1.
This paper reports on the experimental characterization of collapse-mode operation of capacitive micromachined ultrasonic transducers (CMUTs). CMUTs are conventionally operated by applying a direct current (DC) bias voltage less than the collapse voltage of the membrane, so that the membrane is deflected toward the bottom electrode. In the conventional regime, there is no contact between the membrane and the substrate; the maximum alternating current (AC) displacement occurs at the center of the membrane. In collapse-mode operation, the DC bias voltage is first increased beyond the collapse voltage, then reduced without releasing the collapsed membrane. In collapse-mode operation, the center of the membrane is always in contact with the substrate. In the case of a circular membrane, the maximum AC displacement occurs along the ring formed between the center and the edge of the membrane. The experimental characterization presented in this paper includes impedance measurements in air, pulse-echo experiments in immersion, and one-way optical displacement measurements in immersion for both conventional and collapse-mode operations. A 205-microm x 205-microm 2-D CMUT array element composed of circular silicon nitride membranes is used in the experiments. In pulse-echo experiments, a custom integrated circuit (IC) comprising a pulse driver, a transmit/receive switch, a wideband low-noise preamplifier, and a line driver is used. By reducing the parasitic capacitance, the use of a custom IC enables pulse-echo measurements at high frequencies with a very small transducer. By comparing frequency response and efficiency of the transducer in conventional and collapse regimes, experimental results show that a collapsed membrane can be used to generate and detect ultrasound more efficiently than a membrane operated in the conventional mode. Furthermore, the center frequency of the collapsed membrane can be changed by varying the applied DC voltage. In this study, the center frequency of a collapsed transducer in immersion is shown to vary from 20 MHz to 28 MHz with applied DC bias; the same transducer operates at 10 MHz in the conventional mode. In conventional mode, the maximum peak-to-peak pressure is 370 kPa on the transducer surface for a 40-ns, 25-V unipolar pulse excitation. In collapse mode, a 25-ns, 25-V unipolar pulse generates 590 kPa pressure at the surface of the transducer.  相似文献   

2.
A 1-D dual-electrode CMUT array for intracardiac echocardiography (ICE) with a center frequency of 8 MHz has been designed, fabricated, and used to demonstrate the potential of dual-electrode CMUTs. Using a dual-electrode CMUT, 9 dB higher receive signal level is obtained over the 6 dB fractional bandwidth as compared with a conventional CMUT with an identical center electrode biased close to its collapse voltage. Because the same device shows a 7.4 dB increase in maximum pressure output, 16.4 dB overall improvement in transduction performance has been achieved as compared with conventional CMUT. A net peak output pressure of 1.6 MPa on the dual-electrode CMUT membrane with tone burst excitation at 12 MHz is also reported. The frequency response of the dual-electrode CMUT is similar to that of a conventional CMUT with the same membrane geometry with about 15% increase in the center frequency. Monostatic operation of dual-electrode CMUTs shows that the high performance of the transducer is applicable in typical pulse-echo imaging mode of operation. With dynamic shaping of the CMUT membrane to optimize the transmit-and-receive modes of operation separately during each pulse-echo cycle, dual-electrode CMUT is a highly competitive alternative to its piezoelectric counterparts.  相似文献   

3.
Capacitive micromachined ultrasonic transducers (cMUTs) were developed to meet the demands of the ultrasonic industry. To achieve maximum efficiency, the conventional operation of the cMUT requires a bias voltage close to the collapse voltage. Total acoustic output pressure is limited by the efficiency of the cMUT and the maximum-allowed pulse voltage on the membrane. In this paper, we propose the collapse-snapback operation of the cMUT: the membrane is collapsed onto the substrate in the collapsing cycle, and released in the snapback cycle. The collapse-snapback operation overcomes the above-mentioned limitations of the conventional operation. The collapse-snapback operation utilizes a larger range of membrane deflection profiles (both collapsed and released profiles) and generates higher acoustic output pressures. The static finite element calculations were performed to design cMUTs with specific collapse and snapback voltages by changing the electrode parameters (radius (re), position (de), and thickness (te)). These designs were refined for optimum average displacement per cycle. An electrode radius greater than 60% of the membrane radius significantly improved the displacement per volt. Moderately thick membranes (te approximately 0.2 microm) were preferred, as thicker membranes reduced the displacement per volt. Under proper bias conditions, the collapse-snapback operation, designed for high-power transmission, allowed the application of pulse voltages larger than the difference of collapse and snapback voltages. Dynamic finite element calculations of an infinite cMUT array on the substrate loaded with acoustic fluid medium were performed to determine the dynamic response of the cMUT. Commercially available FEM packages ANSYS and LS-DYNA were used for static and dynamic calculations, respectively. The cMUTs were fabricated for optimal performance in the collapse-snapback operation. The transmit experiments were performed on a 2-D cMUT array using a calibrated hydrophone. Taking into account the attenuation and diffraction losses, the pressure on the cMUT surface was extracted. The cMUT generated 0.47 MPa (6 kPa/V) and 1.04 MPa (11 kPa/V) in the conventional and collapse-snapback operations, respectively. Therefore, collapse-snapback operation of the cMUTs was superior for high-power transmission.  相似文献   

4.
A new regime for operating capacitive micromachined ultrasonic transducers   总被引:2,自引:0,他引:2  
We report on a new operation regime for capacitive micromachined ultrasonic transducers (cMUTs). Traditionally, cMUTs are operated at a bias voltage lower than the collapse voltage of their membranes. In the new proposed operation regime, first the cMUT is biased past the collapse voltage. Second, the bias voltage applied to the collapsed membrane is reduced without releasing the membrane. Third, the cMUT is excited with an ac signal at the bias point, keeping the total applied voltage between the collapse and snapback voltages. In this operation regime, the center of the membrane is always in contact with the substrate. Our finite element methods (FEM) calculations reveal that a cMUT operating in this new regime, between collapse and snapback voltages, possesses a coupling efficiency (k/sub T//sup 2/) higher than a cMUT operating in the conventional regime below its collapse voltage. This paper compares the simulation results of the coupling efficiencies of cMUTs operating in conventional and new operation regimes.  相似文献   

5.
Capacitive micromachined ultrasonic transducers (CMUTs) have been introduced as a promising technology for ultrasound imaging and therapeutic ultrasound applications which require high transmitted pressures for increased penetration, high signal-to-noise ratio, and fast heating. However, output power limitation of CMUTs compared with piezoelectrics has been a major drawback. In this work, we show that the output pressure of CMUTs can be significantly increased by deep-collapse operation, which utilizes an electrical pulse excitation much higher than the collapse voltage. We extend the analyses made for CMUTs working in the conventional (uncollapsed) region to the collapsed region and experimentally verify the findings. The static deflection profile of a collapsed membrane is calculated by an analytical approach within 0.6% error when compared with static, electromechanical finite element method (FEM) simulations. The electrical and mechanical restoring forces acting on a collapsed membrane are calculated. It is demonstrated that the stored mechanical energy and the electrical energy increase nonlinearly with increasing pulse amplitude if the membrane has a full-coverage top electrode. Utilizing higher restoring and electrical forces in the deep-collapsed region, we measure 3.5 MPa peak-to-peak pressure centered at 6.8 MHz with a 106% fractional bandwidth at the surface of the transducer with a collapse voltage of 35 V, when the pulse amplitude is 160 V. The experimental results are verified using transient FEM simulations.  相似文献   

6.
Forward-viewing CMUT arrays for medical imaging   总被引:3,自引:0,他引:3  
This paper reports the design and testing of forward-viewing annular arrays fabricated using capacitive micromachined ultrasonic transducer (CMUT) technology. Recent research studies have shown that CMUTs have broad frequency bandwidth and high-transduction efficiency. One- and two-dimensional CMUT arrays of various sizes already have been fabricated, and their viability for medical imaging applications has been demonstrated. We fabricated 64-element, forward-viewing annular arrays using the standard CMUT fabrication process and carried out experiments to measure the operating frequency, bandwidth, and transmit/receive efficiency of the array elements. The annular array elements, designed for imaging applications in the 20 MHz range, had a resonance frequency of 13.5 MHz in air. The immersion pulse-echo data collected from a plane reflector showed that the devices operate in the 5-26 MHz range with a fractional bandwidth of 135%. The output pressure at the surface of the transducer was measured to be 24 kPa/V. These values translate into a dynamic range of 131.5 dB for 1-V excitation in 1-Hz bandwidth with a commercial low noise receiving circuitry. The designed, forward-viewing annular CMUT array is suitable for mounting on the front surface of a cylindrical catheter probe and can provide Doppler information for measurement of blood flow and guiding information for navigation through blood vessels in intravascular ultrasound imaging.  相似文献   

7.
Crosstalk is the coupling of energy between the elements of an ultrasonic transducer array. This coupling degrades the performance of transducers in applications such as medical imaging and therapeutics. In this paper, we present an experimental demonstration of guided interface waves in capacitive micromachined ultrasonic transducers (CMUTs). We compare the experimental results to finite element calculations using a commercial package (LS-DYNA) for a 1-D CMUT array operating in the conventional and collapsed modes. An element in the middle of the array was excited with a unipolar voltage pulse, and the displacements were measured using a laser interferometer along the center line of the array elements immersed in soybean oil. We repeated the measurements for an identical CMUT array covered with a 4.5-microm polydimethylsiloxane (PDMS) layer. The main crosstalk mechanism is the dispersive guided modes propagating in the fluid-solid interface. Although the transmitter element had a center frequency of 5.8 MHz with a 130% fractional bandwidth in the conventional operation, the dispersive guided mode was observed with the maximum amplitude at a frequency of 2.1 MHz, and had a cut-off frequency of 4 MHz. In the collapsed operation, the dispersive guided mode was observed with the maximum amplitude at a frequency of 4.0 MHz, and had a cut-off frequency of 10 MHz. Crosstalk level was lower in the collapsed operation (-39 dB) than in the conventional operation (-24.4 dB). The coverage of the PDMS did not significantly affect the crosstalk level, but reduced the phase velocity for both operation modes. Lamb wave modes, A0 and S0, were also observed with crosstalk levels of -40 dB and -65 dB, respectively. We observed excellent agreement between the finite element and the experimental results.  相似文献   

8.
In this paper, we introduce capacitive micro-machined ultrasonic transducers (CMUTs) with electrically isolated multiple electrodes embedded in the same silicon nitride CMUT membrane. Some of the advantages of this structure are demonstrated using a dual-electrode CMUT with separate transmit and receive electrodes as an example. By locating the transmit electrodes near the edges of a rectangular CMUT membrane, the stable displacement range, hence the maximum pressure amplitude during transmit mode is increased without collapsing the membrane when operated within static collapse voltage range. In the receive mode, the center receive electrode is brought closer to the substrate by biasing the side electrodes, and a higher electromechanical transformer ratio is obtained at low direct current (DC) bias. Therefore, dual-electrode CMUT has an effectively larger gap as compared to conventional CMUT during transmit, and it has an effectively smaller gap during receive. Demonstrative experiments are performed on dual-electrode CMUTs with rectangular membranes with different side and center electrode sizes for transmit and receive measurements. By using the two 4-microm wide side electrodes and an 8-microm wide center electrode on a 20-microm wide membrane, a 6.8 dB increase in maximum output pressure is obtained with side electrode excitation as compared to conventional center electrode. Similarly, the receive performance improvement was demonstrated while reducing the DC bias requirements. Simple finite-element and equivalent circuit-based models were developed to successfully model the behavior of dual-electrode CMUTs. Simulations show that, with simple modifications, more than 10 dB overall sensitivity improvement is feasible with dual-electrode CMUTs with rectangular membranes.  相似文献   

9.
The nonlinear relationship between the electrical input signal and electrostatic force acting on the capacitive micromachined ultrasonic transducer (CMUT) membrane limits its harmonic imaging performance. Several input shaping methods were proposed to compensate for the nonlinearity originating from the electrostatic force's dependence on the square of the applied voltage. Here, we analyze harmonic generation in CMUTs with a time-domain model. The model explains the basis of the input shaping methods and suggests that the nonlinearity resulting from gap dependence of the electrostatic force is also significant. It also suggests that the harmonic distortion in the output pressure can be eliminated by subharmonic ac-only excitation of the CMUT in addition to scaling the input voltage with the instantaneous gap. This gap feedback configuration can be approximated by the simple addition of a series impedance to the CMUT capacitance. We analyze several types of series impedance feedback topologies for gap feedback linearization. We show that for subharmonic ac excitation, although resistive and capacitive impedances result in a trade-off between input voltage and harmonic distortion for a desired pressure output, harmonic generation can be suppressed while increasing the Pa/V transmit sensitivity for proper series inductance and resistance feedback. We experimentally demonstrate the feedback method by reducing harmonic generation by 10 dB for the same output pressure at the fundamental frequency by using a simple series resistor feedback with a CMUT operating at a center frequency of 3 MHz. The proposed methods also allow for utilization of the full CMUT gap for transmit operation and, hence, should be useful in high-intensity ultrasonic applications in addition to harmonic imaging.  相似文献   

10.
This paper describes a correction and an extension in the previously published large signal equivalent circuit model for a circular capacitive micromachined ultrasonic transducer (CMUT) cell. The force model is rederived so that the energy and power is preserved in the equivalent circuit model. The model is able to predict the entire behavior of CMUT until the membrane touches the substrate. Many intrinsic properties of the CMUT cell, such as the collapse condition, collapse voltage, the voltage-displacement interrelation and the force equilibrium before and after collapse voltage in the presence of external static force, are obtained as a direct consequence of the model. The small signal equivalent circuit for any bias condition is obtained from the large signal model. The model can be implemented in circuit simulation tools and model predictions are in excellent agreement with finite element method simulations.  相似文献   

11.
Capacitive micromachined ultrasonic transducers (CMUTs) have great potential to compete with piezoelectric transducers in high-power applications. As the output pressures increase, nonlinearity of CMUT must be reconsidered and optimization is required to reduce harmonic distortions. In this paper, we describe a design approach in which uncollapsed CMUT array elements are sized so as to operate at the maximum radiation impedance and have gap heights such that the generated electrostatic force can sustain a plate displacement with full swing at the given drive amplitude. The proposed design enables high output pressures and low harmonic distortions at the output. An equivalent circuit model of the array is used that accurately simulates the uncollapsed mode of operation. The model facilities the design of CMUT parameters for high-pressure output, without the intensive need for computationally involved FEM tools. The optimized design requires a relatively thick plate compared with a conventional CMUT plate. Thus, we used a silicon wafer as the CMUT plate. The fabrication process involves an anodic bonding process for bonding the silicon plate with the glass substrate. To eliminate the bias voltage, which may cause charging problems, the CMUT array is driven with large continuous wave signals at half of the resonant frequency. The fabricated arrays are tested in an oil tank by applying a 125-V peak 5-cycle burst sinusoidal signal at 1.44 MHz. The applied voltage is increased until the plate is about to touch the bottom electrode to get the maximum peak displacement. The observed pressure is about 1.8 MPa with -28 dBc second harmonic at the surface of the array.  相似文献   

12.
The electromechanical coupling coefficient is an important figure of merit of ultrasonic transducers. The transducer bandwidth is determined by the electromechanical coupling efficiency. The coupling coefficient is, by definition, the ratio of delivered mechanical energy to the stored total energy in the transducer. In this paper, we present the calculation and measurement of coupling coefficient for capacitive micromachined ultrasonic transducers (CMUTs). The finite element method (FEM) is used for our calculations, and the FEM results are compared with the analytical results obtained with parallel plate approximation. The effect of series and parallel capacitances in the CMUT also is investigated. The FEM calculations of the CMUT indicate that the electromechanical coupling coefficient is independent of any series capacitance that may exist in the structure. The series capacitance, however, alters the collapse voltage of the membrane. The parallel parasitic capacitance that may exist in a CMUT or is external to the transducer reduces the coupling coefficient at a given bias voltage. At the collapse, regardless of the parasitics, the coupling coefficient reaches unity. Our experimental measurements confirm a coupling coefficient of 0.85 before collapse, and measurements are in agreement with theory.  相似文献   

13.
The radiation impedance of a capacitive micromachined ultrasonic transducer (CMUT) array is a critical parameter to achieve high performance. In this paper, we present a calculation of the radiation impedance of collapsed, clamped, circular CMUTs both analytically and using finite element method (FEM) simulations. First, we model the radiation impedance of a single collapsed CMUT cell analytically by expressing its velocity profile as a linear combination of special functions for which the generated pressures are known. For an array of collapsed CMUT cells, the mutual impedance between the cells is also taken into account. The radiation impedances for arrays of 7, 19, 37, and 61 circular collapsed CMUT cells for different contact radii are calculated both analytically and by FEM simulations. The radiation resistance of an array reaches a plateau and maintains this level for a wide frequency range. The variation of radiation reactance with respect to frequency indicates an inductance-like behavior in the same frequency range. We find that the peak radiation resistance value is reached at higher kd values in the collapsed case as compared with the uncollapsed case, where k is the wavenumber and d is the center-to-center distance between two neighboring CMUT cells.  相似文献   

14.
This paper describes the design of CMOS receiver electronics for monolithic integration with capacitive micromachined ultrasonic transducer (CMUT) arrays for highfrequency intravascular ultrasound imaging. A custom 8-inch (20-cm) wafer is fabricated in a 0.35-μm two-poly, four-metal CMOS process and then CMUT arrays are built on top of the application specific integrated circuits (ASICs) on the wafer. We discuss advantages of the single-chip CMUT-on-CMOS approach in terms of receive sensitivity and SNR. Low-noise and high-gain design of a transimpedance amplifier (TIA) optimized for a forward-looking volumetric-imaging CMUT array element is discussed as a challenging design example. Amplifier gain, bandwidth, dynamic range, and power consumption trade-offs are discussed in detail. With minimized parasitics provided by the CMUT-on-CMOS approach, the optimized TIA design achieves a 90 fA/√Hz input-referred current noise, which is less than the thermal-mechanical noise of the CMUT element. We show successful system operation with a pulseecho measurement. Transducer-noise-dominated detection in immersion is also demonstrated through output noise spectrum measurement of the integrated system at different CMUT bias voltages. A noise figure of 1.8 dB is obtained in the designed CMUT bandwidth of 10 to 20 MHz.  相似文献   

15.
In this paper, we report measurement results on dual-electrode CMUT demonstrating electromechanical coupling coefficient (k2) of 0.82 at 90% of collapse voltage as well as 136% 3 dB one-way fractional bandwidth at the transducer surface around the design frequency of 8 MHz. These results are within 5% of the predictions of the finite element simulations. The large bandwidth is achieved mainly by utilizing a non-uniform membrane, introducing center mass to the design, whereas the dual-electrode structure provides high coupling coefficient in a large dc bias range without collapsing the membrane. In addition, the non-uniform membrane structure improves the transmit sensitivity of the dual-electrode CMUT by about 2dB as compared with a dual electrode CMUT with uniform membrane.  相似文献   

16.
17.
Forward-viewing ring arrays can enable new applications in intravascular and intracardiac ultrasound. This work presents compelling, full-synthetic, phased-array volumetric images from a forward-viewing capacitive micromachined ultrasonic transducer (CMUT) ring array wire bonded to a custom integrated circuit front end. The CMUT ring array has a diameter of 2 mm and 64 elements each 100 microm x 100 microm in size. In conventional mode, echo signals received from a plane reflector at 5 mm had 70% fractional bandwidth around a center frequency of 8.3 MHz. In collapse mode, 69% fractional bandwidth is measured around 19 MHz. Measured signal-to-noise ratio (SNR) of the echo averaged 16 times was 29 dB for conventional operation and 35 dB for collapse mode. B-scans were generated of a target consisting of steel wires 0.3 mm in diameter to determine resolution performance. The 6 dB axial and lateral resolutions for the B-scan of the wire target are 189 microm and 0.112 radians for 8 MHz, and 78 microm and 0.051 radians for 19 MHz. A reduced firing set suitable for real-time, intravascular applications was generated and shown to produce acceptable images. Rendered three-dimensional (3-D) images of a Palmaz-Schatz stent also are shown, demonstrating that the imaging quality is sufficient for practical applications.  相似文献   

18.
We report on a capacitive micromachined ultrasonic transducer (CMUT) featuring isolation posts (PostCMUT) as a solution to the charging problems caused by device fabrication and operation. This design improves the device reliability. The PostCMUTs were fabricated using a newly developed process based on the wafer-bonding technique. Paired tests showed the superior reliability characteristics of the PostCMUT design compared to those of conventional CMUT designs. No deleterious effect of the new design was seen in preliminary ultrasonic tests or in process yield. PostCMUTs, a design that serves as a solution to the aforementioned reliability problem, constitutes a major contribution to CMUT commercialization.  相似文献   

19.
Capacitive detection limits the performance of capacitive micromachined ultrasonic transducers (CMUTs) by providing poor sensitivity below megahertz frequencies and limiting acoustic power output by imposing constraints on the membrane-substrate gap height. In this paper, an integrated optical interferometric detection method for CMUTs, which provides high displacement sensitivity independent of operation frequency and device capacitance, is reported. The method also enables optoelectronics integration in a small volume and provides optoelectronic isolation between transmit and receive electronics. Implementation of the method involves fabricating CMUTs on transparent substrates and shaping the electrode under each individual CMUT membrane in the form of an optical diffraction grating. Each CMUT membrane thus forms a phase-sensitive optical diffraction grating structure that is used to measure membrane displacements down to 2/spl times/10/sup -4/ /spl Aring///spl radic/Hz level in the dc to 2-MHz range. Test devices are fabricated on quartz substrates, and ultrasonic array imaging in air is performed using a single 4-mm square CMUT consisting of 19/spl times/19 array of membranes operating at 750 kHz.  相似文献   

20.
We report on the characterization of 1D arrays of capacitive micromachined ultrasonic transducers (cMUT). A 275×5600 μm 1D CMUT array element is experimentally characterized, and the results are found to be in agreement with theoretical predictions. As a receiver, the transducer has a 0.28-fm/√Hz displacement sensitivity, and, as a transmitter, it produces 5 kPa/V of output pressure at the transducer surface at 3 MHz with a DC bias of 35 V. The transducer has more than 100% fractional bandwidth around 3 MHz, which makes it suitable for ultrasound imaging. The radiation pattern of isolated single elements, as well as those of array elements are measured, and two major sources of acoustical crosstalk are identified. A weakly dispersive non-leaky interface wave (Stoneley wave) is observed to be propagating at the silicon substrate-fluid interface at a speed close to the speed of sound in the fluid. This wave causes internal reflections, spurious resonance, and radiation from the edges of the silicon substrate. The large lateral component of the particle velocity generated by the membranes at the edge of the cMUT array elements is found to be the source of this interface wave. Lowest order Lamb waves in the silicon substrate are also found to contribute to the crosstalk between elements. These waves are excited at the edges of individual vibrating membranes, where they are anchored to the substrate, and result in a narrowing of the beam profile of the array elements. Several methods, such as trench isolation and wafer thinning, are proposed and implemented to modify the acoustical cross coupling between array elements  相似文献   