首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Chen H  He M  Pei J  He H 《Analytical chemistry》2003,75(23):6531-6535
Quantitative analyses of synthetic polymers were accomplished using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI TOF MS). Many factors have hindered the development of quantitative measurement of polymers via MALDI TOF MS, e.g., laser power, matrix, cation salt, and cocrystallization. By probing the optimal conditions, two sets of polymers were studied. Fair repeatability of the samples ensures acceptable results. In set 1, two poly(ethylene glycols) with different end groups showed equal desorption/ionization efficiencies. Two synthetic polymers in set 2 with different chemical properties resulted in different MALDI responses. Good linearity was achieved by plotting the relationship between the sample concentration ratio and the total signal intensity ratio in both sets.  相似文献   

2.
Microcystins (MCs) are a growing problem in drinking water supplies worldwide. Common analytical techniques used to determine MC concentrations have several shortcomings, including extensive sample handling and lengthy analysis times. A simple, rapid method for quantitation of MCs by matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) is presented. Four potential internal standards were tested, including an 15N-labeled MC. For MC-LR in mixed standard solutions, a linear range of 0.11-5.0 microM (R2 = 0.98) was achieved, with a method detection limit (MDL) of 0.015 microM. Matrix effects due to extracted cell components decreased the MC-LR linear range slightly to 0.19-5.0 microM (R2 = 0.99), with MDL = 0.058 microM. Extensive analysis of possible internal standards indicates that nodularin was preferred over [15N]10-microcystin-YR or angiotensin I. The ionization efficiency and analyte-analyte suppression for four MCs of varying polarity are presented; the three polar congeners exhibited good ionization efficiency and acceptable levels of analyte-analyte suppression. These results indicate that MALDI-TOF MS represents a viable alternative for the quantitative measurement of MCs in field samples.  相似文献   

3.
Thermal field-flow fractionation (ThFFF) and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) have been coupled to yield a powerful combination of techniques for polymer analysis. Thermal FFF's high molecular weight (MW) selectivity and sensitivity to chemical composition are used to separate polydisperse polymers and polymer mixtures into the narrow polydispersity and homogeneous chemical composition fractions essential for MALDI-TOFMS analyses. On the other hand, MALDI-TOFMS's ability to directly measure molecular weight alleviates the need for polymer standards for ThFFF. In this first-time coupling of ThFFF and MALDI-TOFMS, compatibility issues were addressed and optimum conditions and procedures were identified and developed to maximize the capabilities of the combined technique. Depending on the polymer MW and the method of MALDI sample deposition, fractions from 1-10 ThFFF runs were combined for MALDI-TOFMS analysis. Binary solvents were used to enhance ThFFF retention and resolution of low-MW (<15-kDa) polymers, and methods were developed to allow routine MALDI-TOFMS analyses of polystyrene polymers up to 575 kDa. Overall, the MW compatibility of the two techniques was extended from several kilodaltons to several hundred kilodaltons. Polymer fractions were collected after separation by ThFFF and analyzed either by MALDI-TOFMS or reinjection into the ThFFF system. Good agreement was observed between the MW distribution data obtained by MALDI-TOFMS and ThFFF. The application of ThFFF/MALDI-TOFMS to polydisperse polymers and polymer mixtures was demonstrated. This combined technique was also shown to be a viable means for preparing standards from the original polymer sample.  相似文献   

4.
Chen H  He M  Pei J  Liu B 《Analytical chemistry》2002,74(24):6252-6258
An analytical method based on matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been applied to provide information on the structure of a copolymer, e.g., repeat unit and end group. Seven conjugated polymers, which have been demonstrated as the active component in blue light-emitting diodes, were synthesized through Suzuki polycondensation reaction in the presence of Pd(PPh3)4 catalyst. Their molecular weights were obtained using gel permeation chromatography analysis. MALDI-TOF MS was used to investigate the structure information in detail. The proposed end-group structures were confirmed by the identity between the observed and the simulated isotopic distribution of each polymer. The results demonstrate that these synthetic polymers possess various end groups and even contain macrocycles. The catalyst Pd(PPh3)4 was found to introduce phenyl end groups via aryl-aryl exchange between the catalytic palladium intermediate and the triphenylphosphine ligand. All these results are based on the analysis of the mass spectrum data, which suggests that MALDI-TOF MS is an extraordinarily strong tool in synthetic polymer structure analysis.  相似文献   

5.
A new technique for preparing samples for matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is reported. The technique relies on electrowetting-on-dielectric (EWOD) to move droplets containing proteins or peptides and matrix to specific locations on an array of electrodes for analysis. Standard MALDI-MS reagents, analytes, concentrations, and recipes are demonstrated to be compatible with the technique. Mass spectra are comparable to those collected by conventional methods. Nonspecific adsorption of analytes to device surfaces is demonstrated to be negligible. The results suggest that EWOD may be a useful tool for automating sample preparation for high-throughput proteomics and other applications of MALDI-MS.  相似文献   

6.
A novel approach to rapid bacterial detection using an isotopically labeled (15)N bacteriophage and matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry (MALDI-TOF MS) is introduced. Current phage amplification detection (PAD) via mass spectrometric analysis is limited because host bacteria must be inoculated with low phage titers in such a way that initial infecting phage concentrations must be below the detection limit of the instrument, thus lengthening incubation times. Additionally, PAD techniques cannot distinguish inoculate input phage from output phage which can increase the possibility of false positive results. Here, we report a rapid and accurate PAD approach for identification of Staphylococcus aureus via detection of bacteriophage capsid proteins. This approach uses both a wild-type (14)N and a (15)N-isotopically labeled S. aureus-specific bacteriophage. High (15)N phage titers, above our instrument's detection limits, were used to inoculate S. aureus. MALDI-TOF MS detection of the (14)N progeny capsid proteins in the phage-amplified culture indicated the presence of the host bacteria. Successful phage amplification was observed after 90 min of incubation. The amplification was observed by both MALDI-TOF MS analysis and by standard plaque assay measurements. This method overcomes current limitations by improving analysis times while increasing selectivity when compared to previously reported PAD methodologies.  相似文献   

7.
The analysis of hydrophobic and hydrophilic peptides in an aqueous medium using matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is reported. The key development allowing for simultaneous analysis of both hydrophobic and hydrophilic components of the sample mixture is the use of surfactants to solubilize the hydrophobic components in the MALDI matrix solution. A wide variety of anionic, cationic, zwitterionic, and nonionic surfactants were evaluated for their ability to assist in the generation of an abundant pseudomolecular ion from a model hydrophobic peptide ([tert-butoxycarbonyl]Glu[gamma-O-benzyl]-Ala-Leu-Ala[O-phenacyl ester]). The results indicate that the most successful surfactant among those studied for analyzing the model hydrophobic peptide is sodium dodecyl sulfate (SDS). SDS exhibited no interfering surfactant background ions, little to no loss of the acid-labile protecting groups from the model hydrophobic peptide, and an abundant pseudomolecular ion of the analyte. In addition, the use of surfactants is shown to be compatible with hydrophilic peptides as well. Mixtures of hydrophobic and hydrophilic peptides were characterized using surfactant-aided (SA) MALDI-MS, and it is demonstrated that all components are detectable once the surfactant is included in the sample solution. We conclude that the key benefit of using SA-MALDI-MS is its ability to simultaneously analyze hydrophobic and hydrophilic peptides from a single sample mixture, including synthetic peptides containing acid- and base-labile protecting groups.  相似文献   

8.
A novel ionization source for biological mass spectrometry is described that combines atmospheric pressure (AP) ionization and matrix-assisted laser desorption/ionization (MALDI). The transfer of the ions from the atmospheric pressure ionization region to the high vacuum is pneumatically assisted (PA) by a stream of nitrogen, hence the acronym PA-AP MALDI. PA-AP MALDI is readily interchangeable with electrospray ionization on an orthogonal acceleration time-of-flight (oaTOF) mass spectrometer. Sample preparation is identical to that for conventional vacuum MALDI and uses the same matrix compounds, such as alpha-cyano-4-hydroxycinnamic acid. The performance of this ion source on the oaTOF mass spectrometer is compared with that of conventional vacuum MALDI-TOF for the analysis of peptides. PA-AP MALDI can detect low femtomole amounts of peptides in mixtures with good signal-to-noise ratio and with less discrimination for the detection of individual peptides in a protein digest. Peptide ions produced by this method generally exhibit no metastable fragmentation, whereas an oligosaccharide ionized by PA-AP MALDI shows several structurally diagnostic fragment ions. Total sample consumption is higher for PA-AP MALDI than for vacuum MALDI, as the transfer of ions into the vacuum system is relatively inefficient. This ionization method is able to produce protonated molecular ions for small proteins such as insulin, but these tend to form clusters with the matrix material. Limitations of the oaTOF mass spectrometer for singly charged high-mass ions make it difficult to evaluate the ionization of larger proteins.  相似文献   

9.
Argentinated peptide ions are formed in abundance under matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) conditions in the presence of Ag+ ions. These argentinated peptide ions are fragmented facilely under MALDI-MS/MS conditions to yield [b(n) + OH + Ag]+, [b(n) - H + Ag]+ and [a(n) - H + Ag]+ ions that are indicative of the C-terminal sequence. These observations parallel those made earlier under electrospray MS conditions (Chu, I. K; Guo, X.; Lau, T.-C.; Siu, K W. M. Anal. Chem. 1999, 71, 2364-2372). A mixed protonated and argentinated tryptic peptide map was generated from 37 fmol of bovine serum albumin (BSA) using MALDI-MS. MALDI-MS/MS data from four argentinated peptides at a protein amount of 350 fmol unambiguously identified the protein as BSA. Sequence-tag analysis of two argentinated tryptic peptides was used to identify unambiguously myocyte enhancer factor 2A, which had been recombinantly expressed in a bacterial cell line.  相似文献   

10.
Application of mass spectrometry imaging (MS imaging) analysis to single cells was so far restricted either by spatial resolution in the case of matrix-assisted laser desorption/ionization (MALDI) or by mass resolution/mass range in the case of secondary ion mass spectrometry (SIMS). In this study we demonstrate for the first time the combination of high spatial resolution (7 μm pixel), high mass accuracy (<3 ppm rms), and high mass resolution (R = 100?000 at m/z = 200) in the same MS imaging measurement of single cells. HeLa cells were grown directly on indium tin oxide (ITO) coated glass slides. A dedicated sample preparation protocol was developed including fixation with glutaraldehyde and matrix coating with a pneumatic spraying device. Mass spectrometry imaging measurements with 7 μm pixel size were performed with a high resolution atmospheric-pressure matrix-assisted laser desorption/ionization (AP-MALDI) imaging source attached to an Exactive Orbitrap mass spectrometer. Selected ion images were generated with a bin width of Δm/z = ±0.005. Selected ion images and optical fluorescence images of HeLa cells showed excellent correlation. Examples demonstrate that a lower mass resolution and a lower spatial resolution would result in a significant loss of information. High mass accuracy measurements of better than 3 ppm (root-mean-square) under imaging conditions provide confident identification of imaged compounds. Numerous compounds including small metabolites such as adenine, guanine, and cholesterol as well as different lipid classes such as phosphatidylcholine, sphingomyelin, diglycerides, and triglycerides were detected and identified based on a mass spectrum acquired from an individual spot of 7 μm in diameter. These measurements provide molecularly specific images of larger metabolites (phospholipids) in native single cells. The developed method can be used for a wide range of detailed investigations of metabolic changes in single cells.  相似文献   

11.
A method for obtaining protein molecular masses with an accuracy of approximately +/- 0.01% by matrix-assisted laser desorption using an internal calibrant is described. The technique allows accurate mass determinations of protein sample sizes as small as 1 pmol. High concentrations of organic and inorganic contaminants (e.g. 1 M urea) do not strongly affect either the signal intensity or the mass assignment. The ability to assign an accurate molecular mass to a protein is contingent on the observation of clearly resolved protonated molecule ions in the mass spectrum.  相似文献   

12.
A new high-pressure matrix-assisted laser desorption/ionization (HP-MALDI) source for FTMS has recently been described (O'Connor et al. J. Am. Soc. Mass Spectrom., in press). Improvements to the source design, including the incorporation of a new high-pressure gas channel plate, resulted in ions devoid of metastable fragmentation and also in increased sensitivity compared to the HP-MALDI prototype source design. The focus of this contribution is the evaluation of the current HP-MALDI FTMS configuration. The use of nonconductive sample surfaces, such as Parafilm and Teflon, was explored, and spectra from 30 amol of peptide applied to these surfaces were routinely obtained. In addition, the current limit of detection for this configuration is demonstrated to be 300 zmol for the phosphopeptide RRREEE(pS)EEEAA using multishot accumulation of the ions from 15 laser shots in the hexapole and 1 scan. In addition, the performance of the new HP-MALDI FTMS configuration and its potential application for high-throughput proteomics analyses are discussed.  相似文献   

13.
YJ Bae  KM Park  MS Kim 《Analytical chemistry》2012,84(16):7107-7111
Matrix-assisted laser desorption ionization of peptides was investigated using α-cyano-4-hydroxycinnamic acid as the matrix. In each experiment, a set of mass spectra was collected by repetitive irradiation of a spot on a sample. Even though shot-to-shot variation in spectral pattern was significant, it was reproducible for different spots and samples. Each spectrum was tagged with the temperature in the early plume (T(early)) estimated through kinetic analysis of the peptide ion survival probability. T(early) decreased as the shot continued because the thermal conduction got more efficient as the sample got thinner. From each spectral set collected under various experimental conditions, a spectrum tagged with a particular T(early) was selected. Then, patterns of the spectra thus selected were the same. The reaction quotient for the matrix-to-peptide proton transfer determined at a specified T(early) was independent of the sample composition, indicating quasi-thermal equilibrium for this reaction. Furthermore, the van't Hoff plots were linear, also indicating quasi-thermal equilibrium. This, together with the thermal kinetics for the fragmentation of peptide and matrix ions, is responsible for the reproducibility of the mass spectral pattern at a specified T(early).  相似文献   

14.
Accurate and reproducible quantification of glycans from protein drugs has become an important issue for quality control of therapeutic proteins in biopharmaceutical and biotechnology industries. Mass spectrometry is a promising tool for both qualitative and quantitative analysis of glycans owing to mass accuracy, efficiency, and reproducibility, but it has been of limited success in quantitative analysis for sialylated glycans in a high-throughput manner. Here, we present a solid-phase permethylation-based total N-glycan quantitative method that includes N-glycan releasing, purification, and derivatization on a 96-well plate platform. The solid-phase neutralization enabled us to perform reliable absolute quantification of the acidic N-glycans as well as neutral N-glycans from model glycoproteins (i.e., chicken ovalbumin and porcine thyroglobulin) by only using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). Furthermore, low-abundance sialylated N-glycans from human serum prostate specific antigen (PSA), an extremely valuable prostate cancer marker, were initially quantified, and their chemical compositions were proposed. Taken together, these results demonstrate that our all-inclusive glycan preparation method based on a 96-well plate platform may contribute to the precise and reliable qualitative and quantitative analysis of glycans.  相似文献   

15.
A rapid, simple, and reliable gender determination of human DNA samples was successfully obtained using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. Detection sensitivity reached 0.01 ng or less for DNA samples.  相似文献   

16.
Room-temperature ionic liquids are useful as solvents for organic synthesis, electrochemical studies, and separations. We wished to examine whether their high solubalizing power, negligible vapor pressure, and broad liquid temperature range are advantageous if they are used as matrixes for UV-MALDI. Several different ionic matrixes were synthesized and tested, using peptides, proteins, and poly(ethylene glycol) (PEG-2000). All ionic liquids tested have excellent solubilizing properties and vacuum stability compared to other commonly used liquid and solid matrixes. However, they varied widely in their ability to produce analyte gas-phase ions. Certain ionic matrixes, however, produce homogeneous solutions of greater vacuum stability, higher ion peak intensity, and equivalent or lower detection limits than currently used solid matrixes. Clearly, ionic liquids and their more amorphous solid analogues merit further investigation as MALDI matrixes.  相似文献   

17.
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is a powerful analytical tool for the structural characterization of proteins and nucleic acids. However, many proteomics or genomics methodologies that employ MALDI-MS require external sample manipulation, which limits the overall throughput of analysis. We have focused on fabricating functional MALDI sample plates that would permit the on-probe characterization of nucleic acids. Here, we present results arising from the fabrication of functional sample plates composed of poly(methyl methacrylate) (PMMA). The PMMA sample plates were fabricated by a CNC milling technique. The key structural feature of our microfabricated samples plates is the presence of individual cylindrical posts (360 microm x 360 microm), which serve as individual sample targets within the overall PMMA-based MALDI sample plate. Functionality is added to these microposts via the covalent attachment of enzymes. As an example of the applicability of these microfabricated sample plates, enzymatic digestion of ribonucleic acids was performed on probe (i.e., on the micropost) with subsequent analysis by MALDI-MS. Advantages to such an approach include a reduction in sample handling (and concomitant sample losses) and a reduction in the amount of sample required for analysis due to the small surface area of the microposts.  相似文献   

18.
Many different laboratories are currently developing mass-spectrometric techniques to analyze and identify microorganisms. However, minimal work has been done with mixtures of bacteria. To demonstrate that microbial mixtures could be analyzed by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS), mixed bacterial cultures were analyzed in a double-blind fashion. Nine different bacterial species currently in our MALDI-MS fingerprint library were used to generate 50 different simulated mixed bacterial cultures similar to that done for an initial blind study previously reported (Jarman, K. H.; Cebula, S. T.; Saenz, A. J.; Petersen, C. E.; Valentine, N. B.; Kingsley, M. T.; Wahl, K. L. Anal. Chem. 2000, 72, 1217-1223). The samples were analyzed by MALDI-MS with automated data extraction and analysis algorithms developed in our laboratory. The components present in the sample were identified correctly to the species level in all but one of the samples. However, correctly eliminating closely related organisms was challenging for the current algorithms, especially in differentiating Serratia marcescens, Escherichia coli, and Yersinia enterocolitica, which have some similarities in their MALDI-MS fingerprints. Efforts to improve the specificity of the algorithms are in progress.  相似文献   

19.
A highly sensitive method to analyze the intact lipids in a single zooplankter individual at the level of a few tenths of a microgram was developed by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) combined with a direct sampling technique. The sampling procedure involved (1) putting a zooplankter individual sample onto the MALDI sample plate, (2) cutting the sample into a few pieces by means of tweezers, (3) depositing aliquots of matrix and cationization reagent solutions on the zooplankter sample, and (4) irradiating with a N2 laser to cause MALDI. By using this technique, the mass spectra of the single zooplankter samples showed a series of ions generated from phospholipids with 34 or 36 carbons in the acyl groups and neutral lipids such as triglycerides and diacylglyceryl ethers with 50-54 carbons in their acyl and alkenyl groups. Accordingly, this method enabled us to estimate the relative quantity between "structured lipids" (phospholipids) and "storage lipids" (neutral lipids) in an individual zooplankter, which should give us a good clue to elucidate the roles of each class of lipids in its growth.  相似文献   

20.
The lipid peroxidation product 4-hydroxy-2-nonenal (HNE) is generated as a consequence of oxidative stress and can readily react with nucleophilic sites of proteins (e.g., histidine residues), mainly via a Michael addition. The formation of such lipid-protein conjugates can alter protein properties and biological functions, thus leading to highly deleterious effects. The present work describes a rapid (very limited sample preparation) and sensitive (low-femtomole range) procedure to identify HNE-modified peptides (Michael adducts) within unfractionated tryptic digests. The protocol involves the formation of dinitrophenylhydrazones of the Michael adducts, when using 2,4-dinitrophenylhydrazine as reactive matrix, followed by analysis using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). The hydrazone derivatives present high desorption/ionization yield and can thus be preferentially detected compared to unmodified peptides. The MALDI mass spectrum obtained is therefore drastically different from the one obtained with the classical 4-hydroxy-alpha-cyanocinnamic acid matrix. Moreover, the presence of HNE, or more generally speaking carbonylated peptides, could be highlighted by 180 mass units differences (corresponding to the dinitrophenylhydrazone moiety) between these two MALDI mass spectra. Further information (e.g., localization/identification of the modified residues, peptide sequences) could be obtained by performing MALDI postsource decay (or electrospray) MS/MS experiments on the ions of interest.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号