首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This paper describes a method of removing blurs in scanning electron microscopy (SEM) images caused by the existence of a finite beam size. Although the resolution of electron microscopy images has been dramatically improved by the use of high-brightness electron guns and low-aberration electron lenses, it is still limited by lens aberration and electron diffraction. Both are inevitable in practical electron optics. Therefore, a further reduction in resolution by improving SEM hardware seems difficult. In order to overcome this difficulty, computer deconvolution has been proposed for SEM images. In the present work, the SEM image is deconvoluted using the electron beam profile estimated from beam optics calculation. The results show that the resolution of the deconvoluted image is improved to one half of the resolution of the original SEM image.  相似文献   

2.
A simplified and standardized technique for close correlation between light microscopy (LM), transmission electron microscopy (TEM) and scanning electron microscopy (SEM) is described. Perfusion and immersion fixed tissue specimens were embedded in Epon 812 and cut for conventional LM and TEM. The Epon blocks with remaining tissue were thereafter treated with epoxy solvent (ethanol-NaOH solution) for partial epoxy resin removal only (dissolving rate approx 33μm/h). The blocks with partially blotted tissue specimens were then critically point dried and gold coated for SEM. This method, in an easy way, allows repeated observations with LM, TEM and SEM with preserved fine structure and exact correlation. Since the technique is so simple and there is no need for special equipment the method can easily be adopted in all laboratories with basic SEM standards.  相似文献   

3.
Two simple techniques are described and illustrated. The first is for the study of one specimen by both light microscopy (LM) and scanning electron microscopy (SEM). The second is for the study of one selected specimen by LM, SEM and in ultrathin section by transmission electron microscopy (TEM). Although these techniques were developed for the comparative study of Precambrian organic walled microfossils (OWMs), they could be used for a wide range of other specimens.  相似文献   

4.
A consortium of microorganisms with the capacity to degrade crude oil has been characterized by means of confocal laser scanning microscopy (CLSM), transmission electron microscopy (TEM), and scanning electron microscopy (SEM). The analysis using CLSM shows that Microcoleus chthonoplastes is the dominant organism in the consortium. This cyanobacterium forms long filaments that group together in bundles inside a mucopolysaccharide sheath. Scanning electron microscopy and transmission electron microscopy have allowed us to demonstrate that this cyanobacterium forms a consortium primarily with three morphotypes of the heterotrophic microorganisms found in the Microcoleus chthonoplastes sheath. The optimal growth of Microcoleus consortium was obtained in presence of light and crude oil, and under anaerobic conditions. When grown in agar plate, only one type of colony (green and filamentous) was observed.  相似文献   

5.
A scanning electron microscope of ultra-high-vacuum (UHV-SEM) with a field emission gun (FEG) is operated at the primary electron energies of from 100 eV to 3 keV. The instrument can form the images that contain information on surface chemical composition, chemical bonding state (electronic structure), and surface crystal structure in a microscopic resolution of several hundred angstroms (Å) using the techniques of scanning Auger electron microscope, scanning electron energy loss microscope, and scanning low-energy electron diffraction (LEED) microscope. A scanning tunneling microscope (STM) also has been combined with the SEM in order to obtain the atomic resolution for the solid surface. The instrumentation and examples of their applications are presented both for scanning LEED microscopy and STM.  相似文献   

6.
A method for bacterial identification has been developed by means of studying the same histological sections through several types of microscopy. With this method, one section was processed and analyzed respectively for light microscopy (LM), scanning electron microscopy (SEM), and transmission electron microscopy (TEM). Sections of gingival biopsies were Gram stained and bacteria tentatively identified by LM. Photographs of the sections were taken and presketched transparent acetate sheets (PTAS) were made from the photos. The same section was later prepared for SEM, areas previously thought to contain bacteria were localized by placing the PTAS onto the SEM monitoring screen. The SEM specimens were subsequently processed for TEM, bacteria were located, and micrographs obtained. The results showed that out of ten diseased gingival biopsies observed under the LM, bacteria were found to be present in all the specimens and were identified as both Gram positive and Gram negative. By transferring the section from LM to SEM, the bacteria could be relocated and their morphotype (cocci, rods, etc.) clearly identified in most of the cases. Since cocci may resemble other biological granular structures under SEM, they require further analysis under TEM for additional positive identification. This study demonstrated that the method described here is a useful tool for assessing the presence and identifying bacteria within the gingival tissues.  相似文献   

7.
The modern high-performance personal computer (PC) has very recently expanded the range of utilization of digital scanning electron microscopy (SEM) images, and the PC will be used increasingly with SEMs. However, the image quality of digital SEM images may be considerably influenced by scanning and digitization conditions. In particular, the effects of the aliasing error peculiar to digital data are often serious in the low-magnification acquisition (undersampling) of SEM images, and moreover even a high-magnification image (oversampling) is disturbed by the undersampled noise (a sort of aliasing error). Furthermore, the signal-to-noise ratio of a digitized SEM image is closely related to the performance of the analog-to-digital converter. To prevent a flood of low-quality digital images with artifacts by the aliasing and additional noise, we propose a method using very high-density sampling (scanning). In addition, we will discuss how to handle digital SEM images from the point of view of the sampling and quantization.  相似文献   

8.
Morphologic characterization of polymers by scanning electron microscopy (SEM) is often made difficult by their sensitivity to electron beam damage. We describe here a specimen preparation method for the imaging of polymer blends by low-voltage SEM (LV-SEM) that improves their stability in the electron beam and hence facilitates focusing and recording of high magnification images. Its application to nanosized core-shell latexes embedded in a polymethylmethacrylate matrix and semi-crystalline polypropylene/ethylene-propylene rubber blends is discussed.  相似文献   

9.
Bacterial sample preparation is crucial for its observation by scanning electron microscopy (SEM). However, the current polylysine (PLL) method leads to bacterial morphological changes. To overcome this problem, we employed chitosan (CS) to coat coverslips to prepare bacteria for SEM and compared it with the PLL method. Coverslips coated with 0.025% (w/v) CS showed satisfactory bacterial binding ability. Within 30 min of binding time, the number of bacteria on CS-coated and PLL-coated coverslips exhibited no differences. Four bacteria strains were employed to compare the differences in SEM images between the two methods. Most of the bacteria showed irregular surface or sticky substances after settling on PLL-coated coverslips, while bacteria with clear surface texture were observed on CS-coated coverslips. Transmission electron microscopy (TEM) images showed deformed bacterial envelope on PLL-coated coverslips; meanwhile, similar intact envelope was observed from the bacteria on CS-coated coverslips and the bacteria without any treatment. The TEM results verified the morphological differences of SEM between the two methods. Except for morphology, the length of the rod-shaped bacteria was longer on CS-coated coverslips than that on PLL-coated coverslips, less shrinkage of the sample was observed, and CS could preserve the length of the rod-shaped bacteria better than PLL in its preparation for SEM. It is demonstrated that the low-cost CS could be utilized in bacterial preparation for SEM to acquire preferable images. Bacterial suspension with optical density at 600 nm of about 0.5, deposited on 0.025% CS-coated coverslips for 30 min, and followed by routine fixation, dehydration, and drying are optimal parameters.  相似文献   

10.
Light (video) microscopy and low-temperature scanning electron microscopy (SEM) were used to examine and record images of identical precipitated and metamorphosed snow crystals as well as glacial ice grains. Collection procedures enabled numerous samples from distant locations to be shipped to a laboratory for storage and/or observation. The frozen samples could be imaged with a video microscope in the laboratory at ambient temperatures or with the low-temperature SEM. Stereo images obtained by video microscopy or low-temperature SEM greatly increased the ease of structural interpretations. The preparation procedures that were used for low-temperature SEM did not result in sublimation or melting. However, this technique did provide far greater resolution and depth of focus over that of the video microscope. The advantage of resolution was especially evident when examining the small particles associated with rime and graupel (snow crystals encumbered with frozen water droplets), whereas the greater depth of focus provided clearer photographs of large crystals such as depth hoar, and ice. Because the SEM images contained only surface information while the video images were frequently confounded by surface and internal information, the SEM images also clarified the structural features of depth hoar crystals and ice grains. Low-temperature SEM appears to have considerable promise for future investigations of snow and ice.  相似文献   

11.
A new smoothing filter has been developed for noise removal of scanning electron microscopy (SEM) images. We call this the complex hysteresis smoothing (CHS) filter. It is much easier to use for SEM operators than any other conventional smoothing filter, and it rarely produces processing artifacts because it does not utilize a definite mask (which usually has processing parameters of size, shape, weight, and the number of iterations) like a common averaging filter or a complicated filter shape in the Fourier domain. Its criterion for distinguishing noise depends simply on the amplitude of the SEM signal. When applied to several images with different characteristics, it is shown that the present method has a high performance with some original advantages.  相似文献   

12.
A survey of methods combining light microscopy and scanning electron microscopy is presented. A simple correlation is made when two preparations from adjacent parts of one specimen are investigated in two different microscopes. A more sophisticated method is the consecutive investigation of one specimen with two microscopes. A major problem in this method is the relocation of the area of interest. Several authors have presented solutions for this problem. It is preferable when one preparation is investigated in only one instrument, combining the two microscopical (LM and SEM) techniques, thus making relocation redundant.  相似文献   

13.
Rat liver sinusoidal endothelial cells (LEC) contain fenestrae, which are clustered in sieve plates. Fenestrae control the exchange of fluids, solutes and particles between the sinusoidal blood and the space of Disse, which at its back side is flanked by the microvillous surface of the parenchymal cells. The surface of LEC can optimally be imaged by scanning electron microscopy (SEM), and SEM images can be used to study dynamic changes in fenestrae by comparing fixed specimens subjected to different experimental conditions. Unfortunately, the SEM allows only investigation of fixed, dried and coated specimens. Recently, the use of atomic force microscopy (AFM) was introduced for analysing the cell surface, independent of complicated preparation techniques. We used the AFM for the investigation of cultured LEC surfaces and the study of morphological changes of fenestrae. SEM served as a conventional reference.
AFM images of LEC show structures that correlate well with SEM images. Dried-coated, dried-uncoated and wet-fixed LEC show a central bulging nucleus and flat fenestrated cellular processes. It was also possible to obtain height information which is not available in SEM. After treatment with ethanol or serotonin the diameters of fenestrae increased (+6%) and decreased (−15%), respectively. The same alterations of fenestrae could be distinguished by measuring AFM images of dried-coated, dried-uncoated and wet-fixed LEC. Comparison of dried-coated (SEM) and wet-fixed (AFM) fenestrae indicated a mean shrinkage of 20% in SEM preparations. In conclusion, high-resolution imaging with AFM of the cell surface of cultured LEC can be performed on dried-coated, dried-uncoated and wet-fixed LEC, which was hitherto only possible with fixed, dried and coated preparations in SEM and transmission electron microscopy (TEM).  相似文献   

14.
A method is introduced to assess and correct the geometric distortions which frequently occur in low-magnification scanning electron microscopy (SEM) images. Such images typically exhibit a complex pattern of varying deviations from orthogonality which cannot be adequately corrected by simple geometric transformations such as shifting, scaling, rotation, or shearing. A suitable approach to rectify low-magnification SEM images is polynomial warping, a correction procedure which also accomplishes rubber sheet transformation. To demonstrate the approach, a reference grid for low magnifications has been scanned at 40- and 55-fold magnifications by means of a microanalyzer. Calculated geometric distortions range from 1.5 to 3.5% of the image dimensions; applying polynomial warping, distortions could be reduced to approximately 0.1% of the image dimensions. Because of its easy application and the widespread availability in image processing packages, polynomial warping can be recommended as a routine procedure for rectifying low-magnification SEM images.  相似文献   

15.
A comparative study of atomic force microscopy (AFM) and scanning electron microscopy (SEM) imaging of the healthy human liver parenchyma was carried out to determine the similarities and the differences. In this study, we compared the fine hepatic structures as observed by SEM and AFM. Although AFM revealed such typical hepatic structures as bile canaliculi and hepatocytes, it also showed the location of the nucleus and chromatin granules in rough relief structure, which was not visible by SEM. By contrast, SEM visualized other structures, such as microvilli, the central vein, and collagenous fibers, none of which was visualized by AFM. For better orientation and confirmation of most of the structures imaged by SEM and AFM, Congo Red-stained specimens were also examined. Amyloid deposits in the Disse's spaces were shown especially clearly in these images. The differences between the SEM and AFM images reflected the characteristics of the detection systems and methods used for sample preparation. Our results reveal that more detailed information on hepatic morphology is obtained by exploiting the advantages of both SEM and AFM.  相似文献   

16.
Oho E 《Scanning》2004,26(3):140-146
Complex hysteresis smoothing (CHS), which was developed for noise removal of scanning electron microscopy (SEM) images some years ago, is utilized in acquisition of an SEM image. When using CHS together, recording time can be reduced without problems by about one-third under the condition of SEM signal with a comparatively high signal-to-noise ratio (SNR). We do not recognize artificiality in a CHS-filtered image, because it has some advantages, that is, no degradation of resolution, only one easily chosen processing parameter (this parameter can be fixed and used in this study), and no processing artifacts. This originates in the fact that its criterion for distinguishing noise depends simply on the amplitude of the SEM signal. The automation of reduction in acquisition time is not difficult, because CHS successfully works for almost all varieties of SEM images with a fairly high SNR.  相似文献   

17.
This paper describes the use of sputter coating to prepare detergent-extracted cytoskeletons for observation by scanning (SEM), scanning transmission (STEM), inverted contrast STEM, and transmission (TEM) electron microscopy. Sputtered coats of 1–2 nm of platinum or tungsten provide both an adequate secondary electron signal for SEM and good contrast for STEM and TEM. At the same time, the grain size of the coating is sufficiently fine to be just at (platinum) or below (tungsten) the limit of resolution for SEM and STEM. In TEM, the granular structure of platinum coats is resolved, and platinum decoration artifacts are observed on the surface of structures. The platinum is deposited as small islands with a periodic distribution that may reveal information about the underlying molecular structure. This method produces samples that are similar in appearance to replicas prepared by low-angle rotary shadowing with platinum and carbon. However, the sputter-coating method is easier to use; more widely available to investigators; and compatible with SEM, STEM, and TEM. It may also be combined with immunogold and other labeling methods. While TEM provides the highest resolution images of sputter-coated cytoskeletons, it also damages the specimens owing to heating in the beam. In SEM and STEM cytoskeletons are stable and the resolution is adequate to resolve individual microfilaments. The best single method for visualizing cytoskeletons is inverted contrast STEM, which images both the metal-coated cytoskeletal structures and electron-dense material within the nucleus and cytoplasm as white against a dark background. STEM and TEM were both suitable for visualizing colloidal gold particles in immunolabeled samples.  相似文献   

18.
In conventional scanning electron microscopy (SEM), the lateral resolution is limited by the electron beam diameter impinging on the specimen surface. Near field emission scanning electron microscopy (NFESEM) provides a simple means of overcoming this limit; however, the most suitable field emitter remains to be determined. NFESEM has been used in this work to investigate the W (1 1 0) surface with single-crystal tungsten tips of (3 1 0), (1 1 1), and (1 0 0)-orientations. The topographic images generated from both the electron intensity variations and the field emission current indicate higher resolution capabilities with decreasing tip work function than with polycrystalline tungsten tips. The confinement of the electron beam transcends the resolution limitations of the geometrical models, which are determined by the minimum beam width.  相似文献   

19.
Contrast plays a crucial role both in qualitative and quantitative imaging in scanning microscopy. Usual methods of obtaining high contrast images in the scanning electron microscope (SEM) involve performing specific operations on the video signal already produced by the SEM. In this article, the concept of in situ differential imaging in the SEM is discussed. In this imaging modality, a true differential image of the sample is generated simultaneously with the normal video. The signal can be obtained at low and high video band-widths, thus allowing low contrast objects to be readily imaged. Various methodologies developed to perform in situ differential imaging are reviewed. A characteristic of all these techniques is their sensitivity to edges, a feature which is extensively used in a number of applications. The ability to obtain feature enhancement in any desired direction is another important attribute of this approach. Examples are given on the use of the method in general imaging as well as in the metrology of critical dimensions.  相似文献   

20.
A method of direct visualization by correlative scanning electron microscopy (SEM) and fluorescence light microscopy of cell structures of tissue cultured cells grown on conductive glass slides is described. We show that by growing cells on indium–tin oxide (ITO)-coated glass slides, secondary electron (SE) and backscatter electron (BSE) images of uncoated cells can be obtained in high-vacuum SEM without charging artefacts. Interestingly, we observed that BSE imaging is influenced by both accelerating voltage and ITO coating thickness. By combining SE and BSE imaging with fluorescence light microscopy imaging, we were able to reveal detailed features of actin cytoskeletal and mitochondrial structures in mouse embryonic fibroblasts. We propose that the application of ITO glass as a substrate for cell culture can easily be extended and offers new opportunities for correlative light and electron microscopy studies of adherently growing cells.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号