首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
M. El‐Shimy 《风能》2014,17(2):279-295
The analysis of reactive power for offshore and onshore wind farms connected to the grid through high‐voltage alternating‐current transmission systems is considered in this paper. The considered wind farm is made up with doubly fed induction generators (DFIGs). Modeling and improved analysis of the effective reactive power capability of DFIGs are provided. Particularly, the optimal power‐tracking constraints and other operational variables are considered in the modeling and analysis of the DFIG reactive power capability. Reactive power requirements for both overhead and cable transmission systems are modeled and compared with each other as well as with the reactive power capability of the wind farms. Possibility of unity power factor operation suggested by the German Electricity Association (VDEW) is investigated for both types of installations. Aggregate reactive power demands on both wind farms are assessed such that the bus voltages remain within an acceptable bandwidth considering various operational limits. The reactive power settings for both types of wind farm installations are determined. In addition, the minimum capacity and reactive power settings for reactive power compensation required for cable‐based installations are determined. Several numerical examples are given to illustrate the reactive power characteristics and capability of DFIGs, performance of transmission lines and reactive power analysis for DFIG‐based grid‐connected wind farms. A summary of the main outcomes of the work presented in this paper is provided in the conclusions section. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

2.
The stability of the electrical grid depends on enough generators being able to provide appropriate responses to sudden losses in generation capacity, increases in power demand or similar events. Within the United States, wind turbines largely do not provide such generation support, which has been acceptable because the penetration of wind energy into the grid has been relatively low. However, frequency support capabilities may need to be built into future generations of wind turbines to enable high penetration levels over approximately 20%. In this paper, we describe control strategies that can enable power reserve by leaving some wind energy uncaptured. Our focus is on the control strategies used by an operating turbine, where the turbine is asked to track a power reference signal supplied by the wind farm operator. We compare the strategies in terms of their control performance as well as their effects on the turbine itself, such as the possibility for increased loads on turbine components. It is assumed that the wind farm operator has access to the necessary grid information to generate the power reference provided to the turbine, and we do not simulate the electrical interaction between the turbine and the utility grid. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

3.
E. Kaempf  M. Braun 《风能》2017,20(7):1291-1309
In power system load flow studies, it is common to ignore wind park (WP) losses completely, since WPs are obliged to provide reactive power as a free‐of‐charge ancillary service. Strongly simplified WP loss estimations are also widespread. Prevailing loss modelling approaches may result in substantial and so far usually ignored reactive power allocation inefficiencies. The innovation of this paper lies in demonstrating this and in presenting an alternative modelling approach that combines speed, ease‐of‐use and accuracy. Calculations are based on a generic WP connected to 110 kV. It is simulated once using gearless permanent magnet synchronous generators and once using doubly fed induction generators. In this way, for the first time, the consequences of neglecting differences between wind generator types when calculating reactive power‐related losses are systematically quantified. Loss‐minimal dispatch is assessed using heuristic optimal power flow. Relevance of findings is demonstrated for the application of reducing system losses based on reactive power control of WPs in closed‐loop optimal power flow schemes. It is shown that non‐consideration of WP losses may lead to dispatch decisions where the increase in WP losses outweighs the achieved loss reduction in the 110 kV system by 400%. The study facilitates comparing reactive power ancillary services from WPs to that of other technologies from an economic perspective. It concludes by a benchmarking overview of pros and cons of modelling alternatives. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

4.
Reactive power management and control of distant large-scale offshore wind power farms connected to the grid through high-voltage alternating current (HVAC) transmission cable are presented in this paper. The choice of the transmission option is based on the capacity of the considered wind farm (WF) and the distance to the onshore grid connection point. The WF is made up of identical doubly-fed induction generators (DFIGs). Modelling and improved analysis of the effective reactive power capability of DFIGs as affected by various operational constraints are provided. In addition, modelling and analysis of the reactive power demands, balance, and control are presented. The minimum capacity and reactive power settings for reactive power compensation required for the system are determined. Possibility of unity power factor operation suggested by the German electricity association (VDEW) is investigated. A summary of the main outcomes of the work presented in this paper is provided in the conclusions section.  相似文献   

5.
论述了风电容量在占局部电网相当比例时,风电机组的无功功率调整与电网电压之间的关系,对于定速和变速风电机组的运行特性做了分析,提出了在需要做无功功率调整时风电机组应能满足的特殊要求。  相似文献   

6.
The aim of this paper is to quantify the cost of the provision of voltage control by wind power generation. A methodology for evaluating the economic impact of providing different types of voltage control is proposed. This evaluation examines the increase in costs caused by the change in active power losses due to the provision of wind farms voltage control. These losses are computed for different controllers: (a) wind farms are operated at a fixed power factor, (b) wind farms provide proportional voltage control, and (c) wind farms provide reactive power to minimize power losses. Furthermore, these three possibilities are compared with the option of adding flexible alternating current transmission system devices, which are another alternative for supporting the grid by controlling voltage. The methodology outlined is applied to a real and representative Spanish wind harvesting network. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

7.
This paper presents a new robust and effective control strategy to mitigate symmetrical voltage dips in a grid‐connected doubly fed induction generator (DFIG) wind energy conversion system without any additional hardware in the system. The aim is to control the power transmitted to the grid so as to keep the electrical and mechanical quantities above their threshold protection values during a voltage dip transient. To achieve this, the references of the powers are readjusted to adapt the wind energy conversion system to the fault conditions. Robust control strategies, combining the merits of sliding mode theory and fuzzy logic, are then proposed in this paper. These controllers are derived from the dynamic model of the DFIG considering the variations in the stator flux generated by the voltage drop. This approach is found to yield better performance than other control design methods which assume the flux in the stator to remain constant in amplitude. This control scheme is compliant with the fault‐ride‐through grid codes which require the wind turbine generator to remain connected during voltage dips. A series of simulation scenarios are carried out on a 3‐MW wind turbine system to demonstrate the effectiveness of the proposed control schemes under voltage dips and parameter uncertainty conditions.  相似文献   

8.
Emphasis in this article is on the design of a co‐ordinated voltage control strategy for doubly fed induction generator (DFIG) wind turbines that enhances their capability to provide grid support during grid faults. In contrast to its very good performance in normal operation, the DFIG wind turbine concept is quite sensitive to grid faults and requires special power converter protection. The fault ride‐through and grid support capabilities of the DFIG address therefore primarily the design of DFIG wind turbine control with special focus on power converter protection and voltage control issues. A voltage control strategy is designed and implemented in this article, based on the idea that both converters of the DFIG (i.e. rotor‐side converter and grid‐side converter) participate in the grid voltage control in a co‐ordinated manner. By default the grid voltage is controlled by the rotor‐side converter as long as it is not blocked by the protection system, otherwise the grid‐side converter takes over the voltage control. Moreover, the article presents a DFIG wind farm model equipped with a grid fault protection system and the described co‐ordinated voltage control. The whole DFIG wind farm model is implemented in the power system simulation toolbox PowerFactory DIgSILENT. The DFIG wind farm ride‐through capability and contribution to voltage control in the power system are assessed and discussed by means of simulations with the use of a transmission power system generic model developed and delivered by the Danish Transmission System Operator Energinet.dk. The simulation results show how a DFIG wind farm equipped with voltage control can help a nearby active stall wind farm to ride through a grid fault, without implementation of any additional ride‐through control strategy in the active stall wind farm. Copyright © 2006 John Wiley &Sons, Ltd.  相似文献   

9.
The power system of Denmark is characterized by significant incorporation of wind power. Presently, more than 20% of the annual electricity consumption is covered by electricity‐producing wind turbines. The largest increase in grid‐incorporated wind power is expected to come from large (offshore) wind farms operating as large wind power plants with ride‐through solutions, connected to the high‐voltage transmission system and providing ancillary services to the system. In Denmark there are presently two offshore wind farms connected to the transmission system: Horns Rev A (160MW rated power in the western part of the country) and Nysted (165MW rated power at Rødsand in Eastern Denmark). The construction of two more offshore wind farms, totalling 400MW by the years 2008–2010, has been announced. This article presents the status, perspectives and technical challenges for wind power in the power system from the point of view of Energinet.dk, Transmission System Operator of Denmark. Copyright © 2006 John Wiley &Sons, Ltd  相似文献   

10.
蔡祯祺  黄民翔  张磊 《能源工程》2010,(5):29-33,46
以笼式异步电机为基础的风力发电机组并网运行时需要吸收大量无功功率,如果不能提供充分的无功补偿,会导致风电场电压跌落,部分风机脱离,系统无法正常运行。而统一潮流控制器(UPFC)具有控制线路潮流,提高电网稳定的作用,可以应用于风电并网之中。针对上述问题,在某一风场内的变风速条件下,用软件MATLAB/simu link建立基于恒速恒频异步发电机的风电机组并网模型并仿真,通过分析仿真结果,对比应用UPFC进行无功补偿前后风电场及电网的运行状态变化,证明UPFC可以调节带有风电场的系统无功功率和电压,维持电网稳定运行。  相似文献   

11.
This article deals with nonlinear model‐based control design for wind turbines. By systematically integrating several mechanical degrees of freedom in the control design model, the load mitigation potential from the proposed multivariable control framework is demonstrated. The application of the linear matrix inequality (LMI)‐based control design is discussed in detail. Apart from the commonly considered power production mode, an extended operating range to provide stabilization of the electrical grid through power tracking is considered. This control functionality allows for an evaluation of the resulting fatigue and ultimate loads for power tracking at different dynamic requirements. The results indicate that under the impact of a dedicated control scheme, this functionality is feasible with respect to the occurring loads and operational behavior of the wind turbine.  相似文献   

12.
There are dozens of studies made and ongoing related to wind integration. However, the results are not easy to compare. IEA WIND R&D Task 25 on ‘Design and Operation of Power Systems with Large Amounts of Wind Power’ collects and shares information on wind generation impacts on power systems, with analyses and guidelines on methodologies. In the state‐of‐the‐art report (October, 2007), and the final report of the 3 years period (July, 2009) the most relevant wind power grid integration studies have been analysed especially regarding methodologies and input data. Several issues that impact on the amount of wind power that can be integrated have been identified. Large balancing areas and aggregation benefits of wide areas help in reducing the variability and forecast errors of wind power as well as help in pooling more cost effective balancing resources. System operation and functioning electricity markets at less than day‐ahead time scales help reduce forecast errors of wind power. Transmission is the key to aggregation benefits, electricity markets and larger balancing areas. Best practices in wind integration studies are described. There is also benefit when adding wind power to power systems: it reduces the total operating costs and emissions as wind replaces fossil fuels and this should be highlighted more in future studies. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

13.
The paper demonstrates the characteristics of wind power variability and net load variability in multiple power systems based on real data from multiple years. Demonstrated characteristics include probability distribution for different ramp durations, seasonal and diurnal variability and low net load events. The comparison shows regions with low variability (Sweden, Spain and Germany), medium variability (Portugal, Ireland, Finland and Denmark) and regions with higher variability (Quebec, Bonneville Power Administration and Electric Reliability Council of Texas in North America; Gansu, Jilin and Liaoning in China; and Norway and offshore wind power in Denmark). For regions with low variability, the maximum 1 h wind ramps are below 10% of nominal capacity, and for regions with high variability, they may be close to 30%. Wind power variability is mainly explained by the extent of geographical spread, but also higher capacity factor causes higher variability. It was also shown how wind power ramps are autocorrelated and dependent on the operating output level. When wind power was concentrated in smaller area, there were outliers with high changes in wind output, which were not present in large areas with well‐dispersed wind power. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

14.
区域电压无功控制系统以电压无功的分级控制思想为指导,在调度自动化主站实现集中的、以保证负荷母线电压质量为首要目标的变电站一级控制;以220kV变电站的供电范围进行动态分区,实现区域内的二级协调控制;以基子全网实时潮流的网损灵敏度对可控设备进行在线寻优,实现准三级控制。二三级拉制中充分地考虑了电网运行的经济性要求。实践表明应用该系统是即时控制电压在合格范围、供应优质电能、降低电力服务成本度降损节能的有效措施。  相似文献   

15.
Wind turbines are typically operated to maximize their performance without considering the impact of wake effects on nearby turbines. Wind plant control concepts aim to increase overall wind plant performance by coordinating the operation of the turbines. This paper focuses on axial‐induction‐based wind plant control techniques, in which the generator torque or blade pitch degrees of freedom of the wind turbines are adjusted. The paper addresses discrepancies between a high‐order wind plant model and an engineering wind plant model. Changes in the engineering model are proposed to better capture the effects of axial‐induction‐based control shown in the high‐order model. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

16.
The high integration of photovoltaic power plants (PVPPs) has started to affect the operation, stability, and security of utility grids. Thus, many countries have established new requirements for grid integration of solar photovoltaics to address the issues in stability and security of the power grid. In this paper, a comprehensive study of the recent international grid codes requirement concerning the penetration of PVPPs into electrical grids is provided. Firstly, the paper discusses the trends of PVPPs worldwide and the significance of improving grid codes' requirements. In addition, the comparison of common requirements covered in the majority of international grid codes considers high‐ and low‐voltage ride‐through capabilities, voltage and frequency regulation, and active and reactive power support requirements. Finally, a broad discussion on the compliance technology challenges and global harmonization of international grid codes that the PVPPs have to address is presented. The study summarizes the most recent international regulation regarding photovoltaic integration and research findings on the compliance of these regulations and proposed recommendations for future research. It also can assist power system operators to compare their existing requirements with other universal operators or establish their own regulations for the first time. Additionally, this research assists photovoltaic manufacturers and developers to get more accurate understanding from the recent global requirements enforced by the modern grid codes.  相似文献   

17.
针对电网三相对称故障条件下风电场电压不稳定的问题,文章提出了一种基于神经元的风储联合系统无功功率自适应控制策略,该策略以风储联合系统公共耦合点(Point of Common Coupling,PCC)的电压和电流为控制器的输入,采用Hebb学习算法作为自适应律,以获得准确的无功补偿。通过动态调整控制器的参数,使储能系统协调风电达到自适应输出无功功率的效果,提高系统在电网故障下的电压稳定性和风电故障穿越能力。最后,利用Matlab/Simulink仿真验证了该控制策略的有效性和正确性,与常规PI控制策略相比,文章所提出的控制策略可使风储系统迅速提供无功功率,PCC点的电压得到明显上升。  相似文献   

18.
This paper presents an optimization‐based control strategy for the power management of a wind farm with battery storage. The strategy seeks to minimize the error between the power delivered by the wind farm with battery storage and the power demand from an operator. In addition, the strategy attempts to maximize battery life. The control strategy has two main stages. The first stage produces a family of control solutions that minimize the power error subject to the battery constraints over an optimization horizon. These solutions are parameterized by a given value for the state of charge at the end of the optimization horizon. The second stage screens the family of control solutions to select one attaining an optimal balance between power error and battery life. The battery life model used in this stage is a weighted Amp‐hour throughput model. The control strategy is modular, allowing for more sophisticated optimization models in the first stage or more elaborate battery life models in the second stage. The strategy is implemented in real time in the framework of model predictive control. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

19.
As the worldwide use of wind turbine generators in utility‐scale applications continues to increase, it will become increasingly important to assess the economic and reliability impact of these intermittent resources. Although the utility industry appears to be moving towards a restructured environment, basic economic and reliability issues will continue to be relevant to companies involved with electricity generation. This article is the second in a two‐part series that addresses modelling approaches and results that were obtained in several case studies and research projects at the National Renewable Energy Laboratory (NREL). This second article focuses on wind plant capacity credit as measured with power system reliability indices. Reliability‐based methods of measuring capacity credit are compared with wind plant capacity factor. The relationship between capacity credit and accurate wind forecasting is also explored. Published in 2000 by John Wiley & Sons, Ltd.  相似文献   

20.
A. Kargarian  M. Raoofat   《Energy》2011,36(5):2565-2571
While wind power generation is growing rapidly around the globe; its stochastic nature affects the system operation in many different aspects. In this paper, the impact of wind power volatility on the reactive power market is taken into account. The paper presents a novel stochastic method for optimal reactive power market clearing considering voltage security and volatile nature of the wind. The proposed optimization algorithm uses a multiobjective nonlinear programming technique to minimize market payment and simultaneously maximize voltage security margin. Considering a set of probable wind speeds, in the first stage, the proposed algorithm seeks to minimize expected system payment which is summation of reactive power payment and transmission loss cost. The object of the second stage is maximization of expected voltage security margin to increase the system loadability and security. Finally, in the last stage, a multiobjective function is presented to schedule the stochastic reactive power market using results of two previous stages. The proposed algorithm is applied to IEEE 14-bus test system. As a benchmark, Monte Carlo Simulation method is utilized to simulate the actual market of given period of time to evaluate results of the proposed algorithm, and satisfactory results are achieved.  相似文献   