首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The results of experimental investigations of heat transfer during the flow of R134a in a minichannel are presented here. The experimental investigations were conducted using a minichannel with a total length of 500 mm and 1.68 mm internal diameter. The heated length of the minichannel was 200 mm, the total mass flow rate of the refrigerant () = 200–450 kg/m2 s, the inlet subcooling ΔTs = 5–15 K, and the heat flux density q = 1.7–60.3 kW/m2. The results of experimental investigations are presented as a boiling curve. The phenomenon known as the zero boiling crisis and the influence of the flashing phenomenon on the boiling curve show the importance of these elements on heat transfer in single- and two-phase systems.  相似文献   

2.
Flow boiling of R-123 in a hydrofoil-based micro pin fin heat sink was investigated. Average two-phase heat transfer coefficients were obtained over effective heat fluxes ranging from 19 to 312 W/cm2 and mass fluxes from 976 to 2349 kg/m2 s. The paper presents a flow map, which divides the data into three flow pattern regions: bubbly, wavy intermittent and spray-annular flows. Heat transfer coefficient trends and flow morphologies were used to infer boiling heat transfer mechanisms. Existing conventional scale correlations for circular tubes resulted in large scatter and were not able to predict the heat transfer coefficients accurately.  相似文献   

3.
Three-dimensional simulations of condensation of refrigerant R134a in a horizontal minichannel are presented. Mass fluxes ranging from 50 kg m?2 s?1 up to 1000 kg m?2 s?1 are considered in a circular minichannel of 1 mm diameter, and uniform wall and vapour–liquid interface temperatures are imposed as boundary conditions. The Volume of Fluid (VOF) method is used to track the vapour–liquid interface; the effects of interfacial shear stress, gravity and surface tension are taken into account. The influence of turbulence in the condensate film is analysed and compared against the assumption of laminar condensate flow by employing different computational approaches and validating the results against experimental data. Under the assumption of laminar condensate flow, experimental heat transfer coefficient values at low mass fluxes can be predicted, but the computed heat transfer coefficient is found to be almost independent of mass flux and vapour quality. Only when turbulence in the condensate film is taken into account does the numerical model capture the influence of mass flux that is observed in the experimental measurements.  相似文献   

4.
The objective of this work is to present new condensation heat transfer coefficients measured inside a single square cross section minichannel, having a 1.18 mm side length, and compare them to the ones previously measured in a circular minichannel. Tests have been performed with R134a at 40 °C saturation temperature, at mass velocity ranging between 200 and 800 kg m?2 s?1. As compared to the heat transfer coefficients measured in the circular cross section channel, for the same hydraulic diameter, in the square minichannel the authors find a heat transfer enhancement at the lowest value of mass velocity, which must be due to the effect of surface tension. No heat transfer coefficient increase has been found at the highest values of the mass velocity where condensation is shear stress dominated.  相似文献   

5.
Heat transfer with liquid–vapor phase change in microchannels can support very high heat fluxes for use in applications such as the thermal management of high-performance electronics. However, the effects of channel cross-sectional dimensions on the two-phase heat transfer coefficient and pressure drop have not been investigated extensively. In the present work, experiments are conducted to investigate the local flow boiling heat transfer of a dielectric fluid, Fluorinert FC-77, in microchannel heat sinks. Experiments are performed for mass fluxes ranging from 250 to 1600 kg/m2 s. Seven different test pieces made from silicon and consisting of parallel microchannels with nominal widths ranging from 100 to 5850 μm, all with a nominal depth of 400 μm, are considered. An array of temperature sensors on the substrate allows for resolution of local temperatures and heat transfer coefficients. The results of this study show that for microchannels of width 400 μm and greater, the heat transfer coefficients corresponding to a fixed wall heat flux as well as the boiling curves are independent of channel size. Also, heat transfer coefficients and boiling curves are independent of mass flux in the nucleate boiling region for a fixed channel size, but are affected by mass flux as convective boiling dominates. A strong dependence of pressure drop on both channel size and mass flux is observed. The experimental results are compared to predictions from a number of existing correlations for both pool boiling and flow boiling heat transfer.  相似文献   

6.
The subcooled flow boiling heat transfer characteristics of a kerosene kind hydrocarbon fuel were investigated in an electrically heated horizontal tube with an inner diameter of 1.0 mm, in the range of heat flux: 20–1500 kW/m2, fluid temperature: 25–400 °C, mass flux: 1260–2160 kg/m2 s, and pressure: 0.25–2.5 MPa. It was proposed that nucleate boiling heat transfer mechanism is dominant, as the heat transfer performance is dependent on heat flux imposed on the channel, rather than the fuel flow rate. It was found that the wall temperatures along the test section kept constant during the fully developed subcooled boiling (FDSB) of the non-azeotropic hydrocarbon fuel. After the onset of nucleate boiling, the temperature differences between inner wall and bulk fluid begin to decrease with the increase of heat flux. Experimental results show that the complicated boiling heat transfer behavior of hydrocarbon fuel is profoundly affected by the pressure and heat flux, especially by fuel subcooling. A correlation of heat transfer coefficients varying with heat fluxes and fuel subcooling was curve fitted. Excellent agreement is obtained between the predicted values and the experimental data.  相似文献   

7.
An experimental test rig for study on the pooling-boiling heat transfer performance of pure and mixed refrigerants were designed and established. With this test system, the heat transfer coefficients (HTCs) of the nucleate boiling on a smooth flat surface were measured for pure fluids of HFC134a, HC290, HC600a and their binary and ternary mixtures. Extensive experimental measures were made for those pure and mixed refrigerants at different heat fluxes from 10 kW m−2 to 300 kW m−2 and different pressures from 0.2 to 0.6 MPa. Comprehensive measured data are presented in this paper. From experimental results, these binary mixtures and ternary mixtures show different heat transfer features according to their vapor–liquid phase equilibria behaviors. New heat transfer correlations were regressed from the measured data with average deviations within ±15% for pure refrigerants and within ±20% for mixtures.  相似文献   

8.
HFO1234yf has been proposed for mobile air-conditioners due to its low global warming potential (GWP) and performance comparable to that of R134a. However, its performance is inferior to that of R410A. This makes it difficult to be applied to residential air-conditioners. In order to apply the low-GWP refrigerant to residential air-conditioners, refrigerant mixtures of HFO1234yf and R32 are proposed, and their flow boiling heat transfer performances were investigated at two mass fractions (80/20 and 50/50 by mass%) in a smooth horizontal tube with an inner diameter of 2 mm. The experiments were conducted under heat fluxes ranging from 6 to 24 kW/m2 and mass fluxes ranging from 100 to 400 kg/m2 s at the evaporation temperature of 15 °C. The measured heat transfer coefficients were compared with those of pure HFO1234yf and R32. The results showed that the heat transfer coefficients of the mixture with an R32 mass fraction of 20% were 10–30% less than those of pure HFO1234yf for various mass and heat fluxes. When the mass fraction of R32 increased to 50%, the heat transfer coefficients of the mixture were 10–20% greater than those of pure HFO1234yf under conditions of large mass and heat fluxes. Moreover, the heat transfer coefficients of the mixtures were about 20–50% less than that of pure R32. The performances of the mixtures were examined at different boiling numbers. For refrigerant mixture HFO1234yf and R32 (80/20 by mass%), the nucleate boiling heat transfer was noticeably suppressed at low vapor quality for small boiling numbers, whereas the forced convective heat transfer was significantly suppressed at high vapor quality for large boiling numbers. This indicates that the heat transfer is greatly influenced by the mass diffusion resistance and temperature glide of the mixture.  相似文献   

9.
Experiments were conducted to investigate flow boiling in 200 μm × 253 μm parallel microchannels with structured reentrant cavities. Flow morphologies, boiling inceptions, heat transfer coefficients, and critical heat fluxes were obtained and studied for mass velocities ranging from G = 83 kg/m2 s to G = 303 kg/m2 s and heat fluxes up to 643 W/cm2. Comparisons of the performance of the enhanced and plain-wall microchannels were performed. The microchannels with reentrant cavities were shown to promote nucleation of bubbles and to support significantly better reproducibility and uniformity of bubble generation. The structured surface was also shown to significantly reduce the boiling inception and to enhance the critical heat flux.  相似文献   

10.
Experiments on flow boiling heat transfer in high aspect ratio micro-channels with FC-72 were carried out. Three channels with different hydraulic diameters (571, 762 and 1454 μm) and aspect ratios (20, 20 and 10) were selected. The tested mass fluxes were 11.2, 22.4 and 44.8 kg m?2 s?1 and heat fluxes ranging from 0–18.6 kW m?2. In the present study, boiling curves with obvious temperature overshoots are presented. Average heat transfer coefficient and local heat transfer coefficient along stream-wise direction are measured as a function of heat flux and vapour quality respectively. Slug-annular flow and annular flow are the main flow regimes. Convective boiling is found to be the dominant heat transfer mechanism. Local heat transfer coefficient increases with decreasing hydraulic diameter. Moreover, the effect of hydraulic diameter is more significant when mass flux is higher. The unique channel geometry is considered as the decisive reason of the flow regimes as well as heat transfer mechanisms.  相似文献   

11.
To identify effects of the bottom inflow area on pool boiling heat transfer in a vertical annulus, three tube diameters (16.5, 25.4, 34.0 mm) and the saturated water at atmospheric pressure has been tested. The inflow area has been changed from 0 to 1060.3 mm2. To clarify effects of the inflow area on heat transfer results of the annulus are compared to the data of a single unrestricted tube. The inflow area changes heat transfer coefficients much and moves the deterioration point of heat transfer coefficients to the higher heat fluxes. To quantify effects of the inflow area on heat transfer, a new empirical correlation has been developed in terms of the area ratio, inflow area, and the heat flux. The correlation predicts the heat transfer data of boiling within ±10%.  相似文献   

12.
This paper investigates flow boiling of water in microchannels with a hydraulic diameter of 227 μm possessing 7.5 μm wide reentrant cavities on the sidewalls. Average two-phase heat transfer coefficients and CHF conditions have been obtained over a range of effective heat fluxes (28–445 W/cm2) and mass velocities (41–302 kg/m2 s). High Boiling number and Reynolds number have been found to promote convective boiling, while Nucleate Boiling dominated at low Reynolds number and Boiling number. A criterion for the transition between nucleate and convective boiling has been provided. Existing correlations did not provide satisfactory agreement with the heat transfer coefficient but did predict CHF conditions well.  相似文献   

13.
This paper presents the experimental heat transfer evaluation during subcooled and saturated boiling of ammonia–lithium nitrate solution in a fusion plate heat exchanger, acting as a vapor generator under operating conditions representative of single-effect absorption machines. The solution flow rate and outlet temperature were modified in the ranges of 0.041–0.083 kg/s and 78–97 °C, respectively. The region where vapor bubbles begin to arise is estimated using a correlation for the wall superheat required for the onset of nucleate boiling. Results show that subcooled boiling is present in the generator. The initial boiling temperature is about 3.1 °C lower than the saturation temperature. The influence of the heat and mass fluxes on the boiling heat transfer coefficient is analyzed. The paper offers a correlation for the Nusselt number, including the subcooled and saturated boiling regions.  相似文献   

14.
This study concerns water saturated flow boiling heat transfer in an array of staggered square micro-pin-fins having a 200 × 200 μm2 cross-section by a 670 μm height. Three inlet temperatures of 90, 60, and 30 °C, six mass velocities for each inlet temperature, ranging from 183 to 420 kg/m2 s, and outlet pressures between 1.03 and 1.08 bar were tested. Heat fluxes ranged from 23.7 to 248.5 W/cm2. Heat transfer coefficient was fairly constant at high quality, insensitive to both quality and mass velocity. Heat transfer was enhanced by inlet subcooling at low quality. Possible heat transfer mechanism was discussed.  相似文献   

15.
This experimental study aims to investigate the heat transfer characteristics of single-phase turbulent flow of R-134a refrigerant in a rectangular multi-micro channel heat sink having 27 channels where each channel has a hydraulic diameter of 421 μm. Experimental results were obtained for inlet temperatures ranging from 24 to 33 °C, mass fluxes from 1485 to 2784 kg m 2 s 1 and wall heat fluxes from 3 to 24 kW m 2. The results indicate that the heat transfer coefficients are found to be higher at lower inlet temperatures than those at higher ones. In addition, when equal amount of heat supplied to the heat sink, the heat transfer coefficients increase with increasing the mass flux of refrigerant. They were also compared with 12 well-known correlations and it was seen that 4 of 12 were in good agreement with each other with the average deviation < 10%. The findings demonstrate that well-known correlations in fundamental sources can be used to predict the heat transfer coefficient of R-134a during its single phase flow in a multiport microchannel heat sink under turbulent regime.  相似文献   

16.
An experimental study is carried out to investigate the characteristics of the evaporation heat transfer for different fluids. Namely, pure refrigerants fluids (R22 and R134a), azeotropic and quasi-azeotropic mixtures (R404A, R410A, R507) and zeotropic mixtures (R407C and R417A).The test section is a smooth, horizontal, stainless steel tube (6 mm ID, 6 m length) uniformly heated by the Joule effect. The flow boiling characteristics of the refrigerant fluids are evaluated in 250 different operating conditions. Thus, a data-base of more than 2000 data points is produced.The experimental tests are carried out varying: (i) the refrigerant mass fluxes within the range 200–1100 kg/m2 s; (ii) the heat fluxes within the range 3.50–47.0 kW/m2; (iii) the evaporating pressures within the range 3.00–12.0 bar.In this study, the effect on measured heat transfer coefficient of vapour quality, mass flux, saturation temperature, imposed heat flux, thermo-physical properties are examined in detail.  相似文献   

17.
An experimental investigation has been carried out to study effects of surfactant additive on microscale boiling under pulse heating over a Pt microheater (140 × 100 μm2) fabricated in a trapezoidal microchannel (600 μm in width and 150 μm in depth). Experiments are carried out for six different surfactant concentrations of Triton X-100 ranging from 47 ppm to 2103 ppm, for mass flux in the range from 45 kg/m2 s to 225 kg/m2 s, pulse width in the range from 50 μs to 2 ms, and heat flux in the range from 3 MW/m2 to 65 MW/m2. As in existing work on pool boiling under steady heating, it is found that nucleate boiling becomes more vigorous and heat transfer is enhanced greatly with the addition of surfactant with maximum boiling heat transfer occurs at the critical micelle concentration (cmc). Furthermore, these maximum values of boiling heat transfer coefficient increase with decreasing pulse width. When concentration is below cmc, the heat flux needed for nucleation increases with increasing concentration and the nucleation temperature is reduced. When concentration is higher than cmc, the boiling heat transfer coefficient decreases and nucleation temperature is higher than that of pure water.  相似文献   

18.
An experimental study has been performed on single-phase heat transfer, boiling inception, and pressure drop of R-123 over a bank of shrouded micro pin fins 243 μm long with hydraulic diameter of 99.5 μm. Heat transfer coefficients and Nusselt numbers have been obtained over effective heat fluxes ranging from 3.5 to 65.5 W/cm2 and Reynolds numbers from 134 to 314. A delay in boiling incipience has been observed and a meta-stable single-phase region was apparent at liquid exit temperatures noticeably exceeding the saturation temperature. Once boiling was initiated, vapor burst instabilities resembling the compound relaxation instabilities were attained. It has also been found that endwalls effects on heat transfer diminished for Re > 100.  相似文献   

19.
Due to the important role of microscale heat transfer, an analysis of the heat transfer coefficient for a 1 mm inner diameter tube, with FC-72 as working fluid, has been performed. The study is aimed to identify the best correlation or model to predict the available experimental database. A comparison of several models and correlations, available in the literature for micro- and macroscale, has been performed, focusing the present preliminary analysis to the saturated boiling conditions. Experimental data have been provided by ENEA through the facility BO.E.MI.A. (BOiling Experiments in MIcrochannel Apparatus), in the pressure range from 3 to 5 bar, with a mass flux from 800 to 1200 kg/m2s and thermal fluxes from 1.6 to 181 KW/m2. The best results, in this preliminary analysis of the saturated boiling points, were obtained for microscale correlations of Li and Wu, with more than 91% of data within ± 30% error and a mean absolute percent error (MAPE) of 13.4%. Among the macroscale correlations only the Chen correlation provides good results, but with a lower agreement with the experimental data. Theoretical models are very promising but need further works to find the appropriate parameters valid for the specific fluid. A more detailed analysis including subcooling conditions will be performed in a future work.  相似文献   

20.
An experimental investigation on two-phase flow boiling heat transfer with refrigerants of R-22, R-134a, R-410A, C3H8 and CO2 in horizontal circular small tubes is presented. The experimental data were obtained over a heat flux range of 5–40 kW m?2, mass flux range of 50–600 kg m?2 s?1, saturation temperature range of 0–15 °C, and quality up to 1.0. The test section was made of stainless steel tubes with inner diameters of 0.5, 1.5 and 3.0 mm, and lengths of 330, 1000, 1500, 2000 and 3000 mm. The experimental data were mapped on Wang et al. (1997) [5] and Wojtan et al. (2005) [6] flow pattern maps. The effects of mass flux, heat flux, saturation temperature and inner tube diameter on the heat transfer coefficient are reported. The experimental heat transfer coefficients were compared with some existing correlations. A new boiling heat transfer coefficient correlation that is based on a superposition model for refrigerants in small tubes is presented with 15.28% mean deviation and ?0.48% average deviation.  相似文献   