首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An experiment was performed to simulate a water cooling panel system for decay heat removal from a high-temperature gas-cooled reactor (HTGR) and to investigate the performance of decay heat removal and the temperature distribution for components of the system. The experimental apparatus is composed of a pressure vessel 1 m in diameter and 3 m in height, containing heaters with a maximum heating rate of 100 kW which simulates the decay heat of the reactor core and cooling panels surrounding the pressure vessel. The analytical code THANPACST2 was applied to analyze the experimental data and to investigate the validity of the analytical method and model proposed. Under conditions using helium gas at a pressure of 0.73 MPa and temperature of 210°C in the pressure vessel, temperatures of the pressure vessel were well estimated to within differences of −29 to +37°C compared to the experimental data. The analyses indicate that the heat removed by the cooling panel is 11.4% less than the experimental value and the heat transferred by thermal radiation is 74.4% of the total heating value. It was also found that the lower head of the pressure vessel is effectively cooled by natural convection through the flow channels at the upper and the lower edges of the skirt-type support of the pressure vessel. © 1998 Scripta Technica, Heat Trans Jpn Res, 26(3): 159–175, 1997  相似文献   

2.
Simplified analytical models are developed for evaluating the thermal performance of closed‐wet cooling towers (CWCTs) for use with chilled ceilings in cooling of buildings. Two methods of simplification are used with regard to the temperature of spray water inside the tower. The results obtained from these models for a prototype cooling tower are very close to experimental measurements. The thermal performance of the cooling tower is evaluated under nominal conditions. The results show that the maximum difference in the calculated cooling water heat or air sensible heat between the two simplified methods and a general computational model is less than 3%. The analytical model distribution of the sensible heat along the tower is then incorporated with computational fluid dynamics (CFD) to assess the thermal performance of the tower. It is found that CFD results agree well with the analytical results when the air flow is simulated with air supply from the bottom of the tower, which represents a uniform air flow. CFD shows the importance of the uniform distribution of air and spray water to achieve optimum design. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

3.
In high concentrating photovoltaic systems, thermal regulation is of great importance to the conversion efficiency and the safety of solar cells. Direct‐contact liquid film cooling technique is an effective way of thermal regulation with low initial investment. Tilt of solar cells is common in concentrating solar systems. An evaluation of direct‐contact liquid film cooling technique behind tilted high concentration photovoltaics was performed using both experimental and computational approaches. In the experiment, deionized water was used as the coolant at the back of simulated solar cells. Solar cell inclination of 0° to 75° with inlet water flow rate of 100–300 L/hour and inlet temperature of 30°C to 75°C were experimentally investigated. A two‐dimensional model was developed using computational fluid dynamics technique and validated by experimental results. The effects of inclination on average temperature, temperature uniformity, and heat transfer coefficient were discovered in this paper. The results indicated that 20° is the optimum angle for liquid film cooling. In addition, optimum inlet width, temperature, and velocity for inclination over 30° are 0.75 mm, 75°C, and 0.855 m/s, respectively.  相似文献   

4.
The performance optimization of an endoreversible air refrigerator with variable‐temperature heat reservoirs is carried out by taking the cooling load density, i.e. the ratio of cooling load density to the maximum specific volume in the cycle, as the optimization objective in this paper. The analytical relations of cooling load, cooling load density and coefficient of performance are derived with the heat resistance losses in the hot‐ and cold‐side heat exchangers. The maximum cooling load density optimization is performed by searching the optimum pressure ratio of the compressor, the optimum distribution of heat conductance of the hot‐ and cold‐side heat exchangers for the fixed total heat exchanger inventory, and the heat capacity rate matching between the working fluid and the heat reservoirs. The influences of some design parameters, including the heat capacitance rate of the working fluid, the inlet temperature ratio of heat reservoirs and the total heat exchanger inventory on the maximum cooling load density, the optimum heat conductance distribution, the optimum pressure ratio and the heat capacity rate matching between the working fluid and the heat reservoirs are provided by numerical examples. The refrigeration plant design with optimization leads to a smaller size including the compressor, expander and the hot‐ and cold‐side heat exchangers. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

5.
With temperature increasing, the photovoltaic efficiency of solar cells is reduced significantly. Such an efficiency loss may offset the efficiency improvement because of the development of the photovoltaic technology. This paper provides a novel approach for efficiency loss recovery of solar cells. Specifically, a nano‐coated heat pipe plate was integrated with the solar panel to remove heat from the hotspots on solar cells. This study concerns the indoor experiments of a commercial solar cell thermally managed with a heat pipe plate. The temperature rise and non‐uniformity on the solar panel were quantified in different light irradiances. With thermal management by the heat pipe plate, the solar panel shows a temperature‐rise reduction of 47–50%. This implies that half of the efficiency loss of the solar cell can be recovered. In addition, the temperature variation within the solar panel is reduced to 1.0–2.5 °C, which is beneficial in prolonging the longevity of the solar cell. In the experiments, the heat pipe plate can provide a cooling flux of 380 W/m2 with light irradiance below 1000 W/m2. By incorporating the heat pipe plate with a water jacket, the heat removal flux could be improved to 600 W/m2, leading to a solar cell temperature of a few degrees higher than the ambient. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

6.
In this study, superheating and sub‐cooling heat exchangers in vapor‐compressed refrigeration system are analyzed from thermodynamics and economical (refrigeration system operation cost, investment cost) viewpoints. Using four different refrigerants (R22, R502, R134a and R404a), the temperature of condenser at the interval of (35–55°C) and temperature of evaporator at the interval of (?10 to 10°C) have been obtained from the calculation process. The second law analysis (analysis of irreversibility) of a refrigeration system is carried out and then the whole system is optimized thermo‐economically. As a result of calculations, optimum superheating and sub‐cooling temperatures of heat exchanger (superheating, sub‐cooling) areas corresponding to these temperatures are obtained. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

7.
A multieffect refrigeration system that is based on a waste‐heat‐driven organic Rankine cycle that could produce refrigeration output of different magnitudes at different levels of temperature is presented. The proposed system is integration of combined ejector–absorption refrigeration cycle and ejector expansion Joule–Thomson (EJT) cooling cycle that can meet the requirements of air‐conditioning, refrigeration, and cryogenic cooling simultaneously at the expense of industrial waste heat. The variation of the parameters that affect the system performance such as industrial waste heat temperature, refrigerant turbine inlet pressure, and the evaporator temperature of ejector refrigeration cycle (ERC) and EJT cycles was examined, respectively. It was found that refrigeration output and thermal efficiency of the multieffect cycle decrease considerably with the increase in industrial waste heat temperature, while its exergy efficiency varies marginally. A thermal efficiency value of 22.5% and exergy efficiency value of 8.6% were obtained at an industrial waste heat temperature of 210°C, a turbine inlet pressure of 1.3 MPa, and ejector evaporator temperature of 268 K. Both refrigeration output and thermal efficiency increase with the increase in turbine inlet pressure and ERC evaporator temperature. Change in EJT cycle evaporator temperature shows a little impact on both thermal and exergy efficiency values of the multieffect cycle. Analysis of the results clearly shows that the proposed cycle has an effective potential for cooling production through exploitation of lost energy from the industry. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

8.
The paper deals with a passive air‐based cooling technique of photovoltaic (PV) panels in operating conditions. Cooling technique is done by specific type of using aluminium fins, and its main purpose is to increase the electrical efficiency of the PV panel. An increase in electrical efficiency can be achieved because of temperature degradation effect, where the PV panel yields less power at higher operating temperatures (the PV panel's efficiency can drop by up to 0.5%/°C). To confirm a cooling technique, a medium‐sized PV system was used in a 2‐month experiment. The experiment was done in realistic operating conditions, and all working parameters were thoroughly measured. After the analysis of the data, no significant raise in electrical efficiency was recorded throughout the experiment. A numerical approach was conducted, based on gained experimental data. Developed numerical model gave explanations of experimental results and provided an insight in heat flow through the PV cell. Later on, developed numerical model was used to propose new cooling variations of the fin‐based technique and to further examine the overall potential of air based passive cooling techniques. It was shown that cooling effect by up to 5°C is a realistic expectation for this technique in described operating conditions.  相似文献   

9.
A segmented approach [1] for the CO2 helical‐coil‐in‐fluted‐tube gas cooler is developed. The CO2 helical‐coil‐in‐fluted‐tube gas cooler consists of helically coiled tube and fluted tube. It is fabricated by twisting a straight copper tube to form helically coiled tube and embedded in the groove of the fluted tube. The available heat transfer and pressure drop correlations for the supercritical CO2‐side and water‐side are provided to simulate the gas cooler. The simulation is compared with a detailed set of experimental data, for given the inlet conditions. The predicted data matches well with the experimental data with absolute average deviations of 1.15, 4.6 and 4.7% for the CO2 pressure drop, gas cooler exit temperature and hot water temperature, respectively. Based on the good matches between measured data and predicted data, the detailed thermodynamic processes of gas cooler parameters are predicted and analyzed. Furthermore, different arrangements of the gas cooler within the original package dimensions are simulated and better performance of the gas cooler is obtained under the structural parameters of the 3‐row fluted tube with the inner diameter 12 mm. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

10.
This paper presents a computational study of an energy‐efficient technique for post‐combustion CO2 capture using novel material, namely, Mg‐MOF‐74, using pressure swing adsorption (PSA) processes. A detailed one‐dimensional, transient mathematical model has been formulated to include the heat and mass transfer, the pressure drop and multicomponent mass diffusion. The PSA model has been further extended by incorporating a heat regenerating process to enhance CO2 sequestration. The heat dissipated during adsorption is stored in packed sand bed and released during desorption step for heating purpose. The model has been implemented on a MATLAB program using second‐order discretization. Validation of the model was performed using a complete experimental data set for CO2 sequestration using zeolite 13X. Simulation of the PSA experiment on fixed bed has been carried out to evaluate the capacity of Mg‐MOF‐74 for CO2 capture with varying feed gas temperature of 28 and 100 °C, varying pressurization and purge times and heat regeneration. It was discovered that the PSA process with heat regeneration system might be advantageous because it achieves equivalent amount of CO2 sequestration in fewer PSA cycles compared with PSA without heat regeneration system. Based on the simulated conditions, CO2 recovery with Mg‐MOF‐74 gives high percentage purity (above 98%) for the captured CO2. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

11.
An analytical solution of the transient temperature response in a semi‐infinite medium with a line source of finite length has been derived, which is a more appropriate model for boreholes in geothermal heat exchangers, especially for their long‐duration operation. The steady‐state temperature distribution has also been obtained as a limit of this solution. An erratic approach to this problem that appears in some handbooks and textbooks is indicated. Two representative steady‐state borehole wall temperatures, the middle point temperature and the integral mean temperature, are defined. Differences between them are compared, and concise expressions for both are presented for engineering applications. On this basis the influence of the annual imbalance between heating and cooling loads of the geothermal heat exchangers is discussed regarding their long‐term performance. © 2002 Wiley Periodicals, Inc. Heat Trans Asian Res, 31(7): 558–567, 2002; Published online in Wiley InterScience ( www.interscience.wiley.com ). DOI 10.1002/htj.10057  相似文献   

12.
This study summarizes the cooling performance of a ground‐source heat pump system which was installed in a 65‐m2 room in the Solar Energy Institute, Ege University, Izmir (568 degree‐days cooling, base: 22°C; 1226 degree‐days heating, base: 18°C) Turkey. The institute, built in 1986, has a liveable floor area of 3000 m2, and uses passive solar techniques. The heating and cooling loads of the room were, respectively, 3.8 and 4.2 kW at design conditions. The system was commissioned in May 2000 and the performance tests have been carried out since then. Based upon the measurements, the heat rejection rate to the soil with an average thermal diffusivity of 0.00375 m2h?1 in the cooling mode was found to be in average 51 W m?1 of bore depth, while the maximum entering water temperature to the unit was recorded as 35.9°C. The cooling coefficient of performance of the heat pump and the whole system was relatively low when compared to other heat pumps operating under conditions at or near design values. The primary reasons for this were discussed in detail and the potential for performance improvements was also suggested. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

13.
The present study considers a thermodynamic analysis and performance optimization of geothermal power cycles. The proposed binary‐cycles operate with moderately low temperature and liquid‐dominated geothermal resources in the range of 110°C to 160°C, and cooling air at ambient conditions of 25°C and 101.3 kPa reference temperature and atmospheric pressure, respectively. A thermodynamic optimization process and an irreversibility analysis were performed to maximize the power output while minimizing the overall exergy destruction and improving the First‐law and Second‐law efficiencies of the cycle. Maximum net power output was observed to increase exponentially with the geothermal resource temperature to yield 16–49 kW per unit mass flow rate of the geothermal fluid for the non‐regenerative organic Rankine cycles (ORCs), as compared with 8–34 kW for the regenerative cycles. The cycle First‐law efficiency was determined in the range of 8–15% for the investigated geothermal binary power cycles. Maximum Second‐law efficiency of approximately 56% was achieved by the ORC with an internal heat exchanger. In addition, a performance analysis of selected pure organic fluids such as R123, R152a, isobutane and n‐pentane, with boiling points in the range of ?24°C to 36°C, was conducted under saturation temperature and subcritical pressure operating conditions of the turbine. Organic fluids with higher boiling point temperature, such as n‐pentane, were recommended for non‐regenerative cycles. The regenerative ORCs, however, require organic fluids with lower vapour specific heat capacity (i.e. isobutane) for an optimal operation of the binary‐cycle. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

14.
The thermal performance of a chemical heat pump that uses the reaction system of calcium oxide/lead oxide/carbon dioxide, which is developed for utilization of high‐temperature heat above 800°C, is studied experimentally. The thermal performance of a packed‐bed reactor of a calcium oxide/carbon dioxide reaction system, which stores and transforms a high‐temperature heat source in the heat pump operation, is examined under various heat pump operation conditions. The energy analysis based on the experiment shows that it is possible to utilize high‐temperature heat with this heat pump. This heat pump can store heat above 850°C and then transform it into a heat above 900°C under an approximate atmospheric pressure. An applied system that combines the heat pump and a high‐temperature process is proposed for high‐efficiency heat utilization. The scale of the heat pump in the combined system is estimated from the experimental results. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

15.
The main objective of the present study is to investigate the performance characteristics of a solar‐assisted ground‐source heat pump system (SAGSHPS) for greenhouse heating with a 50 m vertical 1¼ in nominal diameter U‐bend ground heat exchanger. This system was designed and installed in the Solar Energy Institute, Ege University, Izmir (568 degree days cooling, base: 22°C, 1226 degree days heating, base: 18°C), Turkey. Based upon the measurements made in the heating mode, the heat extraction rate from the soil is found to be, on average, 54.08 Wm?1 of bore depth, while the required borehole length in meter per kW of heating capacity is obtained as 12.57. The entering water temperature to the unit ranges from 8.2 to 16.2°C, with an average value of 9.1°C. The greenhouse air is at a maximum day temperature of 25°C and night temperature of 14°C with a relative humidity of 40%. The heating coefficient of performance of the heat pump (COPHP) is about 2.13 at the end of a cloudy day, while it is about 2.84 at the end of sunny day and fluctuates between these values in other times. The COP values for the whole system are also obtained to be 5–15% lower than COPHP. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

16.
A three‐effect heat pipe (heat pipe heating, heat pipe cooling and heat pipe heat recovery) adsorption refrigeration system using compound adsorbent (calcium chloride and activated carbon) was designed. The dynamic characteristics of mass and heat pipe heat recovery were studied. The results show that mass recovery and heat pipe heat recovery can improve (specific cooling power) SCP and (coefficient of performance) COP greatly. The averaged SCP of the cycle with mass recovery and the cycle without mass recovery is 502.9 W/kg and 436.7 W/kg at about 30 °C of cooling water temperature and ?15 °C of evaporating temperature. The corresponding COP is 0.27 and 0.24 respectively. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

17.
Based on “wall‐adjacent layer” effect, the convective heat transfer for developed laminar flow of gas through parallel‐plate microchannel with one wall temperature constant and the other adiabatic was analyzed theoretically. Considering the change in thermal conductivity and viscosity of gas in the region adjacent to the solid wall, mathematical models were built and the dimensionless temperature distribution and the corresponding heat transfer characteristics were simulated numerically. The results indicate that the laminar heat transfer coefficient is less than that of the larger passages, while the dimensionless temperature is greater than that of the larger passages. Compared with the monotonous boundary conditions, the varied heat transfer coefficient amplitude of mixed boundary condition is lower. © 2002 Wiley Periodicals, Inc. Heat Trans Asian Res, 32(1): 58–64, 2003; Published online in Wiley InterScience ( www.interscience.wiley.com ). DOI 10.1002/htj.10075  相似文献   

18.
The heat transfer characteristics and flow behavior in a rectangular passage with two opposite 45° skewed ribs for turbine rotor blade have been investigated for Reynolds numbers from 7800 to 19,000. In this blade, the spanwise coolant passage at the trailing edge region whose thickness is very thin is chosen, so the channel aspect ratio (=width/height of channel) is extremely high, 4.76. Therefore the heat transfer experiment in the high‐aspect‐ratio cooling channel was performed using thermochromic liquid crystal and thermocouples. Furthermore, the calculation of flow and heat transfer was carried out using CFD analysis code to understand the heat transfer experimental results. The enhanced heat transfer coefficients on the smooth side wall at the rib's leading end were the same level as those on the rib‐roughened walls. © 2002 Scripta Technica, Heat Trans Asian Res, 31(2): 89–104, 2002; DOI 10.1002/htj.10018  相似文献   

19.
In this paper, a new configuration of ejector‐expansion transcritical CO2 (TRCC) refrigeration cycle is presented, which uses an internal heat exchanger and intercooler to enhance the performance of the new cycle. The theoretical analysis on the performance characteristics was carried out for the new cycle based on the first and second laws of thermodynamics. It was found that, compared with the conventional transcritical CO2 cycle and ejector‐expansion transcritical CO2 cycle, the simulation results show that the coefficient of performance and second law efficiency of the new cycle were increased by about 55.5 and 26%, respectively, under the operating conditions that evaporator temperature is 10°C, gas cooler outlet temperature is 40°C and gas cooler pressure is optimum pressure. It is also concluded that the entrainment ratio for the new ejector‐expansion TRCC cycle is on average 35% higher than that of the conventional ejector‐expansion TRCC cycle. The analysis results are of significance to provide theoretical basis for design optimization of the transcritical CO2 refrigeration cycle with an ejector‐expansion device, internal heat exchanger and intercooler. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

20.
The integration of an aqua‐ammonia inlet air‐cooling scheme to a cooled gas turbine‐based combined cycle has been analyzed. The heat energy of the exhaust gas prior to the exit of the heat recovery steam generator has been chosen to power the inlet air‐cooling system. Dual pressure reheat heat recovery steam generator is chosen as the combined cycle configuration. Air film cooling has been adopted as the cooling technique for gas turbine blades. A parametric study of the effect of compressor–pressure ratio, compressor inlet temperature, turbine inlet temperature, ambient relative humidity, and ambient temperature on performance parameters of plants has been carried out. It has been observed that vapor absorption inlet air cooling improves the efficiency of gas turbine by upto 7.48% and specific work by more than 18%, respectively. However, on the adoption of this scheme for combined cycles, the plant efficiency has been observed to be adversely affected, although the addition of absorption inlet air cooling results in an increase in plant output by more than 7%. The optimum value of compressor inlet temperature for maximum specific work output has been observed to be 25 °C for the chosen set of conditions. Further reduction of compressor inlet temperature below this optimum value has been observed to adversely affect plant efficiency. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号