首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An image processing algorithm is presented to reconstruct optical pathlength distributions from images of nonabsorbing weak phase objects, obtained by a differential interference contrast (DIC) microscope, equipped with a charge-coupled device camera. The method is demonstrated on DIC images of transparent latex spheres and unstained bovine spermatozoa. The images were obtained with a wide-field DIC microscope, using monochromatic light. After image acquisition, the measured intensities were converted to pathlength differences. Filtering in the Fourier domain was applied to correct for the typical shadow-cast effect of DIC images. The filter was constructed using the lateral shift introduced in the microscope, and parameters describing the spectral distribution of the signal-to-noise ratio. By varying these parameters and looking at the resulting images, an appropriate setting for the filter parameters was found. In the reconstructed image each grey value represents the optical pathlength at that particular location, enabling quantitative analysis of object parameters using standard image processing techniques. The advantage of using interferometric techniques is that measurements can be done on transparent objects, without staining, enabling observations on living cells. Quantitative use of images obtained by a wide-field DIC microscope becomes possible with this technique, using relatively simple means.  相似文献   

2.
The aim of this report is to demonstrate a unified version of microscopy through the use of advanced diffractive optics. The unified scheme derives from the technical possibility of realizing front wave engineering in a wide range of electromagnetic spectrum. The unified treatment is realized through the design and nanofabrication of phase diffractive elements (PDE) through which wave front beam shaping is obtained. In particular, we will show applications, by using biological samples, ranging from micromanipulation using optical tweezers to X-ray differential interference contrast (DIC) microscopy combined with X-ray fluorescence. We report some details on the design and physical implementation of diffractive elements that besides focusing also perform other optical functions: beam splitting, beam intensity, and phase redistribution or mode conversion. Laser beam splitting is used for multiple trapping and independent manipulation of micro-beads surrounding a cell as an array of tweezers and for arraying and sorting microscopic size biological samples. Another application is the Gauss to Laguerre-Gauss mode conversion, which allows for trapping and transfering orbital angular momentum of light to micro-particles immersed in a fluid. These experiments are performed in an inverted optical microscope coupled with an infrared laser beam and a spatial light modulator for diffractive optics implementation. High-resolution optics, fabricated by means of e-beam lithography, are demonstrated to control the intensity and the phase of the sheared beams in x-ray DIC microscopy. DIC experiments with phase objects reveal a dramatic increase in image contrast compared to bright-field x-ray microscopy. Besides the topographic information, fluorescence allows detection of certain chemical elements (Cl, P, Sc, K) in the same setup, by changing the photon energy of the x-ray beam.  相似文献   

3.
A combined optical and atomic force microscope for live cell investigations   总被引:6,自引:0,他引:6  
We present an easy-to-use combination of an atomic force microscope (AFM) and an epi-fluorescence microscope, which allows live cell imaging under physiological conditions. High-resolution AFM images were acquired while simultaneously monitoring either the fluorescence image of labeled membrane components, or a high-contrast optical image (DIC, differential interference contrast). By applying two complementary techniques at the same time, additional information and correlations between structure and function of living organisms were obtained. The synergy effects between fluorescence imaging and AFM were further demonstrated by probing fluorescence-labeled receptor clusters in the cell membrane via force spectroscopy using antibody-functionalized tips. The binding probability on receptor-containing areas identified with fluorescence microscopy ("receptor-positive sites") was significantly higher than that on sites lacking receptors.  相似文献   

4.
There is a need for an electron microscopic method for visualization of selectively stained neurons and neuronal processes with higher resolution than can be obtained with the light microscope, but using thick sections that allow visualization of the three-dimensional structure of the neuron. Such a method is required for measurement of the geometry of neurons, and this information is needed to test theoretical predictions on the way in which electrical signals of synaptic origin are processed by the cells. The high voltage electron microscope (HVEM) is well suited to this application, because of its high resolution and ability to form images of thick sections. Use of this instrument requires development of selective stains that can produce diffuse cytoplasmic staining of specific cells or cell populations on the basis of their functional properties. Several such methods currently being employed for light microscopic work can be used directly in the high voltage electron microscope or can be made useful by relatively minor alterations. These include intracellular staining with horseradish peroxidase, axonal tracing with Phaseolus vulgaris leukoagglutinin (PHA-L), and immunocytochemical staining for specific cell markers known to stain the cytoplasm of certain cell populations. Cells stained intracellularly by microinjection of horseradish peroxidase during physiological recording experiments may be stained in thick (ca. 50 μm) sections cut on a vibratome or similar instrument and stained in the standard way, using methods designed for light microscopy. The sections are then postfixed in osmium tetroxide and embedded in epoxy plastic. Sections cut from these blocks at thicknesses of from 1 to 5 μm using a dry glass knife may be examined directly in the HVEM with no further staining. This produces a very clear image of the cell on a relatively unstained background. This method provides more than adequate resolution of the boundary of the neuron, allowing measurement of neuronal processes to better than 10-nm precision. Similar results are obtained when the same method is applied to axonal tracing using PHA-L. In this case, the exogenously applied marker is used to label a small population of nearby neurons and to trace their connections with other cells at a distance. The lectin is detected by immunocytochemistry, but the selective contrast of the image is adjustable because the concentration of antigen in the cell is largely controlled by the experimenter. The lectin is distributed diffusely in the cytoplasm in a pattern identical to that of intracellular staining, so like intracellular staining, it reveals the overall shape of the cell. Immunocytochemical labelling using endogenous antigens known to be distributed in the cytoplasm of specific neurons produced inadequate control of selective contrast when prepared in this manner. Instead, 1–10μm sections cut from blocks of nervous tissue were embedded in polyethylene glycol, stained using a combedded in polyethylene glycol, stained using a combination of immunocytochemistry and histochemical intensification methods, and embedded in plastic on the grid. This method, which is also suited for staining with poorly penetrating markers such as colloidal gold, may also prove useful in a variety of other situations requiring the intensification of selective contrast.  相似文献   

5.
S. Soni 《Scanning》1983,5(1):45-46
A scanning electron microscope fitted with a sensitive cathodoluminescence detector system has been used for the identification of pollen grains stained with acridine orange or unstained. This approach provides a means of identifying and studying the morphological details of pollens. Cathodoluminescence detection can, in principle, extend the limits of resolution beyond those obtainable with the fluorescence microscope.  相似文献   

6.
The study of in vitro perfused individual nephron segments requires a microscope which provides: (1) easy access to the specimen for measurement of cellular solute flux and voltage; (2) an image with high resolution and contrast; (3) optical sectioning of the object at different levels; and (4) rapid recording of the morphological phenomena. This paper describes an example of commercially available apparatus meeting the above requirements, and illustrates its efficiency. The microscope is of the inverted type (Zeiss IM 35) equipped with differential-interference-contrast (DIC) with a long working distance, and an automatically controlled camera system. The microscopic image exhibits cellular and intercellular details in the unstained transporting mammalian nephron segments despite their tubular structure and great thickness and makes obvious function-structure correlations (e.g. cell volume changes); luminal and contraluminal cell borders are well resolved for controlled microelectrode impalement.  相似文献   

7.
Three-dimensional (3-D) cell morphology is important for the understanding of cell function and can by quantified in terms of volume and surface area. Differential interference contrast (DIC, or Nomarski) imaging can enable cell edges to be clearly visualized in unstained tissue due to the slight difference in refractive index between aqueous media and cytoplasm. DIC is affected in only one direction - the direction of the optical shear. A 1-D edge detector was used in that direction with a scale length equal to that of an in-focus edge to highlight cell boundaries. By comparison with the signal from the edge detector on an out-of-focus slice, the in-focus slices could be segmented and, after noise suppression, cell outlines obtained. A voxel paradigm was used to calculate cell volume and differential geometry was used for surface area estimation. We applied this approach to obtain 3-D dimensional information by optical sectioning of motile Amoeba proteus.  相似文献   

8.
The properties of two electron microscope phase contrast imaging methods are compared. The first is the conventional bright-field method in which dark phase contrast is created by defocusing; the second is a phase plate method in which bright phase contrast is created by means of a suitably shaped electric field. Using some negatively stained biological specimens which have a well-known repeating structure as the test object, it is shown that the phase plate method has some important advantages over the bright-field method. Its contrast transfer characteristics are such that it can provide a more faithful representation of the high resolution detail in the object. Moreover, by producing bright, rather than the normal dark, phase contrast it is able to simultaneously enhance the detail in the specimen and weaken the detail in the stain; this latter property enables the method to display information about the specimen that it would not be possible to detect with the bright-field method.  相似文献   

9.
A prism-mirror-prism electron energy filter has been inserted into a fixed beam transmission electron microscope. The insertion of the filter has not degraded the spatial resolution of the microscope, while providing an energy resolution of 2.5 eV. The filter greatly reduces the chromatic aberration of the images, increasing resolution in dark field and contrast in bright field. Images of bacteriophage T4 and of polyoma virus indicate that thick unstained and unshadowed biological specimens can now be observed at high resolution in dark field. In addition, the increased contrast and definition observed in bright-field images of conventional liver sections suggest that it should be possible to obtain sufficient contrast from stains containing atoms of lower atomic numbers than those employed at present.  相似文献   

10.
Cells were cultivated on transparent conductive substrates, glass slides coated with indium oxide; individual cells were marked with a diamond indentor. Cell cultures were frozen (–15°C), thawed, and then stained with fluorescent dyes to determine cell damage. The marked cells were examined by phase contrast, fluorescence, and Nomarski DIC microscopy. After aldehyde and osmium tetroxide fixation, the cell preparations were sequentially treated with tannic acid, uranyl acetate, and lead citrate. The same marked cell could be sequentially studied by light microscopy (LM; in water immersion conditions), scanning electron microscopy (SEM; after dehydration and critical point drying), and transmission electron microscopy (TEM; after embedding of cell samples in epoxy resin and laser marking of the cell previously marked with a diamond indentor). The method used ensures good preservation of cell morphology, cell surface relief, and intracellular structures. The treatment used renders the cells conductive and permitted SEM of uncoated culture cells on conductive substrates.  相似文献   

11.
In this study backscattered electron (BSE) imaging was used to display cellular structures stained with heavy metals within an unstained resin by atomic number contrast in successively deeper layers. Balb/c 3T3 fibroblasts were cultured on either 13-mm discs of plastic Thermanox, commercially pure titanium or steel. The cells were fixed, stained and embedded in resin and the disc removed. The resin block containing the cells was sputter coated and examined in a field-emission scanning electron microscope. The technique allowed for the direct visualization of the cell undersurface and immediately overlying areas of cytoplasm through the surrounding embedding resin, with good resolution and contrast to a significant depth of about 2 μm, without the requirement for cutting sections. The fixation protocol was optimized in order to increase heavy metal staining for maximal backscattered electron production. The operation of the microscope was optimized to maximize the number of backscattered electrons produced and to minimize the spot size. BSE images were collected over a wide range of accelerating voltages (keV), from low values to high values to give ‘sections' of information from increasing depths within the sample. At 3–4 keV only structures a very short distance into the material were observed, essentially the areas of cell attachment to the removed substrate. At higher accelerating voltages information on cell morphology, including in particular stress fibres and cell nuclei, where heavy metals were intensely bound became more evident. The technique allowed stepwise ‘sectional’ information to be acquired. The technique should be useful for studies on cell morphology, cycle and adhesion with greater resolution than can be obtained with any light-microscope-based system.  相似文献   

12.
The design of a scanned-cantilever-type force microscope is presented which is fully integrated into an inverted high-resolution video-enhanced light microscope. This set-up allows us to acquire thin optical sections in differential interference contrast (DIC) or polarization while the force microscope is in place. Such a hybrid microscope provides a unique platform to study how cell surface properties determine, or are affected by, the three-dimensional dynamic organization inside the living cell. The hybrid microscope presented in this paper has proven reliable and versatile for biological applications. It is the only instrument that can image a specimen by force microscopy and high-power DIC without having either to translate the specimen or to remove the force microscope. Adaptation of the design features could greatly enhance the suitability of other force microscopes for biological work.  相似文献   

13.
A technique is described which enables microradiographic examination to be carried out in a scanning electron microscope (SEM) or X-ray microanalyser. Comparison can readily be made between the radiographic image, a conventional scanning electron image or X-ray image. A wide range of materials have been examined in a Cambridge Scientific Instruments Microanalyser Mark 1 and a Stereoscan S1 scanning electron microscope and a resolution of 1 μm has been consistently achieved.  相似文献   

14.
Improving DIC microscopy with polarization modulation   总被引:2,自引:0,他引:2  
It is demonstrated experimentally, as well as analytically, that when the polarization of the light incident upon the first Nomarski–Wollaston prism in a differential interference contrast (DIC) light microscope is switched by 90°, image highlights are changed into shadows and vice versa. Using an inexpensive ferroelectric liquid-crystal modulator, which is easily installed in the microscope, this switching can be done at 30 frames s−1, synchronized to the camera. Subtraction of alternate digitized frames generates a stream of images in which contrast is doubled, compared with conventional video-enhanced DIC, while image defects and noise tend to cancel. Subtraction of alternate images is carried out efficiently by frame buffer operations and amounts to massively parallel synchronous detection. The new method eliminates the problems inherent in obtaining a separate background image, as required by current video-enhanced DIC practice, without loss of resolution.  相似文献   

15.
We report a rapid hyperspectral fluorescence lifetime imaging (FLIM) instrument that exploits high-speed FLIM technology in a line-scanning microscope. We demonstrate the acquisition of whole-field optically sectioned hyperspectral fluorescence lifetime image stacks (with 32 spectral bins) in less than 40 s and illustrate its application to unstained biological tissue.  相似文献   

16.
张祥翔 《光学仪器》2015,37(6):550-560
概述了光学宽视场显微镜、共聚焦显微镜、超分辨率显微镜中所应用的现代显微成像技术,对各种传统和先进的显微成像原理进行了总结。光学宽视场显微镜最常用的显微技术有明场成像、暗场成像、相衬成像、偏光成像、微分干涉(DIC)成像、调制对比成像和荧光成像。相衬成像中根据不同的成像结构还有切趾相衬成像。微分干涉除了传统的偏振光照明还有圆偏振光照明(C-DIC)和专用于塑料的微分干涉(PlasDIC)。共聚焦显微镜随着计算机技术和制造技术的发展而有了巨大的发展。除了传统的共聚焦荧光显微镜以外,还有连续反斯托克斯拉曼散射(CARS)共聚焦、多光子共聚焦和白光共聚焦。超分辨率显微镜中主要介绍了受激辐射淬灭(STED)技术和紧随基态淬灭显微技术的单分子返回(GSDIM)技术。  相似文献   

17.
By combining electron tomography with energy-filtered electron microscopy, we have shown the feasibility of determining the three-dimensional distributions of phosphorus in biological specimens. Thin sections of the nematode, Caenorhabditis elegans were prepared by high-pressure freezing, freeze-substitution and plastic embedding. Images were recorded at energy losses above and below the phosphorus L2,3 edge using a post-column imaging filter operating at a beam energy of 120 keV. The unstained specimens exhibited minimal contrast in bright-field images. After it was determined that the specimen was sufficiently thin to allow two-window ratio imaging of phosphorus, pairs of pre-edge and post-edge images were acquired in series over a tilt range of +/-55 degrees at 5 degrees increments for two orthogonal tilt axes. The projected phosphorus distributions were aligned using the pre-edge images that contained inelastic contrast from colloidal gold particles deposited on the specimen surface. A reconstruction and surface rendering of the phosphorus distribution clearly revealed features 15-20 nm in diameter, which were identified as ribosomes distributed along the stacked membranes of endoplasmic reticulum and in the cytoplasm. The sensitivity of the technique was estimated at < 35 phosphorus atoms per voxel based on the known total ribosomal phosphorus content of approximately 7000 atoms. Although a high electron dose of approximately 10(7)e/nm2 was required to record two-axis tilt series, specimens were sufficiently stable to allow image alignment and tomographic reconstruction.  相似文献   

18.
Images of unstained, unshadowed DNA prepared by the Kleinschmidt method have been obtained in bright field TEM with a usable contrast. Operating conditions include a strong defocus and a highly coherent illuminating beam. Observations suggest that a specific interaction exists between the nucleic acid and the carrier protein: cytochrome C. Computer simulations of beam-specimen interaction and of image formation were performed. The calculated dependence of contrast on defocus agrees qualitatively with the experimental results. We conclude that experiments with unstained biological specimens are feasible and are necessary (in spite of difficulties) to corroborate results obtained with stained material.  相似文献   

19.
A simple, inexpensive technique for enhancing the contrast and resolution of videomicroscope images has been developed. The system has manual controls for gain and pedestal (black level) which permit expansion of low contrast images to the full white-to-black video range. Analog delay-line based circuits are used to sharpen the edges and enhance fine details in the image. These circuits also produce an effective increase in the information content of the image by selectively amplifying low amplitude, high frequency components of the video signal. When live, unstained cells were examined at high magnifications, cytoplasmic structures which were only faintly visible in the unenhanced image became clear. The images of fluorescent objects appear in pseudo-relief, which improves visibility even in the presence of background fluorescence. The system enhances images by performing signal processing functions that otherwise require expensive digital image processing equipment.  相似文献   

20.
A technique for obtaining differential interference contrast (DIC) imaging using a confocal microscope system is examined and its features compared to those of existing confocal differential phase contrast (DPC) techniques as well as to conventional Nomarski DIC. A theoretical treatment of DIC imaging is presented, which takes into account the vignetting effect caused by the finite size of the lens pupils. This facilitates the making of quantitative measurements in DIC and allows the user to identify and select the most appropriate system parameters, such as the bias retardation and lateral shear of the Wollaston prism.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号