首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The present work is concerned with exploring the potential of refractive index-based imaging techniques for investigating the heat transfer characteristics of impinging turbulent synthetic jets. The line-of-sight images of the convective field have been recorded using a Mach Zehnder interferometer. Heat transfer experiments have been conducted in infinite fringe setting mode of the interferometer with air as the working fluid. The effect of the excitation frequency of the synthetic jet on the resultant temperature distribution and local heat transfer characteristics has been studied. The fringe patterns recorded in the form of interferograms have first been qualitatively discussed and thereafter, quantitatively analyzed to determine the two-dimensional temperature field. Local heat transfer coefficients along the width of the heated copper block have been determined from the temperature field distribution thus obtained from the interferograms. The results have been presented in the form of interferometric images recorded as a function of frequency of the synthetic jet, corresponding two-dimensional temperature distributions and local variation of heat transfer coefficients. Interferometric measurements predicted maxima of the heat transfer coefficient at the resonance frequency of the synthetic jet and at a jet-to-plate surface spacing (z/d) of 3. These observations correlate well with the thermocouple-based measurements of temperature and heat transfer coefficient performed simultaneously during the experiments. The interferometry-based study, as reported in the present work for the first time in the context of synthetic jets, highlights the importance of refractive index-based imaging techniques as a potential tool for understanding the local heat transfer characteristics of synthetic jets.  相似文献   

2.
In this article, jet’s inlet temperature field is excited and the effect on heat transfer at the target wall after impingement is investigated. Jet’s inlet temperature is excited according to a clipped pseudo-sinusoidal function, which approaches a step-function shape. In all cases, jet’s Reynolds number based on bulk inlet velocity is 23,000 and a jet’s outlet-to-wall distance is 2. Jet is excited at two different amplitudes which are set as 36.2 and 4.76% of the bulk inlet temperature. Also the thermal field of jet is modulated with three different frequencies corresponding to the preferred mode of jet. All Simulations are done in ANSYS CFX using scale-adaptive-simulation model. It is found that amplitude of temperature field excitation is a major factor for improving the heat transfer. The fluid is air in all investigations.  相似文献   

3.
圆形冲击射流传热性能的实验研究   总被引:5,自引:1,他引:5  
应用萘升华传质/传热比拟技术,对单个圆形射流在不同喷嘴到被冲击表面距离(1≤H/D≤12),在7×103≤R e≤1.9×104时,进行了局部传质/传热实验;研究了不同喷嘴到被冲击表面距离和不同R e对单个圆形射流局部换热特性的影响。单个圆形射流局部传热系数随着R e的增加而大幅度增加,R e是影响局部换热系数的主要因素。在同一R e下局部换热系数沿轴向非单调变化,在驻点处当H/D≌6时换热系数达到峰值;H/D<6时,局部换热系数沿径向有两个峰值;随H/D的增加,中心区局部N u减小,但影响范围变大。  相似文献   

4.
The present study deals with the turbine casing radiation effect on the impinging cooling encountered in the blade tip active clearance control (ACC) system of aero-engine turbine. To this end, numerical simulations are carried out for a simplified model, that is, a pipe with a single row of impinging jets. The effects of the nozzle-to-plate distance to the diameter of the impinging hole (H/d?=?2–8), the number of the holes (n?=?17–68), the impinging wall temperature (Tp?=?400–800?K), and the inlet Reynolds number (Re?=?5,000–20,000) on the flow and heat transfer are investigated. Analysis is performed on the radiation heat transfer effects on the corresponding flow fields and surface heat flux distributions. The results indicate that, with the radiation included in the simulations, the mass flow rate of the cooling jet near the end of the pipe decreases significantly under the conditions of high wall temperature and small nozzle-to-plate distance. Radiation heat transfer should be accounted for in the numerical study for the casing cooling as it affects the flow and heat transfer remarkably. When the nozzle-to-plate distance is relatively large, such as H/d is larger than 8, the radiative heating leads to uniform heat flux and the radiative heating can suppress the uneven distributions of the heat flux.  相似文献   

5.
Numerical study of the effect of confinement on a flow structure and heat transfer in an impinging mist jets with low mass fraction of droplets (ML1 ? 1%) were presented. The turbulent mist jet is issued from a pipe and strikes into the center of the flat heated plate. Mathematical model is based on the steady-state RANS equations for the two-phase flow in Euler/Euler approach. Predictions were performed for the distances between the nozzle and the target plate x/(2R) = 0.5–10 and the initial droplets size (d1 = 5–100 μm) at the varied Reynolds number based on the nozzle diameter, Re = (1.3–8) × 104. Addition of droplets causes significant increase of heat transfer intensity in the vicinity of the jet stagnation point compared with the one-phase air impinging jet. The presence of the confinement upper surface decreases the wall friction and heat transfer rate, but the change of friction and heat transfer coefficients in the stagnation point is insignificant. The effect of confinement on the heat transfer is observed only in very small nozzle-to-plate distances (H/(2R) < 0.5) both in single-phase and mist impinging jets.  相似文献   

6.
An experimental and numerical study is conducted to investigate turbulent slot jet impingement cooling characteristics on concave plates with varying surface curvature. Air is used as the impingement coolant. In the experimental work, a slot nozzle specially designed with a sixth degree polynomial in order to provide a uniform exit velocity profile was used. The experiments were carried out for the jet Reynolds numbers in the range of 3423  Re  9485, the dimensionless nozzle-to-surface distance range of 1  H/W  14 for dimensionless values of the curvature of impinging surfaces in the range of R/L = 0.5, 0.725, and 1.3 and a flat impingement surface. Constant heat flux was applied on the plates. Numerical computations were performed using the k-ε turbulence model with enhanced wall functions. For the ranges of the governing parameters studied, the stagnation, and local and average Nusselt numbers have been obtained both experimentally and numerically. The numerical results showed a reasonable agreement with the experimental data.  相似文献   

7.
Previous studies on boiling heat transfer by impinging jets were mainly concerned with the impinging point by using small heat transfer surfaces of about 20 mm. An experimental study was made of the boiling heat transfer to an impinging water jet on a massive hot block. The upward heating surface was made of copper, its diameter and the nozzle diameter being 80 and 2.2 mm, respectively. The velocity of the impinging jet was varied between 0.6 and 2.1 m/s. Saturated water impinged normally on the heating surface, flowed radially, and subsequently dispersed into the atmosphere. It is clarified in the present study that heat transfer characteristics vary with the temperature of the heat transfer surface, and also with the distance from the impinging point. © 1999 Scripta Technica, Heat Trans Asian Res, 28(5): 418–427, 1999  相似文献   

8.
This study experimentally investigates the local heat transfer characteristics of a microscale confined impinging air jet on a heated plate. The experimental parameters included the Reynolds number (ReD = 1600–5600), the nozzle-to-plate spacing (H/D = 1–10), and the degree of confinement of the nozzle (DC/D = 3, 6, 9, 12, 24, 48). The degree of confinement of the nozzle is a novel parameter. A reduction in the heat transfer rate was found for nozzles whose DC/D values were 6, 9, 12, 24, and 48 as a result of the confinement effect at small nozzle-to-plate spacings. The confinement effect disappeared beyond H/D values of 2, 3, 4, 8, and 17 for DC/D values of 6, 9, 12, 24, and 48, respectively. Flow characteristics were investigated by measuring pressure distributions along the wall. Subatmospheric pressure, which is evidence of the confinement effect, was observed for the confined nozzles. Correlations of the stagnation and average Nusselt numbers are proposed on the basis of the experimental results. Finally, a contour map that depicts the ratio of the Nusselt numbers of the unconfined and confined jets is presented. The contour map confirms that the confined jets have a smaller Nusselt number than the unconfined jets whenever the degree of confinement of the nozzle is large and the nozzle-to-plate spacing is small.  相似文献   

9.
This study numerically investigates the impinging cooling of porous metallic foam heat sink. The analyzed parameters ranges comprise ε = 0.93/10 PPI Aluminum foam, L/W = 20, Pr = 0.7, H/W = 2–8, and Re = 100–40,000. The simulation results exhibit that when the Re is low (such as Re = 100), the Numax occurs at the stagnation point (i.e. X = 0). However, when the Reynolds number increases, the Numax would move downwards, i.e. the narrowest part between the recirculation zone and the heating surface. Besides, the extent to which the inlet thermal boundary condition influences the prediction accuracy of the Nusselt number increases with a decreasing H/W and forced convective effect. The application ranges of H/W and Re that the effect of the inlet thermal boundary condition can be neglected are proposed. Lastly, comparing our results with those in other studies reveals that the heat transfer performance of the Aluminum foam heat sink is 2–3 times as large as that without it. The thermal resistance is also 30% less than that of the plate fin heat sink for the same volumetric flow rate and the 5.3 mm jet nozzle width. Therefore, the porous Aluminum foam heat sink enhances the heat transfer performance of impinging cooling.  相似文献   

10.
This paper presents the results of a comprehensive numerical study to analyze turbulent mixed convection in a vertical channel with a flush-mounted discrete heat source in each channel wall. The conjugate heat transfer problem is solved to study the effect of various parameters like the thermal conductivity of the wall material (ks), the thermal conductivity of the flush-mounted discrete heat source (kc), Reynolds number (Res), modified Richardson number (Ri⁎) and the aspect ratio of the channel (AR). The standard kε turbulence model, modified by including buoyancy effects, without wall functions, has been used for the analysis. The two-dimensional governing equations are discretised on a semi-staggered, non-uniform grid, using the finite volume method. The asymptotic computational fluid dynamics (ACFD) technique has been then applied to obtain a correlation for the non-dimensional maximum temperature θ¯max, which can be used for a wide range of parameters.  相似文献   

11.
The objective of this work is to carry out a numerical investigation to examine the effects of geometric parameters on the confined impinging jet heat transfer. Parameters such as Nusselt number, Reynolds number, H/W have been studied. Nozzle width H ranges from 0.6 mm to 2 mm, and nozzle-to-plate spacing W ranges from 0.5 mm to 10 mm. The jet flow is in the range of laminar flow with Reynolds number from 26.8 to 1000. This paper presents distributions of target surface temperature, local and average Nusselt number on the target plate. Pressure drop for different H/W is also obtained. This study can provide useful information to the application of impinging jet heat transfer in industry.  相似文献   

12.
13.
Flow visualisations and heat transfer measurements on a rotating disk, with a relatively small centred jet perpendicularly impinging on it, are accomplished by means of infrared (IR) thermography associated with the heated-thin-foil thermal sensor. Flow visualisations show a strong interaction between the turbulent jet and the laminar boundary layer over the rotating disk. A new governing similitude parameter is introduced and a heat transfer correlation for the Nusselt number at the disk centre is proposed. In most cases, the Nusselt number radial profiles tend to overlap if they are normalised with the Nusselt number computed by means of this correlation.  相似文献   

14.
A numerical study was carried out of heat transfer under a pulsating turbulent slot impinging jet. The jet velocity was varied in an intermittent (on–off) fashion. The effects of the time-mean jet Reynolds number, temperature difference between the jet flow and the impinging surface, nozzle-to-target distance as well as the frequency on heat and mass transfer were examined. The numerical results indicate significant heat transfer enhancement due to intermittent pulsation of the jet flow over a wide range of conditions for both cooling and heating cases. Simulations of the flow and temperature fields show that the instantaneous heat transfer rate on the target surface is highly dependent on the hydrodynamic and thermal boundary layer development with time.  相似文献   

15.
16.
An experimental investigation is carried out on the entrance region heat transfer in a parallel plate channel downstream of a jet array located in one of the plates. The jet impingement surface is kept isothermal while the opposing surface, containing the jet array, is adiabatic. The focus of the investigation is the systematic study of the effect of flow rate and array geometric parameters on local Nusselt numbers in the entrance region of the channel immediately downstream of the array. To place these results in context, Nusselt numbers opposite the array and in the fully developed region downstream of the channel entrance are also included. In the entrance region, the ratio of the local to fully developed Nusselt number is independent of the channel Reynolds number, and the effects of some jet array geometric parameters are significant. These effects become negligible within 10 hydraulic diameters from the channel entrance. The entrance length is about 21 hydraulic diameters. The fully developed Nusselt numbers agree well with previous measurements. Empirical correlations are developed to fit the observations.  相似文献   

17.
Analysis of the heat transfer of an impinging laminar flame jet   总被引:1,自引:0,他引:1  
Flame jet impingement is used in many industrial processes. In this paper an analytical expression is derived for the heat flux of a laminar flame impinging on a flat plate, where the flame jet is approximated by a hot inert jet with the position of the tip of the flame taken equal to the nozzle position. The heal flux in this expression is dependent on the nozzle-to-plate spacing, in contradiction to existing (semi-analytical) relations. The geometry is divided in a region far from the plate and a region dose to the plate. For both regions the velocity profiles are calculated using only the dominant terms of the balance equations. Subsequently these profiles are linked to each other at the boundary between the two zones. Implementing the resulting velocity profile for the complete geometry in the energy equation and integrating over the whole domain results in an expression for the heat flux from the flame to the plate at the hot spot. Numerical calculations show very good agreement with the results of the analytical derivation.  相似文献   

18.
A model using an analytical/empirical approach has been developed to predict the rate of heat transfer in the stagnation region of a planar jet impinging on a horizontal flat surface. The model has been developed based on the hypothesis that bubble-induced mixing would result in enhanced or additional diffusivity. The additional diffusivity has been included in the diffusion term of the conservation equations. The value of the effective diffusivity has been correlated with jet parameters (velocity and temperature) and surface temperature using experimental data. The important aspects of the bubble dynamics (generation frequency and average bubble diameter) have been acquired using high-speed imaging and an intrusive optical probe. The applicability of the proposed model has been investigated under conditions of partial and fully-developed nucleate boiling. Experiments have been carried out using water at atmospheric pressure, mass flux in the range of 388–1649 kg/m2 s, degree of sub-cooling in the range of 10–28 °C, and surface temperature in the range of 75–120 °C. Results showed that the proposed model is able to predict the surface heat flux with reasonable accuracy (+30% and ?15%).  相似文献   

19.
Flow and heat transfer characteristics of swirling impinging jet (SIJ) were studied experimentally at constant nozzle-to-plate distance of L = 4D. The swirling jet is generated by inserting twisted tapes within a pipe nozzle. Effects of swirl on the impinged surface are investigated at twist ratios (y/W) of ∞ (straight tape), 3.64, 2.27, 1.82, and 1.52. The flow patterns of the free swirling jet and the swirling impinging jet were visualized by mixing dye with the jet flow. Distributions of temperature and convective heat transfer coefficient on the impinged surface were measured with thermochromic liquid crystal (TLC) sheet and image processing technique. Additionally, an oil film technique was performed as a complementary technique for flow visualization on the impinged surface. The experimental results reveal that there appear to be two peaks of heat transfer in the jet impingement region. The heat transfer enhancements in jet impingement region can be achieved at a low twist ratio of 3.64 which corresponds to the swirl number of 0.4.  相似文献   

20.
Recent technological developments have lead to significant increase in the generated heat by electronic and optical components. The removal of high heat fluxes can be successfully treated by several methods, e.g. impinging jets. Further improvement is offered by incorporating arrays of jets or causing jets to pulsate. The research reported herein introduces a new method which is based on actuation of a slab against a two dimensional steady, impinging, laminar, liquid micro-jet. This leads to enhanced heat transfer in the wall region of the jet. An experimental setup which included a piezoelectric (PZT) actuator, a dedicated silicon chip and a steady, slot, impinging jet, was assembled. Using a high speed infrared (IR) radiometer, the cooling process of the chip was recorded and the heat transfer enhancement values were determined for normalized actuation amplitudes, Reynolds and Strouhal numbers in the ranges of 0.45 < δ < 0.75, 756 < Re < 1260 and 0 < St < 0.052, respectively. It was experimentally found that heat transfer coefficients were enhanced by up to 34%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号