bone lesions after a series of hormonal and chemotherapies. In one patient with both malignant mesothelioma and cervical carcinoma, the biopsy specimen from thoracic vertebra proved metastasis from mesothelioma. CT-guided bone biopsy is useful to evaluate the presence of malignancy and the effect of therapy for it, and to determine the primary site.  相似文献   

18.
INTRODUCTION: Any breast lesion/abnormality detected at mammography must be characterized as (non)-neoplastic before surgery. Fine needle aspiration cytology (FNAC) permits a precise diagnosis in over 70% of cases but exhibits many inadequate, false negatives or questionable findings. This makes surgical biopsy mandatory in many cases. An alternative is offered by fine needle biopsy (FNB: 16-18 G needles) or by large core biopsy (LCB: 14 G needles), which procedures can reduce the number of questionable diagnoses with no major discomfort or side-effects for the patient. MATERIAL AND METHODS: January, 1996, to October, 1997, we performed 422 microhistologic biopsies on breast lesions at the Unità Integrata di Senologia, Azienda Ospedaliera Careggi, Florence, Italy. 383 of these lesions were nonpalpable. FNB was performed in 221 cases and LCB in 201. Most biopsies (65%) were carried out under US guidance and some others (25%) under stereotactic guidance. RESULTS: Microhistologic biopsy allowed accurate lesion characterization in most cases, even though LCB obviously performed much better. Samples were inadequate in 5.88% of cases with FNB and only in 2.98% of cases with LCB. The false negative rate was 1.92% for FNB and 0.99% for LCB. Surgical biopsy was needed for an unquestionable diagnosis only in 9.5% of FNB and 3.9% of LCB cases. CONCLUSIONS: Our results confirm the literature data on how LCB can be considered a valid alternative to surgical biopsy (and, to some extent, to FNAC); in particular, its advantages are: moderate invasiveness, little patient discomfort and high diagnostic accuracy. Moreover, the procedure is short (5-10 minutes) and costs much less than surgical biopsies (1/2 to 1/4).  相似文献   

19.
OBJECTIVE: This retrospective study was undertaken to show the efficacy and safety of one-step needle aspiration and lavage for the treatment of nonenteric, nonpancreatic abdominal and pelvic abscesses. MATERIALS AND METHODS: Eighty-two nonconsecutive patients (age range, 4-81 years old) with 97 abdominal and pelvic abscesses were treated over 16 years with a one-step percutaneous needle aspiration and lavage technique. Abscesses were drained with sonographic or CT guidance in a single session. An 18-gauge needle was used for aspiration and repeated saline lavage; no drainage catheter was left in place. For collections that appeared multiloculated, needle repositioning and repeated aspiration and lavage were performed during the single session. All patients received i.v. antibiotics. RESULTS: Eighty-seven (90%) of 97 abscesses in 72 of 82 patients were successfully treated, including 17 (85%) of 20 abscesses that were multiloculated. The only two complications were transient sepsis in one patient and hemorrhage in one patient that resolved with transfusion and conservative treatment. Needle aspiration and lavage failures were associated with diffuse peritonitis, occult malignancy, unsuspected enteric communication, and a dropped surgical clip. CONCLUSION: Percutaneous needle aspiration and lavage can be a safe, effective alternative to the more conventional treatment of prolonged catheter drainage. In selected patients, including certain patients with multiloculated abscesses, one-step needle aspiration and lavage should be considered as the initial method of treatment.  相似文献   

20.
OBJECTIVES: To evaluate the clinical utility of transrectal ultrasound-guided systematic sextant needle biopsies in the prediction of extracapsular extension (ECE) at radical prostatectomy. METHODS: A retrospective analysis of 104 men who underwent systematic biopsy and radical prostatectomy at our institution was performed. All patients underwent preoperative staging by transrectal ultrasound and transrectal ultrasound-guided systematic sextant biopsy. The presence of pathologic ECE was correlated to the number of positive core biopsies on each side of the prostate by chi-square analysis. Sensitivity, specificity, positive and negative predictive values, and likelihood ratios (LRs) were calculated for both positive (two or three biopsies positive per side) and negative (no or one positive biopsy per side) test results. RESULTS: Forty-two (20.2%) of 208 sides demonstrated evidence of ECE at radical prostatectomy. Chi-square analysis demonstrated a significant correlation between the number of positive biopsies and the presence of ECE at radical prostatectomy (P = 0.001). Overall, the finding of multiple positive core biopsies (two or three per side) had predictive value with regard to the presence of ECE (sensitivity 62%, specificity 77%, positive predictive value 40%, negative predictive value 89%). The corresponding LRs were 2.5 for a positive and 0.5 for a negative test result. CONCLUSIONS: The probability of ECE at radical prostatectomy can be more accurately assessed preoperatively by the combined use of transrectal ultrasound and systematic sextant needle biopsies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号