首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Electron cyclotron emission imaging system in the frequency range of 95 GHz ~125 GHz is going to be constructed for a two-dimensional diagnosis of the electron temperature profiles and fluctuations on the HT-7 Tokamak. The optical design for the ECEI diagnostic system is completed. Because of the superconducting technology used in HT-7, the vacuum chamber is rather thick (630 mm), the height of the horizontal windows is limited (maximum 450 mm), which constrains greatly the ECE imaging Gaussian beam that passing through the windows. We here comes to make a design compromise between the number of the beams that can pass through the windows and the spatial resolution (around 1.1 cm). We also find that due to the field curvature of the optical system, the gaussian beams of edge channels are always overlapped. To flatten the field curvature, it is needed to insert a concave made of a material with a low refractive index (compared with the one used in the convex). But the suitable material has not been available so far, therefore the deterioration of the resolution in some channels (e.g. the edge channels) is acceptable.  相似文献   

2.
At the first stage of the electron cyclotron emission imaging (ECEI) diagnostic project on HT-7, a 16-channel vertical-resolved ECEI diagnostic has been developed and installed on HT-7 tokamak to measure electron cyclotron emission with a temporal resolution of 0.5 usec. The system works at a fixed frequency of 97.5 GHz. The sample volumes of the system are aligned vertically with a vertical channel spacing of 11 mm, and can be shifted across the plasma cross-section by varying the toroidal magnetic field. The high spatial resolution of the system is achieved by utilizing a low-cost linear mixer/receiver array and an optical imaging system. The focus location may be shifted horizontally when translating one of the optical imaging elements. The details of the system design and laboratory testing of the ECEI optics are presented together with the preliminary experimental results.  相似文献   

3.
An intelligent remote control system based on a power distribution unit (PDU) and Arduino has been designed for the electron cyclotron emission imaging (ECEI) system on Experimental Advanced Superconducting Tokamak (EAST).This intelligent system has three major functions:ECEI system reboot,measurement region adjustment and signal amplitude optimization.The observation region of ECEI can be modified for different physics proposals by remotely tuning the optical and electronics systems.Via the remote adjustment of the attenuation level,the ECEI intermediate frequency signal amplitude can be efficiently optimized.The remote control system provides a feasible and reliable solution for the improvement of signal quality and the efficiency of the ECEI diagnostic system,which is also valuable for other diagnostic systems.  相似文献   

4.
The spectral emission and plasma parameters of SnO_2 plasmas have been investigated.A planar ceramic SnO_2 target was irradiated by a CO2 laser with a full width at half maximum of 80 ns.The temporal behavior of the specific emission lines from the SnO_2 plasma was characterized.The intensities of Sn I and Sn II lines first increased,and then decreased with the delay time.The results also showed a faster decay of Sn I atoms than that of Sn II ionic species.The temporal evolutions of the SnO_2 plasma parameters(electron temperature and density) were deduced.The measured temperature and density of SnO_2 plasma are 4.38 eV to0.5 eV and 11.38×10~(17) cm~(-3) to 1.1×10~(17) cm~(-3),for delay times between 0.1 μs and 2.2 μs.We also investigated the effect of the laser pulse energy on SnO_2 plasma.  相似文献   

5.
Data analysis on tokamak plasmas is mainly based on various diagnostic systems, which are usually modularized and independent of each other. This leads to a large amount of data not being fully and effectively exploited so that it is not conducive to revealing the deep physical mechanism. In this work, Bayesian probability inference with machine learning methods have been applied to the electron cyclotron emission and Thomson scattering diagnostic systems on HL-2A/2M, and the effects of integrated data analysis (IDA) on the electron temperature of HL-2A with Bayesian probability inference are demonstrated. A program is developed to infer the whole electron temperature profile with a confidence interval, and the program can be applied in online analysis. The IDA results show that the full profile of the electron temperature can be obtained and the diagnostic information is more comprehensive and abundant with IDA. The inference models for electron temperature analysis are established and the developed programs will serve as an experimental data analysis tool for HL-2A/2M in the near future.  相似文献   

6.
As a new diagnostic means, plasma-imaging system has been developed on the HL-2A tokamak, with a basic understanding of plasma discharge scenario of the entire torus, checking the plasma position and the clearance between the plasma and the first wall during discharge. The plasma imaging system consists of (1) color video camera, (2) observation window and turn mirror, (3) viewing & collecting optics, (4) video cable, (5) Video capture card as well as PC. This paper mainly describes the experimental arrangement, plasma imaging system and detailed part in the system, along with the experimental results. Real-time monitoring of plasma discharge process, particularly distinguishing limitor and divertor configuration, the imaging system has become key diagnostic means and laid the foundation for further physical experiment on the HL-2A tokamak.  相似文献   

7.
Design of the Transmission Lines for 140 GHz ECRH System on HL-2A   总被引:1,自引:0,他引:1  
A new 140 GHz/2 MW/3 s electron cyclotron resonance heating (ECRH) system composed of two units is now being constructed on HL-2A. As a part of the system, two trans- mission lines marked No.7 & 8 play the role of carrying microwave power from two gyrotrons to the tokamak port. Based on the oversized circular corrugated waveguide technology, an evacu~ ated transmission system with high power capability and high transmission efficiency is designed. Details are presented for the design of the corrugated waveguide, the layout of the proposed lines and the vacuum pumping system. Then mode conversion losses due to coupling, misalignment, bends and gaps are discussed to serve as a reference for analyzing the transmission efficiency and alignment. Finally, a dual-modes propagation case consisting of the HEll and LPn even modes is discussed.  相似文献   

8.
通过求解等离子体平衡方程、波迹方程和准线性Fokker-Planck方程,数值模拟了电子回旋(EC)波在非圆截面托卡马克等离子体中的传播轨迹和功率沉积。模拟结果表明:当EC波从顶部发射时,相比于圆截面的EC波波迹,非圆截面的波迹会向等离子体弱场侧偏移,增大等离子体中心电子密度,波迹也会偏向弱场侧,相应的波功率沉积有所降低;当EC波O模从中平面弱场侧发射时,随着平行折射率的增大,波迹弯曲幅度变大,增大到一定数值时会折回弱场侧穿出,波功率沉积随极向发射角的增大而降低,环向发射角约取10°时,波功率沉积达到最大。  相似文献   

9.
采用性能优越的15道硅漂移探测器(SDD)阵列,在EAST全超导托卡马克上建立了1套较为完善的软X射线能谱诊断系统,用以测量等离子体在软X射线辐射能段(1~20keV)的能谱。该诊断系统的观测范围基本覆盖了整个等离子体空间,因此,可满足EAST不同放电位形下电子温度测量的要求。利用该诊断系统,可获得时间分辨达50ms、空间分辨约为7cm的电子温度剖面。通过对比发现,由该诊断系统所得到的电子温度与其它电子温度诊断系统所测量的电子温度基本一致。此外,该诊断系统还可监测在软X射线能量范围内出现的一些金属杂质的特征线辐射。  相似文献   

10.
Electron density (Ne) in a glow discharge plasma for the surface alloying technique is diagnosed by optical emission spectrometry (OES). With CH4 as the feeding gas, Ne is obtained by comparing the Hβ spectrum according to the Stark broadening effect. It is noticed that Ne varies with the working pressures (30 Pa to 70 Pa) and cathode voltages (500 V to 1000 V), respectively. Due to an abnormal glow discharge, Ne is between 1. 71 × 10^15 /cm^3 to 6.64 × 10^15 /cm^3 and increases rapidly with working gas pressures and cathode voltages. The results show that OES is a useful method to measure the plasma parameters in a surface alloying glow discharge plasma.  相似文献   

11.
A visible light imaging Thomson scattering (VIS-TVTS) diagnostic system has been developed for the measurement of plasma electron temperature on the HT-7 tokamak. The system contains a Nd:YAG laser (A = 532 nm, repetition rate 10 Hz, total pulse duration ≈ 10 ns, pulse energy 〉 1.0 J), a grating spectrometer, an image intensifier (I.I.) lens coupled with an electron multiplying CCD (EMCCD) and a data acquisition and analysis system. In this paper, the measurement capability of the system is analyzed. In addition to the performance of the system, the capability of measuring plasma electron temperature has been proved. The profile of electron temperature is presented with a spatial resolution of about 0.96 cm (seven points) near the center of the plasma.  相似文献   

12.
Electron heating via lower hybrid current drive (LHCD) has been investigated in HT-7 superconducting tokamak. Experiments show that the central electron temperature Te0, the volume averaged electron temperature 〈 Te 〉 and the peaking factor of the electron temperature QTe = Teo/〈 Te 〉 increase with the lower hybrid wave (LHW) power. Simultaneously the electron heating efficiency and the electron temperature as the function of the central line-averaged electron density (ne) and the plasma current (Ip) have also been investigated. The experimental results are in a good agreement with those of the classical collision theory and the LHW power deposition theory.  相似文献   

13.
14.
Diagnostic Neutral Beam (DNB) has been used for measuring plasma parameters of tokamaks such as ion and electron temperature, safety factor, impurity concentration and etc. Ion source and electrical power supply specification are the main part of DNB. Arc discharge current value is affected by filament current and anode voltage. Beam current changes with arc current signal in our experiment that agree with theoretical relations. Sixty milli-ampere (60 mA) pulse beam current is because of arc current of about 40 A and extraction voltage of about 20 kV. The increase of beam current with arc current has been reported experimentally and effect of arc current on beam current has been investigated for several high extraction voltages. Optimum condition, which means having a telescopic beam (minimum divergence) for specific parameters of duoplasmatron, has been simulated and verified with experimental test. The best extraction voltage for these parameters has been found to be about 16-kV. The ratio of the perpendicular velocity to parallel velocity has been calculated to be about 0.012. It has been shown experimentally with optical emission spectroscopy that increase in arc current and magnetic current increase proton content of beam.  相似文献   

15.
This article describes the data processing and acquisition system for the HT-7 multipulse Thomson scattering diagnostic. An eight-pulse laser is used in the Thomson scattering system to obtain electron temperature profiles at eight different times throughout an entire plasma discharge. The major components of the diagnostic system consist of a multipulse iNd-glass laser,a photodetector‘‘s subsystem, a calibration set and a CAMAC data processing and acquisition system. The data processing software along with LeCroy 2250L will perform the data acquisition.In order to simplify the operation and extend the capability of its compatibility with other math softwares, the processing software has been improved by the authors. The new software based on the VC easily utilizes some math softwares to calculate the electron temperature. The new software is simpler and more operational than the old one.  相似文献   

16.
A streaked optical pyrometer (SOP) is developed and calibrated for the measurement of the temperature of shocked materials. In order to achieve a higher relative sensitivity, a onechannel scheme is adopted for the system. The system is calibrated with a shocked step-shaped aluminum sample in the SG-III prototype laser facility. The relation between the count number in the detection system and the sample temperature is thus obtained, which can be adopted to infer the temperature of any shocked materials in future experiments.  相似文献   

17.
As advanced linear plasma sources, cascaded arc plasma devices have been used to generate steady plasma with high electron density, high particle flux and low electron temperature. To measure electron density and electron temperature of the plasma device accurately, a laser Thomson scattering(LTS) system, which is generally recognized as the most precise plasma diagnostic method, has been established in our lab in Dalian University of Technology. The electron density has been measured successfully in the region of 4.5?×?10(19)m~(-3) to7.1?×?10~(20)m~(-3) and electron temperature in the region of 0.18 eV to 0.58 eV. For comparison,an optical emission spectroscopy(OES) system was established as well. The results showed that the electron excitation temperature(configuration temperature) measured by OES is significantly higher than the electron temperature(kinetic electron temperature) measured by LTS by up to 40% in the given discharge conditions. The results indicate that the cascaded arc plasma is recombining plasma and it is not in local thermodynamic equilibrium(LTE). This leads to significant error using OES when characterizing the electron temperature in a non-LTE plasma.  相似文献   

18.
J-TEXT, formerly TEXT-U at the University of Texas at Austin in USA, is a medium-sized tokamak at the Huazhong University of Science and Technology. The toroidal field (TF) power supply of this tokamak should provide a current of 160 kA and a flat duration of 500 ms for the toroidal field coils to generate a maximum toroidal field of 3 T at the geometric center of the vaccum vessel. This paper presents a design of a new control system which takes the real-time feedback control option for the TF power supply operation. The system was tested successfully during the commissioning. In the first experimental campaign of J-TEXT, the system effectively controlled the power supply to provide a fiat current up to 92.5 kA and therein the TF produced reached 1.74 T, which enabled the machine to generate the first plasma successfully.  相似文献   

19.
电子回旋共振管是产生高功率毫米微波的真空电子器件,在可控热核聚变研究、雷达等领域中有重要的应用。针对可控热核聚变研究中1 MW/105 GHz回旋管加热系统阳极电源幅度可调且调制的要求,使用高频开关电源技术和脉冲步进调制技术(PSM)研制了全固态阳极高压电源。重点阐述了阳极高压电源实现稳压、调制、前沿时间可调功能的软件控制算法,并通过实验对设计进行了验证。该阳极高压电源具有单脉冲、多脉冲调制和六电平预置波形等3种模式输出功能;输出参数达到35 kV/200 mA,波形前沿3 ms内可调,最大调制频率为1 kHz,调节精度在100 V以内。设计的控制方法也可应用于其他大功率微波源。  相似文献   

20.
Electron thermal transport is one of the most complex processes in fusion plasmas.It is generally described by a simple thermal diffusivity in transport analyses of discharges,but there is evidence of critical gradient effects with moderate stiffness.By analyzing periodic perturbations to an equilibrium,one can measure the variations in electron energy flux and electron temperature gradient over the perturbation cycle,obtaining the flux as a function of gradient over the range of parameters generated by the perturbation.Although time-dependent transport analysis is very sensitive to noise in the input data,averaging over many cycles of a periodic perturbation can provide data of sufficient quality.The analyses presented here are based on the ECE temperature data with high spatial and temporal resolution and full profile coverage on DIII-D for sawteeth and modulated ECH heating.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号