首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The design and fabrication procedures for implementing a high-density (16-microm center spacing) single-mode fiber (SMF) array are described. The specific application for this array is a parallel optical coherence tomography system for endoscopic imaging. We obtained fiber elements by etching standard single-mode SMF-28 fibers to a diameter of 14-15 microm. We equalized 1-m lengths of fiber to within 1 mm by using a fiber interferometer setup, and we describe a method for packaging arrays with as many as 100 fibers.  相似文献   

2.
We have developed a compact, multimodal instrument for simultaneous acquisition of en face quasi-confocal fundus images and adaptive-optics (AO) spectral-domain optical coherence tomography (SDOCT) cross-sectional images. The optical system including all AO and SDOCT components occupies a 60x60 cm breadboard that can be readily transported for clinical applications. The AO component combines a Hartmann-Shack wavefront sensor and a microelectromechanical systems-based deformable mirror to sense and correct ocular aberrations at 15 Hz with a maximum stroke of 4 microm. A broadband superluminescent diode source provides 4 mum depth resolution for SDOCT imaging. In human volunteer testing, we observed up to an 8 dB increase in OCT signal and a corresponding lateral resolution of <10 microm as a result of AO correction.  相似文献   

3.
Techniques for high-speed delay scanning are important for low-coherence interferometry, optical coherence tomography, pump probe measurements, and other applications. We demonstrate a novel scanning delay line using a multiple-pass cavity. Differential delays are accumulated with each pass so that millimeter delays can be generated with tens of micrometer mirror displacements. With special design criteria, misalignment sensitivity can be dramatically reduced. The system is demonstrated to scan 6 m/s at 2-kHz repetition rates. Real-time optical coherence tomography imaging with 500 pixel images at four frames/s is performed. Using a Cr:forsterite laser source, we obtained axial image resolutions of 6 microm with 92-dB sensitivity.  相似文献   

4.
Meemon P  Lee KS  Murali S  Rolland J 《Applied optics》2008,47(13):2452-2457
The optical system design of a dynamic focus endoscopic probe for optical coherence tomography is reported. The dynamic focus capability is based on a liquid lens technology that provides variable focus by changing its curvatures in response to an electric field variation. The effects of a cylindrical exit window present, in practice, for a catheter were accounted for. Degradation in image quality caused by this window was corrected to get diffraction limited imaging performance. As a result, the dynamically focusing catheter with a lateral resolution ranging from 4 to 6 mum through an approximately 5 mm imaging distance was designed without mechanically refocusing the system.  相似文献   

5.
A confocal reflectance theta line-scanning microscope demonstrates imaging of nuclear and cellular morphology in human skin and oral mucosa in vivo. The illumination and detection are through a divided objective lens pupil, resulting in a theta-microscope configuration. A line is directly scanned in the pupil and descanned onto a linear detector array such that the theta line scanner consists of only seven main optical components. The experimentally measured lateral resolution is 1.0 microm and optical section thickness is 1.7 microm under nominal conditions at 830 nm wavelength. Through full-thickness human epidermis (i.e., in the dermis) the measured lateral resolution is 1.7 microm and the optical section thickness is 9.2 microm. The lateral resolution, sectioning, and image quality in epidermal (epithelial) tissue is comparable to that of point scanning confocal microscopy.  相似文献   

6.
Xie T  Xie H  Fedder GK  Pan Y 《Applied optics》2003,42(31):6422-6426
Experimental results of a modified micromachined microelectromechanical systems (MEMS) mirror for substantial enhancement of the transverse laser scanning performance of endoscopic optical coherence tomography (EOCT) are presented. Image distortion due to buckling of MEMS mirror in our previous designs was analyzed and found to be attributed to excessive internal stress of the transverse bimorph meshes. The modified MEMS mirror completely eliminates bimorph stress and the resultant buckling effect, which increases the wobbling-free angular optical actuation to greater than 37 degrees, exceeding the transverse laser scanning requirements for EOCT and confocal endoscopy. The new optical coherence tomography (OCT) endoscope allows for two-dimensional cross-sectional imaging that covers an area of 4.2 mm x 2.8 mm (limited by scope size) and at roughly 5 frames/s instead of the previous area size of 2.9 mm x 2.8 mm and is highly suitable for noninvasive and high-resolution imaging diagnosis of epithelial lesions in vivo. EOCT images of normal rat bladders and rat bladder cancers are compared with the same cross sections acquired with conventional bench-top OCT. The results clearly demonstrate the potential of EOCT for in vivo imaging diagnosis and precise guidance for excisional biopsy of early bladder cancers.  相似文献   

7.
Zu Y  Ding Z  Zhou J  Lee Y  Bard AJ 《Analytical chemistry》2001,73(10):2153-2156
Electrogenerated chemiluminescence at electrodes with effective diameters down to 155 nm was used as a stable light source for near-field scanning optical microscopy imaging of an interdigitated array and a submicrometer size test substrate. Light was generated in a thin (approximately 500 microm) layer of an aqueous solution of 15 mM Ru(bpy)3(2+) and 100 mM tri-n-propylamine in a pH 7.5 buffer. The resolution obtained was compared to that found with a micrometer size electrode. The shear force from the tip attached to a quartz tuning fork was used to monitor and control the tip-to-substrate separation within the near field regime.  相似文献   

8.
Liu L  Chen NG 《Applied optics》2006,45(21):5426-5431
We have developed a fast scanning optical delay line based on a rotary mirror array. A double-pass configuration is adopted to optimize the fiber-optical coupling and thus minimize the amplitude modulation in the reflected light. The achieved scanning range is extended to over 3 mm. An additional Michelson interferometer is incorporated into the reference arm to achieve high delay repeatability. Such a device is ideal for real-time optical coherence tomography, optical Doppler tomography, and spectroscopic optical coherence tomography.  相似文献   

9.
Wide-field optical coherence tomography: imaging of biological tissues   总被引:2,自引:0,他引:2  
We describe a two-dimensional optical coherence tomography technique with which we were able to obtain multiple longitudinal slices of a biological sample directly in a single Z scan. The system is based on a femtosecond Cr4+:forsterite laser and an infrared camera for wide-field imaging of the sample with a depth resolution of 5 microm. With this imaging apparatus we were able to investigate human skin and mouse ear samples and to observe the different constitutive tissues.  相似文献   

10.
Ryu SY  Choi HY  Na J  Choi WJ  Lee BH 《Applied optics》2008,47(10):1510-1516
We demonstrate a compact all-fiber sampling probe for an optical coherence tomography (OCT) system. By forming a focusing lens directly on the tip of an optical fiber, a compact sampling probe could be implemented. To simultaneously achieve a sufficiently long working distance and a good lateral resolution, we employed a large-mode area photonic crystal fiber (PCF) and a coreless silica fiber (CSF) of the same diameters. A working distance of up to 1270 microm, a 3 dB distance range of 2210 microm, and a transverse resolution of 14.2 microm were achieved with the implemented PCF lensed fiber; these values are comparable to those obtainable with a conventional objective lens having an NA of 0.25 (10 x). The performance of the OCT system equipped with the proposed PCF lensed fiber is presented by showing the OCT images of a rat finger as a biological sample and a pearl as an in-depth sample.  相似文献   

11.
Sato M  Wakaki I  Watanabe Y  Tanno N 《Applied optics》2005,44(13):2471-2481
We describe the fundamental characteristics of a synthesized light source (SLS) consisting of two low-coherence light sources to enhance the spatial resolution for optical coherence tomography (OCT). The axial resolution of OCT is given by half the coherence length of the light source. We fabricated a SLS with a coherence length of 2.3 microm and a side-lobe intensity of 45% with an intensity ratio of LED1:LED2 = 1:0.5 by combining two light sources, LED1, with a central wavelength of 691 nm and a spectral bandwidth of 99 nm, and LED2, with a central wavelength of 882 nm and a spectral bandwidth of 76 nm. The coherence length of 2.3 microm was 56% of the shorter coherence length in the two LEDs, which indicates that the axial resolution is 1.2 microm. The lateral resolution was measured at less than 4.4 microm by use of the phase-shift method and with a test pattern as a sample. The measured rough surfaces of a coin are illustrated and discussed.  相似文献   

12.
郑羽  李刚  吴开杰  张泰石  林凌  刘晶晶 《光电工程》2007,34(10):73-77,107
为了提高复杂多层样品层析图像的分辨率,构建了复谱频域光学相干层析成像(CSOCT)系统.由于其在低亮度和高速成像方面相对于时域OCT具有更高的灵敏度,因此在光学相干层析成像系统中具有重要的作用.本文对测试样品二层盖波片进行成像实验,基于光学相干层析基本理论,采用五帧相移算法,最终获得测试样品的复谱频域OCT图像.实验结果表明,该系统可以消除谱频域OCT图像中的寄生项和镜像,改善和提高层析图像的分辨率.  相似文献   

13.
14.
Broadband light generation from a single-mode optical fiber was developed for high-resolution optical coherence tomography (OCT). No noise amplification was observed for light broadened by self-phase modulation. The investigation showed that the intensity noise of light broadened by self-phase modulation in a single-mode optical fiber was much lower than that of continuum light from a microstructure fiber (MSF). The spectral width of a femtosecond input laser pulse was successfully broadened by a factor of 11, and a coherence length of 3.7 microm was achieved with this source. The application of light broadened by a single-mode optical fiber and MSF was compared for use in OCT imaging. The results showed that a single-mode fiber with a small core diameter is a useful way to generate low-noise, broadband light for high-resolution OCT imaging.  相似文献   

15.
通过分析眼科光学相干层析设备的成像分辨率理论计算模型,设计并研制了一套用于测量其光源光谱和系统数值孔径的小型化检测装置。针对一台商业化的临床在用眼科光学相干层析设备,通过对其关键参数的测量,得到该设备的纵向分辨率为6.9μm,横向分辨率为42.3μm。该检测装置未来可作为眼科光学相干层析设备的质控与计量器具。  相似文献   

16.
Wang Y  Wang RK 《Applied optics》2007,46(27):6815-6820
A new optical system for transmission optical projection tomography (TOPT) is presented to reduce the divergence of the projection data from the true parallel projections. This is performed by introducing an iris at the back focus of the objective lens. The influence of the defocusing on TOPT is demonstrated by computational simulations and experiments. We compare the performances of the new and conventional TOPT systems in order to optimize the optical system for three-dimensional imaging of the embryos of small animals. The optimal imaging performance is given by the new system with numerical apertures between 0.007 and 0.014, with which the spatial resolution of 25 microm is achieved. The optimal configuration is validated by TOPT of a phantom sample and a fixed five-day chick embryo.  相似文献   

17.
We demonstrate, what is to the best of our knowledge, a novel optical tomographic method for the visualization of the inner structure of scattering media such as biological tissue in the near-infrared region. We constructed a scanning confocal imaging system with a cross-axes arrangement using optical fibers. This system is based on the optical heterodyne technique and enables the detection of very weak coherence photons that are generated in the spatially restricted confocal region and scattered laterally (90 degrees ) against an incident beam. To evaluate the fundamental imaging capabilities of the system, we assessed measurements from scattering phantoms composed of an Intralipid suspension with varying volume concentrations. The results of this study demonstrate that the right-angled scattered light adheres to the Lambert-Beer law and that the present system can detect light propagating through a distance of approximately 31l of the mean free path. An inclusion as small as 100 microm can be discriminated in a scattering media with an optical thickness of 4. We investigated the potential of the proposed system for imaging biological tissues in preliminary experiments using samples of chicken breast tissue.  相似文献   

18.
Mao Y  Chang S  Sherif S  Flueraru C 《Applied optics》2007,46(23):5887-5894
The quality and parameters of probing optical beams are extremely important in biomedical imaging systems both for image quality and light coupling efficiency considerations. For example, the shape, size, focal position, and focal range of such beams could have a great impact on the lateral resolution, penetration depth, and signal-to-noise ratio of the image in optical coherence tomography. We present a beam profile characterization of different variations of graded-index (GRIN) fiber lenses, which were recently proposed for biomedical imaging probes. Those GRIN lens modules are made of a single mode fiber and a GRIN fiber lens with or without a fiber spacer between them. We discuss theoretical analysis methods, fabrication techniques, and measured performance compared with theory.  相似文献   

19.
A broadband all-optical ultrasound transducer has been designed, fabricated, and evaluated for high- frequency ultrasound imaging. The device consists of a 2-D gold nanostructure imprinted on top of a glass substrate, followed by a 3 microm PDMS layer and a 30 nm gold layer. A laser pulse at the resonance wavelength of the gold nanostructure is focused onto the surface for ultrasound generation, while the gold nanostructure, together with the 30 nm thick gold layer and the PDMS layer in between, forms an etalon for ultrasound detection, which uses a CW laser at a wavelength far from resonance as the probing beam. The center frequency of a pulse-echo signal recorded in the far field of the transducer is 40 MHz with -6 dB bandwidth of 57 MHz. The signal to noise ratio (SNR) from a 70 microm diameter transmit element combined with a 20 microm diameter receive element probing a near perfect reflector positioned 1.5 mm from the transducer surface is more than 10 dB and has the potential to be improved by at least another 40 dB. A high-frequency ultrasound array has been emulated using multiple measurements from the transducer while mechanically scanning an imaging target. Characterization of the device's optical and acoustical properties, as well as preliminary imaging results, strongly suggest that all-optical ultrasound transducers can be used to build high-frequency arrays for real-time high-resolution ultrasound imaging.  相似文献   

20.
Lee Y  Bard AJ 《Analytical chemistry》2002,74(15):3626-3633
A technique that combines scanning electrochemical microscopy (SECM) and optical microscopy (OM) was implemented with a new probe tip. The tip for scanning electrochemicaVoptical microscopy (SECM/OM) was constructed by insulating a typical gold-coated near-field scanning optical microscopy tip using electrophoretic anodic paint. Once fabricated, the tip was characterized by steady-state cyclic voltammetry, as well as optical and electrochemical approach experiments. This tip generated a stable steady-state current and well-defined SECM approach curves for both conductive and insulating substrates. Durable tips whose geometry was a ring with < 1 microm as outer ring radius could be consistently fabricated. Simultaneous electrochemical and optical images of an interdigitated array electrode were obtained with a resolution on the micrometer scale, demonstrating good performance of the tip as both an optical and an electrochemical probe for imaging microstructures. The SECM feedback current measurements were successfully employed to determine tip-substrate distances for imaging.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号