首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 437 毫秒
1.
The thermal performances of solar collectors and solar combi systems with different solar fractions are studied under the influence of the Danish design reference year, DRY data file, and measured weather data from a solar radiation measurement station situated at the Technical University of Denmark in Kgs. Lyngby. The data from DRY data file are used for any location in Denmark. The thermal performances of the solar heating systems are calculated by means of validated computer models. The measured yearly solar radiation varies by approximately 23% in the period from 1990 until 2002, and the investigations show that it is not possible to predict the yearly solar radiation on a tilted surface based on the yearly global radiation.The annual thermal performance of solar combi systems cannot with reasonable approximation be fitted to a linear function of the annual total radiation on the solar collector or the annual global radiation. Solar combi systems with high efficient solar collectors are more influenced by weather variations from one year to another than systems with low efficient solar collectors.The annual thermal performance of solar collectors cannot be predicted from the global radiation, but both the annual thermal performance and the annual utilized solar energy can with a reasonable approximation be fitted to a linear function of the yearly solar radiation on the collector for both flat plate and evacuated tubular solar collectors. Also evacuated tubular solar collectors utilize less sunny years with large parts of diffuse radiation relatively better than flat plate collectors.  相似文献   

2.
Analytical models have been put forward to predict the thermal performance of passive heating systems, which have previously been suggested. The systems consist of a water vessel for heat storage and a structure positioned on its outside wall, which act as a solar collector and a thermal insulation for the storage, respectively. Four different variations of structures have been considered and numerical calculations performed corresponding to the physical parameters of an earlier reported experimental study. The analysis is able to predict the experimental results fairly satisfactorily.  相似文献   

3.
This paper uses the F-chart technique to evaluate three types of solar heating systems, namely; space solar heating and domestic hot water system (SHDHW), domestic hot water system (DHW) and solar swimming pool heating system (SPHS), using three types of concrete solar collectors, models A, B, and C, and one conventional metallic solar collector.

The economical analysis of SHDHW system revealed that the concrete collectors provided about 49 and 63% of the annual load when the collecting area of the solar panel increased from 55 to 88 M2 (25 to 40% of the building roof area). The corresponding solar contributions when conventional metallic collectors were used are 41 and 53%, respectively. This represents an improvement of the annual solar fraction of about 19% when concrete collectors are used instead of the metallic collectors.

It was found that solar heating systems with concrete solar collector models gave higher solar fractions and total life cycle savings than the conventional solar metallic collector.  相似文献   


4.
The energy saving obtainable with active solar heating and heat pumps has been studied for several years in the Northern climate of Finland. The studies deal mainly with small houses. A computer program is developed which calculates hour by hour the annual energy balance of different heating systems. The performance, of the heating systems are also measured in inhabited houses. The calculations show that the useful solar energy obtainable from the collector is 50–400 kWh/m2 annually depending on the system and the collector size. A heat pump in the system is very advantageous, because it keeps the heat losses low and the collector efficiency high. It approximately doubles the energy obtainable. The measurement results have not been as good as expected. The solar energy obtained from the collector has been 120–160 kWh/m2 annually. The main reasons for the low solar energy are design and equipment faults and the shading effects. The best energy saving device is the earth heat pump. It is also therefore very advantageous that the peak power demand decreases markedly. When the area of the earth pipes is large enough, energy may be extracted from earth through the whole year. The annual coefficient of performance is 2–3. Also a heat pump which extracts heat from exhaust air in dwelling houses has been very promising.  相似文献   

5.
The Solar Energy Research Group in the Universiti Kebangsaan Malaysia has been set-up more than two decades ago. One of the activities is in the field of solar thermal process, particularly in development of solar assisted drying systems. Solar drying systems technical development can proceed in two directions. Firstly simple, low power, short life, and comparatively low efficiency-drying system. Secondly, the development of high efficiency, high power, long life expensive solar drying system. The group has developed four solar assisted drying systems namely (a) the V-groove solar collector, (b) the double-pass solar collector with integrated storage system, (c) the solar assisted dehumidification system for medicinal herbs and (d) the photovoltaic thermal (PVT) collector system. The common problems associated with the intermittent nature of solar radiation and the low intensities of solar radiation in solar thermal systems can be remedied using these types of solar drying systems. These drying systems have the advantages of heat storage, auxiliary energy source, integrated structure control system and can be use for a wide range of agricultural produce.  相似文献   

6.
Global and diffuse solar radiation intensities are, in general, measured on horizontal surfaces, whereas stationary solar conversion systems (both flat plate solar collector and PV) are tilted towards the sun in order to maximize the amount of solar radiation incident on the collector surface. Consequently, the solar radiation incident on a tilted surface must be determined by converting the solar radiation intensities measured on a horizontal surface to that incident on the tilted surface of interest. There exist a large number of models designed to perform such a conversion. 11 such models have been tested utilizing data measured in Beer Sheva, Israel. The data consist of hourly global and diffuse solar radiation on a horizontal surface, normal incidence beam and global radiation on a south-oriented surface tilted at 40°. The horizontal diffuse radiation measured using a shadow ring was corrected using four different correction models. This resulted in 44 model permutations. The individual model performance is assessed by an inter-comparison between the calculated and measured solar global radiation on the south-oriented surface tilted at 40° using both graphical and statistical methods. The relative performance of the different models under different sky conditions has been studied. Different grading systems have been applied in an attempt to score the relative performance of the models.  相似文献   

7.
In this paper, a techno-economic model has been developed for a hybrid solar forced-convection water heating system. Two options of auxiliary energy use, viz. (A) an instant electric heater and (B) use of diesel as the auxiliary energy fuel, have been considered. Numerical calculations have been made for the climate of Delhi, India, corresponding to the two representative demand patterns, viz. (i) hot-water demand of big residential buildings and (ii) industrial hot-water demand. Taking into account the life, capital cost and the maintenance cost of the solar and auxiliary systems, the cost of useful energy has been calculated for different values of collector area and tank capacity. This exercise, thereby, yields the optimum values of collector area and tank capacity corresponding to the minimum cost of useful energy. The effect of government subsidy on the optimized values of collector area, tank capacity and cost of useful energy has also been investigated.  相似文献   

8.
Energy savings for solar heating systems   总被引:1,自引:0,他引:1  
In this paper the realistic behaviour and efficiency of heating systems were analysed, based on long term monitoring projects. Based on the measurements a boiler model used to calculate the boiler efficiency on a monthly basis was evaluated. Comparisons of measured and calculated fuel consumptions showed a good degree of similarity. With the boiler model, various simulations of solar domestic hot water heating systems were done for different hot water demands and collector sizes. The result shows that the potential of fuel reduction can be much higher than the solar gain of the solar thermal system. For some conditions the fuel reduction can be up to the double of the solar gain due to a strong increase of the system efficiency. As the monitored boilers were not older than 3 years, it can be assumed that the saving potential with older boilers could be even higher than calculated in this paper.  相似文献   

9.
In this paper, a methodology is proposed to determine the design space for synthesis, analysis, and optimization of solar water heating systems. The proposed methodology incorporates different design constraints to identify all possible designs or a design space on a collector area vs. storage volume diagram. The design space is represented by tracing constant solar fraction lines on a collector area vs. storage volume diagram. It has been observed that there exists a minimum as well as a maximum storage volume for a given solar fraction and collector area. Similarly existence of a minimum and a maximum collector area is also observed for a fixed solar fraction and storage volume. For multi-objective optimization, a Pareto optimal region is also identified. Based on the identified design space, the solar water heating system is optimized by minimizing annual life cycle cost. Due to uncertainty in solar insolation, system parameters and cost data, global optimization may not be utilized to represent a meaningful design. To overcome this, a region of possible design configurations is also identified in this paper.  相似文献   

10.
Multilayer fabric stratification pipes for solar tanks   总被引:1,自引:0,他引:1  
The thermal performance of solar heating systems is strongly influenced by the thermal stratification in the heat storage. The higher the degree of thermal stratification is, the higher the thermal performance of the solar heating systems. Thermal stratification in water storage can for instance be achieved by use of inlet stratifiers combined with low flow operation in the solar collector loop. In this paper, investigation of a number of different fabric stratification pipes is presented and compared to a non-flexible inlet stratifier. Additional, detailed investigation of the flow structure close to two fabric stratification pipes is presented for one set of operating conditions by means of the optical PIV (Particle Image Velocimetry) method.  相似文献   

11.
S.S. Chandel  R.K. Aggarwal   《Renewable Energy》2008,33(10):2166-2173
Under the Passive Solar Building Programme, more than 100 buildings have been constructed in the high altitude region of the Indian State of Himachal Pradesh. A policy decision has been taken by the State that all government/semi-government buildings are to be designed and constructed as per passive solar housing technology. The evaluation studies of some of these buildings have been carried out by our group. In the present study, the thermal performance of a passive solar bank building at Shimla, has been evaluated. This solar building incorporates a heat-collecting wall and a roof-top solar air heater with an electric heating backup, sunspaces and double-glazed windows. The monitoring of the building shows that the solar passive features in the building results in comfortable living conditions. The study shows that the high cost central electric/gas/wood-fired heating systems can be replaced by a low cost solar heating system with backup heaters. This will result not only in reducing higher installation costs of these systems but also the annual running and maintenance costs. It is shown that the solar passive features save electricity required for space heating and reduce the heat losses in the building by about 35%. The strategy to be followed for the propagation of passive solar technology on large scale in this Himalayan State or in any other cold hilly region is also presented.  相似文献   

12.
This investigation reports a new type of solar water heating system without water pipes on the collector surface or a separate storage tank. The water to be heated continuously flows perpendicularly from an upper transparent cover to a porous absorber and is stored in a small volume beneath this assembly. Three different systems were designed, manufactured and tested but only one proved to be successful; this design indicated higher thermal efficiency compared to conventional collectors at high flow rates whereas at low flow rates the opposite is true.  相似文献   

13.
A general chart is developed for calculating the collector area required to provide a prescribed value of the annual load fraction for solar heating systems. The relationship between collector area and annual load fraction can then be easily obtained for specified collector design parameters, load and location. The construction of the chart is based on correlating data generated by the f-chart method. Data of 13 locations in the U.S.A. are considered. The good agreement of the results obtained by the present simple method and the f-chart for both space and combined space/domestic water heating proves that the two methods are almost of the same accuracy. Since the present chart is not location dependent and allows direct comparison of different collectors, it is a very valuable design aid for sizing and selecting solar collectors.  相似文献   

14.
Solar water heating systems are widely used in Brazil for domestic purposes in single-family households. The exploitation of the potential energy of the water from the upper tank and the thermosyphon phenomena for hot water circulation constitutes the absolute majority of the residential solar water heating systems in the country. But, these water heating systems are usually sized according to tables provided by the manufacturers, which show the number of plates required based on the size of the family and the number of hot water outlets. This sizing is based much more on intuition rather than on scientific data. For that reason, this work has developed an optimization model for water heating systems design parameters, using a numerical simulation routine, in a long-term transient regime. The optimized design gives the slope and area of the flat plate collector, which results in the minimum cost over the equipment life cycle. The computing procedure was executed considering specific characteristics of the project. A thermosyphon solar water heating system with flat-plate collector for Sao Paulo's climate was simulated. The practice of Brazilian designers and manufacturers is to recommend the maximization of the energetic gain for the winter. This paper has analyzed in economic terms if it is more attractive to increase the gain of solar energy in the winter period, with the consequence of reduction of the solar energy gain along the year, or to adopt the adequate slope, which improves the yearly solar energy gain.  相似文献   

15.
Growing global concern regarding climate change motivates technological studies to minimize environmental impacts. In this context, solar water heating (SWH) systems are notably prominent in Brazil, primarily because of the abundance of solar energy in the country. However, SWH designs have not always been perfectly developed. In most projects, the installation option of the solar system only considers the electric power economy aspects and not the particular characteristics of each climatic zone. Thus, the primary objective of this paper is to assess the potential of carbon dioxide reduction with the use of SWH in comparison with electric showers in social housing in several Brazilian climatic zones. The Brazilian government authorities have created public policies to encourage the use of these technologies primarily among the low-income population. The results of this paper indicate that hot climactic regions demonstrate a low reduction of CO2 emissions with SWH installations. Thus, solar radiation is not useful for water heating in those regions, but it does lead to a large fraction of household cooling loads, implying a demand for electrical energy for air conditioning or requiring the adoption of passive techniques to maintain indoor temperatures below threshold values.  相似文献   

16.
German central solar heating plants with seasonal heat storage   总被引:4,自引:0,他引:4  
Central solar heating plants contribute to the reduction of CO2-emissions and global warming. The combination of central solar heating plants with seasonal heat storage enables high solar fractions of 50% and more. Several pilot central solar heating plants with seasonal heat storage (CSHPSS) built in Germany since 1996 have proven the appropriate operation of these systems and confirmed the high solar fractions.Four different types of seasonal thermal energy stores have been developed, tested and monitored under realistic operation conditions: Hot-water thermal energy store (e.g. in Friedrichshafen), gravel-water thermal energy store (e.g. in Steinfurt-Borghorst), borehole thermal energy store (in Neckarsulm) and aquifer thermal energy store (in Rostock). In this paper, measured heat balances of several German CSHPSS are presented. The different types of thermal energy stores and the affiliated central solar heating plants and district heating systems are described. Their operational characteristics are compared using measured data gained from an extensive monitoring program. Thus long-term operational experiences such as the influence of net return temperatures are shown.  相似文献   

17.
Suleyman Karsli   《Renewable Energy》2007,32(10):1645-1660
This paper presents a performance analysis of four types of air heating flat plate solar collectors: a finned collector with an angle of 75°, a finned collector with an angle of 70°, a collector with tubes, and a base collector. In this study, the first and second laws of efficiencies were determined for the collectors and comparisons were made among them. The results showed that the efficiency depends on the solar radiation and the construction of the solar air collectors. The temperature rise varied almost linearly with the incident radiation. The first law of efficiency changed between 26% and 80% for collector-I, between 26% and 42% for collector-II, between 70% and 60% for collector-III, and between 26% and 64% for collector-IV. The values of second law efficiency varied from 0.27 to 0.64 for all collectors? The highest collector efficiency and air temperature rise were achieved by the finned collector with angle of 75°, whereas the lowest values were obtained for the base collector. The effectiveness order of the collectors was determined as the finned collector with angle of 75°, the finned collector with angle of 70°, the collector with tubes, and the base collector.  相似文献   

18.
C. Coskun  Z. Oktay 《Energy》2011,36(2):1319-1323
The concept of probability density frequency, which is successfully used for analyses of wind speed and outdoor temperature distributions, is now modified and proposed for estimating solar radiation distributions for design and analysis of solar energy systems. In this study, global solar radiation distribution is comprehensively analyzed for photovoltaic (PV) panel and thermal collector systems. In this regard, a case study is conducted with actual global solar irradiation data of the last 15 years recorded by the Turkish State Meteorological Service. It is found that intensity of global solar irradiance greatly affects energy and exergy efficiencies and hence the performance of collectors.  相似文献   

19.
In this study, experiments were performed to find out how the thermal performance of a two-phase thermosyphon solar collector was affected by using different refrigerants. Three identical small-scale solar water heating systems, using refrigerants R-134a, R407C, and R410A, were constructed and tested side-by-side under various environmental and load conditions. The performance of the system under clear-sky conditions has been investigated with and without water load. Detailed temperature distributions and cumulative collection efficiencies were determined and presented. The experimental results were compared to the results found in the literature and they showed good agreement.  相似文献   

20.
Buildings represent nearly 40 percent of total energy use in the U.S. and about 50 percent of this energy is used for heating, ventilating, and cooling the space. Conventional heating and cooling systems are having a great impact on security of energy supply and greenhouse gas emissions. Unlike conventional approach, this paper investigates an innovative passive air conditioning system coupling earth-to-air heat exchangers (EAHEs) with solar collector enhanced solar chimneys. By simultaneously utilizing geothermal and solar energy, the system can achieve great energy savings within the building sector and reduce the peak electrical demand in the summer. Experiments were conducted in a test facility in summer to evaluate the performance of such a system. During the test period, the solar chimney drove up to 0.28 m3/s (1000 m3/h) outdoor air into the space. The EAHE provided a maximum 3308 W total cooling capacity during the day time. As a 100 percent outdoor air system, the coupled system maximum cooling capacity was 2582 W that almost covered the building design cooling load. The cooling capacities reached their peak during the day time when the solar radiation intensity was strong. The results show that the coupled system can maintain the indoor thermal environmental comfort conditions at a favorable range that complies with ASHRAE standard for thermal comfort. The findings in this research provide the foundation for design and application of the coupled system.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号