首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 609 毫秒
1.
EPR dose reconstruction after accidental photon exposure based on materials irradiated in the vicinity of the victim (sucrose, medicine tablets, etc.) was used successfully in several cases referenced in the literature. However, accidental exposure may also occur with a neutron component such as in the Tokai-Mura criticality accident. The aim of this work is to investigate the potentiality of EPR dosimetry for mixed photon and neutron field exposure with different organic materials already used for photon exposure (sucrose) or with potential dosimetric properties (ascorbic acid, sorbitol, glucose, galactose, fructose, lactose and mannose). To assess the neutron sensitivity, the materials were exposed to a mixed radiation field of an experimental reactor with different neutron to photon ratios. The relative neutron sensitivity was found to range from 12 to 43% according to the materials. The potentiality of these materials for mixed field EPR dosimetry is discussed.  相似文献   

2.
The objective of the Third International Intercomparison on EPR Tooth Dosimetry was to evaluate laboratories performing tooth enamel dosimetry <300 mGy. Final analysis of results included a correlation analysis between features of laboratory dose reconstruction protocols and dosimetry performance. Applicability of electron paramagnetic resonance (EPR) tooth dosimetry at low dose was shown at two applied dose levels of 79 and 176 mGy. Most (9 of 12) laboratories reported the dose to be within 50 mGy of the delivered dose of 79 mGy, and 10 of 12 laboratories reported the dose to be within 100 mGy of the delivered dose of 176 mGy. At the high-dose tested (704 mGy) agreement within 25% of the delivered dose was found in 10 laboratories. Features of EPR dose reconstruction protocols that affect dosimetry performance were found to be magnetic field modulation amplitude in EPR spectrum recording, EPR signal model in spectrum deconvolution and duration of latency period for tooth enamel samples after preparation.  相似文献   

3.
The use of electron paramagnetic resonance (EPR) tooth dosimetry for calculation of organ doses requires conversion of the measured absorbed dose in enamel. Before deriving conversion factors from simulation calculations with a realistic anthropomorphic human phantom, in the current study a simplified phantom was chosen to compare EPR measurement and Monte Carlo calculation. The dose response of tooth enamel of molars at various positions inside a cylindrical Plexiglas phantom of head-size was calculated hy Monte Carlo modelling in parallel photon beams of X rays of 63 keV equivalent energy and 60Co gamma rays (1.25 Mev). For X ray exposure, preliminary results of EPR dosimetry with tooth enamel samples prepared from molars irradiated in the phantom were in agreement with calculation. The mean value of the ratio of the measured to the calculated dose was 0.93 +/- 0.08.  相似文献   

4.
This paper addresses issues in the application of the electron paramagnetic resonance (EPR) retrospective dosimetry with dental tissues exposed by radionuclides accumulated in the dentin. A simple dosimetric model of a tooth incorporating 90Sr is presented. The tooth is modelled as two concentric cylinders: the inner cylinder composed of dentin, and the outer cylindrical shell of enamel. Extensive Monte Carlo calculations were done to obtain the distributions of absorbed dose in dentin and enamel for teeth of different sizes. The results were used to calculate the mean absorbed doses in enamel that are directly measurable by EPR. A relationship between such measured doses and the specific activity of 90Sr in dentin was derived based on a simple model of 90Sr accumulation. The roles of different tooth tissues as dose detectors are analysed, and the importance of dentin as a dosimetric material for internal exposure is pointed out.  相似文献   

5.
Micro and nano-structure hydroxyapatite samples were synthesized via several different methods. The samples were characterised utilising the Fourier transmission infra-red, scanning electron microscope and X-ray diffraction methods, to find out the structure most similar to human tooth enamel, and the best method was found. The electron paramagnetic resonance (EPR) signals of the gamma-irradiated samples were measured using an EPR spectrometer system. A calibration curve was established by irradiation of the samples at four doses of 50-500 mGy. The parameters of the calibration curve, slope and intercept with dose axis are determined by linear regression analysis. This calibration curve can be used for human tooth enamel for retrospective dosimetry purposes.  相似文献   

6.
Electron Paramagnetic Resonance dosimetry based on tooth enamel has one important application in dose reconstruction of nuclear plant workers, where the contribution of neutrons to individual dose is often important. Evaluation of tooth enamel response to neutrons is thus an important goal. A few experimental data at thermal and fast neutron energies are available. A first evaluation of the tooth enamel relative response to 60Co in monoenergetic neutron flux of 2.8 and of 14 MeV, published elsewhere, has provided results apparently non-consistent with the results obtained at lower and higher energies. A comparison of those results in the 2.8 and 14 MeV beams with those available in the literature for other beams is reported and possible reasons for incongruities are discussed. Dose conversion factors of enamel to the water and air are also calculated and reported.  相似文献   

7.
The electron paramagnetic resonance (EPR, or electron spin resonance) method was used to measure CO??· radicals recorded in tooth enamel by exposure to atomic-bomb gamma rays. The EPR-estimated doses (i.e. ??Co gamma-ray equivalent dose) were generally in good correlation with cytogenetic data of the same survivors, whereas plots of EPR-estimated dose or cytogenetically estimated dose against DS02 doses turned out to scatter more widely. Because those survivors whose EPR doses were higher (or lower) than DS02 doses tended to show also higher (or lower) responses for cytogenetic responses, the apparent variation appears primarily due to problems in individual DS02 doses rather than the measurement errors associated with the EPR or cytogenetic technique. A part of the enamel samples were also used for evaluation of neutron doses by measuring ?1Ca/??Ca ratios using the accelerator mass spectrometry technique. The results for the measured ratios were on average ~85 % of the calculated ratios by DS02 (but within the 95 % confidence bounds of the simulated results), which lends support to DS02-derived neutron doses to the survivors.  相似文献   

8.
The dose profiles in molar teeth from diagnostic X rays was calculated using the Monte Carlo software program MCNP4c2. The information calculated supports needs in EPR retrospective dosimetry to account for diagnostic X ray exposures in teeth. Only tooth positions 6, 7 and 8 were simulated (the three teeth furthest back including the wisdom teeth) using a very detailed model of the pertinent physiology. The lingual and buccal halves of teeth were evaluated as were the crown dentin and roots in tooth position 7. Linear dose profiles through the enamel were also calculated.  相似文献   

9.
An analysis of doses to tooth enamel and to organs was carried out to develop a method that can predict the organ doses and the effective dose by electron spin resonance (ESR) dosimetry using tooth samples for external photon exposure. Absorbed dose to tooth enamel and organ doses were obtained by Monte Carlo calculations using the EGS4 code in combination with a mathematical human model with a newly defined teeth part. The calculations gave quantitative relations between tooth enamel dose and organ doses for some cases of external photon exposure. It was also found that tooth enamel dose depends more significantly on energy of incident photons than the other organ dose or the effective dose. The obtained data are to be useful for the assessment of individual dose in past exposure events by the ESR dosimetry using tooth enamel.  相似文献   

10.
Dose conversions were studied for dosimetry of atomic bomb survivors based upon electron spin resonance (ESR) measurements of tooth enamel. Previously analysed data had clarified that the tooth enamel dose could be much larger than other organ doses from a low-energy photon exposure. The radiation doses to other organs or whole-body doses, however, are assumed to be near the tooth enamel dose for photon energies which are dominant in the leakage spectrum of the Hiroshima atomic bomb assumed in DS02. In addition, the thyroid can be a candidate for a surrogate organ in cases where the tooth enamel dose is not available in organ dosimetry. This paper also suggests the application of new Japanese voxel phantoms to derive tooth enamel doses by numerical analyses.  相似文献   

11.
Electron paramagnetic resonance dosimetry with tooth enamel has been proved to be a reliable method to determine retrospectively exposures from photon fields with minimal detectable doses of 100 mGy or lower, which is lower than achievable with cytogenetic dose reconstruction methods. For risk assessment or validating dosimetry systems for specific radiation incidents, the relevant dose from the incident has to be calculated from the total absorbed dose in enamel by subtracting additional dose contributions from the radionuclide content in teeth, natural external background radiation and medical exposures. For calculating organ doses or evaluating dosimetry systems the absorbed dose in enamel from a radiation incident has to be converted to air kerma using dose conversion factors depending on the photon energy spectrum and geometry of the exposure scenario. This paper outlines the approach to assess individual dose contributions to absorbed dose in enamel and calculate individual air kerma of a radiation incident from the absorbed dose in tooth enamel.  相似文献   

12.
The experimental energy dependence of the electron paramagnetic resonance (EPR) radiation-induced signal at irradiation by photons in the energy range of 13 keV-1.25 MeV was analysed in terms of the absorbed dose in human tooth enamel. The latter was calculated using a Monte Carlo simulation of the photon and electron transport. The dependence of the calculated absorbed dose on the sample thickness was analysed. No energy dependence of the EPR signal on the absorbed dose in enamel was verified in the range of 37 keV-1.25 MeV. At 13 and 20 keV the EPR signal dose response was reduced by 8% probably due to sample powdering. Dose-depth profiles in enamel samples irradiated by 1.25 MeV photons in polymethylmethacrylate and aluminium build-up materials were calculated. It was concluded that secondary electron equilibrium conditions are better fulfilled for irradiation in aluminium, which makes this material preferable for calibration.  相似文献   

13.
Two criticality dosimetry systems were tested by Czech participants during the intercomparison held in Valduc, France, June 2002. The first consisted of the thermoluminescent detectors (TLDs) (Al-P glasses) and Si-diodes as passive neutron dosemeters. Second, it was studied to what extent the individual dosemeters used in the Czech routine personal dosimetry service can give a reliable estimation of criticality accident exposure. It was found that the first system furnishes quite reliable estimation of accidental doses. For routine individual dosimetry system, no important problems were encountered in the case of photon dosemeters (TLDs, film badge). For etched track detectors in contact with the 232Th or 235U-Al alloy, the track density saturation for the spark counting method limits the upper dose at approximately 1 Gy for neutrons with the energy >1 MeV.  相似文献   

14.
Personal neutron dosimetry is quite a difficult area because a neutron is always accompanied with gamma radiation, which is required of a capability for mixed field dosimetry. CaSO4:Dy phosphor is known to have a very high sensitivity to gamma radiation, but the neutron capture cross section of the constituents of CaSO4:Dy are so small that the interactions between the thermal neutron and the phosphor are rare. One method to improve the neutron interaction is by introducing an impurity ion with a large thermal neutron captures cross section into the phosphor to act as a neutron target centre such as 6Li. In neutron-gamma mixed radiation fields, if two detectors for the 6Li-7Li compounds embedded CaSO4:Dy thermoluminescent (TL) pellets are used, a 6Li-compound embedded pellet can detect the neutron and gamma radiations together, and the other pellet can only detect the gamma radiation. Recently, the Korea Atomic Energy Research Institute (KAERI) has developed a new type of CaSO4:Dy TL materials embedded with phosphorous (KCT-300) to detect beta and gamma radiation with a very high sensitivity. This paper presents the development of CaSO4:Dy TL pellets embedded with 6Li compound for a thermal neutron measurement, and the detection method of the neutron and gamma dose in mixed fields with CaSO4:Dy TL pellets embedded with a 6Li compound (KCT-306) and CaSO4:Dy TL pellets embedded with a 7Li compound (KCT-307) is introduced. The net neutron sensitivity of CaSO4:Dy TL pellets embedded with 6Li compound developed in this study is about two times higher than that of the TLD-600 (Harshaw Chemical) dosemeter which is available commercially.  相似文献   

15.
An international intercomparison of criticality accident dosimetry systems took place in the SILENE reactor, in June 2002. Participants from 60 laboratories irradiated their dosemeters (physical and biological) using two different configurations of the reactor. In preparation for this intercomparison, the leakage radiation fields were characterised by spectrometry and dosimetry measurements using the ROSPEC spectrometer associated with a NE-213 scintillator, ionisation chambers, GM counters, diodes and thermoluminescence dosemeters (TLDs). For this intercomparison, a large area was required to irradiate the dosemeters both in free air and on phantoms. Therefore, measurements of the uniformity of the field were performed with activation detectors and TLDs for neutron and gammas, respectively. This paper describes the procedures used and the results obtained.  相似文献   

16.
In criticality accident dosimetry and more generally for high dose measurements, special techniques are used to measure separately the gamma ray and neutron components of the dose. To improve these techniques and to check their dosimetry systems (physical and/or biological), a total of 60 laboratories from 29 countries (America, Europe, Asia) participated in an international intercomparaison, which took place in France from 9 to 21 June 2002, at the SILENE reactor in Valduc and at a pure gamma source in Fontenay-aux-Roses. This intercomparison was jointly organised by the IRSN and the CEA with the help of the NEA/OCDE and was partly supported by the European Communities. This paper describes the aim of this intercomparison, the techniques used by the participants and the two radiation sources and their characteristics. The experimental arrangements of the dosemeters for the irradiations in free air or on phantoms are given. Then the dosimetric quantities measured and reported by the participants are summarised, analysed and compared with the reference values. The present paper concerns only the physical dosimetry and essentially experiments performed on the SILENE facility. The results obtained with the biological dosimetry are published in two other papers of this issue.  相似文献   

17.
In this paper, the results of a study on the electron spin resonance (ESR) dosimetry to measure thermal neutron fluence in a mixed radiation field (neutron and photons) are presented. The ESR responses of alanine dosemeters with different additives are compared. In particular, the (10)B-acid boric and the Gd-oxide were chosen to enhance the sensitivity of alanine dosemeters to thermal neutrons. Irradiations were carried out inside the thermal column of the TAPIRO reactor of the ENEA center, Casaccia Rome. The main results are a greater neutron sensitivity and a smaller lowest detectable fluence for the dosemeters with gadolinium than for dosemeters of alanine with (10)B, which is well known to be much more sensitive to thermal neutrons than simple alanine.  相似文献   

18.
Regarding in vivo L-band dosimetry with human teeth, a number of preliminary experiments were carried out that were linked to the resonators response and the relative contribution of enamel to the EPR signal intensity of irradiated whole teeth. The sensitivity of the extended loop resonator varies in the antenna plane, but this variation tends to vanish when the sample is moved away from this plane. When the loop antenna is placed just above the highly irradiated molar, around 88% of the dosimetric signal is due to the crown enamel. The sensitivity inside a birdcage cavity is approximately equal over the volume of a molar; only 30% of the molar's total dosimetric signal results from enamel. Some decrease in the intensity of the dosimetric signal from enamel is observed after irradiation. At room temperature, the signal is reduced by about 20% within 90 days and approaches a plateau with a time constant of about 35 days.  相似文献   

19.
Since 1987, the dosimetry service of the Netherlands Energy Research Foundation (ECN) has been certified by the Dutch government to perform personal dosimetry, using thermoluminescence dosemeters (TLDs). Performing neutron personal dosimetry requires a rather large investment in readers, TLDs and personnel to operate the service. About 800 persons are subjected to routine neutron monitoring in The Netherlands and their annual neutron doses are a relatively small fraction (less than 10%) of the annual Hp(10). In general, the measured neutron dose values are low (on average 93% of the users receive an annual neutron dose <0.2 mSv). The collective annual (neutron) dose has tended to decrease since 1992, but incidentally high doses have been observed. Leaving these incidents out, the average collective annual neutron doses for the different users of neutron sources are about the same.  相似文献   

20.
Powdered human tooth enamel was exposed to 60Co gamma rays up to a dose of 100 kGy. The electron paramagnetic resonance (EPR) signal intensity (1) of the radiation-generated carbon dioxide radicals was measured for dependence on absorbed dose (D). The EPR dose response can be fitted with an exponential saturation function I = I(M)[1 - exp(-D/D37)] with the saturated signal intensity (I(M)) and the dose saturation value (D37). The obtained value D37 = 9.64 (+/- 0.96) kGy (measured at least one month after irradiation) exceeds those given in the literature. The saturated concentration of orthorhombic CO2- radicals was estimated at 6.5 x 10(17) per gram of enamel by comparing the integrated EPR spectra of enamel and a standard MgO:Cr probe. For enamel samples, which were heated before irradiation for one hour at +405 degrees C, the value of D37T = 3.89 (+/- 0.44) kGy and the saturated value of CO2- radicals 3.4 x 10(17) per gram of enamel were lower than for unheated samples. The initial rise of the signal with the dose was slightly higher (8.8 x 10(13) radicals/g x Gy) for heated compared with unheated samples (6.8 x 10(13) radicals/g x Gy).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号