MBR工艺处理城镇污水处理厂污泥水中试研究   总被引:2,自引:0,他引:2  
将平板膜组件与传统脱氮除磷工艺相结合,构建了膜生物反应器强化生物脱氮除磷中试系统,并用于处理城镇污水处理厂的污泥系统废水。结果表明,出水CODCr、BOD5、NH3—N、TN和TP的平均浓度分别为70.8 mg/L、8.7 mg/L、15.1 mg/L、29.7 mg/L和0.38 mg/L,达到或接近了《城镇污水处理厂污染物排放标准》(GB 18918—2002)的一级标准。  相似文献   

2.
Shortcut nitrification has been successfully applied in a laboratory scale nitrification-denitrification process consisting of an up-flow anaerobic sludge blanket (UASB) and an aerobic membrane bioreactor (MBR) in treating synthetic and municipal wastewater to simultaneously remove organic carbon and nitrogen. For the treatment of synthetic wastewater, the combined system exhibited a high TOC removal of 98% with a steady ammonia removal efficiency of about 98% in the MBR and a total nitrogen (TN) removal efficiency of 90%. In treating municipal wastewater, due to its low COD concentration, removal efficiencies of TOC, ammonia and TN were 70%, 98% and 60%, respectively. The biogas production was around 76.4 L/m3 wastewater when treating synthetic wastewater. However, little biogas was produced when treating municipal wastewater which was the result of low organic carbon loading to the UASB. Energy analysis has demonstrated that this novel shortcut nitrification process could consume less energy than a conventional process and have the potential of bio-energy generation via biogas production thus helping to achieve a more favorable energy balance.  相似文献   

3.
A full-scale plant of an MBR system treating livestock wastewater has shown impressive results. The Cheorwon County Environmental Authorities adopted the MBR process with UF membrane for retrofitting the old plant, which removes organic matter, nitrogen and phosphorus at a high level. According to 6 months operation data, BOD and SS removal were about 99.9% and COD(Mn), TN and TP removal were 92.0%, 98.3% and 82.7%, respectively. It is considered that the temperature at the bioreactor has to be controlled to be below 40 degrees C so as to ensure sufficient nitrification. It appeared that the MBR system is competitive with other conventional technologies for treatment of livestock wastewater such as piggery waste.  相似文献   

4.
Experiments have been carried out to get an understanding of the effect of DO, C/N ratio and pH on the performance of a bench scale membrane bioreactor (MBR) in simultaneous nitrification and denitrification. It was found that under the conditions of MLSS in the range of 8000-9000 mg/L and temperature of water in the MBR of 24 degrees C, influent COD and NH3-N in the range of 523-700 mg/L and 17.24-24 mg/L respectively, the removals of COD, NH3-N and TN were 98%, 99% and 60%; 96.5%, 0,98% and 75%; 96%, 95% and 92%; 90%,70% and 60% respectively at DO of 6, 3, 1 and 0.5 mg/L. It was also found that the changes in C/N ratio and pH in a certain range have a slight effect on COD removal but have significant influence on the removal of NH3-N and TN. The results showed that only under the conditions that each ecological factor was maintained relatively steadily, simultaneous nitrification and de-nitrification proceeded smoothly. It was found that when C/N ratio was 30, the influent pH 7.2, the temperature of water in MBR 24 degrees C and DO 1 mg/L, as optimum conditions, the removals of COD, NH3-N and TN were 96%, 95% and 92% respectively. In addition, mechanism research on simultaneous nitrification and de-nitrification in MBR has been conducted as well.  相似文献   

5.
Synthetic wastewater was treated using a novel system integrating the reversed anoxic/anaerobic/oxic (RAAO) process, a micro-electrolysis (ME) bed and complex biological media. The system showed superior chemical oxygen demand (COD), total nitrogen (TN) and total phosphorus (TP) removal rates. Performance of the system was optimised by considering the influences of three major controlling factors, namely, hydraulic retention time (HRT), organic loading rate (OLR) and mixed liquor recirculation (MLR). TP removal efficiencies were 69, 87, 87 and 83% under the HRTs of 4, 8, 12 and 16 h. In contrast, HRT had negligible effects on the COD and TN removal efficiencies. COD, TN and TP removal efficiencies from synthetic wastewater were 95, 63 and 87%, respectively, at an OLR of 1.9 g/(L·d). The concentrations of COD, TN and TP in the effluent were less than 50, 15 and 1 mg/L, respectively, at the controlled MLR range of 75-100%. In this system, organics, TN and TP were primarily removed from anoxic tank regardless of the operational conditions.  相似文献   

6.
A high strength industrial wastewater was treated using a pilot scale submerged membrane bioreactor (MBR) at a sludge retention time (SRT) of 200 d. The MBR was operated at a high sludge concentration of 20 g/L and a low F/M ratio of 0.11 during 300 d of operation. It was found that the MBR could achieve COD and TOC overall removal efficiencies at more than 99 and 98% TN removal. The turbidity of the permeate was consistently in the range of 0.123 to 0.136 NTU and colour254 absorbance readings varied from 0.0912 to 0.0962 a.u. cm(-1). The sludge concentration was inversely proportional to the hydraulic retention time (HRT), yielded excellent organic removal and extremely low sludge production (0.0016 kgVSS/day).  相似文献   

7.
The objective of this study was to characterize the mechanisms of the COD removal in the membrane bioreactor (MBR) process with powdered activated carbon (PAC) addition and to determine its optimal operation, for the removal of residual organic matters (ROM) from biologically treated swine wastewater. The MBR process with PAC showed higher removal efficiency of chemical oxygen demand (COD(Mn)) than that without PAC. When the average COD(Mn) concentration of the influent was 217 mg/L, the average COD(Mn) concentration of the permeate from the MBR with PAC was about 41.5 mg/L, indicating an approximate removal efficiency of 81%. On the other hand, the average COD(Mn) concentration of the permeate from the MBR without PAC was 172 mg/L. The PAC dosage estimated to obtain the above removal efficiency was about 0.74 g per litre of influent. Among the total residual organics removed by PAC-added MBR, 46.5% was removed by PAC adsorption, 20.8% by biodegradation, 4.4% by membrane separation, and 9.3% by enhanced microorganism activity. From these results, the MBR process with PAC was considered as a very useful treatment process for the reduction of COD(Mn) in biologically treated swine wastewater.  相似文献   

8.
采用内循环生物流化床系统,进行N、P废水的试验研究,通过控制曝气时间和溶解氧浓度,能同时达到脱氮除磷的效果.对于N、P废水,COD在352~1048 mg/L,TN在46.9~76.4 mg/L,TP在5.8~14.4 mg/L时,COD、TN、TP去除率分别为92%、80%、93%,处理后的水可达到国家二级排放标准.  相似文献   

9.
In TFT-LCD industry, water plays a variety of roles as a cleaning agent and reaction solvent. As good quality water is increasingly a scarce resource and wastewater treatment costs rises, the once-through use of industrial water is becoming uneconomical and environmentally unacceptable. Instead, recycling of TFT-LCD industrial wastewater is become more attractive from both an economic and environmental perspective. This research is mainly to explore the capacity of TFT-LCD industrial wastewater recycling by the process combined with membrane bioreactor and reverse osmosis processes. Over the whole experimental period, the MBR process achieved a satisfactory organic removal. The COD could be removed with an average of over 97.3%. For TOC and BOD5 items, the average removal efficiencies were 97.8 and 99.4% respectively. The stable effluent quality and satisfactory removal performance were ensured by the efficient interception performance of the UF membrane device incorporated with biological reactor. Moreover, the MBR effluent did not contain any suspended solids and the SDI value was under 3. After treatment of RO, excellent water quality of permeate were under 5 mg/l, 2.5 mg/l and 150 micros/cm for COD, TOC and conductivity respectively. The treated water can be recycled for the cooling tower make-up water or other purposes.  相似文献   

10.
In this study, four similar bench-scale submerged Anoxic/Oxic Membrane Bioreactors (MBR) were used simultaneously to investigate the effects of solids retention time (SRT) on organic and nitrogen removal in MBR for treating domestic wastewater. COD removal efficiencies in all reactors were consistently above 94% under steady state conditions. Complete conversion of NH(4+)-N to NO(3-)-N was readily achieved over a feed NH(4+)-N concentration range of 30 to 50 mg/L. It was also observed that SRT did not significantly affect the nitrification in the MBR systems investigated. The average denitrification efficiencies for the 3, 5, 10 and 20 days SRT operations were 43.9, 32.6, 47.5 and 66.5%, respectively. In general, the average effluent nitrogen concentrations, which were mainly nitrate, were about 22.2, 27.6, 21.7 and 13.9 mg/L for the 3, 5, 10 and 20 days SRT systems, respectively. The rate of membrane fouling at 3 days SRT operation was more rapid than that observed at 5 days SRT. No fouling was noted in the 10 days and 20 days SRT systems during the entire period of study.  相似文献   

11.
Nitrogen removal from a piggery wastewater was investigated in a post-denitrification modified Lüdzack Ettinger (PDMLE) process. Overall hydraulic retention time (HRT) of the PDMLE, consisting of contact/separator (C/S), nitrification, denitrification and re-aerobic bioreactor was 10 days. 60% of the influent SCOD was separated in the C/S by contacting the return sludge with the synthetic wastewater, however, only 10% of the influent SCOD was separated from the piggery wastewater. Biosorption capacities of the synthetic wastewater and piggery wastewater were 800 and 150 mg/g-MLSS, respectively. In spite of the high organic and nitrogen load, nitrification efficiency was above 95%, and nitrification rate was about 180 mg-NH4+-N/L x day. The removed delta COD/delta nitrate ratios in the denitrification tank were 4.0 and 11.5 g-SCOD/g-nitrate, while denitrification rates were 8.4 and 2.6 mg-nitrate/day for synthetic and piggery wastewater, respectively. In the proposed PDMLE process, both bio-sorbed and bypassed organic matter could be successfully used for nitrate reduction as carbon sources and the final TN removal efficiency was as high as 95%.  相似文献   

12.
A four stage pilot plant of step-feed biological nutrient removal (BNR) was employed to investigate reactor performance and process stability. The results obtained showed that step-feed BNR is efficient and cost-effective for nitrogen and carbonaceous removal from municipal wastewater. The total average removal efficiencies of COD, NH3-N, TN and TP could reach as high as 89.5, 97.8, 73 and 75%, respectively, with 50% of return activated sludge (RAS), 9 h of hydraulic retention time (HRT) and 20 d of sludge retention time (SRT). Step-feed BNR is an alternative and effective technology of nutrient removal for municipal wastewater treatment.  相似文献   

13.
介绍了用一体式膜生物反应器(M BR)处理焦化废水的技术,讨论了对焦化废水中的COD,NH3-N和浊度的去除效果及影响因素。实验结果表明,一体式膜生物反应器用于处理焦化废水在技术上是可行的,调整合适的操作参数,其对焦化废水中的COD,NH3-N和浊度的平均去除率分别达到80%、95%、90%以上,操作简单,出水水质好,稳定,且优于国家一级排放标准,有一定的推广意义。  相似文献   

14.
改进型合并净化槽处理生活污水的影响因素   总被引:1,自引:0,他引:1  
通过设置改性复合填料和微电解铁屑床对合并净化槽进行工艺改进,采用厌氧(缺氧)好氧(A2/O)工艺处理生活污水。为优化该装置处理生活污水的效果,分别选取水力停留时间、有机负荷、污泥回流比作为运行条件进行试验室中试研究。结合试验结果和经济效益,得出最佳运行条件:水体停留时间为8 h,此时系统对COD、TN和TP的去除率分别为95%、63%8、7%;COD有机负荷为2.7 g/(L.d),该条件下出水COD、TN和TP平均去除率分别可达到90%、74%、88%;污泥回流比为75%,此时净化槽出水COD、TN和TP平均去除率分别达到95%、70%、94%。  相似文献   

15.
A pilot-plant study was conducted to evaluate the performance of a moving-bed biofilm reactor process using PVA-gel beads as a biocarrier. Real primary-settled wastewater was fed to the pre-denitrification system and removals of nitrogenous and organic contaminants were evaluated over a 1-year period. The results demonstrated that at a total nitrogen (TN) loading of 18 mg/L.h, a TN removal efficiency in keeping with and even exceeding the theoretical maximum efficiency based on the level of internal recycle, was possible and a nitrification rate of 15 mg/L.h was sustained with a HRT of only 2.5 h at 15 degrees C. Furthermore, soluble COD and BOD5 in the effluent of the pilot plant were reduced to levels well below most regulatory discharge limits. In addition, the possibility of using this biocarrier in a system, including the elimination of waste organic sludge, was discussed.  相似文献   

16.
Pumped flow biofilm reactors (PFBR) for treating municipal wastewater   总被引:1,自引:0,他引:1  
A novel laboratory bench-scale sequencing batch biofilm reactor (SBBR) system was developed for the treatment of synthetic domestic strength wastewater, comprising two side-by-side 18 l reactor tanks, each containing a plastic biofilm media module. Aerobic and anoxic conditions in the biofilms were effected by intermittent alternate pumping of wastewater between the two reactors. With a media surface area loading rate of 4.2 g chemical oxygen demand (COD)/m2.d, the average influent COD, total nitrogen (TN) and ammonium-nitrogen (NH4-N) concentrations of 1021 mg/l, 97 mg/l and 54 mg/l, respectively, reduced to average effluent concentrations of 72 mg COD/l, 17.8 mg TN/l, and 5.5 mg NH4-N /l. Using a similar alternating biofilm exposure arrangement, a 16 person equivalent pilot (PE) plant was constructed at a local village treatment works to remove organic carbon from highly variable settled municipal wastewater and comprised two reactors, one positioned above the other, each containing a module of cross-flow plastic media with a surface area of 100 m2. Two different pumping sequences (PS) in the aerobic phase were examined where the average influent COD concentrations were 220 and 237 mg/l for PS1 and PS2, respectively, and the final average effluent COD was consistently less than 125 mg/l--the European Urban Wastewater Treatment Directive limit--with the best performance occurring in PS1. Nitrification was evident during both PS1 and PS2 studies. A 300 PE package treatment plant was designed based on the bench-scale and pilot-scale studies, located at a local wastewater treatment works and treated municipal influent with average COD, suspended solids (SS) and TN concentrations of 295, 183 and 15 mg/l, respectively resulting in average effluent concentrations of 67 mg COD/l, 17 mg SS/l and 9 mg TN/l. The SBBR systems performed well, and were simple to construct and operate.  相似文献   

17.
沼液预处理最优混凝搅拌条件的研究   总被引:1,自引:0,他引:1       下载免费PDF全文
通过混凝法对沼液进行预处理最优条件的研究,为沼液预处理提供参考。在实验室条件下,对COD、TN、TP、色度和SS的去除率综合评价混凝工艺效果。实验中依次进行混凝剂投加量、助凝剂投加量、pH和搅拌强度的单因素实验,进而通过正交实验确定沼液预处理最优的混凝搅拌条件。试验结果表明:PAC投加量为4 g/L、PAM投加量为50 mg/L、搅拌速度为200 r/min、混凝阶段同时投加PAC和PAM,处理后的水样COD、TN、TP、色度和SS分别为216.20、181.99、0.18、11.77和71.67 mg/L,去除率分别达到92.51%、88.85%、99.75%、98.37%和89.46%,达到畜禽养殖业污染物排放标准(GB18596-2001),减轻了后续污水处理的负荷,为沼液实际处理提供了理论支持。  相似文献   

18.
针对人工湿地中有机碳源不足造成脱氮效率较差的问题,寻找更高效的植物碳源以改善人工湿地内部碳氮比低的状况。通过试验比较芦苇穗(芦穗)、芦苇茎(芦茎)和芦苇根(芦根)3个部位在不同预处理方式下的静态释放规律,筛选出最佳的植物碳源,并通过小试人工湿地试验分析其作为植物碳源对脱氮效果的影响。分析结果表明:碱热处理能够提高COD释放量,相较其它预处理方式,其最大COD释放浓度提高10%,并提前释放一部分氮类化合物和含磷化合物;芦穗碱热处理初期COD释放量达到各部位中的最高值182.00 mg/L;从144 h内的平均TN释放量来看,芦穗碱热处理(6.16 mg/L)>芦根碱热处理(4.21 mg/L)>芦茎碱热处理(2.99 mg/L),芦茎释放量最少,比芦穗少一半以上;经过碱泡、碱热处理后,TN、TP、NH+4-N、NO-3-N和NO-2-N释放量均小于简单处理。碱热处理后的芦苇茎是最佳植物碳源,具有较强的持续释碳能力,并且对氮、磷积累的影响最小;在小试人工湿地系统中添加碱热处理后的芦茎在不显著提高系统出水COD前提下,显著提高了TN和TP的去除率,相对对照组分别提高了61.14%和32.53%,达到同步强化脱氮除磷的效果。  相似文献   

19.
Three parallel biological anoxic filters (BaFs) were operated to investigate the denitrification kinetics of methanol, brewery wastewater and bakery wastewater. The experiment was conducted within the temperature range of 15-20 °C, with an influent nitrate and carbon dosage of 30 mg/L and 150 mg COD/L (COD: chemical oxygen demand). The denitrification efficiencies of brewery wastewater, bakery wastewater and methanol were 84, 66 and 74%, specific denitrification rates were 1.44, 1.11 and 1.24 kg NO(3)-N/m(3) d, and total nitrogen (TN) removal rates were 74, 62 and 66%, respectively. The volatile attached solid (VAS) tests reveal that methanol has the minimum net biomass yield, so it needs the least carbon to nitrogen (expressed in COD to nitrate, C/N) ratio for complete denitrification. While the brewery wastewater and bakery wastewater need higher C/N ratio to remove all nitrate nitrogen, and they both may need pretreatment to remove phosphate when used as external carbon sources.  相似文献   

20.
A protocol to select nutrient removal technologies that can achieve low nutrient effluents (total nitrogen (TN) < 5 mg/L and total phosphorus (TP) < 0.5 mg/L) was developed for different wastewater treatment plant (WWTP) sizes based on the research conducted during a Water Environment Research Foundation funded project. The adaptable protocol includes technology and cost assessment of feasible (pre-screened) nutrient removal technologies that are being successfully implemented at full scale. The information collected from the full scale nutrient removal plants to develop this protocol includes design, operational, performance, and cost data through a direct survey of plants, and published data. The protocol includes a "technology threshold" approach consisting of Tier I (TN < 5.0 mg/L; TP < 0.5 mg/L) and Tier II (TN < 3.0 mg/L; TP < 0.1 mg/L) effluent nutrient levels for different plant sizes. A very large WWTP (1,250,000 m(3)/day flow) in Chicago, Illinois, USA adapted this protocol for master planning and design of future nutrient removal facilities based on plant and site specific criteria.  相似文献   