首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Laser-induced breakdown spectroscopy (LIBS) is presented for detection of several Group I and II elements (e.g., Na, Ca, Li, and K), as well as Mn and CaOH, in bulk aqueous solution at pressures exceeding 2.76 x 10(7) Pa (276 bar). Preliminary investigations reveal only minor pressure effects on the emission intensity and line width for all elements examined. These effects are found to depend on detector timing and laser pulse energy. The results of these investigations have implications for potential applications of LIBS for in situ multi-elemental detection in deep-ocean environments.  相似文献   

2.
Sequential-pulse (or dual-pulse) laser-induced breakdown spectroscopy (DP-LIBS) with an orthogonal spark orientation is described for elemental analysis of bulk aqueous solutions at pressures up to approximately 138 x 10(5) Pa (138 bar). The use of sequential laser pulses for excitation, when compared to single-pulse LIBS excitation (SP-LIBS), provides significant emission intensity enhancements for a wide range of elements in bulk solution and allows additional elements to be measured using LIBS. Our current investigations of high-pressure solutions reveal that increasing solution pressure leads to a significant decrease in DP-LIBS emission enhancements for all elements examined, such that we see little or no emission enhancements for pressures above 100 bar. Observed pressure effects on DP-LIBS enhancements are thought to result from pressure effects on the laser-induced bubble formed by the first laser pulse. These results provide insight into the feasibility and limitations of DP-LIBS for in situ multi-elemental detection in high-pressure aqueous environments like the deep ocean.  相似文献   

3.
Laser-induced breakdown spectroscopy (LIBS) has been evaluated as a tool for monitoring trace levels of helium in gas mixtures consisting mostly of hydrogen. Calibration data for helium in hydrogen was investigated at different helium concentration levels. At high concentrations of helium (>7.25%), the LIBS signal is quenched due to Penning ionization. The hydrogen alpha line (656.28 nm) was observed to broaden as the concentration of helium impurities in the hydrogen gas mixture increased. The helium line at 587.56 nm was selected as the analyte line for helium impurity detection. The effects of laser energy, the delay time between the laser pulse and data acquisition, and the gas pressure on the LIBS signal of helium were investigated to determine the optimum conditions for helium detection. The LIBS signal from the helium line at 587.56 nm shows good linear correlation with helium concentration for He concentrations below 1%. Thus, LIBS can be reliably used to detect the low levels of helium. The limit of detection for helium was found to be 78 ppm.  相似文献   

4.
In this work, plasma characterization by laser-induced breakdown spectroscopy (LIBS) has been investigated. We propose a method based on the calculation of the optical thicknesses of emission spectral lines in the framework of a homogeneous optically thick plasma in local thermodynamic equilibrium (LTE). In this approach, self-absorption is taken into account to retrieve the optically thin intensities and plasma characterization is achieved. The developed procedure is applied to magnesium (Mg) lines measured from plasmas generated in air at atmospheric pressure from calcium hydroxide samples using an infrared Nd:YAG laser. The influence of laser irradiance on both plasma shape and emission intensity was studied to select the most suitable experimental conditions. Spectral lines of Mg I-II were measured and analyzed for different laser energies, delay times, and concentrations of the analyte. In each case, the plasma temperature, the electron density, and the parameters Nl were determined, without employing curves-of-growth. The results obtained showed the practical usefulness of the method to provide valuable information in LIBS experiments.  相似文献   

5.
Rai VN  Yueh FY  Singh JP 《Applied optics》2003,42(12):2094-2101
The application of laser-induced breakdown spectroscopy to liquid samples, by use of a Nd:YAG laser in double-pulse excitation mode, is described. It is found that the line emission from a magnesium ion or atom is more than six times greater for double-pulse excitation than for single-pulse excitation. The effect of interpulse separation on the emission intensity of a magnesium ion and a neutral atom showed an optimum enhancement at a delay of 2.5-3 micros. The intensity of neutral atomic line emission dominates the ion emission from the plasma for higher interpulse (>10 micros) separation. A study of the temporal evolution of the line emission from the plasma shows that the background as well as line emission decays faster in double-pulse excitation than in single-pulse excitation. The enhancement in the emission seems to be dominated by an increase in the volume of the emitting gas. The limit of detection for a magnesium solution improved from 230 parts per billion (ppb) in single-pulse mode to 69 ppb in double-pulse mode.  相似文献   

6.
We report on rapid in situ analysis of liquid metal melts under reduced ambient pressure by laser-induced breakdown spectroscopy (LIBS) using a transportable system. LIBS denotes a method in which characteristic optical emission line intensities of excited species in laser-generated plasma plumes are used for a quantitative chemical analysis of target materials. It is a fast, noncontact method that can be carried out under various atmospheric conditions, allowing large working distances between the sample under investigation and the detection system. For these reasons, LIBS is applicable in particular for process control in metallurgy under reduced ambient pressure. This was demonstrated for two types of vacuum devices under production conditions at a steel mill. The results of these experiments, including calibration curves for Cr, Ni, and Mg in liquid steel, are presented. The influence of variations in the ambient pressure on the results of the LIBS analysis is discussed within the frame of a generalized shock-wave model for the expansion of the laser-induced plasma plume.  相似文献   

7.
We present a method to achieve separation and indirect detection of nonfluorescent species using fluorescent mobility markers. This technique leverages isotachophoresis (ITP) for both preconcentration and separation. We employ a leading electrolyte (LE), trailing electrolyte (TE), and a set of fluorescent markers of mobilities designed to bound those of nonfluorescent analytes of interest. Fluorescent markers and nonfluorescent analytes are initially mixed homogenously and ITP is initiated. The dynamics of isotachophoresis cause the analyte and fluorescent marker mixture to segregate into respective zones between the LE and TE in the order of reducing mobility. Unlabeled analytes are detected as gaps (regions with local minimums in intensity) in the fluorescent signals of mobility markers. We have successfully demonstrated preconcentration, separation, and detection of unlabeled amino acids serine, glycine, and phenylalanine; and of acetic acid, aspartic acid, and 3-phenylpropionic acid. We show detection of 12 microM concentration of analytes with signal-to-noise ratio of 4.0 and with a high degree of repeatability. We discuss methods for encoding mobility marker identity using marker fluorescence intensity level and alternating fluorescence emission wavelengths. We present example experimental results of fluorescence intensity level encoding.  相似文献   

8.
The use of laser-induced breakdown spectroscopy (LIBS) to detect a variety of elements in soils has been demonstrated and instruments have been developed to facilitate these measurements. The ability to determine nitrogen in soil is also important for applications ranging from precision farming to space exploration. For terrestrial use, the ideal situation is for measurements to be conducted in the ambient air, thereby simplifying equipment requirements and speeding the analysis. The high concentration of nitrogen in air, however, is a complicating factor for soil nitrogen measurements. Here we present the results of a study of LIBS detection of nitrogen in sand at atmospheric and reduced pressures to evaluate the method for future applications. Results presented include a survey of the nitrogen spectrum to determine strong N emission lines and determination of measurement precision and a detection limit for N in sand (0.8% by weight). Our findings are significantly different from those of a similar study recently published regarding the detection of nitrogen in soil.  相似文献   

9.
To probe directly the analyte/film interactions that characterize molecular recognition in gas sensors, we recorded changes to the in situ surface vibrational spectra of specifically functionalized surface acoustic wave (SAW) devices concurrently with analyte exposure and SAW measurement of the extent of sorption. Fourier transform infrared external-reflectance spectra (FT-IR-ERS) were collected from operating 97-MHz SAW delay lines during exposure to a range of analytes as they interacted with thin-film coatings previously shown to be selective: cyclodextrins for chiral recognition, nickel camphorates for Lewis bases such as pyridine or organophosphonates, and phthalocyanines for aromatic compounds. In most cases where specific chemical interactions--metal coordination, "cage" compound inclusion, or pi-stacking--were expected, analyte dosing caused distinctive changes in the IR spectra, together with anomalously large SAW sensor responses. In contrast, control experiments involving the physisorption of the same analytes by conventional organic polymers did not cause similar changes in the IR spectra, and the SAW responses were smaller. For a given conventional polymer, the partition coefficients (or SAW sensor signals) roughly followed the analyte fraction of saturation vapor pressure. These SAW/FT-IR results support earlier conclusions derived from thickness-shear mode resonator data.  相似文献   

10.
A project called MALIS (Mars Analysis by Laser-Induced breakdown Spectroscopy) is under progress to perform in situ analysis of Mars soils and rocks. This paper reports on the behavior of plasma in Martian conditions, i.e., in a CO2 atmosphere at pressures between 5 and 12 mbar. Plasma expansion and lifetime have been studied in order to compare plasma evolution under standard conditions (air at atmospheric pressure) and in a Mars atmosphere. We have shown that the Mars environment favors plasma expansion and lifetime. The second part of the study concerns optimization of the emission signal from the plasma. An original approach has been chosen, as we used a Doehlert design for the first time in laser-induced breakdown spectroscopy (LIBS). The best conditions obtained are for a laser wavelength of 1064 nm with the maximum energy available due to space limitations, which is 40 mJ at 15 Hz. The other factors studied are delay, angle of incidence, and CO2 pressure. We have shown that these factors do not have the same influence depending on which spectroscopic line is used, i.e., the atomic line or the ionic line.  相似文献   

11.
Tu R  Liu B  Wang Z  Gao D  Wang F  Fang Q  Zhang Z 《Analytical chemistry》2008,80(9):3458-3465
Mn2+-doped ZnS nanocrystals with an amine-capping layer have been synthesized and used for the fluorescence detection of ultratrace 2,4,6-trinitrotoluene (TNT) by quenching the strong orange Mn2+ photoluminescence. The organic amine-capped nanocrystals can bind TNT species from solution and atmosphere by the acid-base pairing interaction between electron-rich amino ligands and electron-deficient aromatic rings. The resultant TNT anions bound onto the amino monolayer can efficiently quench the Mn2+ photoluminescence through the electron transfer from the conductive band of ZnS to the lowest unoccupied molecular orbital (LUMO) of TNT anions. The amino ligands provide an amplified response to the binding events of nitroaromatic compounds by the 2- to approximately 5-fold increase in quenching constants. Moreover, a large difference in quenching efficiency was observed for different types of nitroaromatic analytes, dependent on the affinity of nitro analytes to the amino monolayer and their electron-accepting abilities. The amine-capped nanocrystals can sensitively detect down to 1 nM TNT in solution or several parts-per-billion of TNT vapor in atmosphere. The ion-doped nanocrystal sensors reported here show a remarkable air/solution stability, high quantum yield, and strong analyte affinity and, therefore, are well-suited for detecting the ultratrace TNT and distinguishing different nitro compounds.  相似文献   

12.
The performance and sensitivity of an intensified CCD array system and a nonintensified CCD array detector system are compared for laser-induced breakdown spectroscopy (LIBS). LIBS measurements were recorded in a calcium-based aerosol-seeded gas stream at ambient pressure. The signal-to-noise ratio based on the 393.37-nm calcium emission line was calculated as a function of detector delay with respect to the plasma-initiating laser pulse. Both ensemble-averaging and single-shot spectral analyses were performed. For all conditions, the intensified CCD system provided an enhanced signal-to-noise ratio compared with the nonintensified CCD system.  相似文献   

13.
Laser induced breakdown spectroscopy (LIBS) is shown to be capable of low volume (90 pL) quantitative elemental analysis of picogram amounts of dissolved metals in solutions. Single-pulse and collinear double-pulse LIBS were investigated using a 532 nm dual head laser coupled to a spectrometer with an intensified charge coupled device (CCD) detector. Aerosols were produced using a micronebulizer, conditioned inside a concentric spray chamber, and released through an injector tube with a diameter of 1 mm such that a LIBS plasma could be formed ~2 mm from the exit of the tube. The emissions from both the aerosols and a single microdrop were then collected with a broadband high resolution spectrometer. Multielement calibration solutions were prepared, and continuing calibration verification (CCV) standards were analyzed for both aerosol and microdrop systems to calculate the precision, accuracy, and limits of detection for each system. The calibration curves produced correlation coefficients with R(2) values > 0.99 for both systems. The precision, accuracy, and limit of detection (LOD) determined for aerosol LIBS were averaged and determined for the emission lines of Sr II (421.55 nm), Mg II (279.80 nm), Ba II (493.41 nm), and Ca II (396.84 nm) to be ~3.8% RSD, 3.1% bias, 0.7 μg/mL, respectively. A microdrop dispenser was used to deliver single drops containing 90 pL into the space where a LIBS plasma was generated with a focused laser pulse. In the single drop microdrop LIBS experiment, the analysis of a single drop, containing a total mass of 45 pg, resulted in a precision of 13% RSD and a bias of 1% for the Al I (394.40 nm) emission line. The absolute limits of detection of single drop microdrop LIBS for the emission lines Al I (394.40 nm) and Sr II (421.5 nm) were approximately 1 pg, and Ba II (493.41 nm) produced an absolute detection limit of approximately 3 pg. Overall, the precision, accuracy, and absolute LOD determined for single microdrop LIBS resulted in a typical performance of ~14% RSD, 6% bias, and 1 pg for the elements Sr II (421.55 nm), Al I(394.40 nm), Mg II (279.80), and Ba II(493.41 nm).  相似文献   

14.
Laser-induced breakdown spectroscopy (LIBS) measurements are typically carried out using pulses (<20 ns, >50 mJ) from a flashlamp-pumped electro-optically Q-switched Nd:YAG laser (EO-laser) or excimer laser. Here we report LIBS analyses of solids using an acousto-optically Q-switched Nd:YAG laser (AO-laser) producing 150 ns pulses of lower energy (10 mJ) at repetition rates up to 6 kHz. The high repetition rate allows increased spatial or depth sampling over a given time period compared to the EO-laser. Results of AO-laser based LIBS analysis of (1) steels, (2) soils, and (3) surface stains and dusts are described. Detection limits for Cr, Cu, Mn, Ni, and Si in steel ranged from 0.11 to 0.24% using a commercial polychromator-based detection system with limits 4--30 times lower achieved using a laboratory-based detection system. The minimum detectable masses of Ba, Cr, Mn, and Sr on a metal surface were estimated with 1.2 pg/shot achieved for Sr. Detection limits for Ba and Sr in soil were 296 and 52 ppm, respectively. The temperatures, spectra, and emission decay curves from plasmas generated by the AO- and EO-lasers are compared and some characteristics of particles ablated by the AO-laser are described.  相似文献   

15.
Matrix-assisted laser desorption/ionization (MALDI) has proven an effective tool for fast and accurate determination of many molecules. However, the detector sensitivity and chemical noise compromise the detection of many invaluable low-abundance molecules from biological and clinical samples. To challenge this limitation, we developed a targeted analyte detection (TAD) technique. In TAD, the target analyte is selectively elevated by spiking a known amount of that analyte into the sample, thereby raising its concentration above the noise level, where we take advantage of the improved sensitivity to detect the presence of the endogenous analyte in the sample. We assessed TAD on three peptides in simple and complex background solutions with various exogenous analyte concentrations in two MALDI matrices. TAD successfully improved the limit of detection (LOD) of target analytes when the target peptides were added to the sample in a concentration close to optimum concentration. The optimum exogenous concentration was estimated through a quantitative method to be approximately equal to the original LOD for each target. Also, we showed that TAD could achieve LOD improvements on an average of 3-fold in a simple and 2-fold in a complex sample. TAD provides a straightforward assay to improve the LOD of generic target analytes without the need for costly hardware modifications.  相似文献   

16.
We have developed an on-line analytical system involving microdialysis (MD) sampling, a carbohydrate membrane desalter (CMD), and an inductively coupled plasma mass spectrometer (ICPMS) system for the simultaneous determination of multiple trace metals in the extracellular fluid (ECF) in the brains of anesthetized rats. The microdialysate that perfused from the animal at a flow rate of 0.5 microL/min was on-line transferred to the CMD to remove the high-sodium matrix, followed by ICPMS measurement. The role of the CMD in this on-line system was investigated in detail. With prior addition of EDTA to the microdialysate to form anionic complexes of the metal analytes and the use of NH4Cl as a regenerant to exchange Na(+) with NH4(+) ions, both quantitative recovery of the trace metal analytes and quantitative removal of the sodium matrix could be achieved. Two experimental modes of the monitoring system were constructed. For those metals (e.g., Cu, Zn, and Mn) that existed at (sub)nanogram-per-milliliter concentrations in the microdialysate, the temporal resolution was 10 min when using a 10 microL loop for sample collection, followed by CMD and ICPMS; for those elements (e.g., Ca and Mg) that existed at microgram-per-milliliter levels (or greater), near-real-time analysis was possible because the microdialysate could be led, bypassing the sample loop, directly to the CMD for desalting without any time delay. Further improvement of the temporal resolution for the low-concentration elements was not possible without decreasing the detection limits of mass detection. Among the eight trace metals tested using this on-line system, the method detection limits for Cu, Zn, Mn, Co, Ni, and Pb reached subnanogram-per-milliliter levels; for electrolyte species such as Ca and Mg, the detection limits were in the range of 50-100 ng/mL. Analytical accuracy, expressed as spike recovery, was 100% +/- 15% for all of the elements tested. We demonstrate the applicability of the proposed system through the successful measurement of the basal values of Ca, Mg, Cu, Zn, and Mn in the ECF of a living rat brain and through in vivo monitoring of the concentration profiles of Mn and Pt in the ECF after the injection of drugs (MnCl2 and cisplatin) into the rats. This microdialysis system is the first to offer real-time, in vivo monitoring of trace elements such as Ca and Mg.  相似文献   

17.
Pearman W  Scaffidi J  Angel SM 《Applied optics》2003,42(30):6085-6093
Use of dual-pulse laser-induced breakdown spectroscopy with an orthogonal spark orientation is presented as a technique for trace metal analysis in bulk aqueous solutions. Two separate Q-switched Nd:YAG lasers operating at their fundamental wavelengths are used to form a subsurface, laser-induced plasma in a bulk aqueous solution that is spectroscopically analyzed for the in situ detection of Ca, Cr, and Zn. Optimizing the key experimental parameters of proper spark alignment, gate delay (td), gate width (tb), and interpulse timing (deltaT) allowed experimentally determined detection limits of the order of micrograms per milliliter and submicrograms per milliliter. We present supporting evidence of a sampling mechanism that involves the formation of a cavitation bubble with the first pulse (E1) followed by analysis of that bubble with a second pulse (E2). The plasma created by E2 contains the analytically relevant information from the aqueous sample and often represents >250-fold enhancement over a single laser pulse with energy equal to E1 alone.  相似文献   

18.
Liu J  Lee JH  Lu Y 《Analytical chemistry》2007,79(11):4120-4125
One major challenge in analytical chemistry is multiplex sensing of a number of analytes with each analyte displaying a different signal. To meet such a challenge, quantum dots that emit at 525 and 585 nm are used to encode aptamer-linked nanostructures sensitive to adenosine and cocaine, respectively. In addition to quantum dots, the nanostructures also contain gold nanoparticles that serve as quenchers. Addition of target analytes disassembles the nanostructures and results in increased emission from quantum dots. Simultaneous colorimetric and fluorescent detection and quantification of both molecules in one pot is demonstrated.  相似文献   

19.
Advances in the separation and functionalization of single walled carbon nanotubes (SWCNT) by their electronic type have enabled the development of ratiometric fluorescent SWCNT sensors for the first time. Herein, single chirality SWCNT are independently functionalized to recognize either nitric oxide (NO), hydrogen peroxide (H2O2), or no analyte (remaining invariant) to create optical sensor responses from the ratio of distinct emission peaks. This ratiometric approach provides a measure of analyte concentration, invariant to the absolute intensity emitted from the sensors and hence, more stable to external noise and detection geometry. Two distinct ratiometric sensors are demonstrated: one version for H2O2, the other for NO, each using 7,6 emission, and each containing an invariant 6,5 emission wavelength. To functionalize these sensors from SWCNT isolated from the gel separation technique, a method for rapid and efficient coating exchange of single chirality sodium dodecyl sulfate‐SWCNT is introduced. As a proof of concept, spatial and temporal patterns of the ratio sensor response to H2O2 and, separately, NO, are monitored in leaves of living plants in real time. This ratiometric optical sensing platform can enable the detection of trace analytes in complex environments such as strongly scattering media and biological tissues.  相似文献   

20.
Characteristics of microwave plasma induced by lasers and sparks   总被引:1,自引:0,他引:1  
Ikeda Y  Tsuruoka R 《Applied optics》2012,51(7):B183-B191
Characteristics of the plasma light source of microwave (MW) plus laser-induced breakdown spectroscopy (LIBS) or spark-induced breakdown spectroscopy (SIBS) were studied. The plasma was initially generated by laser- or spark-induced breakdown as a plasma seed. A plasma volume was then grown and sustained by MWs in air. This MW plasma had a long lifetime, large volume, strong emission intensity, and high stability with time. These characteristics are suitable for applications in the molecular analysis of gases such as OH or N(2). Because the plasma properties did not depend on laser or spark plasma seeds, the resulting plasma was easily controllable by the input power and duration of the MWs. Therefore, a significant improvement was achieved in the spectral intensity and signal-to-noise ratio. For example, the peak intensity of the Pb spectra of LIBS increased 15 times, and that of SIBS increased 880 times without increases in their background noise. A MW-enhanced plasma light source could be used to make the total system smaller and cheaper than a conventional LIBS system, which would be useful for real-time and in situ analysis of gas molecules in, for example, food processing, medical applications, chemical exposure, and gas turbine or automobile air-to-fuel ratio and exhaust gas measurement.  相似文献   