首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The thermal performance and phase change stability of stearic acid as a latent heat energy storage material has been studied experimentally. The thermal performance and heat transfer characteristics of the stearic acid were tested and compared with other studies given in the literature. In the present study, parameters such as transition times, temperature range and propagation of the solid–liquid interface as well as the effect of the heat flow rate on the phase change stability of stearic acid as a phase change material (PCM) were studied. The experimental results showed that the melting stability of the PCM is better in the radial direction than in the axial direction. The variation in the melting and solidification parameters of the PCM with the change of inlet water temperature is also studied. We observed that while the heat exchanger tube is in the horizontal position, the PCM has more effective and steady phase change characteristics than in the vertical position. The heat storage capacity of the container (PCM tube) is not as good as we expected in this study and the average heat storage efficiency (or heat exchanger effectiveness) is 50.3%. This indicates that 49.7% of the heat is actually lost somewhere.  相似文献   

2.
A horizontal double-pipe heat exchanger with an inverted outer equilateral triangular tube is modeled to numerically investigate the low-temperature thermal energy storage capability of an impure phase change material (PCM). The energy source fluid (hot water) flows through the inner tube and transfers heat to the PCM (heat sink) residing in the annular gap. The results show that the inlet temperature of the heat transfer fluid (HTF) has a significant effect on the melting process compared with the mass flow rate (MFR). The configuration, as well the concentricity/eccentricity of the inner tube has a great influence on the energy storage.  相似文献   

3.

Thermal energy storage performance of fatty acids and a eutectic mixture as phase change materials (PCMs) has been investigated experimentally. The selected PCMs for this study were palmitic acid, myristic acid, stearic acid, and a mixture of stearic and myristic acids in eutectic combination ratio of 65.7 wt% myristic acid and 34.3 wt% stearic acid. The PCMs have a melting temperature range of 50.0°C to 61.20°C and a latent heat range of 162.0 J/g to 204.5 J/g. The inlet temperature and the mass flow rate of heat transfer fluid (HTF) were selected as experimental parameters to test the thermal energy storage performance of the PCMs. The transition times, temperature range, propagation of the solid-liquid interface, as well as heat flow rate characteristics of the employed cylindrical tube storage system were studied at varied experimental parameters. The experimental results show that the melting front moves to inward in the radial directions as well as in the axial directions from the top toward to the bottom of the PCM tube. It was observed that the convection heat transfer in the liquid phase plays an important role in the melting process. The changes in the studied HTF parameters have more effect on the melting processes than the solidification processes of the PCMs. The average heat storage efficiency calculated from data for all the PCMs is 51.5%, meaning that 48.5% of the heat actually was lost somewhere.  相似文献   

4.
A latent heat thermal energy storage system using a phase change material (PCM) is an efficient way of storing or releasing a large amount of heat during melting or solidification. It has been determined that the shell‐and‐tube type heat exchanger is the most promising device as a latent heat system that requires high efficiency for a minimum volume. In this type of heat exchanger, the PCM fills the annular shell space around the finned tube while the heat transfer fluid flows within the tube. One of the methods used for increasing the rate of energy storage is to increase the heat transfer surface area by employing finned surfaces. In this study, energy storage by phase change around a radially finned tube is investigated numerically and experimentally. The solution of the system consists of the solving governing equations for the heat transfer fluid (HTF), pipe wall and phase change material. Numerical simulations are performed to investigate the effect of several fin parameters (fin spacing and fin diameter) and flow parameter (Re number and inlet temperature of HTF) and compare with experimental results. The effect of each variable on energy storage and amount of solidification are presented graphically. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

5.
An experimental analysis is presented to establish the thermal performance of a latent heat thermal storage (LHTS) unit. Paraffin is used as the phase change material (PCM) on the shell side of the shell and tube‐type LHTS unit while water is used as the heat transfer fluid (HTF) flowing through the inner tube. The fluid inlet temperature and the mass flow rate of HTF are varied and the temperature distribution of paraffin in the shell side is measured along the radial and axial direction during melting and solidification process. The total melting time is established for different mass flow rates and fluid inlet temperature of HTF. The motion of the solid–liquid interface of the PCM with time along axial and radial direction of the test unit is critically evaluated. The experimental results indicate that the melting front moves from top to bottom along the axial direction while the solidification front moves only in the radial direction. The total melting time of PCM increases as the mass flow rate and inlet temperature of HTF decreases. A correlation is proposed for the dimensionless melting time in terms of Reynolds number and Stefan number of HTF. © 2013 Wiley Periodicals, Inc. Heat Trans Asian Res; Published online in Wiley Online Library ( wileyonlinelibrary.com/journal/htj ). DOI 10.1002/htj.21120  相似文献   

6.
为探究相变温度对相变材料回填地埋管换热器传热性能的影响,建立管内流体换热、回填区域相变换热及土壤换热的三维耦合传热数值模型,利用焓-多孔介质模型对相变区域相变问题进行处理,研究夏季间歇运行工况下不同相变温度回填材料对埋管换热器传热性能的影响。结果表明:添加PCM,可有效提高换热量,短期内缓解埋管周围热积聚,利用相变温度18℃的PCM回填,单位井深换热量至少比普通材料回填提高49.54%;在间歇运行初期,换热量随相变温度的升高逐渐减小,低相变温度的PCM可明显改善埋管换热量,但随着时间的进行,较高相变温度PCM回填对换热器换热量的改善效果优于前期低相变温度。此外,在运行期间,不同相变温度的PCM表现出不同的熔化、凝固特性,当PCM的熔化、凝固过程交替进行时,可减缓土壤温度在运行期间内波动幅度。  相似文献   

7.
Lauric acid (m.p.: 42.6°C) and myristic acid (m.p.: 52.2°C) are phase change materials (PCM) having quite high melting points which can limit their use in low‐temperature solar applications such as solar space heating and greenhouse heating. However, their melting temperatures can be tailored to appropriate value by preparing a eutectic mixture of lauric acid (LA) and myristic acid (MA). In the present study, the thermal analysis based on differential scanning calorimetry (DSC) technique shows that the mixture of 66.0 wt% LA forms a eutectic mixture having melting temperature of 34.2°C and the latent heat of fusion of 166.8 J g?1. This study also considers the experimental establishment of thermal characteristics of the eutectic PCM in a vertical concentric pipe‐in‐pipe heat storage system. Thermal performance of the PCM was evaluated with respect to the effect of inlet temperature and mass flow rate of the heat transfer fluid on those characteristics during the heat charging and discharging processes. The DSC thermal analysis and the experimental results indicate that the LA–MA eutectic PCM can be potential material for low‐temperature solar energy storage applications in terms of its thermo‐physical and thermal characteristics. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

8.
An experimental energy storage system has been designed using an horizontal shell and tube heat exchanger incorporating a medium temperature phase change material (PCM) with a melting point of 117.7 °C. Two experimental configurations consisting of a control unit with one heat transfer tube and a multitube unit with four heat transfer tubes were studied. The thermal characteristics in the systems have been analysed using isothermal contour plots and temperature time curves. Temperature gradients along the three directions of the shell and tube systems; axial, radial and angular directions have been analysed and compared. The phase change in the multitube system was dominated by the effect of convective heat transfer compared to conductive heat transfer in the control system. The temperature gradient in the PCM during phase change was greatest in the radial direction for both the control and multitube systems. The temperature gradients recorded in the axial direction for the control and multitube systems during the change of phase were respectively 2.5 and 3.5% that of the radial direction, indicating essentially a two-dimensional heat transfer in the PCM. The onset of natural convection through the formation of multiple convective cells in the multitube system significantly altered the shape of the solid liquid interface fluid flow and indicates the requirement for an in-depth study of multitube arrangements.  相似文献   

9.
Thermal energy storage is critical for reducing the discrepancy between energy supply and energy demand, as well as for improving the efficiency of solar thermal energy systems. Among the different types of thermal energy storage, phase-change materials (PCM) thermal energy storage has gained significant attention recently because of its high energy density per unit mass/volume at nearly constant temperature. This study experimentally investigates the using of a triplex tube heat exchanger (TTHX) with PCM in the middle tube as the thermal energy storage to power a liquid desiccant air-conditioning system. Four longitudinal fins were welded to each of the inner and middle tubes as a heat transfer enhancement in the TTHX to improve the thermal performance of the thermal energy storage. The average temperature of the PCM during the melting process in the TTHX with and without fins was compared. The PCM temperature gradients in the angular direction were analyzed to study the effect of the natural convection in the melting process of the thermal storage. The energy storage efficiency of the TTHX was determined. Results indicated that there was a considerable enhancement in the melting rate by using fins in the TTHX thermal storage. The PCM melting time is reduced to 86% by increasing of the inlet heat transfer fluid. The average heat storage efficiency calculated from experimental data for all the PCMs is 71.8%, meaning that 28.2% of the heat actually was lost.  相似文献   

10.
This work aims to evaluate the performance of an integrated phase change material (PCM) solar collector. The dynamic behavior of the system is investigated via a theoretical model based on the first law of thermodynamics and oriented to deliver a maximum outlet water temperature. A parametric study is used to assess the effects of the inlet water temperature, the PCM thicknesses and properties and the mass flow rates on the outlet water temperature and the melt fraction. A comparison with a conventional solar water heater without heat storage is made. Results indicate that charging and discharging processes of PCM offer six stages. It is observed that the complete solidification time is longer than the melting one. The latent heat storage system increases the heating requirements at night. The rise is most enhanced for higher inlet water temperature, melting PCM temperature and PCM thickness and for lower mass flow rate.  相似文献   

11.
This paper describes the development and performance of a direct-contact heat exchanger using erythritol (melting point: 391 K) as a phase change material (PCM) and a heat transfer oil (HTO) for accelerating heat storage. A vertical cylinder with 200-mm inner diameter and 1000-mm height was used as the heat storage unit (HSU). A nozzle facing vertically downward was placed at the bottom of the HSU. We examined the effects of flowrate and inlet temperature of the HTO using three characteristic parameters of heat storage – difference between inlet and outlet HTO temperatures, temperature effectiveness, and heat storage rate. The temperature history of latent heat storage (LHS) showed three stages: sensible heat of solid PCM, latent heat of PCM, and sensible heat of liquid PCM. Further, the operating mechanism of the DCHEX was proposed to explain the results. The average heat storage rate during LHS was proportional to the increase in flowrate and inlet temperature of HTO. Thus, latent heat can be rapidly stored under large HTO flowrate and high inlet temperature in the DCHEX.  相似文献   

12.
A combined experimental and numerical study is performed aiming to understand the role of buoyancy-driven convection during constrained melting of phase change materials (PCMs) inside a shell and tube heat exchanger. A series of experiments is conducted to investigate the effect of increasing the inlet temperature of the heat transfer fluid (HTF) on the charging process (melting) of the PCM. The computations are based on an iterative, finite-volume numerical procedure that incorporates a single-domain enthalpy formulation for simulation of the phase change phenomenon. It was observed from experimental results that the melting front appeared at different times at positions close to the HTF tube and progressing at different rates outwards towards the shell. The computational results show that by increasing the inlet water temperature to 80 °C, the total melting time is decreased to 37%.  相似文献   

13.
The use of a heat exchanger using phase change material (PCM) is an example of latent heat thermal energy storage (LHTES). In this study, the charging of PCM (RT50) is studied in a double pipe heat exchanger. The designing of the heat exchanger needs to be optimized for operating and boundary conditions to store latent heat efficiently. The size of the equipment and the amount of PCM are also important to calculate the latent heat storage capacity of the LHTES device. In this study, the amount of PCM taken is quite high to avoid sensible heat transfer and to maximize the heat content of PCM. The charging process of PCM is numerically simulated using an enthalpy-porosity model. The study includes the effect of inlet temperature and flow rate of high-temperature-fluid (HTF) and concludes that both play an important role in determining the charging time. The continuous increase in inlet temperature of HTF can decrease the charging time of PCM in the heat exchanger. However, the continuous increase in the HTF flow rate cannot show the same effect. The charging time can only be minimized with a specified flow rate regime for a specific inlet temperature of HTF. These factors consequently affect the efficiency of the heat exchanger.  相似文献   

14.
相变蓄热技术近年来在电力削峰填谷的应用中发挥了重要作用,成为供热领域的新热点。本文设计了以PTC电加热棒为发热源,水为载热介质,纳米共晶水合盐为相变蓄热材料的管壳式相变蓄热器。实验研究了蓄放热过程中装置内部水和相变材料的温度分布情况以及特定温度范围的蓄放热性能及变化规律。结果表明,以圆管正三角阵列 + 折流板为特征的管壳式换热器结构可以使蓄热器内部温度分布更加均匀;以某测温点水温75 ~ 98℃变化区间为蓄放热周期,蓄热周期的实际蓄热量为779 796 kJ,有效蓄热系数达到0.91,平均蓄热功率为94.13 kW;在放热周期,放热功率从74.2 kW随水温的下降而逐渐减小至51.8 kW,当水温降至相变温度以下时,放热功率趋于稳定。  相似文献   

15.
Long Jian-you 《Solar Energy》2008,82(11):977-985
This paper addresses a numerical and experimental investigation of a thermal energy storage unit involving phase change process dominated by heat conduction. The thermal energy storage unit involves a triplex concentric tube with phase change material (PCM) filling in the middle channel, with hot heat transfer fluid (HHTF) flowing outer channel during charging process and cold heat transfer fluid (CHTF) flowing inner channel during discharging process. A simple numerical method according to conversation of energy, called temperature & thermal resistance iteration method has been developed for the analysis of PCM solidification and melting in the triplex concentric tube. To test the physical validity of the numerical results, an experimental apparatus has been designed and built by which the effect of the inlet temperature and the flow rate of heat transfer fluid (HTF, including HHTF and CHTF) on the thermal energy storage has been studied. Comparison between the numerical predictions and the experimental data shows good agreement. Graphical results including fluid temperature and interface of solid and liquid phase of PCM versus time and axial position, time-wise variation of energy stored/released by the system were presented and discussed.  相似文献   

16.
Nanoencapsulated phase change material (NPCM) slurry is a dispersion where the phase change material (PCM) is dispersed in fluid. Compared with fluid, these nanofluids have a higher heat capacity during the phase change and a possible enhancement, as a result of this phase change, in the heat transfer phenomenon. To appreciate the merits, in terms of energy, a numerical study has been carried out with fluid based on NPCM inside double pipe heat exchanger. The numerical simulation results have been validated using experimental heat transfer data. The Reynolds and Nusselt numbers have been determined using thermal conductivity and viscosity evaluated in the same conditions as those in numerical model. The results obtained show an improvement of this energetic criterion at low mass flow rate compared with the base fluid. Analysis of the numerical and analytical results reveal that higher inlet flow rate and NPCM concentration results in higher heat transfer rate. In addition, increasing NPCM slurry temperature decreases its performance due to fast melting of PCM inside the tube.  相似文献   

17.
《Energy》2002,27(9):869-888
The mixture of capric acid and lauric acid (C-L acid), with the respective mole composition of 65% and 35%, is a potential phase change material (PCM). Its melting point of 18.0°C, however, is considered high for cooling application of thermal energy storage. The thermophysical and heat transfer characteristics of the C-L acid with some organic additives are investigated. Compatibility of C-L acid combinations with additives in different proportions and their melting characteristics are analyzed using the differential scanning calorimeter (DSC). Among the chemical additives, methyl salicylate, eugenol, and cineole presented the relevant melting characteristics. The individual heat transfer behavior and thermal storage performance of 0.1 mole fraction of these additives in the C-L acid mixture are evaluated. The radial and axial temperature distribution during charging and discharging at different concentrations of selected PCM combinations are experimentally determined employing a vertical cylindrical shell and tube heat exchanger. The methyl salicylate in theC-L acid provided the most effective additive in the C-L acid. It demonstrated the least melting band width aimed at lowering the melting point of the C-L acid with the highest heat of fusion value with relatively comparable rate of heat transfer. Furthermore, the thermal performance based on the total amount of transferred energy and their rates, established the PCM’s latent heat storage capability.  相似文献   

18.
Theoretical investigations of fatty acids as a phase change material (PCM) for energy storage system have been conducted in this study. The selected fatty acids were capric acid, lauric acid, myristic acid, palmitic acid and stearic acid. For the two-dimensional simulation model based on the enthalpy approach, calculations have been made for the melt fraction with conduction only. Glass, stainless steel, tin, aluminium mixed, aluminium and copper were used as heat exchanger materials in the numerical calculations. Theoretical results show that capric acid was found good compatibility with latent heat storage system. The large value of thermal conductivity of heat exchanger materials did not make significant contribution on the melt fraction.  相似文献   

19.
Free cooling night ventilation is the process of storing the coolness in the night time and releasing this coolness in hot day time. In this paper, a numerical study was carried out to simulate and to find out the optimum design for plate type storage filled with phase change material (PCM) which is used in night ventilation systems. The effect of different parameters such as thickness of PCM-plates, inlet air temperature and air mass flow rates on melting front, cooling power, outlet temperature and thermal performance of heat exchanger was studied. The results showed that cooling power can be increased by increasing the mass flow rate. Also, the thickness of the plates in the storage device plays an important role in the thermal performance of the unit and has a linear relation with the melting process duration of PCM for considered configuration.  相似文献   

20.
A computer program was proposed to simulate the behavior of a low-temperature phase-change material (PCM) in a heat exchanger for short-term storage. An experimental set-up of mainly a heat exchanger with a staggered tube arrangement and air temperature control unit were used. In the modeling approach, the PCM in the tube was divided into 10 concentric cells of equal mass, and was logically treated in terms of energy balance. Experimental inlet air temperature (at three different flow rates) was utilized as input data to test the model output results and their reliability. Excellent agreement was obtained for the outlet air temperature when compared with the experimental measurements, and differences did not exceed 0.5°C over the simulated period. The predicted PCM average temperature history showed good agreement with the experimental ones, and differences did not exceed 2° at the highest applied air flow rate. This modeling approach can be used for any PCM, provided that its thermophysical properties are available. The transient moving front for freezing or melting can be predicted, and consequently the mass fraction of either liquid or solid phase to the total PCM mass can be predicted as well.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号