首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Rapid and convenient structural analysis of neutral glycosphingolipids (GSLs) was achieved by direct coupling of thin-layer chromatography (TLC) to matrix-assisted laser desorption/ionization quadrupole ion trap time-of-flight (MALDI-QIT-TOF) MS/MS. Positions of unstained GSL spots on developed TLC plates were determined by comparison to orcinol-stained references. A matrix solution of 2,5-dihydroxybenzoic acid (DHB) in acetonitrile/water (1:1 v/v) was then added directly to the unstained GSL spots, and the GSLs were directly analyzed by MALDI-QIT-TOF MS. The acetonitrile/water DHB solution proved to be suitable for MS/MS structural analysis with high sensitivity. MS/MS and MS/MS/MS of GSLs yielded simple and informative spectra that revealed the ceramide and long-chain base structures, as well as the sugar sequences. Hydroxy fatty acids in ceramide provided characteristic MS/MS fragment ions. GSLs were stained with primuline, a nondestructive dye, after TLC development, and successfully analyzed by MALDI-QIT-TOF MS/MS with high sensitivity. Immunostaining of GSLs after TLC development is a powerful method for characterizing antibody-specific sugars, but not ceramides. By coupling TLC-immunostaining of GSLs to MALDI-QIT-TOF MS/MS, we were able to identify both the sugar and the ceramide structures. The detection limits of asialo GM1 (Galbeta1-3GalNAcbeta1-4Galbeta1-4Glcbeta1-1'Cer) were 25 and 50 pmol in primuline staining and immunostaining, respectively.  相似文献   

2.
Glycosphingolipids (GSLs), composed of a hydrophilic carbohydrate chain and a lipophilic ceramide anchor, play pivotal roles in countless biological processes, including the development of cancer. As part of the investigation of the vertebrate glycome, GSL analysis is undergoing rapid expansion owing to the application of modern mass spectrometry. Here we introduce direct coupling of IR-MALDI-o-TOF mass spectrometry with the TLC overlay binding assay for the structural characterization of GSLs. We matched three complementary methods including (i) TLC separation of GSLs, (ii) their detection with oligosaccharide-specific proteins, and (iii) in situ MS analysis of protein-detected GSLs. The high specificity and sensitivity is demonstrated by use of antibodies, bacterial toxins, and a plant lectin. The procedure works on a nanogram scale, and detection limits of less than 1 ng at its best of immunostained GSLs were obtained. Furthermore, only crude lipid extracts of biological sources are required for TLC-IR-MALDI-MS, omitting any laborious GSL downstream purification procedures. This strategy was successfully applied to the identification of cancer-associated GSLs in human hepatocellular and pancreatic tumors. Thus, the in situ TLC-IR-MALDI-MS of immunolabeled GSLs opens new doors by delivering specific structural information of trace quantities of GSLs with only a limited investment in sample preparation.  相似文献   

3.
A combined strategy of preparative high-performance thin-layer chromatography overlay assay and mass spectrometry was established for the structural characterization of immunostained glycosphingolipids (GSLs) in silica gel extracts. Crude chloroform/methanol/water (30/60/8, v/v/v) extracts of immunostained TLC bands were analyzed by nanoelectrospray low-energy CID mass spectrometry without further purification. The GSL species investigated were isomeric monosialogangliosides of the neolacto series from a ganglioside preparation of human granulocytes, the disialoganglioside GD3 from a human melanoma lipid extract, and ganglio series Gg3Cer of a neutral GSL preparation from murine lymphoreticular MDAY-D2 cells. For the specific detection of lipid-bound oligosaccharides, polyclonal chicken IgY, murine monoclonal IgG3, and IgM antibodies were used. The resulting mass spectra show that only analytical quantities of approximately 1 microg of a single GSL within a complex mixture are required for the structure determination of immunostained GSLs by MS and MS/MS. All species investigated were detected as singly charged deprotonated molecular ions, and neither buffer-derived salt adducts nor coextracted contaminants from the immunostaining procedure or the silica gel layer were observed. This effective HPTLC-MS-joined procedure offers a wide range of applications for any carbohydrate binding agents such as bacterial toxins, plant lectins, and others.  相似文献   

4.
ESI (electrospray ionization) MS and tandem mass spectrometry (MS/MS) were used for the analysis of single nucleotide polymorphisms (SNPs) and more complex genetic variations. Double-stranded (ds) PCR products were studied. PCR products of the proline [5'-x(G17)-x(C38)x-3'] and arginine variants [(5'-x(Gl7)-x(G38)x-3'] of the p53 gene are distinguished by an SNP (cytosine or guanine) and were discriminated using both quadrupole and quadrupole ion trap MS analysis. A 69 bp arginine mutant PCR product [5'-x(C17)-x(G38)x-3'] with a negating switch has the same mass as the proline variant but was readily distinguishable on ion trap MS/MS analysis; fragments containing the mutation site, but not the polymorphism, were identified. The 69 bp PCR products were restriction-enzyme-digested, to create 43 bp fragments. ESI quadrupole ion trap MS/MS analysis of the 43 bp product-ion spectra readily demonstrated both polymorphism and negating switch sites. MS and MS/MS are powerful and complementary techniques for analysis of DNA. MS can readily distinguish SNPs but MS/MS is required to differentiate isomeric PCR products (same nucleotide composition but different sequence).  相似文献   

5.
Electrospray ionization mass spectrometry (ESI-MS) has become a standard method for monitoring noncovalent protein-protein interactions. Studies employing this approach tend to operate on the premise that the ionic species observed in the mass spectrum directly reflect the corresponding solution-phase protein quaternary structures. However, dissociation or clustering events taking place during ESI may lead to disparities between the ions observed in the mass spectrum and the protein binding state in bulk solution. Recognizing the occurrence of dissociation or clustering artifacts is not straightforward, leading to possible ambiguities in the interpretation of ESI-MS data. This work employs on-line pulsed hydrogen-deuterium exchange (HDX) for probing the origin of various species in the ESI mass spectrum of hemoglobin. In addition to the canonical hemoglobin tetramer, ESI-MS reveals the presence of monomers, dimers, hexamers, and octamers. Tandem mass spectrometry (MS/MS) is used for extracting HDX levels in a subunit-specific manner. Dimeric species exhibit exchange levels that are significantly above those of the tetramer. Monomeric hemoglobin subunits are labeled to an even greater extent. This HDX pattern implies that monomers and dimers do not represent dissociation artifacts generated during ESI. Instead, they are derived from preexisting solution-phase structures. In contrast, hexamers and octamers exhibit HDX levels that resemble those of the tetramer, thus identifying these larger species as nonspecific clustering artifacts. Overall, it appears that the pulsed HDX MS/MS approach introduced in this work represents a widely applicable tool for deciphering the relationship between ESI mass spectra and protein quaternary structures in solution.  相似文献   

6.
Good reliability of Caco-2 permeability studies requires competent sampling and analytical methods to ensure the comparability of day-to-day experiments. In this work, two n-in-one LC/MS/MS methods based on two different ionization techniques were developed and validated for a group of reference compounds; eight of them are recommended by the Food and Drug Administration (FDA) for the evaluation of oral drug permeability. The performance of a new ionization technique, atmospheric pressure photoionization (APPI), as an interface for quantitative LC/MS analysis was evaluated in comparison to the electrospray ionization (ESI). Generally, the validation parameters, including sensitivity, accuracy, and repeatability, were comparable for the APPI and ESI methods. The main difference was that the linear quantitative range of APPI was 3-4 orders of magnitude (r(2) >/= 0.998) whereas in ESI it was typically 2-3 orders of magnitude (r(2) >/= 0.990). By the APPI and ESI methods, the simultaneous analysis of nine highly heterogeneous compounds was achieved within 5.5-7 min, which leads to significant savings in time and cost of the analyses. The successful validation data indicate the usefulness of both the methods for the rapid and sensitive (LOD values typically 相似文献   

7.
Precise profiling of polar lipids including gangliosides and sulfatides is a necessary step in understanding the diverse physiological role of these lipids. We have established an efficient method for the profiling of polar lipids using reversed-phase nano high-performance liquid chromatography microfluidic chip quadrupole time-of-flight mass spectrometry (nano-HPLC-chip Q-TOF/MS). A microfluidic chip design provides improved chromatographic performance, efficient separation, and stable nanospray while the advanced high-resolution mass spectrometer allowed for the identification of complex isobaric polar lipids such as NeuAc- and NeuGc-containing gangliosides. Lipid classes were identified based on the characteristic fragmentation product ions generated during data-dependent tandem mass spectrometry (MS/MS) experiments. Each class was monitored by a postprocessing precursor ion scan. Relatively simple quantitation and identification of intact ions was possible due to the reproducible retention times provided by the nano-HPLC chip. The method described in this paper was used to profile polar lipids from mouse brain, which was found to contain 17 gangliosides and 13 sulfatides. Types and linkages of the monosaccharides and their acetyl modifications were identified by low-energy collision-induced dissociation (CID) (40 V), and the type of sphingosine base was identified by higher energy CID (80 V). Accurate mass measurements and chromatography unveiled the degree of unsaturation and hydroxylation in the ceramide lipid tails.  相似文献   

8.
Phosphatidyl-myo-inositol mannosides (PIM) are not only important structural components of the mycobacterial envelope but also are major non-peptidic antigens of the host innate and acquired immune responses. Indeed, they are ligands of TLR-2 and they activate CD1-restricted T lymphocytes. In addition, PIM constitute the basic structure of the lipidic anchor of two lipoglycans, lipomannans and lipoarabinomannans, which are important immunomodulators in the course of tuberculosis. The fatty acyl substituents present on PIM molecules play a crucial role for both their physical properties and biological activities. PIM contain four acylation sites, two on the glycerol, one on a mannose, and one on the myo-inositol units. We propose here an analytical procedure, based on mass spectrometry, to determine the structure of the fatty acids present on each of these different acylation sites. We show that the nature of the fatty acids located on both positions of glycerol can be deduced from IRMPD analysis of negative precursor ions from native PIM species, while the fatty acids located on myo-inositol and mannose units can be identified by MALDI-TOF CID MS of protonated and cationized molecular ions. Thus, the combination of MS/MS data obtained from positive and negative pseudomolecular ions generated by ESI or MALDI appears as a powerful approach for the structural characterization of the PIM acyl form structure.  相似文献   

9.
Du F  Bai Y  Bai Y  Liu H 《Analytical chemistry》2010,82(22):9374-9383
Systemins are a class of systemic wound polypeptide hormones that play a central role in mediating defenses against pest attacks and other woundings. It has been desired to develop a sensitive and accurate determination method to monitor trace systemins in plants for the better understanding of molecular mechanisms of the polypeptide hormones. A superior method for accurate identification and quantitative determination of trace systemins in Solanaceous plants is described in this work, which is based on immunoaffinity column (IAC) purification and enrichment followed by liquid chromatography online coupled to electrospray quadrupole time-of-flight mass spectrometry (LC/ESI QTOF MS). The specific antitomato systemin polyclonal antibody had been produced and immobilized on a CNBr-activated Sepharose stationary phase. The prepared IAC was utilized for the extraction and enrichment of tomato systemin (TomSys), potato systemin (PotSys I and PotSys II), pepper systemin (PepSys), and nightshade systemin (NishSys) from Solanaceous plants. Subsequent identification and determination by LC/ESI QTOF MS revealed that the IAC enables efficient and specific enrichment of PotSys I, PotSys II, and especially TomSys. Under the optimized conditions, the developed method was successfully applied in the determination of TomSys in tomato leaves and PotSys I and PotSys II in potato leaves, and it offers detection limits (LODs, S/N =3) of 29, 72, and 135 pg/g and mean recoveries of 92.9%, 56.7%, and 34.8% at three concentrations (1.0, 2.0, and 4.0 ng/g) for TomSys, PotSys I, and PotSys II, respectively.  相似文献   

10.
Glycosphingolipids (GSLs) have been shown to undergo strong interactions with a number of protein toxins, including potential bioterrorism agents such as ricin and botulinum neurotoxin. Characterization of this interaction in recent years has led to a number of studies where GSLs were used as the recognition molecules for biosensing applications. Here, we offer a comparison of quartz crystal microbalance (QCM) sensors for the detection of ricin using antibodies and the GSLs GM1 and asialoGM1, which have been shown to undergo strong interactions with ricin. The presence, orientation, and activity of the GSL and antibody films were confirmed using ellipsometry, Fourier transform infrared spectroscopy (FT-IR), and QCM. It was found that the GSLs offered more sensitive detection limits when directly compared with antibodies. Both GSLs had lower detection limits at 5 microg/mL, approximately 5 times lower than were found for antibodies (25 microg/mL), and their linear detection range extended to the highest concentrations tested (100 microg/mL), almost an order of magnitude beyond the saturation point for the antibody sensors. Potential sites for nonspecific adsorption were blocked using serum albumin without sacrificing toxin specificity.  相似文献   

11.
Divinyl sulfone reacts at pH 8-9 with the alpha-amino groups of N-terminal residues, proline, the epsilon-amino groups of lysine, and the histidine side chains of peptides. This reaction leads to great enhancement of the abundance of the normally weak or missing "a(1)" fragment ion in MS/MS analysis defining the N-terminal residue of a peptide in a digest. This provides "one-step Edman-like" information that, together with a fairly accurately determined mass, often enables one to correctly identify a protein or family of proteins. The applicability of this procedure in proteomics was demonstrated with several peptides and tryptic digests of protein mixtures by LC-MS/MS experiments using a QTOF and MALDI-PSD analyses. Advantages of this approach are its simple chemistry, retention of charge multiplicity, and possibly, shortening of database search time. Used with other MS/MS data, it provides higher confidence in the scores and identification of a protein found in peptide mass fingerprinting. Moreover, this approach has an advantage in "de novo" sequencing due to its ability to decipher the first amino acid of a peptide whose information is normally unavailable in MS/MS spectra.  相似文献   

12.
Molecular weight distributions of fulvic acid from the Suwannee River, Georgia, were investigated by electrospray ionization/quadrupole mass spectrometry (ESI/ QMS), and fragmentation pathways of specific fulvic acid masses were investigated by electrospray ionization/ion trap multistage tandem mass spectrometry (ESI/MST/ MS). ESI/QMS studies of the free acid form of low molecular weight poly(carboxylic acid) standards in 75% methanol/25% water mobile phase found that negative ion detection gave the optimum generation of parent ions that can be used for molecular weight determinations. However, experiments with poly(acrylic acid) mixtures and specific high molecular weight standards found multiply charged negative ions that gave a low bias to molecular mass distributions. The number of negative charges on a molecule is dependent on the distance between charges. ESI/MST/MS of model compounds found characteristic water loss from alcohol dehydration and anhydride formation, as well as CO2 loss from decarboxylation, and CO loss from ester structures. Application of these fragmentation pathways to specific masses of fulvic acid isolated and fragmented by ESI/MST/MS is indicative of specific structures that can serve as a basis for future structural confirmation after these hypothesized structures are synthesized.  相似文献   

13.
Three mass spectrometric techniques have been used and compared for the confirmation of the presence of several pesticides that had been detected in environmental water samples by a previously reported SPE-LC-MS/MS screening method. The 2002/657/EC European Comission Decision establishes the need to obtain at least three identification points (IPs) in order to confirm organic residues and contaminants in live animals and animal products. In this paper, a similar approach has been applied for confirmation of pesticides in water samples, using triple quadrupole mass spectrometry (QqQ), time-of-flight mass spectrometry (TOF), and hybrid quadrupole time-of-flight mass spectrometry (QTOF) to achieve the required IPs. The number of IPs collected, the sensitivity, and the practical advantages and disadvantages of these techniques have been discussed. In summary, the QqQ instrument allowed the confirmation of detected pesticides even at very low concentrations (ng/L) achieving between four and five IPs when adding confirmatory transitions. The direct confirmation with a TOF instrument was only feasible for those compounds showing sufficient sensitivity, isotopic pattern, or easy in-source fragmentation. In other cases, the required IPs could be reached by adding IPs earned with this technique to those obtained from the MS/MS screening method. Finally, the use of a QTOF instrument allowed obtaining up to 20 IPs in a single run at relatively high concentrations (submicrograms per liter) as no "ion shopping" was required. Additionally, the application of TOF and QTOF techniques made it possible to detect some nontarget organic contaminants, which were not included in the screening method.  相似文献   

14.
An evaluation of over 75 pesticides by high-performance liquid chromatography/mass spectrometry (HPLC/MS) clearly shows that different classes of pesticides are more sensitive using either atmospheric pressure chemical ionization (APCI) or electrospray ionization (ESI). For example, neutral and basic pesticides (phenylureas, triazines) are more sensitive using APCI (especially positive ion). While cationic and anionic herbicides (bipyridylium ions, sulfonic acids) are more sensitive using ESI (especially negative ion). These data are expressed graphically in a figure called an ionization-continuum diagram, which shows that protonation in the gas phase (proton affinity) and polarity in solution, expressed as proton addition or subtraction (pKa), is useful in selecting APCI or ESI. Furthermore, sodium adduct formation commonly occurs using positive ion ESI but not using positive ion APCI, which reflects the different mechanisms of ionization and strengthens the usefulness of the ionization-continuum diagram. The data also show that the concept of "wrong-way around" ESI (the sensitivity of acidic pesticides in an acidic mobile phase) is a useful modification of simple PKa theory for mobile-phase selection. Finally, this finding is used to enhance the chromatographic separation of oxanilic and sulfonic acid herbicides while maintaining good sensitivity in LC/MS using ESI negative.  相似文献   

15.
Diagnosing and treating anthrax at the earliest stage of disease is critical. We developed a method to diagnose anthrax at early stages of infection by detecting anthrax lethal factor (LF) at the attomol/mL level in plasma or serum. This method uses antibody capture and quantification of LF endoproteinase activity by isotope dilution matrix-assisted laser-desorption ionization (MALDI) time-of-flight (TOF) mass spectrometry (MS). Many public health laboratories do not use MALDI-TOF-MS; thus, we have adapted the LF method for detection by electrospray ionization (ESI) tandem MS (MS/MS), which allowed comparison of both MS platforms for LF quantification. Calibration curves were linear from 0.05-2.5 ng/mL when measured after 2 h and from 0.005-1.0 ng/mL after 18 h incubation time. The limit of detection was 0.005 ng/mL using a 200 μL sample. The coefficient of variation for quality control samples was 6-12% for both MS platforms. Samples used to perform cross-validation included 158 serum samples from a study in rabbits exposed to anthrax spores by inhalation. Some were treated with anthrax immune globulin before exposure. Concentrations measured by ESI-MS/MS matched those by MALDI-TOF-MS with p = 0.99 (r(2) = 0.997) and -0.25% mean relative difference (±9% standard deviation). This study shows that isotope dilution MALDI-TOF-MS is a robust and precise quantitative MS platform.  相似文献   

16.
A screening technique has been developed that allows the rapid, real-time detection and identification of major transformation products of organic contaminants during aqueous oxidation experiments. In this technique, a target contaminant is dissolved in buffered water and chlorinated by the addition of sodium hypochlorite to give a free chlorine residual of 3 mg/L. Solution from the reaction vessel is combined with methanol and pumped directly into the electrospray ionization source of a quadrupole time-of-flight mass spectrometer (QTOF MS). The real-time decay of the target contaminant and the formation/decay of transformation products are then monitored using the QTOF MS. Subsequently, accurate mass measurements with internal mass calibration (<5 ppm mass error) and product ion scans are employed to identify these transformation products. Unlike other techniques, it requires no liquid chromatography, derivatization, or quenching of residual chlorine, all of which can interfere with transformation product analysis. To validate the technique, aqueous chlorination experiments were performed on triclosan, a previously studied environmental contaminant. Earlier research showing that triclosan underwent chlorine addition to form mono- and dichlorinated transformation products was successfully reproduced, demonstrating the feasibility of the technique. In addition, the technique revealed the formation of a stable oxygen radical-containing transformation product resulting from the oxidation of either mono- or dichlorinated triclosan. This triclosan transformation product was determined to have an empirical formula of C12H4O3Cl4 with 3.9 ppm mass error. Furthermore, atorvastatin, a commonly prescribed medication and environmental contaminant, was subjected to aqueous chlorination and studied with the technique. Atorvastatin underwent hydroxylation to form two transformation products with the empirical formulas C33H34FN2O6 (1.8 ppm mass error) and C26H29O5NF (2.9 ppm mass error).  相似文献   

17.
Cardiac glycosides (CG) are of forensic importance because of their toxicity and the fact that very limited methods are available for identification of CG in biological samples. In this study, we have developed an identification and quantification method for digoxin, digitoxin, deslanoside, digoxigenin, and digitoxigenin by high-performance liquid chromatography tandem mass spectrometry (HPLC/MS/MS). CG formed abundant [M + NH4]+ ions and much less abundant [M + H]+ ions as observed with electrospray ionization (ESI) source and ammonium formate buffer. Under mild conditions for collision-induced dissociation (CID), each [M + NH4]+ ion fragmented to produce a dominant daughter ion, which was essential to the sensitive method of selected reaction monitoring (SRM) quantification of CG achieved in this study. SRM was compared with selected ion monitoring (SIM) regarding the effects of sample matrixes on the methodology. SRM produced lower detection limits with biological samples than SIM, while both methods produced equal detection limits with CG standards. On the basis of the HPLC/MS/MS results for CG, we have proposed some generalized points for conducting sensitive SRM measurements, in view of the property of analytes as well as instrumental conditions such as the type of HPLC/MS interface and CID parameters. Analytes of which the molecular ion can produce one abundant daughter ion with high yield under CID conditions may be sensitively measured by SRM. ESI is the most soft ionization source developed so far and can afford formation of the fragile molecular ions that are necessary for sensitive SRM detection. Mild CID conditions such as low collision energy and low pressure of collision gas favor production of an abundant daughter ion that is essential to sensitive SRM detection. This knowledge may provide some guidelines for conducting sensitive SRM measurements of very low concentrations of drugs or toxicants in biological samples.  相似文献   

18.
Wang N  Li L 《Analytical chemistry》2008,80(12):4696-4710
In shotgun proteome analysis by liquid chromatography-tandem mass spectrometry (LC-MS/MS), not all coeluting peptides at a given retention time are subjected to MS/MS due to the limitation of spectral acquisition speed of a mass spectrometer. In this work, precursor ion exclusion (PIE) in an electrospray ionization (ESI) quadrupole time-of-flight (QTOF) mass spectrometer was explored as a means of mitigating the undersampling problem. This strategy is based on running replicates of the sample where the precursor ions detected in the initial run(s) are excluded for MS/MS in the subsequent run. Four PIE methods as well as running replicates without PIE were investigated and compared for their effectiveness in identifying peptides and proteins. In the analysis of an MCF-7 breast cancer cell lysate digest by three replicate 2 h gradient LC-ESI runs, the first PIE method used a list of precursor ions detected in the initial run(s) for exclusion and identified a total of 572 proteins from the three runs combined with an average of 3.59 peptides matched to a protein. The second PIE method involved in the generation of a list of m/ z values of precursor ions along with their retention time information from the initial run(s), followed by entering these ions with retention times into the ion exclusion program of the QTOF control software for exclusion at a predefined retention time window (i.e., +/-150 s). In comparison to the first PIE method, this method reduced the possibility of excluding different peptide ions of the same m/ z (within a mass tolerance window) eluted at different retention windows. A total of 657 proteins were identified with an average of 3.75 peptides matched to a protein. The third PIE method studied relied on the exclusion of the precursor ions of peptides identified through database search of the MS/MS spectra generated in the initial run(s). This selective PIE method identified a total of 681 proteins with an average of 3.68 peptides matched to a protein. The final PIE method investigated involves the expansion of the selective PIE list by including nonidentifiable peptide ions found in the database search. This complete PIE method identified a total of 726 proteins with an average of 3.66 peptides per protein. In the case of three replicate runs without PIE, a total of 460 proteins were identified with an average of 3.51 peptides matched to a protein. Thus, the use of an optimal PIE strategy significantly increased the number of proteins identified from replicate runs (i.e., 726 vs 460 or a 58% increase). It is further demonstrated that this PIE strategy also improves protein identification efficiency in the analysis of a yeast whole cell lysate digesta less complex proteome digest. A total of 533 proteins identified from five replicate runs with complete PIE, compared to 353 proteins identified from the five replicate runs without PIE, representing a 51% increase in the number of proteins identified.  相似文献   

19.
The capability for sensitive and accurate identification of microorganisms has potential applications that include the monitoring of industrial bioprocessing operations, food safety analyses, disease diagnosis, and detection of potential biological hazards. Efforts based upon matrix-assisted laser desorption/ionization mass spectrometry to detect and identify specific microorganisms have been actively pursued for several years. We report a new method being developed to select useful biomarkers for the identification of microorganisms based upon electrospray ionization (ESI)-ion trap mass spectrometry. Crude cell lysates are processed using a recently developed dualmicrodialysis device and then directly infused into an ion trap MS. The low ESI flow rate and precursor ion accumulation capability of the ion trap MS enables high-sensitivity MS/MS analyses. Precursor ions are automatically selected and analyzed using tandem MS (MS/MS) to produce "global" MS/MS surveys and processed to yield two-dimensional MS/MS spectral displays. Such global MS/MS surveys are demonstrated for Escherichia coli lysates. The distinctive MS/MS spectral patterns can be used to identify mass spectrometric-detected species useful as biomarkers, which then provide a basis for confident microorganism identification. The results presented demonstrate the application of this method for the identification of microorganisms, as well as for detection of bacteriophage MS2 in the presence of a large excess of E. coli.  相似文献   

20.
Li X  Franke AA 《Analytical chemistry》2011,83(8):3192-3198
We report a new method for fast and sensitive analyses of biologically relevant fatty acids (FAs) in red blood cells (RBC) by liquid chromatography mass spectrometry (LC-MS). A new chemical derivatization approach was developed forming picolylamides from FAs in a quantitative reaction. Fourteen derivatized FA standards, including saturated and unsaturated FAs from C14 to C22, were efficiently separated within 15 min. In addition, the use of a recently introduced benchtop orbitrap mass spectrometer under positive electrospray ionization (ESI) full scan mode showed a 2-10-fold improvement in sensitivity compared with a conventional tandem MS method, with a limit of detection in the low femtomole range for saturated and unsaturated FAs. The developed method was applied to determine FA concentrations in RBC with intra- and interday coefficients of variation below 10%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号