首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 13 毫秒
1.
Cai SS  Syage JA 《Analytical chemistry》2006,78(4):1191-1199
In this work, we compare the quantitative accuracy and sensitivity of analyzing lipids by atmospheric pressure photoionization (APPI), atmospheric pressure chemical ionization (APCI), and electrospray ionization (ESI) LC/MS. The target analytes include free fatty acids and their esters, monoglyceride, diglyceride, and triglyceride. The results demonstrate the benefits of using LC/APPI-MS for lipid analysis. Analyses were performed on a Waters ZQ LC/MS. Normal-phase solvent systems were used due to low solubility of these compounds in aqueous reversed-phase solvent systems. By comparison, APPI offers lower detection limits, generally highest signal intensities, and the highest S/N ratio. APPI is 2-4 times more sensitive than APCI and much more sensitive than ESI without mobile-phase modifiers. APPI and APCI offer comparable linear range (i.e., 4-5 decades). ESI sensitivity is dramatically enhanced by use of mobile phase modifiers (i.e., ammonium formate or sodium acetate); however, these ESI adduct signals are less stable and either are nonlinear or have dramatically reduced linear ranges. Analysis of fish oils by APPI shows significantly enhanced target analyte intensities in comparison with APCI and ESI.  相似文献   

2.
3.
A novel microchip heated nebulizer for atmospheric pressure chemical ionization mass spectrometry is presented. Anisotropic wet etching is used to fabricate the flow channels, inlet, and nozzle on a silicon wafer. An integrated heater of aluminum is sputtered on a glass wafer. The two wafers are jointed by anodic bonding, creating a two-dimensional version of an APCI source with a sample channel in the middle and gas channels symmetrically on both sides. The ionization is initiated with an external corona-discharge needle positioned 2 mm in front of the microchip heated nebulizer. The microchip APCI source provides flow rates down to 50 nL/min, stable long-term analysis with chip lifetime of weeks, good quantitative repeatability (RSD < 10%) and linearity (r(2) > 0.995) with linear dynamic rage of at least 4 orders of magnitude, and cost-efficient manufacturing. The limit of detection (LOD) for acridine measured with microchip APCI at flow rate of 6.2 muL/min was 5 nM, corresponding to a mass flow of 0.52 fmol/s. The LOD with commercial macro-APCI at a flow rate of 1 mL/min for acridine was the same, 5 nM, corresponding to a significantly worse mass flow sensitivity (83 fmol/s) than measured with microchip APCI. The advantages of microchip APCI makes it a very attractive new microfluidic detector.  相似文献   

4.
Food safety represents one of the main issues of national and international agencies appointed to health control. In April 2003, a French agency disclosed that powdered or smashed hot chili pepper imported from India and Pakistan was heavily contaminated with a carcinogenic azo dye known as Sudan I. This paper deals with a modern approach for assaying the content of this colorant in foodstuff down to a limit of a few tens of parts per billion. The isotope dilution method combined with APCI tandem mass spectrometry was used. The internal standard, 1-(d5-phenylazo)-2-naphthalenol, was obtained by simple chemistry, and its structure was determined by 1H NMR spectroscopy. The mass spectrometric method is more sensitive than the HPLC approach by a factor of 20.  相似文献   

5.
Oleuropein (OLP, 1), the active ingredient present (i) in food integrators extracted from olive leaves, (ii) in table olives, and (iii) in extra virgin olive oils is a nutraceutical whose health benefits have been widely documented. A new analytical method for its assay, which is based on the utilization of atmospheric pressure chemical ionization tandem mass spectrometry and on the use of a synthetic labeled analogue, the 4-trideuteriocarboxyoleuropein (2), as an internal standard, is presented. The results obtained with extra virgin olive oils from different cultivars and different Italian regions are discussed.  相似文献   

6.
Keratan sulfate (KS) is a glycosaminoglycan consisting of repeating disaccharide units composed of alternating residues of d-galactose and N-acetyl-d-glucosamine linked beta-(1-4) and beta-(1-3), respectively. In this study, electrospray ionization tandem mass spectrometry (ESI-MS/MS) was employed to identify keratan sulfate oligosaccharides. Two nonsulfated disaccharide isomers and two monosulfated disaccharide isomers were distinguished through MS/MS. In MS(1) spectra of multiply sulfated KS oligosaccharides, the charge state of the most abundant molecular ion equals the number of sulfates. Subsequent MS(2) and MS(3) spectra of mono-, di-, tri-, and tetrasulfated KS oligosaccharides and sialylated tetrasaccharides reveal diagnostic ions that can be used as fingerprint maps to identify unknown KS oligosaccharides. Based on the pattern of fragment ions, the compositions of an oligosaccharide mixture from shark cartilage KS and of two enzyme digests of bovine corneal KS were determined directly, without prior isolation of individual oligosaccharides by HPLC or other methods.  相似文献   

7.
Atmospheric pressure chemical ionization is employed for direct air analysis, without ion source modification, by using the sheath gas as the sample transport agent. A simple modification of the sheath gas inlet line allows introduction of gaseous samples into a commercial atmospheric pressure chemical ionization source. Optimization and testing of this novel air sampling method are described and detection of semivolatile compounds is shown. The analytical performance of the technique is established with methyl salicylate, including a limit of quantification of 100 pptr, a limit of detection of 50 pptr, a linear response from 100 pptr to 20 ppb, and rise and fall times of 12 and 20 s, respectively. Using reagent ion monitoring, it is shown that the protonated methanol dimer is the principal CI reagent ion leading to protonated dimethyl methylphosphonate, while the monomer is mainly responsible for protonating methyl salicylate. Since the formation of the CI reagent (methanol clusters) can be controlled by simple variation of experimental parameters, the selectivity of the method can be easily adjusted to suit the targeted analyte. Performance is found to be independent of the choice of air or nitrogen as the sheath gas (and thus as the sample matrix) and this, together with the sensitivity and speed of the technique, make it promising for field studies.  相似文献   

8.
A new strategy for amino acid analysis is reported involving derivatization with an N-hydroxysuccinimide ester of N-alkylnicotinic acid (Cn-NA-NHS) followed by reversed-phase chromatography and electrospray ionization mass spectrometry (RPC-MS). Detection sensitivity increased as the N-alkyl chain length of the nicotinic acid derivatizing agent was increased from 1 to 4. N-Acylation of amino acids with the Cn-NA-NHS reagents in water produced a stable product in roughly 1 min using a 4-fold molar excess of derivatizing agent in 0.1 M sodium borate buffer at pH values ranging from 8.5 to 10. Some O-acylation of tyrosine was also observed, but the product hydrolyzed within a few minutes at pH 10. The cystine product also degraded slowly over the course of a few days from reduction of the disulfide bond to form cysteine. The retention time of Cn-NA derivatized amino acids was lengthened in reversed-phase chromatography to the extent that polar amino acids were retained beyond the solvent peak, particularly in the cases of the C3-NA and C4-NA derivatives. Complete resolution of 18 amino acids was achieved in 28 min using the C4-NA-NHS reagent. Compared to N-acylation with benzoic acid, derivatization with C4-NA-NHS increased MS detection sensitivity 6-80-fold. This was attributed to the surfactant properties of the Cn-NA-NHS reagents. The quaternary amine increased the charge on amino acid conjugates while the presence of an adjacent alkyl chain further increased ionization efficiency by apparently enhancing amino acid migration to the surface of electrospray droplets. Further modification of the Cn-NA-NHS reagents with deuterium was used to prepare coded sets of derivatizing agents. These coding agents were used to differentially code samples and after mixing carry out comparative concentration measurements between samples using extracted ion chromatograms to estimate relative peak areas of derivatized amino acids.  相似文献   

9.
The atmospheric pressure chemical ionization of triacetone triperoxide (TATP) with subsequent separation and detection by ion mobility spectrometry has been studied. Positive ionization with hydronium reactant ions produced only fragments of the TATP molecule, with m/z 91 ion being the most predominant species. Ionization with ammonium reactant ions produced a molecular adduct at m/z 240. The reduced mobility value of this ion was constant at 1.36 cm(2)V(-1)s(-1) across the temperature range from 60 to 140 °C. The stability of this ion was temperature dependent and did not exist at temperatures above 140 °C, where only fragment ions were observed. The introduction of ammonia vapors with TATP resulted in the formation of m/z 58 ion. As the concentration of ammonia increased, this smaller ion appeared to dominate the spectra and the TATP-ammonium adduct decreased in intensity. The ion at m/z 58 has been noted by several research groups upon using ammonia reagents in chemical ionization, but the identity was unknown. Evidence presented here supports the formation of protonated 2-propanimine. A proposed mechanism involves the addition of ammonia to the TATP-ammonium adduct followed by an elimination reaction. A similar mechanism involving the chemical ionization of acetone with excess ammonia also showed the formation of m/z 58 ion. TATP vapors from a solid sample were detected with a hand-held ion mobility spectrometer operated at room temperature. The TATP-ammonium molecular adduct was observed in the presence of ammonia and TATP vapors with this spectrometer.  相似文献   

10.
Tang X  Bruce JE  Hill HH 《Analytical chemistry》2006,78(22):7751-7760
Reduced flow rate electrospray ionization has been proven to provide improved sensitivity, less background noise, and improved limits of detections for ESI-MS analysis. Miniaturizing the ESI source from conventional electrospray to microelectrospray and further down to nanoelectrospray has resulted in higher and higher sensitivity; however, when effects of flow rate were investigated for atmospheric pressure ESI-IMS using a nanospray emitter, a striking opposite result was observed. The general tendency we observed in ESI-IMS was that higher flow rate offered higher ion signal intensity throughout a variety of conditions investigated. Thus, further efforts were undertaken to rationalize these contradictory results. It is well accepted that decreased flow rate increases both ionization efficiency and transmission efficiency, thus improving ion signal in ESI-MS. However, our study revealed that decreased flow rate results in decreased ion signal because ion transfer is constant, no matter how flow rate changes in ESI-IMS. Since ion transfer is constant in atmospheric pressure ESI-IMS, ionization efficiency can be studied independently, which otherwise is not possible in ESI-MS in which both ionization efficiency and transmission efficiency vary as conditions alter. In this article, we present a systematic study of signal intensity and ionization efficiency at various experimental conditions using ESI-IMS and demonstrate the ionization efficiency as a function of flow rate, analyte concentration, and solvent composition.  相似文献   

11.
Chemical structures of polymer end groups play an important role in determining the functional properties of a polymeric system. We present a mass spectrometric method for determining end group structures. Polymeric ions are produced by electrospray ionization (ESI), and they are subject to source fragmentation in the ESI interface region to produce low-mass fragment ions. A series of source-fragment ions containing various numbers of monomer units are selected for high-energy collision-induced dissociation (CID) in a sector/time-of-flight tandem mass spectrometer. It is shown that high-energy CID spectra of source-induced fragment ions are very informative for end group structure characterization. By comparing the CID spectra of fragment ions with those of known chemicals, it is possible to unambiguously identify the end group structures. The utility of this technique is illustrated for the analysis of two poly(ethylene glycol)-based slow-releasing drugs where detailed structural characterization is of significance for drug formulation, quality control, and regulatory approval. Practical issues related to the application of this method are discussed.  相似文献   

12.
Saad OM  Leary JA 《Analytical chemistry》2003,75(13):2985-2995
A new method using a combination of electrospray ionization mass spectrometry (ESI-MS) and tandem mass spectrometry (MSn) was developed for the identification and quantitative analysis of eight heparan sulfate (HS)- and heparin-derived delta-disaccharides obtained by enzymatic depolymerization. The compositional analysis of nonisomeric disaccharide constituents of heparin/HS was achieved from full-scan MS1 spectra using an internal standard and a calculated response factor for each disaccharide. Diagnostic product ions from MSn spectra of isomeric disaccharides were used for the quantitative analysis of the relative amounts of each of the isomers in mixtures. The protocol was validated using several quality control samples and showed satisfactory accuracy and precision. The analysis is rapid, accurate, and uses no purification or separation steps prior to analysis by MS, thus reducing sample consumption and analysis time of traditional methods. Using this quantitative analysis procedure, percentages of disaccharide compositions for heparins from porcine and bovine intestinal mucosa and heparan sulfate from bovine kidney were determined.  相似文献   

13.
Although qualitative and/or semiquantitative real-time monitoring of chemical reactions have been reported with a few mass spectrometric approaches, to our knowledge, no quantitative mass spectrometric approach has been reported so far to have a calibration valid up to molar concentrations as required by process control. This is mostly due to the absence of a practical solution that could well address the sample overloading issue. In this study, a novel autosampling flow injection analysis coupled with an atmospheric pressure chemical ionization mass spectrometry (FIA/APCI-MS) system, consisting of a 1 μL automatic internal sample injector, a postinjection splitter with 1:10 splitting ratio, and a detached APCI source connected to the mass spectrometer using a 4.5 in. long, 0.042 in. inner diameter (ID) stainless-steel capillary, was thus introduced. Using this system together with an optional FIA solvent modifier, e.g., 0.05% (v/v) isopropylamine, a linear quantitative calibration up to molar concentration has been achieved with 3.4-7.2% relative standard deviations (RSDs) for 4 replicates. As a result, quantitative real-time monitoring of a model reaction was successfully performed at the 1.63 M level. It is expected that this novel autosampling FIA/APCI-MS system can be used in quantitative real-time monitoring of a wide range of reactions under diverse reaction conditions.  相似文献   

14.
The coupling of a rotation planar preparative thin-layer chromatography system on-line with mass spectrometry is demonstrated using a simple plumbing scheme and a self-aspirating heated nebulizer probe of a corona discharge atmospheric pressure chemical ionization source. The self-aspiration of the heated nebulizer delivers approximately 20 microL/min of the 3.0 mL/min eluate stream to the mass spectrometer, eliminating the need for an external pump in the system. The viability of the coupling is demonstrated with a three-dye mixture composed of fat red 7B, solvent green 3, and solvent blue 35 separated and eluted from a silica gel-coated rotor using toluene. The real-time characterization of the dyes eluting from the rotor is illustrated in positive ion full-scan mode. Other self-aspirating ion source systems including atmospheric pressure photoionization, electrospray ionization, and inductively coupled plasma ionization, for example, might be configured and used in a similar manner coupled to the chromatograph to expand the types of analytes that could be ionized, detected, and characterized effectively.  相似文献   

15.
Nemes P  Vertes A 《Analytical chemistry》2007,79(21):8098-8106
Mass spectrometric analysis of biomolecules under ambient conditions promises to enable the in vivo investigation of diverse biochemical changes in organisms with high specificity. Here we report on a novel combination of infrared laser ablation with electrospray ionization (LAESI) as an ambient ion source for mass spectrometry. As a result of the interactions between the ablation plume and the spray, LAESI accomplishes electrospray-like ionization. Without any sample preparation or pretreatment, this technique was capable of detecting a variety of molecular classes and size ranges (up to 66 kDa) with a detection limit of 8 and 25 fmol for verapamil and reserpine, respectively, and quantitation capabilities with a four-decade dynamic range. We demonstrated the utility of LAESI in a broad variety of applications ranging from plant biology to clinical analysis. Proteins, lipids, and metabolites were identified, and antihistamine excretion was followed via the direct analysis of bodily fluids (urine, blood, and serum). We also performed in vivo spatial profiling (on leaf, stem, and root) of metabolites in a French marigold (Tagetes patula) seedling.  相似文献   

16.
A rapid and sensitive high-performance liquid chromatographic mass spectrometric (HPLC-MS) method is described for the determination and quantification of 12 dietary flavonoid glycosides and aglycons in human urine samples. Chromatographic separation of the analytes of interest was achieved by column-switching, using the first column (a Zorbax 300SB C-3 column) for sample cleanup and eluting the heart-cut flavonoid fraction onto the second column (a Zorbax SB C-18 column) for separation and detection by ultraviolet and atmospheric pressure chemical ionization MS using single ion monitoring in negative mode. The fragmentor voltage was optimized with regard to maximum abundance of the molecular ion and qualifier ions of the analytes. Calibration graphs were prepared for urine, and good linearity was achieved over a dynamic range of 2.5-1000 ng/mL. The inter- and intraassay coefficients of variation for the analysis of the 12 different flavonoids in quality control urine samples were 12.3% on average (range 11.0-13.7%, n = 24, reproducibility) and the repeatability of the assay were 5.0% (mean, range 0.1-14.8%, n = 12). A subset of 10 urine samples from a human dietary intervention study with high and low flavonoid content was analyzed, and the results are reported.  相似文献   

17.
Real time analysis of human breath is achieved in an atmospheric pressure ionization mass spectrometer (API-MS) by negatively charging exhaled vapors via contact with an electrospray cloud. The spectrum observed is dominated by a wide range of deprotonated fatty acids, including saturated chains up to C14. Above C14, the background from cutaneous sources becomes dominant. We also tentatively identify a series of unsaturated fatty acids (C7-C10), ketomonocarboxylic acids (C6-C10), and a family of aldehydes. The ionization probability of large fatty acids increases drastically when the humidity changes from 20% to 95%. Accordingly, distinguishing lung vapors (humid) from those in the background (dry) requires special precautions. Estimated fatty acid vapor concentrations in breath based on our measurements ( approximately 100 ppt) are in fair agreement with values expected from blood concentrations in the range for which data are available (C3-C6).  相似文献   

18.
The use of photoionization at atmospheric pressure shows great potential for the mass analysis of large apolar or hydrophobic peptides. Mass spectra that were obtained using this technique showed mainly singly charged ions. While polar peptides spectra do not produce fragment ions, others lead to B-type or C-type in-source fragmentation. These dissociation reactions, which could involve electron capture dissociation processes in the case of the C-type ions, are observed for hydrophobic peptides. Both the compatibility of this ionization mode with reversed- or normal-phase liquid chromatographic separation and its sensitivity allow liquid chromatography coupling to both mass spectrometry and tandem mass spectrometry for the analyses of hydrophobic peptide mixtures. Atmospheric pressure photoionization seems to be an interesting alternative method to study hydrophobic peptides that are not easily ionizable by more classical ionization techniques such as electrospray ionization and matrix-assisted laser desorption/ionization.  相似文献   

19.
A method for the determination of underivatized amino acids based on capillary electrophoresis coupled to electrospray ionization mass spectrometry (CE-ESI-MS) is described. To analyze free amino acids simultaneously a low acidic pH condition was used to confer positive charge on whole amino acids. The choice of the electrolyte and its concentration influenced resolution and peak shape of the amino acids, and 1 M formic acid was selected as the optimal electrolyte. Meanwhile, the sheath liquid composition had a significant effect on sensitivity and the highest sensitivity was obtained when 5 mM ammonium acetate in 50% (v/v) methanol-water was used. Protonated amino acids were roughly separated by CE and selectively detected by a quadrupole mass spectrometer with a sheath flow electrospray ionization interface. Under the optimized conditions, 19 free amino acids normally found in proteins and several physiological amino acids were well determined in less than 17 min. The detection limits for basic amino acids were between 0.3 and 1.1 mumol/L and for acidic and low molecular weight amino acids were less than 6.0 mumol/L with pressure injection of 50 mbar for 3 s (3 nL) at a signal-to-noise ratio of 3. This method is simple, rapid, and selective compared with conventional techniques and could be readily applied to the analysis of free amino acids in soy sauce.  相似文献   

20.
Molecular weight distributions of fulvic acid from the Suwannee River, Georgia, were investigated by electrospray ionization/quadrupole mass spectrometry (ESI/ QMS), and fragmentation pathways of specific fulvic acid masses were investigated by electrospray ionization/ion trap multistage tandem mass spectrometry (ESI/MST/ MS). ESI/QMS studies of the free acid form of low molecular weight poly(carboxylic acid) standards in 75% methanol/25% water mobile phase found that negative ion detection gave the optimum generation of parent ions that can be used for molecular weight determinations. However, experiments with poly(acrylic acid) mixtures and specific high molecular weight standards found multiply charged negative ions that gave a low bias to molecular mass distributions. The number of negative charges on a molecule is dependent on the distance between charges. ESI/MST/MS of model compounds found characteristic water loss from alcohol dehydration and anhydride formation, as well as CO2 loss from decarboxylation, and CO loss from ester structures. Application of these fragmentation pathways to specific masses of fulvic acid isolated and fragmented by ESI/MST/MS is indicative of specific structures that can serve as a basis for future structural confirmation after these hypothesized structures are synthesized.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号