首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Noise measurements have been performed on the neutron flux and the fuel concentration of the KEMA Suspension Test Reactor. The behaviour of the autopower spectral density function of the neutron flux is given with respect to reactor power and fuel burn up.

To investigate the concentration fluctuations the load of the suspension pump has been analysed.

Apart from the measurements on the Suspension Test Reactor, noise analysis has been performed on the temperature on the outside of the feed water inlet nozzle and on its thermal sleeve of the Dodewaard Boiling Water Reactor.

Temperature distributions indicate the leakage of feed water through the annulus, formed by the nozzle and the thermal sleeve. Amplitude distribution measurements show the magnitude of the circumferential temperature fluctuations on the thermal sleeve. From cross correlation measurements of the temperature fluctuations in nozzle and thermal sleeve the flow pattern in this region has been determined. From the results, temperature fluctuations at the inner radius and the bore of the feed water inlet nozzle can be derived.  相似文献   


2.
A Boiling Water Reactor core concept has been proposed using a new fuel component called spectral shift rod (SSR). The SSR is a new type of water rod in which a water level is formed during core operation. The water level can be controlled by the core recirculation flow rate. By using SSRs, the reactor can be operated with all control rods withdrawn through the operation cycle as well as that a much larger natural uranium saving is possible due to spectral shift operation than in current BWRs. The steady state and transient characteristics of the SSRs have been examined by experiments and analyses to certify the feasibility. In a reference design, a four times larger spectral shift width as for the current BWR has been obtained.  相似文献   

3.
It is currently a common practice that a boiling water reactor (BWR) adopts hydrogen water chemistry (HWC) for mitigating corrosion in structural components in its primary coolant circuit. When the core flow rate (CFR) in a BWR is changed, the coolant residence time in the primary coolant circuit would be different. The concentrations of major redox species (i.e. hydrogen, oxygen, and hydrogen peroxide) in the coolant may accordingly vary due to different durations of radiolysis in the core and other near-core regions. A theoretical model by the name of DEMACE was used in the current study to investigate the impact of various CFRs (from 100% to 80.0%) on the effectiveness of HWC in a domestic BWR. Our analyses indicated that the HWC effectiveness at some locations could be downgraded due to a decrease in CFR. However, a lower CFR was instead beneficial to the corrosion mitigation efficiency of HWC at other locations. The impact of CFR on the HWC effectiveness could vary from location to location in a BWR and eventually from plant to plant.  相似文献   

4.
In the current design of the simplified boiling water reactor, the vacuum breaker check valve is an important safety component. The vacuum breaker check valve is the only key safety components which is not passive in nature. Failure of this mechanical valve drastically reduces the passive containment cooling system cooling capability and hence containment pressure may exceed the design pressure. To eliminate this problem novel vacuum breaker check valve was developed to replace the mechanical valve. This new design is based on a passive hydraulic head, which is fail-safe and is truly passive in operation. Moreover this new design needs only one additional tank and one set of piping each to the wetwell and drywell. This system is simple in design and hence is easy to maintain and to qualify for operation. The passive vacuum breaker check valve performance was first evaluated using RELAP5. Then the passive vacuum breaker check valve was constructed and implemented in the PUMA integral test facility. Its performance was studied in a large break loss of coolant accident simulation test performed in PUMA facility.  相似文献   

5.
The Advanced Boiling Water Reactor (ABWR) is being developed by an international team of BWR manufacturers to respond to worldwide utility needs in the 1990s. Major objectives of the ABWR program are design simplification; improved safety and reliability; reduced construction, fuel and operating costs; improved maneuverability; and reduced occupational exposure and radwaste.The ABWR incorporates the best proved features from BWR designs in Europe, Japan, and the United States and application of leading edge technology. Key features of the ABWR are internal recirculation pumps; fine-motion, electro-hydraulic control rod drives; digital control and instrumentation; multiplexed, fiber optic cabling network; pressure suppression containment with horizontal vents; cylindrical reinforced concrete containment; structural integration of the containment and reactor building; severe accident capability; state-of-the-art fuel; advanced turbine/generator with 52 in. last stage buckets; and advanced radwaste technology.The ABWR is being developed as the next generation Japan standard BWR under the guidance and leadership of the Tokyo Electric Power Company, Inc. and a group of Japanese BWR utilities. During 1987, the Tokyo Electric Power Company, Inc. announced its decision to proceed with two ABWR units at its Kashiwazaki-Kariwa Nuclear Power Station, with commercial operation of the first unit in 1996 and the second unit in 1998. The units will be supplied by a joint venture of General Electric, Hitachi and Toshiba, with General Electric selected to supply the nuclear steam supply systems, fuel and turbine/generators. In the United States it is being adapted to the needs of U.S. utilities through the Electric Power Research Institute's Advanced LWR Requirements Program, and is being reviewed by the U.S. Nuclear Regulatory Commission for certification as a preapproved U.S. Standard BWR under the U.S. Department of Energy's ALWR Design Verification Program. These cooperative Japanese and U.S. Programs are expected to establish the ABWR as a world class BWR for the 1990s.International cooperative efforts are also underway aimed at development of a simplified BWR employing natural circulation and passive safety systems. This BWR concept, while only in the conceptual design stage, shows significant technical and economic promise.  相似文献   

6.
A design concept of PbBi cooled direct contact boiling water small fast reactor (PBWFR) has been formulated with some design parameters identified. Water is injected into hot PbBi above the core, and direct contact boiling takes place in chimneys. Boiling bubbles rise due to buoyancy effects, which works as a lift pump for PbBi circulation. The generated steam passes through separators and dryers for the removal of PbBi droplets, and then flows into turbines for the generation of electricity. The system pressure of 7 MPa is as the same as that of the conventional boiling water reactors (BWRs). The outlet steam is superheated by 10°C to avoid the accumulation of condensate on a PbBi free surface in the reactor vessel. The control rods are inserted from above, which is different from the original concept. This insertion was chosen since the seal of steam at the top of the reactor vessel is technically much easier than the seal of PbBi at the bottom of the reactor vessel. The electric power of 150 MWe may be the maximum which is practically possible as a small reactor with economic competitiveness to conventional LWRs. A two-region core is designed. A decrease in reactivity was estimated to be 1.5%dk/kk′ for 15 years. A fuel assembly has 271 fuel rods with 12.0 mm in diameter and 15.9 mm in pitch in a hexagonal wrapper tube. The design limit of cladding temperature is specified to be 650°C for compatibility of cladding material with PbBi. As a result, the PbBi core outlet temperature becomes 460°C. The PbBi temperature rise in the core is 150°C. The conditions of the secondary coolant steam are as the same as those of conventional BWRs with thermal efficiency of 33%. The core is designed to have the breeding ratio of 1.1 and the refueling interval of 15 years as a reactor with a long-life core. Direct heat exchangers (DHX), reactor vessel air cooling systems (RVACS) and guard vessel are designed.  相似文献   

7.
Application of optimal control to a boiling water nuclear reactor is the theme of this paper. The optimal control problem of a linearized model of a reactor is treated as a regulator problem and feedback control laws are derived to drive the system to steady state in the presence of disturbances. The weighting matrices in the performance index of the regulator problem are suitably changed to yield acceptable closed-loop responses for specific disturbances. The disturbances considered are (i) impulse change in temperature of water at inlet to plenum chamber and (ii) step change in throttle valve area. Then the feedback control laws are implemented on the nonlinear model to illustrate their effectiveness both for large and small disturbances.  相似文献   

8.
Researchers at the Idaho National Engineering Laboratory performed an assessment of the aging of the reactor internals in boiling water reactors (BWRs), and identified the unresolved technical issues related to the degradation of these components. The overall life-limiting mechanism is intergranular stress corrosion cracking (IGSCC). Irradiation-assisted stress corrosion cracking, fatigue, and thermal aging embrittlement are other potential degradation mechanisms. Several failures in BWR internals have been caused by a combination of factors such as environment, high residual or preload stresses, and flow-induced vibration. The ASME Code Section XI in-service inspection requirements are insufficient for detecting aging-related degradation at many locations in reactor internals. Many of the potential locations for IGSCC or fatigue are not accessible for inspection.  相似文献   

9.
For the decommissioning of the Fukushima Daiichi Nuclear Power Plant, it is necessary to consider the access route to the fuel debris for its removal, which can be determined by knowing the corruption situation of the core support structure. To predict the damage condition of reactor vessel, dissolution behavior of the core structure material should be understood. In this study, the dissolution behavior of core structure materials (stainless steel) by molten metallic corium (stainless steel + B4C) originated from control rod and its cladding was investigated. As a result of immersion experiment, it was found that there were two types of dissolution mode in this system: (1) chemical dissolution by eutectic reaction between Fe and B and (2) physical dissolution caused by the grains falling off from solid steel due to infiltration of molten metal. Moreover, on the basis of kinetic analysis, it was considered that the chemical dissolution in this system was slow. Therefore, the dissolution is considered to mainly occur through the mechanism that physical dissolution precedes chemical dissolution.  相似文献   

10.
11.
In order to design more stable and safer core configurations, experimental and theoretical studies about BWR (Boiling Water Reactor) instability have been performed to characterize the phenomenon and to predict the conditions for its occurrence. The instabilities can be caused by interdependencies between thermal-hydraulic and reactivity feedback parameters such as the void-coefficient, for example, during a pressure perturbation event. In this work, the RELAP5-MOD3.3 thermal-hydraulic system code and the PARCS-2.4 3D neutron kinetic code were coupled to simulate BWR transients. The pressure perturbation is considered in order to study in detail this type of transient. Two different algorithms developed at the University of Pisa were used to calculate the Decay Ratio (DR) and the natural frequency (NF) from the power oscillation signals obtained from the transient calculations. The validation of a code model set up for the Peach Bottom-2 BWR plant is performed against Low-Flow Stability Tests (LFST). The four series of Stability Tests were performed at Peach Bottom Unit 2 in 1977 at the end of cycle 2 in order to measure the reactor core stability margins at the limiting conditions used in design and safety analysis.  相似文献   

12.
《Annals of Nuclear Energy》2005,32(6):558-571
This paper is concerned with the design of a boiling water reactor (BWR) equilibrium core using thorium as a nuclear material in an integrated blanket–seed (BS) assembly. The integrated BS concept comes from the fact that the blanket and the seed rods are located in the same assembly, and are burned out in a once-through cycle. The idea behind the lattice design is to use the thorium conversion capability in a BWR spectrum, taking advantage of the 233U build-up. A core design was developed to achieve an equilibrium cycle of 365 effective full power days in a standard BWR with a reload of 104 fuel assemblies designed with an average 235U enrichment of 7.5 w/o in the seed sub-lattice. The main operating parameters, like power, linear heat generation rate and void distributions were obtained as well as the shutdown margin. It was observed that the analyzed parameters behave like those obtained in a standard BWR. The shutdown margin design criterion was fulfilled by addition of a burnable poison region in the fuel assembly.  相似文献   

13.
One of the limiting contributors to the heat load constraint for a long term spent fuel repository is the decay of americium-241. A possible option to reduce the heat load produced by Am-241 is to eliminate it via transmutation in a light water reactor thermal neutron environment, in particular, by taking advantage of the large thermal fission cross section of Am-242 and Am-242m. In this study we employ lattice loading optimization techniques to define the loadings and arrangements of fuel pins with blended americium and uranium oxide in boiling water reactor bundles, specifically, by defining the incineration of pre-loaded americium as an objective function to maximize americium transmutation. Subsequently, the viability of these optimized lattices is tested by assembling them into bundles with Am-spiked fuel pins and by loading these bundles into realistic three-dimensional BWR core-wide simulations that model multiple reload cycles and observe standard operational constraints. These simulations are possible via our collaboration with the Westinghouse Electric Co. which facilitates the use of industrial-caliber design tools such as the PHOENIX-4/POLCA-7 sequence and the Core Master 2© GUI work environment for fuel management.  相似文献   

14.
A theoretical model was adapted to evaluate the impact of power uprate on the water chemistry of a commercial boiling water reactor (BWR) in this work. In principle, the power density of a nuclear reactor upon a power uprate would change immediately, followed by water chemistry variations due to enhanced radiolysis of water in the core and near-core regions. It is currently a common practice for commercial BWRs to adopt hydrogen water chemistry (HWC) for corrosion mitigation. The optimal feedwater hydrogen concentration may be different after a power uprate is implemented in a BWR. A computer code DEMACE was used in the current study to investigate the impact of various power uprate levels on major radiolytic species concentrations and electrochemical corrosion potential (ECP) behavior of components in the primary coolant circuit of a domestic BWR-6 type reactor operating under either normal water chemistry or HWC. Our analyses indicated that under a constant core flow rate the chemical species concentrations and the ECP did not vary monotonously with increases in reactor power level at a fixed feedwater hydrogen concentration. In particular, the upper plenum and the upper downcomer regions exhibited uniquely higher ECPs at 108% and 115% power levels than at the other evaluated power levels.  相似文献   

15.
Our aim was to evaluate the sensitivity and uncertainty of mass flow rate in the core on the performance of natural circulation boiling water reactor (NCBWR). This analysis was carried out through Monte Carlo simulations of sizes up to 40,000, and the size, i.e., repetition of 25,000 was considered as valid for routine applications. A simplified boiling water reactor (SBWR) was used as an application example of Monte Carlo method. The numerical code to simulate the SBWR performance considers a one-dimensional thermo-hydraulics model along with non-equilibrium thermodynamics and non-homogeneous flow approximation, one-dimensional fuel rod heat transfer. The neutron processes were simulated with a point reactor kinetics model with six groups of delayed neutrons. The sensitivity was evaluated in terms of 99% confidence intervals of the mean to understand the range of mean values that may represent the entire statistical population of performance variables. The regression analysis with mass flow rate as the predictor variable showed statistically valid linear correlations for both neutron flux and fuel temperature and quadratic relationship for the void fraction. No statistically valid correlation was observed for the total heat flux as a function of the mass flow rate although heat flux at individual nodes was positively correlated with this variable. These correlations are useful for the study, analysis and design of any NCBWR. The uncertainties were propagated as follows: for 10% change in the mass flow rate in the core, the responses for neutron power, total heat flux, average fuel temperature and average void fraction changed by 8.74%, 7.77%, 2.74% and 0.58%, respectively.  相似文献   

16.
17.
18.
RELAP5/MOD2 is an advanced thermal-hydraulic computer code used to analyze plant response to postulated transient and loss-of-coolant accidents in light water nuclear reactors. Since this computer code was originally developed for pressurized water reactor transient analysis, some of its capabilities are questioned when the methods are applied to a boiling water reactor. One of the areas which requires careful assessment is the jet pump model.In this paper, the jet pump models of RELAP5/MOD2, RETRAN-02/MOD3, and RELAP4/MOD3 are compared. From an investigation of the momentum equations, it is found that the jet pump models of these codes are not exactly the same. However, the effects of the jet pump models on the M-N characteristic curve are negligible.In this study, it is found that the relationship between the flow ratio, M, and the head ratio, N, is uniquely determined for a given jet pump geometry provided that the wall friction and gravitational head are neglected. In other words, under the given assumptions, the M-N characteristic curve will not change with power level, recirculation pump speed or loop flow rate. When the effects of wall friction and gravitational head are included, the shape of the M-N curve will change. For certain conditions, the slope of the M-N curve can even change from negative to positive. The changes in the M-N curve caused by the separate effects of the wall friction and gravitational head will be presented. Sensitivity studies on the drive flow nozzle form loss coefficients, Kd, the suction flow junction form loss coefficients, KS, the diffuser form loss coefficient, Ke, and the ratio of different flow areas in the jet pump are performed. Finally, useful guidelines will be presented for plants without a plant specific M-N curve.  相似文献   

19.
20.
The stress corrosion cracking (SCC) behaviour of different reactor pressure vessel (RPV) steels and weld filler/heat-affected zone materials was characterized under simulated boiling water reactor (BWR) normal water (NWC) and hydrogen water chemistry (HWC) conditions by periodical partial unloading, constant and ripple load tests with pre-cracked fracture mechanics specimens. The experiments were performed in oxygenated or hydrogenated high-purity or sulphate/chloride containing water at temperatures from 150 to 288 °C. In good agreement with field experience, these investigations revealed a very low susceptibility to SCC crack growth and small crack growth rates (<0.6 mm/year) under most BWR/NWC and material conditions. Critical water chemistry, loading and material conditions, which can result in sustained and fast SCC well above the ‘BWRVIP-60 SCC disposition lines’ were identified, but many of them generally appeared atypical for current optimized BWR power operation practice or modern RPVs. Application of HWC always resulted in a significant reduction of SCC crack growth rates by more than one order of magnitude under these critical system conditions and growth rates dropped well below the ‘BWRVIP-60 SCC disposition lines’.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号