首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
There is a large potential to reduce primary energy use and CO2 emissions from the Swedish building stock. Here detached houses heated by oil, natural gas or electric boilers were assessed. CO2 emissions, primary energy use and heating costs were evaluated before and after implementing house envelope measures, conversions to more efficient heating systems and changes to biomass fuel use. The study included full energy chains, from natural resources to usable heat in the houses. The aim was to evaluate the societal economic cost effectiveness of reducing CO2 emission and primary energy use by different combinations of changes. The results demonstrated that for a house using an electric boiler, a conversion to a heat pump combined with house envelope measures could be cost efficient from a societal economic perspective. If the electricity was based on biomass, the primary energy use was at the same time reduced by 70% and the CO2 emission by 97%. Large emission reductions were also seen for conversions from oil and gas boilers to a biomass-based system. However, for these conversions the heating cost increased, leading to a mitigation cost of around €50/tonne C avoided. The price of oil and natural gas greatly influenced the competitiveness of the alternatives. House envelope measures were more cost-effective for houses with electric boilers as the cost of energy for this system is high. The results are specific to a Swedish context, but also give an indication of the potential in other regions, such as northern European and large parts of North America, which have both a cold climate and a widespread use of domestic boilers.  相似文献   

2.
In this study, we first analyse energy-efficiency measures in existing electrically heated houses in Sweden from a societal economic perspective. Measures to a house envelopes and to energy supply chains are evaluated through a system analysis approach and we include the external costs of climate change and the effect of different Swedish climatic zones. We find that in a typical house from the 1970s, conversion from electric heating is highly motivated since the mitigation cost of conversion is lower than the estimated external costs of emitted CO2. Both conversions and house envelope measures are more motivated in the northern part of the country, where there is a higher heat demand. A successful implementation of changes requires them to be attractive for consumers to adopt. We therefore secondly analyse the economic conditions for Swedish house owners to implement societal economic cost-efficient measures. We include the economic influence of an investment subsidy for heating system conversion, an income tax deduction for changing windows, customer electricity tax, real estate tax and of the cost of purchased energy from different energy suppliers. Apart from the economics, several other factors affect a house owner's decision to change heating systems. We therefore thirdly analyse house owners’ perceptions of different heating supply alternatives based on the results of two comprehensive questionnaires. These different perspectives are combined in a discussion whether the studied policy instruments encourage house owners to implement changes in accordance with the energy-efficiency goals of decision makers. We find that the investment subsidy could be useful to break the lock-in effect of resistance heaters, which house owners seemed to experience. The electricity tax makes heating systems in line with national goals more competitive and efficiency measures to the house envelope more profitable. The reduction of the electricity tax in the northern part of the country has the opposite effect. Also, the increase in real estate tax when implementing energy-efficiency measures gives a contradictory message. The price differences between energy suppliers has a larger impact on the house owners’ economic conditions than both subsidies and tax rate changes, and possibly also affect the house owner's attitudes towards various systems.  相似文献   

3.
In this paper, we evaluate the viability of a 9.5‐kWe wooden pellet‐fueled Stirling engine‐based micro‐cogeneration plant as a substitute for small‐scale district heating. The district heating systems against which the micro‐cogeneration plant is compared are based either on a pellet‐fueled boiler or a ground‐source heat pump. The micro‐cogeneration and district heating plants are compared in terms of primary energy consumption, CO2 emissions, and feasibility of the investment. The comparison also considers an optimally operated individual 0.7‐kWe pellet‐fueled Stirling engine micro‐cogeneration system with exhaust gas heat recovery. The study is conducted in two different climates and contributes to the knowledge base by addressing: (i) hourly changes in the Finnish electricity generation mix; and (ii) uncertainty related to what systems are used as reference and the treatment of displaced grid electricity. Our computational results suggest that when operated at constant power, the 9.5‐kWe Stirling engine plant results in reduced annual primary energy use compared with any of the alternative systems. The results are not sensitive to climate or the energy efficiency or number of buildings. In comparison with the pellet‐fueled district heating plant, the annual use of primary energy and CO2 emissions are reduced by a minimum of 25 and 19%, respectively. Owing to a significant displacement of grid electricity, the system's net primary energy consumption appears negative when the total built area served by the plant is less than 1200 m2. On the economic side, the maximum investment cost threshold of a CHP‐based district heating system serving 10 houses or more can typically be positive when compared with oil and pellet systems, but negative when compared with a corresponding heat pump system. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

4.
The operation of a district heating system depends on the heat load demand, which varies throughout the year. In this paper, we analyze the coproduction of district heat and electricity or biomotor fuels. We demonstrate how three different taxation scenarios and two crude oil price levels influence the selection of production units to minimize the district heat production cost and calculate the resulting primary energy use. Our analysis is based on the annual measured heat load of a district heating system. The minimum-cost district heat production system comprises different production units that meet the district heat demand and simultaneously minimize the district heat production cost. First, we optimize the cost of a district heat production system based on the cogeneration of electricity and heat with and without biomass integrated gasification combined-cycle technology. We considered cogenerated electricity as a byproduct with the value of that produced by a condensing power plant. Next, we integrate and optimize different biomotor fuel production units into the district heat production system by considering biomotor fuels as byproducts that can substitute for fossil motor fuels. We demonstrate that in district heating systems, the strengthening of environmental taxation reduces the dependence on fossil fuels. However, increases in environmental taxation and the crude oil price do not necessarily influence the production cost of district heat as long as biomass price is not driven by policy measures. Biomotor fuel production in a district heating system is typically not cost-efficient. The biomotor fuels produced from the district heating system have to compete with those from standalone biomotor fuel plants and also with its fossil-based counterparts. This is also true for high oil prices. A carbon tax on fossil CO2 emissions based on social cost damage will increase the competitiveness of biomass-based combined heat and power plants, especially for BIGCC technology with its high electricity-to-heat ratio.  相似文献   

5.
The role of district heating in future renewable energy systems   总被引:1,自引:0,他引:1  
Based on the case of Denmark, this paper analyses the role of district heating in future Renewable Energy Systems. At present, the share of renewable energy is coming close to 20 per cent. From such point of departure, the paper defines a scenario framework in which the Danish system is converted to 100 per cent Renewable Energy Sources (RES) in the year 2060 including reductions in space heating demands by 75 per cent. By use of a detailed energy system analysis of the complete national energy system, the consequences in relation to fuel demand, CO2 emissions and cost are calculated for various heating options, including district heating as well as individual heat pumps and micro CHPs (Combined Heat and Power). The study includes almost 25 per cent of the Danish building stock, namely those buildings which have individual gas or oil boilers today and could be substituted by district heating or a more efficient individual heat source. In such overall perspective, the best solution will be to combine a gradual expansion of district heating with individual heat pumps in the remaining houses. Such conclusion is valid in the present systems, which are mainly based on fossil fuels, as well as in a potential future system based 100 per cent on renewable energy.  相似文献   

6.
In Sweden, where district heating accounts for a significant share of residential heating, it has been argued that improvements in end-use energy efficiency may be counter-productive since such measures reduce the potential of energy efficient combined heat and power production. In this paper we model how the potential trade-offs between energy supply and end-use technologies depend on climate policy and energy prices. The model optimizes a combination of energy efficiency measures, technologies and fuels for heat supply and district heating extensions over a 50 year period. We ask under what circumstances improved end-use efficiency may be cost-effective in buildings connected to district heating? The answer hinges on the available technologies for electricity production. In a scenario with no alternatives to basic condensing electricity production, high CO2 prices result in very high electricity prices, high profitability of combined heat and power production, and little incentive to reduce heat demand in buildings with district heating. In contrast, in a scenario where electricity production alternatives with low CO2 emissions are available, the electricity price will level out at high CO2 prices. This gives heat prices that increase with the CO2 price and make end-use efficiency cost-effective also in buildings with district heating.  相似文献   

7.
The built environment needs to develop sustainable, decarbonised, low energy systems and approaches that are socially acceptable and economically beneficial. The UK mainstream house construction industry is being driven, through policy and regulation, towards achieving this end without evidence of how these new systems of provision are used by passively adopting households. In this paper energy use, consequential emissions of CO2, and annual running costs for a case study comprising 14 newly constructed low energy affordable homes are evaluated. Four different energy typologies are compared: ground sourced heat pumps; active solar (thermal and photovoltaic); passive solar and mechanical ventilation with heat recovery; conventional high efficiency gas boiler. The carbon embodied in construction and emitted over a 20 year occupation period for each typology is calculated. Ground source heat pumps have the highest annual primary energy demand, CO2 emission and annual running costs over the 20 year period. The homes with active solar technologies provided most benefit across all three evaluation criteria. Energy and CO2 emissions associated with end uses other than heating were similar to the UK average. This poses significant questions on the probability of policy application in the real world to deliver projected reductions in emissions of CO2.  相似文献   

8.
The objective of the study is to analyse the conditions for connection of residential buildings in heat sparse areas to district heating systems in order to increase electricity production in municipal combined heat and power plants. The European electricity market has been assumed to be fully deregulated. The relation between connection of heat sparse areas, increased electricity and heat production as well as electricity prices, fuel prices and emissions rights is investigated. The results of the study show that there is potential to expand the district heating market to areas with lower heat concentrations in the cities of Gävle, Sandviken and Borlänge in Sweden, with both economic and environmental benefits. The expansion provides a substantial heat demand of approximately 181 GWh/year, which results in an electricity power production of approximately 43 GWh/year. Since the detached and stand-alone houses in the studied heat sparse areas have been heated either by oil boiler or by direct electricity, connection to district heating also provides a substantial reduction in emissions of CO2. The largest reductions in CO2 emissions are found to be 211 ktonnes/year assuming coal-fired condensing power as marginal electricity production. Connection of heat sparse areas to district heating decrease the system costs and provide a profitability by approximately 22 million EURO/year for the studied municipalities if the price of electricity is at a European level, i.e. 110 EURO/MWh. Sensitivity analysis shows, among other things, that a strong relation exists between the price of electricity and the profitability of connecting heat sparse areas to district heating systems.  相似文献   

9.
《Biomass & bioenergy》2002,22(3):169-177
This is an analysis of the effect on the technical solution when monetary values of externalities are included in a model for optimising energy systems. The focus of the study is on heating in domestic houses, non-residential premises, multi-dwelling buildings and district heating systems. The included monetary values of damage to the environment and health are those resulting from atmospheric emissions of CO2, NOx, SO2 and particulates. The estimates are taken from the literature. An optimising method based on linear programming is used and the result is an optimal mix of energy carriers as well as new and existing heating plants that minimise the costs of satisfying a demand for heat. Furthermore, a calculation is made of the externality cost resulting from the energy system. The analysis makes it possible to compare the technical and economic differences of an energy system based on business economics to a system with greater emphasis on socio-economics. Generally speaking, it is cost-effective to take externality costs into consideration at the planning stage instead of correcting the damage later. The results show that by considering externality costs the total discounted cost of the energy system would be approximately 30% lower than today. Furthermore, the use of pellets and wood chips should be substantially larger in all of the studied regions.  相似文献   

10.
《Applied Thermal Engineering》2007,27(7):1158-1164
The various governmental policies aimed at reducing the dependence on fossil fuels for space heating and the reduction in its associated emission of greenhouse gases such as CO2 demands innovative measures. District heating systems using residual industrial waste heats could provide such an efficient method for house and space heating. In such systems, heat is produced and/or thermally upgraded in a central plant and then distributed to the final consumers through a pipeline network.This paper studies the technical, economic, institutional and environmental feasibilities of using low-level residual industrial waste heat for the district heating of Delft, The Netherlands.An integrated conceptual design approach that takes into account both the technical and institutional design of the system has been adopted and has resulted in a feasible and robust system design. The technical part of the integrated conceptual design consisted in the estimation of the heat demands, the design of the heat upgrading system, equipment sizing, the network morphology and/or spatial connectivity and the exergy losses in the needed infrastructure as well as the economic viability of the system. An isopropanol–hydrogen–acetone chemical heat pump was selected for the process and has been modelled in ASPEN plus®. The conventional cost estimation model has been modified to account for uncompensated system downtimes.  相似文献   

11.
Integrated Energy Systems (IES), as technology that use thermal activated components to recover waste heat, are energy systems that offer key solution to global warming and energy security through high overall energy efficiency and better fuel use. Combined Cooling, Heating, and Power (CCHP) Systems are IES that use recovered thermal energy from the prime mover to produce heating and cooling for the building. The CCHP operational strategy is critical and it has to be considered in a well designed system since it defines the ultimate goal for the benefits expected from the system. One of the most common operational strategies is the cost-oriented strategy, which allows the system to operate at the lowest cost. A primary energy strategy (PES) optimizes energy consumption instead of cost. However, as a result of the worldwide concern about global warming, projects that target reduction of greenhouse gas (GHG) emissions have gained a lot of interest. Therefore, for a CCHP system, an emission strategy (ES) would be an operational strategy oriented to minimize emission of pollutants. In this study, the use of an ES is proposed for CCHP systems targeted to reduce emission of pollutants. The primary energy consumption (PEC) reduction and carbon dioxide (CO2) emission reduction obtained using the proposed ES are compared with results obtained from the use of a PES. Results show that lower emission of CO2 is achieved with the ES when compared with the PES, which prove the advantage of the ES for the design of CCHP systems targeted to emissions reduction.  相似文献   

12.
Cline Weber  Daniel Favrat 《Energy》2010,35(12):5070-5081
District energy systems can potentially decrease the CO2 emissions linked to energy services, thanks to the implementation of large polygeneration energy conversion technologies connected to buildings over a network. To transfer the energy from these large technologies to the users, conventional district energy systems use water with often two independent supply and return piping systems for heat and cold. However, sharing energy or interacting with decentralised heat pump units often results in relatively large heat transfer exergy losses due to the large temperature differences that are economically required from the water network. Besides, the implementation of two independent supply and return piping systems for heat and cold, results in large space requirements in underground technical galleries. Using refrigerants as a district heating or cooling fluid at an intermediate temperature could alleviate some of these drawbacks. A new system has been developed, that requires only two pipes, filled with refrigerant, to meet heating, hot water and cooling requirements. Because of the environmental concerns about conventional refrigerants, CO2, a natural refrigerant, used under its critical point, is considered an interesting candidate. A comparative analysis shows that both in terms of exergy efficiency and costs the proposed CO2 network is favourable.  相似文献   

13.
Our aim is to examine how different attributes of residential heating systems affect private homeowners' choice of heating system following renovations when heterogeneity in the homeowners' preferences is considered. Utilizing the results of our choice model, we then aim to simulate the market shares of different heating systems under various policy scenarios. The data were retrieved by a questionnaire mailed to a random sample of Finnish private owners of detached houses built in the 1960s–1990s with a response rate of 52%. The labeled choice sets in the discrete choice experiment (DCE) had 6 heating system alternatives (wood pellet boiler, solid wood fired boiler, district heat, electricity, ground heat (pump) and oil boiler) with varying levels of predetermined attributes (investment cost, annual operating cost, CO2 emissions, fine particle emissions and required own work). The choice modeling results emphasized the role of the investment cost as the main attribute affecting the decisions, although nonfinancial attributes also had a considerable effect. Systematic preference heterogeneity was caused by the availability of district heat, the existing heating system and the homeowner's forest ownership. In addition, the results indicated a significant unobserved preference heterogeneity. Based on the simulation of market shares, the use of wood pellets in residential heating is projected to increase threefold during 2009–2020.  相似文献   

14.
China's carbon dioxide (CO2) emission ranks the highest in the world. CO2 emission from urban central heating, which has an average annual growth rate of 10.3%, is responsible for 4.4% of China's total CO2 emission. The current policy for improving urban central heating focuses on replacing coal with natural gas. This paper analyzes the existing situation and problems pertaining to urban heating, and evaluates the potential for reducing energy consumption and CO2 emission by heat pump heating. The results show that the current policy of replacing coal with natural gas for urban central heating decreases energy consumption and CO2 emission by 16.6% and 63.5%, respectively. On the other hand, replacing coal-based urban central heating with heat pump heating is capable of decreasing energy consumption and CO2 emission by 57.6% and 81.4%, respectively. Replacing both urban central and decentralized heating with heat pump heating can lead to 67.7% and 85.8% reduction in energy consumption and CO2 emission, respectively. The decreases in CO2 emission will account for 24.5% of China's target to reduce total CO2 emission by 2020.  相似文献   

15.
This paper evaluates system aspects of biorefineries based on biomass gasification integrated with pulp and paper production. As a case the Billerud Karlsborg mill is used. Two biomass gasification concepts are considered: BIGDME (biomass integrated gasification dimethyl ether production) and BIGCC (biomass integrated gasification combined cycle). The systems analysis is made with respect to economic performance, global CO2 emissions and primary energy use. As reference cases, BIGDME and BIGCC integrated with district heating are considered. Biomass gasification is shown to be potentially profitable for the mill. The results are highly dependent on assumed energy market parameters, particularly policy support. With strong policies promoting biofuels or renewable electricity, the calculated opportunity to invest in a gasification-based biorefinery exceeds investment cost estimates from the literature. When integrated with district heating the BIGDME case performs better than the BIGCC case, which shows high sensitivity to heat price and annual operating time. The BIGCC cases show potential to contribute to decreased global CO2 emissions and energy use, which the BIGDME cases do not, mainly due to high biomass demand. As biomass is a limited resource, increased biomass use due to investments in gasification plants will lead to increased use of fossil fuels elsewhere in the system.  相似文献   

16.
Decreased energy use is crucial for achieving sustainable energy solutions. This paper presents current and possible future electricity use in Swedish industry. Non-heavy lines of business (e.g. food, vehicles) that use one-third of the electricity in Swedish industry are analysed in detail. Most electricity is used in the support processes pumping and ventilation, and manufacturing by decomposition. Energy conservation can take place through e.g. more efficient light fittings and switching off ventilation during night and weekends. By energy-carrier switching, electricity used for heat production is replaced by e.g. fuel. Taking technically possible demand-side measures in the whole lines of business, according to energy audits in a set of factories, means a 35% demand reduction. A systems analysis of power production, trade, demand and conservation was made using the MODEST energy system optimisation model, which uses linear programming and considers the time-dependent impact on demand for days, weeks and seasons. Electricity that is replaced by district heating from a combined heat and power (CHP) plant has a dual impact on the electricity system through reduced demand and increased electricity generation. Reduced electricity consumption and enhanced cogeneration in Sweden enables increased electricity export, which displaces coal-fired condensing plants in the European electricity market and helps to reduce European CO2 emissions. Within the European emission trading system, those electricity conservation measures should be taken that are more cost-efficient than other ways of reducing CO2 emissions. The demand-side measures turn net electricity imports into net export and reduce annual operation costs and net CO2 emissions due to covering Swedish electricity demand by 200 million euros and 6 Mtonne, respectively. With estimated electricity conservation in the whole of Swedish industry, net electricity exports would be larger and net CO2 emissions would be even smaller.  相似文献   

17.
This paper introduces and evaluates a novel heating and cooling concept employing thermo-active building systems and environmental energy, harnessed from two 11-m3 rainwater cisterns for a 285-m2 residential building in passive house standard in Germany. The building strives for a significantly reduced primary energy use with carefully coordinated measures, such as high quality building envelope, by means of vacuum insulated panels, supply and exhaust air system with heat recovery, reduced solar heat gains (solar shading), and the integration of thermal solar collectors and photovoltaic in the plant system. On this premise, a comprehensive long-term monitoring in high time-resolution was carried out for the building for two years with an accompanying commissioning of the building performance. Measurements comprise the energy use for heating, cooling, and ventilation, as well as the auxiliary equipment, the performance of the environmental heat source and sink (rainwater cistern), thermal comfort, and local climatic site conditions.  相似文献   

18.
This article investigates the potentials of energy saving and greenhouse gases emission mitigation offered by implementation of building energy efficiency policies in China. An overview of existing literature regarding long-term energy-demand and carbon dioxide (CO2) emission forecast scenarios is presented. Energy consumption in buildings could be reduced by 100–300 million tons of oil equivalent (mtoe) in 2030 compared with the business-as-usual (BAU) scenario, which means that 600–700 million metric tons of CO2 emissions could be saved by implementing appropriate energy policies within an adapted institutional framework. The main energy-saving potentials in buildings can be achieved by improving a building's thermal performance and district heating system efficiency. The analyses also reveal that the energy interchange systems are effective especially in the early stage of penetration. Our analysis on the reviewed models suggests that more ambitious efficiency improvement policies in both supply- and demand-side as well as the carbon price should be taken into account in the policy scenarios to address drastic reduction of CO2 emission in the building sector to ensure climate security over the next decades.  相似文献   

19.
Dong Chen 《传热工程》2020,41(9-10):800-813
Abstract

A new method was developed and validated against numerical simulations for the calculation of ground heat transfer via floors with vertical edge insulations along the external side of walls. Using the new method, heating and cooling energy demand for two typical houses in the eight capital cities of Australian state and territory were evaluated with different vertical edge insulations and full horizontal floor insulations. It was found that for tropical regions such as Darwin, both vertical edge and full horizontal floor insulation have no or little effect on house heating and cooling energy demand. In cooling dominated climates such as Brisbane, full horizontal floor insulation may increase the total heating and cooling energy demand due to the decoupling between the relatively cool ground and the rooms above. For heating dominated climates such as Melbourne, Canberra and Hobart, ground heat loss can contribute up to around half of the total house heating and cooling energy demand. Full horizontal floor insulation can be very effective in these heating dominated climates. For heating and cooling balanced climates such as Adelaide, Perth and Sydney, vertical edge insulation along the external side of the walls is more effective than full floor insulation.  相似文献   

20.
ABSTRACT

Optimal energy renovations of apartment buildings in Finland have a great impact on annual energy demand. However, reduction of energy demand does not necessarily translate into similar changes in peak power demand. Four different types of apartment buildings, representing the Finnish apartment building stock, were examined after optimal energy retrofits to see the influence of retrofitting on hourly power demand. Switching from district heating to ground-source heat pumps reduced emissions significantly under current energy mix. However, the use of ground-source heat pumps increased hourly peak electricity demand by 46–153%, compared to district heated apartment buildings. The corresponding increase in electrical energy demand was 30–108% in the peak month of January. This could increase the use of high emission peak power plants and negate some of the emission benefits. Solar thermal collectors and heat recovery systems could reduce purchased heating energy to zero in summer. Solar electricity could reduce median power demand in summer, but had only a little effect on peak power demand. The reduction in peak power demand after energy retrofits was less than the reduction in energy demand.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号