共查询到20条相似文献,搜索用时 10 毫秒
1.
Garyfallos Giannakoudis Athanasios I. Papadopoulos Panos Seferlis Spyros Voutetakis 《International Journal of Hydrogen Energy》2010
The presented work addresses the design and optimization under uncertainty of power generation systems using renewable energy sources and hydrogen storage. A systematic design approach is proposed that enables the simultaneous consideration of synergies developed among numerous sub-systems within an integrated power generation system and the uncertainty involved in the system operation. The Stochastic Annealing optimization algorithm is utilized to handle the increased combinatorial complexity and to enable the consideration of different types of uncertainty in the performed optimization. A parallel adaptation of this algorithm is proposed to address the associated computational requirements through execution in a Grid computing environment. The proposed developments are implemented in a system that consists of photovoltaic panels, wind generators, accumulators, an electrolyzer, storage tanks, a compressor, a fuel cell and a diesel generator. Numerous design and operating parameters are considered as decision variables, while uncertain parameters are associated with weather fluctuations and operating efficiency of the employed sub-systems. The obtained results indicate robust performance under realizable system designs, in response to external or internal operating variations. 相似文献
2.
《Energy Policy》2016
Diverse solar PV business models and financing options exist in the international landscape, helping expand and accelerate the adoption of rooftop solar PV systems. The conditions for their emergence are context specific, depending on the policies, regulations, incentives, and market conditions of each country. After a review of the international landscape, this paper compiles and analyzes business models and financing options for rooftop solar PV investment in Thailand that have emerged during the period between 2013 and 2015. Despite policy discontinuity for the support of rooftop solar systems, diverse business models and financing options are driving market expansion and expanding solar access to more Thai consumers. Drawing on our policy and regulatory analyses and in-depth interviews with business representatives, we identify four types of business models and one financing option. The business models include Roof Rental, Solar PPA, Solar Leasing, and Community Solar, and the financing option is the solar loan. We analyze the drivers for their emergence, barriers to their success, and the risks from the business owners' and consumers' viewpoints. Our policy recommendation is focused on crafting a net-metering regulation with evidence-based studies on the potential costs and benefits to different stakeholders. 相似文献
3.
《International Journal of Hydrogen Energy》2020,45(20):11460-11470
A technico-economic analysis based on integrated modeling, simulation, and optimization approach is used in this study to design an off grid hybrid solar PV/Fuel Cell power system. The main objective is to optimize the design and develop dispatch control strategies of the standalone hybrid renewable power system to meet the desired electric load of a residential community located in a desert region. The effects of temperature and dust accumulation on the solar PV panels on the design and performance of the hybrid power system in a desert region is investigated. The goal of the proposed off-grid hybrid renewable energy system is to increase the penetration of renewable energy in the energy mix, reduce the greenhouse gas emissions from fossil fuel combustion, and lower the cost of energy from the power systems. Simulation, modeling, optimization and dispatch control strategies were used in this study to determine the performance and the cost of the proposed hybrid renewable power system. The simulation results show that the distributed power generation using solar PV and Fuel Cell energy systems integrated with an electrolyzer for hydrogen production and using cycle charging dispatch control strategy (the fuel cell will operate to meet the AC primary load and the surplus of electrical power is used to run the electrolyzer) offers the best performance. The hybrid power system was designed to meet the energy demand of 4500 kWh/day of the residential community (150 houses). The total power production from the distributed hybrid energy system was 52% from the solar PV, and 48% from the fuel cell. From the total electricity generated from the photovoltaic hydrogen fuel cell hybrid system, 80.70% is used to meet all the AC load of the residential community with negligible unmet AC primary load (0.08%), 14.08% is the input DC power for the electrolyzer for hydrogen production, 3.30% are the losses in the DC/AC inverter, and 1.84% is the excess power (dumped energy). The proposed off-grid hybrid renewable power system has 40.2% renewable fraction, is economically viable with a levelized cost of energy of 145 $/MWh and is environmentally friendly (zero carbon dioxide emissions during the electricity generation from the solar PV and Fuel Cell hybrid power system). 相似文献
4.
The Australian Government ran a renewable energy program in the 2000s that provided rebates to householders who acquired solar Photovoltaic (PV) energy systems. Originally called the Photovoltaic Rebate Program (PVRP), it was rebranded the Solar Homes and Communities Plan (SHCP) in November 2007. This paper evaluates both the PVRP and SHCP using measures of cost-effectiveness and fairness. It finds that the program was a major driver of a more than six-fold increase in PV generation capacity in the 2000s, albeit off a low base. In 2010, solar PV’s share of the Australian electricity market was still only 0.1%. The program was also environmentally ineffective and costly, reducing emissions by 0.09 MtCO2-e/yr over the life of the rebated PV systems at an average cost of between AU$238 and AU$282/tCO2-e. In addition, the data suggest there were equity issues associated with the program, with 66% of all successful applicants residing in postal areas that were rated as medium–high or high on a Socio-economic Status (SES) scale. 相似文献
5.
It is generally understood that the pattern of repeated expiration and short-term renewal of the federal production tax credit (PTC) causes a boom–bust cycle in wind power plant investment in the US. This on–off pattern is detrimental to the wind industry, since ramp-up and ramp-down costs are high, and players are deterred from making long-term investments. It is often assumed that the severe downturn in investment during “off” years implies that wind power is unviable without the PTC. This assumption turns out to be unsubstantiated: this paper demonstrates that it is not the absence of the PTC that causes the investment downturn during “off” years, but rather the uncertainty over its return. Specifically, it is the dynamic of power purchase agreement (PPA) negotiations in the face of PTC renewal uncertainty that drives investment volatility. With contract negotiations prevalent in the renewable energy industry, this finding suggests that reducing uncertainty is a crucial component of effective renewable energy policy. The PTC as currently structured is not the only means, existing or potential, for encouraging wind power investment. Using data from a survey of energy professionals, various policy instruments are compared in terms of their perceived stability for supporting long-term investment. 相似文献
6.
In this study, both concentrated solar power and wind energy systems are integrated with electrolyser, fuel cell and absorption cooling subsystems to supply power, cooling, heating and hydrogen to residential applications in an environmentally benign and efficient manner. These subsystems are integrated in a unique way to manage the excess power through water electrolysis to produce and store hydrogen. Integrated systems are thermodynamically analyzed, and their performance is assessed comparatively. Solar radiation intensity, inlet temperature and wind velocity are taken into account, and hence their effects on the system performance are investigated. The results of this study show that the present system appears to be efficient, environmentally friendly and hence sustainable. 相似文献
7.
Brazil's primary energy matrix is based on more than 47% of renewables, and more than 85% of its electricity is generated by hydro power sources. Despite this large fraction of renewable energy resources, less than 0.3% of the national energy supply comes from solar or wind sources. This paper presents a diagnostic review on the penetration of the solar and wind energy technologies in Brazil. It also includes a survey of the latest government policies and incentives for renewable energies deployment by entrepreneurs, industry and commercial and residential consumers. In addition, the paper analyses how to best meet the requirements for policy support and information technology to boost the deployment of solar technology and wind energy in Brazil. This study was mostly based on results of a widely distributed survey covering key issues, and also by personal interviews carried out with key stakeholders in order to better understand the issues highlighted in the survey responses. The study pointed out some of the main obstacles to effectively promote and improve government policies and actions for investment in solar and wind energy market in Brazil. 相似文献
8.
In this work, we validate and enhance previously proposed singe-input direct normal irradiance (DNI) models based on numerical weather prediction (NWP) for intra-week forecasts with over 200,000 hours of ground measurements for 8 locations. Short latency re-forecasting methods to enhance the deterministic forecast accuracies are presented and discussed. The basic forecast is applied to 15 additional locations in North America with satellite-derived DNI data. The basic model outperforms the persistence model at all 23 locations with a skill between 12.4% and 38.2%. The RMSE of the basic forecast is in the range of 204.9 W m−2 to 309.9 W m−2. The implementation of stochastic learning re-forecasting methods yields further reduction in error from 204.9 W m−2 to 176.5 W m−2. To a great extent, the errors are caused by inaccuracies in the NWP cloud prediction. Improved assessment of atmospheric turbidity has limited impact on reducing forecast errors. Our results suggest that NWP-based DNI forecasts are very capable of reducing power and net-load uncertainty introduced by concentrated solar power plants at all locations in North America. Operating reserves to balance uncertainty in day-ahead schedules can be reduced on average by an estimated 28.6% through the application of the basic forecast. 相似文献
9.
The development of renewable technologies in the last decade has been exceptional. In photovoltaic (PV) for example, efforts were not only limited to merely improving their efficiency but also to the reduction of the cost of cells and modules via volume production for commercial markets. There are many national schemes promoting the use of PV technology and regional targets for a share of renewable energy production. This paper attempts to relay to the reader a journey, based on experience, approaches for enhancing the prospect of utilising solar energy within the society we live in. The issue of expansion or enhancing the utilisation of solar energy can be undertaken by individuals, groups, institutions and governments. The aim of this paper is to provide some examples, which could serve as a framework in which action could be taken to promote solar technology. 相似文献
10.
In 2013, the feed-in tariff (FIT) policy was issued in China to promote the investment in renewable technology, but then it was revised because this policy brought a heavy financial burden to the government. By considering the intermittence of renewable resources, we model the implemented Chinese FIT policies and analyze their impact on renewable energy investment in the power market. The open-loop model is employed to simulate the China's power market organized with Power Purchase Agreement, and the closed-loop game is used to characterize the spot power market. Meanwhile, the strategic capacity choices of power generators in two games are compared under four different policy schemes: (i) free competition, (ii) FIT via fixed subsidy, (iii) FIT via price premium and (iv) Chinese FIT by cross control (CFCC). The results show that the CFCC policy is a good alternative to well control the investment in renewable technology, as it can be seen as a comprise between free competition and FIT via fixed subsidy policy. Furthermore, compared with the other three policy schemes, the CFCC policy is capable of keeping renewable power generators from deviating the equilibrium, which implies higher robustness in regulating the electricity spot market. 相似文献
11.
An experimental assessment of a hydrogen based regenerative (electrolyser-fuel cell) system is presented. The experiment was conducted on a residential scale Integrated Renewable Energy Experiment (IRENE) test-bed under conditions that are representative of the real demands that would be placed on a solar based, regenerative system, with a focus on dynamic operation under transients in both load and renewable energy supply profiles. A control algorithm employing bus voltage constraints and device current limitations is outlined. Results for a 2 week operating period indicate that the system response is very dynamic but repeatable. 相似文献
12.
Today, photovoltaic (PV) attracts considerable interest in relation to renewable energy technologies, because of its potential to contribute significantly to the future of renewable energy. However, PV market development is related strongly to the support policies introduced by national governments, defined in national laws. The modification or fading out of such incentive schemes can strongly influence the development of the PV market in any given country. In this paper, after a brief review of national support policies in PV technology in eastern European Union (EU) countries, the authors perform an economic analysis of the main support mechanisms that are implemented in these countries. The comparative analysis is based on the calculation of the cash flow, the Net Present Value (NPV) and the Internal Rate of Return (IRR) indices. The analysis shows that in some situations, support policies can be inconvenient for the owner of the PV system and that, in many cases, the differences between the implementation of the same support policy in different countries, can give rise to significantly different results. 相似文献
13.
Within various renewable energy technologies, photovoltaics (PV) today attracts considerable attention due to its potential to contribute a major share of renewable energy in the future. However, PV market development is, undoubtedly, dependent on the political support of any given country. 相似文献
14.
This recently completed study discusses the potential of conservation and solar energy in Michigan. While much of the quantitative analysis is specific to Michigan, the problems and opportunities discussed are largely generic to the northern industrial states in the USA. Technical estimates of energy savings potential are combined with economic analyses and market penetration considerations to provide an overall picture of the potential for conservation and solar energy. Barriers to market penetration are used as a basis for identifying a wide range of economic, informational, and institutional policy options for consideration by government and private sector decisionmakers. 相似文献
15.
A model of a solar-hydrogen powered residence, in both stand-alone and grid parallel configurations, was developed using Matlab/Simulink®. The model assesses the viability of employing a regenerative fuel cell (RFC) as an energy storage device to be used with photovoltaic (PV) electrical generation. Other modes of energy storage such as batteries and hybrid storage were also evaluated. Analyses of various operating conditions, system configurations, and control strategies were performed. Design requirements investigated included RFC sizing, battery sizing, charge/discharge rates, and state of charge limitations. Dynamic load demand was found to be challenging to meet, requiring RFC and or battery sizes significantly larger than those required to meet average power demand. Employing a RFC with batteries in a hybrid configuration increased PV utilization and both battery efficiency and power density. Grid parallel configurations were found to alleviate many of the difficulties associated with energy storage costs and meeting peak demand. 相似文献
16.
《Energy Policy》2014
This paper critically screens 153 lifecycle studies covering a broad range of wind and solar photovoltaic (PV) electricity generation technologies to identify 41 of the most relevant, recent, rigorous, original, and complete assessments so that the dynamics of their greenhouse gas (GHG) emissions profiles can be determined. When viewed in a holistic manner, including initial materials extraction, manufacturing, use and disposal/decommissioning, these 41 studies show that both wind and solar systems are directly tied to and responsible for GHG emissions. They are thus not actually emissions free technologies. Moreover, by spotlighting the lifecycle stages and physical characteristics of these technologies that are most responsible for emissions, improvements can be made to lower their carbon footprint. As such, through in-depth examination of the results of these studies and the variations therein, this article uncovers best practices in wind and solar design and deployment that can better inform climate change mitigation efforts in the electricity sector. 相似文献
17.
In this paper, a parametric study of the triple effect absorption cooling system (TEACS) integrated with solar photo-voltaic/thermal (PV/T), geothermal, and Linde–Hampson cycle is conducted. The effect of different operating parameters on the COPs, ratio ‘n’, amount of hydrogen gas pre-cooled, amount of hydrogen liquefied, and utilization factor of the integrated system are studied. It is found that when mass flow rate of air increases the energetic and exergetic COPs decrease in an exponential form from 2.6 to 1.9, and 0.4 to 0.3, respectively. The amounts of hydrogen gas pre-cooled and hydrogen liquefied decrease from 0.39 kg/s to 0.32 kg/s and 0.082 kg/s and 0.066 kg/s, respectively with increase in mass flow rate of air. Moreover, the amounts of hydrogen gas pre-cooled and hydrogen liquefied decrease from 0.42 to 0.27, and 0.088 to 0.066, respectively with increase in mass flow rate of geothermal. In addition, energetic and exergetic utilization factors of integrated system decrease from 0.059 to 0.037, and 0.21 and 0.13, respectively with increase in mass flow rate of geothermal. 相似文献
18.
Chong Li Dequn Zhou Weiyan Yu Hui Wang Dasheng Zhu Menghui Sun Guo Li 《International Journal of Hydrogen Energy》2017,42(10):6502-6510
This paper compares the performance of a 2.02 kWp off-grid residential solar photovoltaic (PV) power system using PVSYST simulation software for a household in Kunming, Yunnan province, China. The monthly available solar energy; missing energy; array, final, and reference yields, performance ratio; and array capture and system losses were analyzed for five solar tracking modes: fixed tilted plane, seasonal tilt adjustment, horizontal axis tracking, vertical axis tracking, and dual axis tracking. Although there were some similar aspects across the five systems, minimum available solar energy (2461 kWh/y) and maximum missing energy (134.68 kWh/y) were obtained using the fixed tilted plane system (tilt angle = 25°, azimuth angle = 0°), whereas maximum available solar energy (3081 kWh/y) and minimum missing energy (48.53 kWh/y) in October were obtained using the dual axis tracking system. Average monthly performance ratio was maximal for the fixed tilted plane system (0.689), and minimal for the dual axis tracking system (0.596). 相似文献
19.
Long-term field test of solar PV power generation using one-axis 3-position sun tracker 总被引:1,自引:0,他引:1
The 1 axis-3 position (1A-3P) sun tracking PV was built and tested to measure the daily and long-term power generation of the solar PV system. A comparative test using a fixed PV and a 1A-3P tracking PV was carried out with two identical stand-alone solar-powered LED lighting systems. The field test in the particular days shows that the 1A-3P tracking PV can generate 35.8% more electricity than the fixed PV in a partly-cloudy weather with daily-total solar irradiation HT = 11.7 MJ/m2 day, or 35.6% in clear weather with HT = 18.5 MJ/m2 day. This indicates that the present 1A-3P tracking PV can perform very close to a dual-axis continuous tracking PV (Kacira et al., 2004). The long-term outdoor test results have shown that the increase of daily power generation of 1A-3P tracking PV increases with increasing daily-total solar irradiation. The increase of monthly-total power generation for 1A-3P sun tracking PV is between 18.5-28.0%. The total power generation increase in the test period from March 1, 2010 to March 31, 2011, is 23.6% in Taipei (an area of low solar energy resource). The long-term performance of the present 1X-3P tracking PV is shown very close to the 1-axis continuous tracking PV in Taiwan (Chang, 2009). If the 1A-3P tracking PV is used in the area of high solar energy resource with yearly-average HT > 17 MJ/m2 day, the increase of total long-term power generation with respect to fixed PV will be higher than 37.5%. This is very close to that of dual-axis continuous tracking PV.The 1A-3P tracker can be easily mounted on the wall of a building. The cost of the whole tracker is about the same as the regular mounting cost of a conventional rooftop PV system. This means that there is no extra cost for 1A-3P PV mounted on buildings. The 1A-3P PV is quite suitable for building-integrated applications. 相似文献
20.
The absence of clean cooking facilities and electricity means billions of rural people are deprived of much needed socioeconomic development. Livestock residues (dung) and solar radiation are two renewable energy resources that are abundantly available in rural areas of developing countries. Although it is not feasible for these two resources separately to meet both thermal (cooking) and electricity demands, hybrid applications have not been given due attention. To facilitate integrating these two resources in rural energy planning, and to promote their dissemination through hybrid applications, it is necessary to evaluate their economic merits, and assess their ability to deal with the demands. In this paper, we examine the techno-economic performance of hybrid applications of these two resources by applying a simulation technique using the HOMER tool, and by giving derived cost-saving equations. We also quantify the monetary savings from replacing traditional fuels, and perform a sensitivity analysis on a number of variables (e.g. dung cost, fuelwood cost) to see how they affect the performance of different energy supply alternatives. Furthermore, we examine the practical applicability of the biogas system in the households through a structured survey of 72 ongoing household biogas plants. This study finds that households that have between three and six cattle can potentially meet their cooking and electricity loads through a hybrid implementation of biogas and solar PV (Photovoltaic) system. By replacing conventional fuels households can achieve savings that are more than the total annualized costs incurred for installing new services. 相似文献