首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The aim of this study was to evaluate the effect of bulk-fill flowable composites on cuspal deflection and fracture resistance of endodontically treated teeth. Forty-two maxillary premolars were subjected to endodontic treatment followed by the preparation of mesioocclusodistal cavities. Teeth were divided into six groups according to restorative materials as follows: Group 1: Clearfil Majesty Flow and Clearfil Majesty Posterior; Group 2: Venus Bulk Fill and Clearfil Majesty Posterior; Group 3: Clearfil Majesty Posterior; Group 4: Vertise Flow and Clearfil Majesty Posterior; Group 5: SDR and Clearfil Majesty Posterior; and Group 6: x-tra base and Clearfil Majesty Posterior. A single-step self-etch adhesive (OptiBond All-in-One) was applied to all groups, except Group 4. The cavities were restored with a centripetal incremental insertion technique and flowable composites using a 2-mm-thick base material, except for Group 3. The distance between cusp tips was measured before and after the cavity preparations, after the restorations, and after thermal cyclus with a digital micrometer. After measuring, each tooth was subjected to compressive loading with a stainless steel ball (4 mm diameter) perpendicular to the occlusal surface with a crosshead speed of 1 mm/min, and mean loads necessary to fracture were recorded in Newtons. The data were statistically analyzed by Kruskal–Wallis test. No statistically significant differences were found between groups in fracture strength or cuspal deflections (p > 0.05). Bulk-fill flowable composite bases did not change the cuspal deflection or fracture resistance of endodontically treated teeth, compared with that of a conventional flowable base and conventional resin composite.  相似文献   

2.
The effect of adhesive systems on microleakage in endodontically treated teeth restored with glass fiber posts was studied. Forty carious and crack-free premolars were prepared using a stepback technique and obturated with gutta-percha. The endodontically treated roots were randomly divided into four groups (n?=?10). Glass fiber posts cemented following adhesive luting agents; group 1: All Bond 3/Duo Link (ALB/DL), group 2: One-Step Plus/Duo-Link (OSP/DL), group 3: Panavia F 2.0/Panavia ED Primer II (PAN/ED), and group 4: Rely X Unicem (RU). All specimens were thermal cycled and stored in basic fuchsin solution for one week. The roots were sectioned horizontally into three sections: apical, middle, and coronal. The occlusal direction of each section was digitally photographed under a stereomicroscope. Dye penetration area was calculated as the basic fuchsin infiltrated surface divided by total dentin. The data were statistically analyzed using the Mann–Whitney U and Wilcoxon Signed Ranks Tests (α?=?0.05). The mean area measurements were ranged between 0 and 3.7357. According to the Mann–Whitney U test, there was no significant difference among the groups and sections (p?>?0.05). Intragroup comparisons showed a significant difference between coronal-apical and middle-coronal sections in Panavia group (p?=?0.043) by Wilcoxon Signed Test. It was found that there was no significant difference among four groups and the apical, coronal, and middle sections. The only difference was found for the group of PAN/ED between coronal-apical and coronal-middle sections.  相似文献   

3.
Objectives: The aim of this in vitro study was to evaluate the effect of different desensitizers’ application on the microleakage of previously restored Class V composite resin restorations.

Materials and methods: Class V cavities were prepared on the buccal surfaces of 40 extracted human third molars. Forty box-shaped cavities were divided into four groups, based on the desensitizers used (n = 10). All teeth were restored with the same bonding agent and composite material. No desensitizer was applied in the control group. In the experimental groups, BisBlock, Gluma and Universal bonding agents were the desensitizers. The desensitizers were applied after completion of composite restorations according to manufacturers’ instructions. All specimens were then thermocycled at 5–55 °C, with a 10-s dwell time for 500 cycles. The samples were then immersed in 0.5% methylene blue dye for 24 h, sectioned into two equal halves, evaluated for microleakage using a stereomicroscope at 30× magnification and scored on a scale of 0–3. The data were analysed using the Kruskal–Wallis test at the significance level p < 0.05.

Results: There were no significant differences in microleakage after desensitizer application (p > 0.05). However, based on the obtained numerical values in our study, while the BisBlock and bonding groups showed lower microleakage at the occlusal margin, BisBlock, Gluma and bonding group showed lower microleakage at the gingival margin compared to the control group.

Conclusions: The application of desensitizers as a post-treatment option could be considered an advisable procedure to minimize microleakage.  相似文献   


4.
To evaluate the effect of different surface treatment protocols on the microtensile bond strength (μTBS) of bulk-fill resin composite repairs. Thirty-five bulk-fill resin composite samples (Filtek Bulk Fill) were prepared (5 × 5 × 5 mm) and aged by thermocycling (X5000). Samples were randomly divided into five groups (n = 7): a control (no treatment) and four surface treatment groups (Single Bond Universal [SBU]; phosphoric acid (37%) + SBU; Er,Cr:YSGG laser + SBU; aluminum oxide sandblasting + SBU). Filtek Ultimate Universal composite was used as a repair material. After storage for 24 h in distilled water (37 °C), sticks were obtained and subjected to a μTBS test. The data (MPa) were analyzed by one-way ANOVA with a post hoc test (α = 0.05). Failure mode was evaluated using a light microscope (10×). There were significant differences between the groups (p < 0.05). The lowest bond strength values were obtained in the control group (p < 0.05). No significant difference was observed between Group II (universal adhesive) and Group III (acid etch + universal adhesive) (p > 0.05). The bond strength of Group II was significantly lower than that of the other surface treatment groups (p < 0.05). While Group III showed significantly lower values than those of the laser treatment group (Group IV), similar values were obtained with Al2O3 sandblasting group (Group V). The highest repair bond strength was obtained in Group IV (p < 0.05) which was not significantly different from the Al2O3 sandblasting group (p > 0.05). The predominant failure mode was adhesive. Treatment of aged bulk-fill resin composite surfaces with laser and Al2O3 sandblasting provided higher repair bond strength values.  相似文献   

5.
This study evaluated the long-term microleakage of access cavities conditioned with phosphoric acid and deproteinizing agents for root-canal-treated teeth using fluid filtration and microscopical analysis. Occlusal surfaces of extracted human mandibular premolars (N = 90) were removed leaving a 4 mm coronal length from the cemento-enamel junction. After root canal treatment, the specimens were randomly divided into four experimental groups (n = 21) and the remaining teeth were used for positive control group (n = 6): SB: 35% H3PO4 + Adper Single Bond 2; SSB: 35% H3PO4 + 5.25% NaOCl + 10% Sodium ascorbate (C6H7NaO6) + Adper Single Bond 2; XP: 35% H3PO4+XP Bond; SXP: 35% H3PO4+5.25% NaOCl + 10% Sodium ascorbate + XP Bond. All cavities were restored with a resin composite (Filtek Z250). After removing the root filling from the apical side, teeth were subjected to fluid filtration test for 1 week, 6 and 12 months followed by ×2500 thermocycling after 1st week and 6th months each. Data were analyzed using one-way ANOVA and Dunnet T3 tests (α = 0.05). SEM analyses were carried out after each microleakage evaluation in two random teeth from all groups. Microleakage values in groups SB and XP presented no significant difference in any of the evaluated period (p > 0.05). Microleakage results of SXP (0.01665) group showed significant difference compared to XP (0.03377) and SB (0.03049) groups after 12 months. SSB group (0.00901) showed significantly less microleakage among all other groups (0.01665–0.03377) (p < 0.05). Prior to endodontic treatment, in access cavities, acid etching with 35% H3PO4 followed by the application of NaOCl and sodium ascorbate completely destroyed the collagen layer, reducing the microleakage and resin–dentin interface degradation up to 12 months.  相似文献   

6.
This study evaluated the load-bearing capacity of premolars restored with three types of resin composite materials in mesio-occluso-distal (MOD) cavities. Extracted human premolars (N = 30, n = 10 per group) were randomly divided into three groups; MOD cavities were prepared and restored with one of the following resin materials: Group BFC: Bulk-fill composite (SonicFill, Kerr Corporation), Group NC: Nanohybrid resin composite (Filtek Z550, 3M ESPE), Group SC: Silorane-based composite (Filtek Silorane, 3M ESPE). For NC Clearfil SE Bond (Kuraray, Japan) and for SC, Silorane adhesive resin (Filtek Silorane System Adhesive, 3M ESPE) were used. The cavities in NC and SC groups were restored incrementally, while those in BFC groups were restored in bulk. After water storage (24 h, 37 °C), each tooth was subjected to compressive loading with a stainless steel ball (diameter: 4 mm) perpendicular to the occlusal surface (1 mm/min). Failure types were categorized according to being repairable or irrepairable. Data were statistically analysed using Kruskal-Wallis test (α = 0.05). Two-parameter Weibull distribution values including the Weibull modulus, scale (m) and shape (0) values were calculated. Fracture resistance of premolars restored with BFC (829.84), NC (701.35) and SC (807.73) did not show significant difference (p = 0.72). Weibull distribution presented lower shape (0) for SC (m = 2.77) and NC (m = 3.09) compared to BFC (m = 5.01). The incidence of repairable failures was more common in BFC (80%) compared to NC (60%) and SC (50%). Adhesive failures were more often observed in NC (80%) and SC (70%) groups.  相似文献   

7.
Aim: The aim was to compare the microleakage of resin composite bonded with different adhesive systems in class-II cavities at enamel or dentine margins. Material and methods: 60 extracted human molar teeth received slot cavity preparations on mesial and distal surfaces (mesial cervical margin was prepared in enamel and distal in dentine). They were randomly divided into five groups (n?=?12) according to the adhesive system: Group-A: Silorane Bond (S), Group-B: Adper Single Bond 2 (SB), Group-C: Clearfil SE Bond (CSE), Group-D: Single Bond Universal (USel) (selective etch-and-rinse), Group-E: Single Bond Universal (USE) (all-in-one). The preparations were restored using the same resin composite (Filtek Ultimate) except Group A which was restored by Silorane composite. The teeth were thermocycled, immersed in dye, sectioned, and dye penetration was evaluated quantitatively using image analysis. The data were analyzed using the two-way analysis of variance and Bonferroni test. Results: In all groups, there was no statistically significant difference between enamel margins at occlusal and gingival sites (p?>?0.05). The statistical difference between Group-A (S) and Group-B (SB) was significant at all margins. Group-B (SB) presented the greatest microleakage amounts at all margins and the highest scores were obtained in the dentine. Likewise, SB demonstrated statistically significant differences between dentine and enamel margins (occlusal and gingival)(p?<?0.05). Conclusion: All adhesive systems showed similar microleakage values between enamel margins in occlusal and gingival regions. However, when the gingival margin is located in the dentine, etch&rinse adhesive systems may not be a choice in terms of microleakage prevention.  相似文献   

8.
This study compared the effect of different adhesive systems and composite resins on the shear bond strength (SBS) of repaired high-viscosity bulk-fill composites(Tetric EvoCeram Bulk Fill) and investigated failure modes. One hundred twenty cylindrical bulk-fill composite blocks (diameter 5?mm) were fabricated and thermocycled for 5000 cycles (5–55?°C). Specimens were roughened by diamond bur and divided into 8 groups (n?=?15). Bulk-fill blocks were repaired with the same material or nanohybrid composite resin(Tetric EvoCeram Nanohybrid) (diameter 3?mm) using different adhesive systems:Tetric N-Bond Universal (TSE);37% phosphoric acid etching?+?Tetric N-Bond Universal (TER); Clearfil SE Bond (CSE); 37% phosphoric acid etching?+?AdperTMSingle Bond 2(SB). After repair procedures, all specimens were thermocycled again. The shear bond strengths were measured for all specimens using a universal test machine (crosshead speed of 1?mm/min). Cohesive strengths of bulk-fill composites were measured and described as control group. Debonded surfaces were observed with a stereomicroscope under 10x magnification to determine mode of failure. The SBS data of all groups was statistically analyzed by two-way ANOVA and Bonferroni correction test (p?<?0.05). The specimens repaired with bulk-fill composites showed significantly higher SBS values (25.86?±?5.74, 27.05?±?4.93, 24.49?±?6.95MPa) than those with nanohybrid composites (20.41?±?3.70, 22.08?±?6.37, 18.74?±?6.40?MPa) for TER,CSE,SB, respectively (p?<?0.05). There were no significant differences in SBS according to the type of adhesive systems for both repair materials (p?>?0.05). The predominant mode of failure was a mixed type in the restorative material except for the ones repaired with nanohybrid composites using AdperTMSingle Bond 2. High-viscosity bulk-fill composites could be successfully repaired with the same materials. SBS of repaired bulk-fill composites reached cohesive strength for all tested groups.  相似文献   

9.
This study evaluated the effect of tooth preparation method (diamond bur vs. Er:YAG laser) on the microleakage levels of glass ionomers and resin composite. Human permanent premolars (N = 80) were randomly divided into two groups (n = 40). Cavities on half of the teeth were prepared using diamond bur for enamel and carbide bur for dentin and the other half using Er:YAG laser. The teeth were randomly divided into four groups according to the restoration materials, namely (a) ChemFil Rock (CFR), (b) IonoluxAC (IAC), (c) EQUIA system (EQA) and one resin composite (d) AeliteLS (ALS) (n = 10 per group). Microleakage (μm) was assessed at the occlusal and gingival margins after dye penetration (0.5% basic fuchsine for 24 h). On the occlusal aspect, while the cavity preparation types significantly affected the microleakage for CFR (p = 0.015), IAC (p = 0.001) glass ionomer restorations, it did not show significant effect for glass ionomer EQA (p = 0.09) and resin composite ALS (p = 0.2). Er:YAG laser presented less microleakage compared to bur preparation in all groups except for EQA. On the gingival aspect, microleakage decreased significantly for CFR (p = 0.02), IAC (p = 0.001), except for EQA where significant increase was observed (p = 0.001) with the use of Er:YAG laser. Microleakage decrease was not significant at the gingival region between diamond bur and Er:YAG laser for ALS (p = 0.663). At the occlusal and gingival sites in all groups within each preparation method, microleakage level was not significant.  相似文献   

10.
The effect of various post materials luted with different resin luting cements on microleakage in root canals was studied in the present study. Sixty carious and crack-free premolars were prepared using a step-back technique and obturated with gutta-percha. The roots were randomly divided into six groups (n = 10). Two different post types, glass fiber reinforced posts and zirconium posts (ZP), were cemented three different resin adhesive cements (Panavia F 2.0, Smartcem 2, and Variolink II) in the root canals. All specimens were thermal cycled and stored in the methylene blue solution for one week. The roots were sectioned horizontally into three sections: apical, middle, and coronal. The occlusal direction of each section was digitally photographed under a stereomicroscope. Dye penetration area was calculated as the methylene blue-infiltrated surface divided by total dentin area. After the two-way Anova test results, Tukey HSD and Bonferroni tests were used for multiple comparisons. According to the test results, ZP luted with Panavia F showed the best microleakage results and glass fiber posts luted with smartcem 2 showed the most unsuccessful microleakage results (p = 0.146).  相似文献   

11.
Methods for restoring endodontically treated teeth fall short of restoring the physiologic mechanical properties. Fracture of endodontically treated teeth is a common type of clinical failure. New treatment modalities or perfected versions of existing treatment concepts need to be tested to find a biomimetic solution. A novel method of restoring endodontically treated teeth is presented and compared in vitro with currently accepted restorative methods. Seventy-two extracted and endodontically treated maxillary premolar teeth were divided into six groups (n = 12) depending on restorative technique (Groups 1–6). Group 1: fiber-reinforced composite post (FRC), Group 2: direct layered short FRC post and core, Group 3: short fiber-reinforced obliquely layered composite restoration, Group 4: microhybrid composite restoration, Group 5: fiber-reinforced box, Group 6: control. Specimens were submitted to static fracture resistance test. Fracture thresholds and fracture patterns were evaluated. Group 6 exhibited the highest fracture resistance. Group 2 yielded the highest fracture resistance among the restored groups. The fracture resistance of Group 2 did not differ significantly from Group 6. Groups 1, 3, 4, 5 proved to be significantly different from the control group. There was no statistically significant difference among restored groups. Fracture patterns of tested groups were dominantly non repairable opposed to control groups mostly repairable fractures. Application of direct-layered short FRC post and core in endodontically treated premolars performed statistically similarly in the studied conditions as natural teeth. Therefore, it seems a promising alternative to current endo-restorative solutions. However, further testing is required.  相似文献   

12.
《Ceramics International》2019,45(11):13988-13998
Introducing carbon nanotubes (CNTs) by electrophoretic deposition (EPD) is a promising method to improve the strength and toughness of carbon/carbon (C/C) composites. Herein, a new reinforcing mechanism called “compressive residual thermal stress (RTS) induced crack deflection” has been reported. Concretely, CNTs, with different loading content, were introduced by EPD method. Results showed that the CNT content had little influence on CNT-induced matrix refinement. However, the strength of the CNT-doped C/C composites increased with the rising content of CNTs and cracks could only deflect when the CNT interface reached a certain thickness. A theory based on compressive RTS induced crack deflection was built to interpret this discrepancy. Tensile stress existed at the interface in pure C/C composites, while compressive stress occurred and increased with the rising thickness of the CNT interface, which were verified by finite element analysis and Raman test. Calculation revealed that compressive stress exceeded 30 MPa at the crack tip could make the crack deflection happen more easily since it released more strain energy than penetration.  相似文献   

13.
This study assessed adhesion of bulk-fill resin-composites as core and post materials only versus the use of fiber resin composite (FRC) posts. Human teeth (N?=?84) were cut at the CEJ and endodontically treated and randomly divided into seven groups: TP: Titanium post (Flat Head T); SFRC: S2-glass FRC (Pinpost); EFRC1: E-glass FRC (GC Everstick) directly bonded; GFRC: E-glass FRC (Glassix Nordin); EFRC2: E-glass FRC (Everstick); BF1: Bulk-fill resin (Surefill SDR); BF2: Bulk-fill resin (SonicFill). Groups TP, SFRC, EFRC and GFRC were cemented (Panavia 21), while other groups were bonded directly to the intraradicular dentin. The core parts were constructed using a resin composite (G-aenial) except for Groups BF1 and BF2. The core-cervical dentin interface was loaded under shear forces. Push-out tests were performed in a Universal Testing Machine (1?mm/min). Data (MPa) were analyzed using two-way ANOVA and Tukey`s tests (α?=?0.05). Not the root level (p?>?0.05) but the type of core and post material significantly affected shear and push-out bond results (p?<?0.001). BF1 (9.2?±?2.1) and BF2 (9.3?±?3.1) showed significantly lower bond strength to the cervical dentin (p?<?0.05) compared to other groups (11.6?±?2.5–19?±?6.8). FRC post types did not show significant difference being higher than those of TP, BF1 and BF2 (0.57?±?0.37–2.34?±?1.98) (p?>?0.05). Partial cohesive core fracture was more common while BF1 and BF2 showed exclusively adhesive failures. Cohesive failure in the cement was frequent in Group TP (53%) compared to other groups (3–24%). BF1 and BF2 presented exclusively complete adhesive failure of the bulk-fill material.  相似文献   

14.
ABSTRACT

Ball milled jute fiber (JF) was added to Polyvinyl Alcohol (PVA)/20 wt.% multi-layer graphene (MLG) composites in various proportions (0, 5, 10, 15 and 20 wt.%) to prepare sustainable and biodegradable conducting polymer composites. Also, PVA/17.5wt.%MLG/2.5wt.%MWCNT/20wt.% JF composite was prepared for comparison purpose. A dynamic mechanical analysis of the composites was conducted to analyze their viscoelastic nature. The electrical conductivity of the composites was measured to study their suitability for various applications. Jute reinforcement increased the electrical conductivity of PVA/MLG nanocomposites. The PVA/20wt.%JF/17.5wt.%MLG/2.5wt.%MWCNT hybrid composite had the highest electrical conductivity of 3.64 × 10?4 S/cm among all the composites prepared. Multilayered structures of the hybrid composite films were made by hot-pressing, and their effectiveness in electromagnetic interference shielding was tested. The shielding effectiveness of the composites decreased with jute addition. The wear resistance of PVA/MLG/JF composites increased with an increase in the jute content up to an optimum value of 10 wt.%, and then it started deteriorating.  相似文献   

15.
To investigate shear bond strength (SBS) to dentin of a conventional and three bulk-fill composites applied in different increment thickness and cured by mono- and multi-wave LED LCUs. Two hundred and fifty-two extracted sound human molars were prepared for SBS test. The teeth were divided into four groups according to the resin composites used. Conventional composite: Tetric N-Ceram (control); high-viscosity bulk-fills: Tetric N-Ceram Bulk Fill, X-tra Fil, and SonicFill. Each group was subdivided (n?=?7) according to increment thickness (2, 4, and 6?mm) and cured by standard mode of a mono-wave LED or two different modes (standard and xtra power) of a multi-wave LED. The failure mode was stereomicroscopically determined at 40× magnification. Data were analyzed using Three-way ANOVA and further comparisons were assessed by Bonferroni’s multiple comparison test. There were no significant differences within X-tra fil and Tetric N-Ceram Bulk Fill groups for any of the variables (p?>?0.05). A significant decrease in SBS values with increase of layer thickness was observed for SonicFill and control groups. Also, curing mode had a significant effect on both composites at 6?mm thickness and standard mode of multi-wave LED caused the highest SBS value (p???0.05). Adhesive failure was the most common fracture pattern especially at 6?mm thickness applications. Based on the results of this study, the bulk-fill composites can be safely applied in one-step with 4?mm increments, although the examined composites performed better at 2?mm thickness. The performance of the composites at 6?mm increment may show differences related to the curing lights and modes.  相似文献   

16.
An exact analytical solution was derived for the concentration of solute or the temperature of the fluid in a constant molar flow semi-batch well-stirred vessel in contact with permeable core-shell composites. The linear equilibria at both the fluid-particle interface and the core-shell interface are assumed and the extraparticle film resistance is included. Several particular solutions can be readily degenerated from the solution derived in this work. By taking the contact affinity at the core-shell interface to zero, the solution in case of impermeable core-shell composites can be degenerated. By taking both the contact affinity at the core-shell interface and the ratio of mass or thermal effective diffusivities in the core and the shell to unity or by taking the size of the core to zero, the solution in case of homogeneous particles can be degenerated. The solution for the batch vessel is also degenerated by the differentiation of the solution for the constant molar flow semi-batch vessel with respect to time.  相似文献   

17.
聚合物/无机纳米粒子复合材料的研究进展   总被引:3,自引:0,他引:3  
综述了无机纳米氧化物(如SiO2、TiO2、Al2O3)、纳米硅化物(如SiC、Si3N4)和纳米CaCO3作为填充材料对聚合物材料物理、化学、热学、光学、力学及摩擦学性能的改善作用,在聚合物中加入纳米粒子是制备高性能复合材料的重要手段之一。  相似文献   

18.
To understand the microscale toughening mechanism, the crack propagation, and stress–strain response of unidirectional SiCf/SiC composites with h-BN interphase under transverse and longitudinal tension are investigated by a promising micromechanical phase field (PF) method along with representative volume element. Of much interest, the calculation results are well consistent with the available experimental results. With a strong dependence on the interphase strength, the toughening mechanisms during crack propagation are well presented, for example, fiber pull-out, crack deflection, and interphase debonding. Furthermore, the longitudinal tensile strength of SiCf/SiC composites increases with decreasing the interphase strength, where only a weak enough interphase can result in a significant crack deflection by its cracking. In particular, the ratio of the interphase strength along fibers to the matrix strength should be less than 1.254 to ensure crack deflection in the interphase and fiber pull-out. Moreover, the transverse tensile strength of SiCf/SiC composites reaches a maximum with increasing the interphase thickness into the range of 0.25–0.5 µm.  相似文献   

19.
以35t/h抛煤机炉节能环保改造项目为依托,采用实验和数值模拟的方法研究了采用排气管偏置方法对传统分离器的性能影响。实验结果表明,排气管在90°~270°方向偏置0.1~0.14,分离效率上升大约3%,阻力基本不变;排气管在180°~270°方向偏置0.25~0.33,分离效率降低大约5%,阻力降低约38%。数值模拟的结果从压力分布的角度深入解释了实验的结论。  相似文献   

20.
The present investigation deals with the effect of the concentration of calcined petroleum coke (CPC) on the dry sliding wear characteristics of elastomer modified phenolic resin-based friction composites. Other ingredients common in brake formulations like fiber, filler, and solid lubricant were excluded in the present formulations to understand the exclusive effect of the CPC concentration on the frictional, mechanical, and thermal properties of these composites. The composites were fabricated by hot mixing followed by compression molding, and subsequent post-curing. The coefficient of friction (COF) and the specific wear rate of these composites sliding against a cast-iron disc were measured and analyzed. The change in surface topography of these composites before and after sliding operation was investigated by scanning electron microscopy. An effort was made to correlate the surface morphology of these composites before and after sliding with friction and wear behavior. The investigation reveals that CPC inclusion improved the anti-wear behavior as it formed a uniform transfer layer over the rubbing surfaces. In case of optimum CPC loaded (200 phr) composite, the average COF and thermal conductivity values were found to be 0.15 and 0.61 W/m-K, respectively, as compared to 0.12 and 0.25 W/m-K for the base composite (without any CPC).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号