首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 35 毫秒
1.
For the first time, a traditional radioactive nickel (63Ni) beta emission ionization source for ion mobility spectrometry was employed with an atmospheric pressure ion mobility orthogonal reflector time-of-flight mass spectrometer (IM(tof)MS) to detect a chemical warfare agent (CWA) simulant from aerosol samples. Aerosol-phase sampling employed a quartz cyclonic chamber for sample introduction. The simulant reference material, which closely mimicked the characteristic chemical structure of CWAs as defined and described by Schedule 1, 2, or 3 of the Chemical Warfare Convention treaty verification, was used in this study. An overall elevation in arbitrary signal intensity of approximately 1.0 orders of magnitude was obtained by the progressive increase of the thermal AP-IMS temperature from 75 to 275 degrees C. A mixture of one G-type nerve simulant (dimethyl methylphosphonate (DMMP)) in four (water, kerosene, gasoline, diesel) matrixes was found in each case (AP-IMS temperature 75-275 degrees C) to be clearly resolved in less than 2.20 x 10(4) micros using the IM(tof)MS instrument. Corresponding ions, masses, drift times, K(o) values, and arbitrary signal intensities for each of the sample matrixes are reported for the CWA simulant DMMP.  相似文献   

2.
A secondary electrospray ionization (SESI) method was developed as a nonradioactive ionization source for ion mobility spectrometry (IMS). This SESI method relied on the gas-phase interaction between charged particles created by electrospray ionization (ESI) and neutral gaseous sample molecules. Mass spectrometry (MS) was used as the detection method after ion mobility separation for ion identification. Preliminary investigations focussed on understanding the ionization process of SESI. The performance of ESI-IMS and SESI-IMS for illicit drug detection was evaluated by determining the analytical figures of merit. In general, SESI had a higher ionization efficiency for small volatile molecules compared with the electrospray method. The potential of developing a universal interface for both GC- and LC-MS with an addition stage of mobility separation was demonstrated.  相似文献   

3.
Development of environmentally acceptable decontaminants of chemical weapons and other highly toxic chemicals is important because of security, economical, health, political, and environmental reasons. The efficiency of natural zeolite (clinoptilolite) and synthetic zeolite, metal oxides, and their mixtures as chemical and physical sorbents of chemical warfare agents (CWA) was investigated. Commonly studied chemical warfare agent simulants dimethyl methylphosphonate (DMMP) and 2-chloroethyl ethyl sulfide (2-CEES) were included in this study. Organic solutions of DMMP and 2-CEES were passed through a column filled with natural and synthetic zeolites and their mixtures with metal oxides. After passing through the column filled with different sorbents, all eluents were filtered and centrifuged before the gas chromatography–mass spectroscopy (GC–MS) analysis. The efficiency of investigated adsorbents was estimated based on the obtained data. All investigated sorbents exhibited absorption efficiency for both simulants of chemical warfare agents. Infrared spectroscopy was used for the detection of DMMP and 2-CEES adsorbed to the investigated adsorbents. Since GC–MS analysis results indicate very good sorption properties of both simulants, the detection of adsorbed CWA simulants was a matter of routine.  相似文献   

4.
Nayak R  Liu J  Sen AK  Knapp DR 《Analytical chemistry》2008,80(22):8840-8844
A gold coated nanoporous alumina surface was used for dual ionization mode mass spectrometric analysis using desorption electrospray ionization (DESI) and laser desorption ionization (LDI). DESI and LDI mass spectrometry (MS) from the nanoporous alumina surface were compared with conventional electrospray ionization (ESI) mass spectrometry and matrix assisted laser desorption ionization (MALDI) for analysis of tryptic digests of proteins. Combined use of DESI and LDI offer greater peptide coverage than either method alone and comparable peptide coverage as with dual MALDI and ESI. This dual ionization technique using a common platform with same sample spot demonstrates a potential time and cost-effective tool for improved shotgun proteomic analysis.  相似文献   

5.
Here we describe a mass spectrometry (MS) approach for biomarker discovery and structural characterization, based on both top-down and bottom-up analyses. Capillary electrophoresis (CE) coupled to electrospray ionization (ESI) time-of-flight (TOF) MS serves to separate and mass-measure the thousands of polypeptides contained in human urine. Statistical analysis of the differences between healthy control samples and patients with focal-segmental glomerulosclerosis, membranous glomerulonephritis, minimal change disease, IgA nephropathy, and diabetic nephropathy validates multiple biomarkers for the control and each of the diseases. To identify those biomarkers, we employ preparative CE, enabling direct infusion ESI MS analysis, followed by sample manipulation and reanalysis where necessary. We show how tandem Fourier transform ion cyclotron resonance (FT-ICR) MS identifies these sometimes large (>8 kDa) biomarkers. Critically, we maintain connectivity between the CE TOF MS data and the ICR data used for biomarker identification.  相似文献   

6.
Amphetamine, methamphetamine, and their methylenedioxy derivatives have been identified and measured in a human urine matrix using solid-phase microextraction (SPME) and high-field asymmetric waveform ion mobility spectrometry (FAIMS) in combination with electrospray ionization (ESI) and mass spectrometric detection (MS). Limits of detection in human urine between 200 pg/mL and 7.5 ng/mL have been achieved. The use of a simple extraction method, SPME, combined with the high sensitivity and selectivity of ESI-FAIMS-MS eliminates the need for chromatographic separation and allows for very rapid sample processing.  相似文献   

7.
Chemical ionization reaction time-of-flight mass spectrometry (CIR-TOF-MS) has been used for the analysis of prepared mixtures of chemical weapon agents (CWAs) sarin and sulfur mustard. Detection of the CWA simulants 2-chloroethyl ethyl sulfide, triethyl phosphate, and dimethyl methyl phosphonate has also been investigated. Chemical ionization of all the agents and simulants was shown to be possible using the CIR-TOF-MS technique with a variety of reagent ions, and the sensitivity was optimized by variation of instrument parameters. The ionization process was found to be largely unaffected by sample humidity levels, demonstrating the potential suitability of the method to a range of environmental conditions, including the analysis of CWAs in air and in the breath of exposed individuals.  相似文献   

8.
A method has been developed for the trace analysis of 27 compounds from a diverse group of pharmaceuticals, steroids, pesticides, and personal care products. The method employs solid-phase extraction (SPE) and liquid chromatography/tandem mass spectrometry (LC/MS/MS), using electrospray ionization (ESI) in both positive and negative modes and atmospheric pressure chemical ionization in positive mode. Unlike many previous methods, a single SPE procedure using 1 L of water coupled to a simple LC method is used for all ionization modes. Instrument detection limits for most compounds were below 1.0 pg on column with reporting limits of 1.0 ng/L in water. Recoveries for most compounds in deionized water were greater than 80%. Sulfuric acid was found to be the preferred sample preservative, and structures of all MS/MS product ions are proposed. Matrix effects from waters with a high content of treated municipal effluent were observed in both ESI modes and are discussed in the paper.  相似文献   

9.
Hu B  So PK  Chen H  Yao ZP 《Analytical chemistry》2011,83(21):8201-8207
Electrospray ionization (ESI) is a mass spectrometric technique widely used in various fields including chemistry, biology, medicine, pharmaceutical industry, clinical assessment, and forensic science. In this study, we report a simple and economical ESI-mass spectrometry (MS) technique, which makes use of disposable wooden tips (wooden toothpicks) for loading and ionization of samples. Samples could be loaded by normal pipetting onto the tip or simply dipping the tip into sample solutions. The hydrophilic and porous nature of wood allows effective adhesion of the sample solution for durable ion signals. The tip can be directly connected to nano-ESI ion sources of various mass spectrometers. Upon application of high voltage to the tip, desirable mass spectra could be obtained. We demostrated that this new technique is applicable for analysis of various samples, including organic compounds, organometallic compounds, peptides, proteins, and samples that cannot be directly analyzed by conventional ESI techniques, e.g., slurry samples and powder samples. The slim and hard properties of the wooden tip enable sampling from specific locations such as corners and small openings, indicating potential applications of the new technique in forensic investigations. The observation of electrospray ionization from wooden materials also allows us to get new insights into the materials that can be directly ionized for mass spectrometric analysis.  相似文献   

10.
Traveling wave ion mobility mass spectrometry (TWIM MS) was combined with gradient tandem mass spectrometry (gMS(2)) to deconvolute and characterize superimposed ions with different charges and shapes formed by electrospray ionization (ESI) of self-assembled, hexameric metallomacrocycles composed of terpyridine-based ligands and Cd(II) ions. ESI conditions were optimized to obtain intact hexameric cation assemblies in a low charge state (2+), in order to minimize overlapping fragments of the same mass-to-charge ratio. With TWIM MS, intact hexameric ions could be separated from remaining fragments and aggregates. Collisional activation of these hexameric ions at varying collision energies (gMS(2)), followed by TWIM separation, was then performed to resolve macrocyclic from linear hexameric species. Because of the different stabilities of these architectures, gMS(2) changes their relative amounts, which can be monitored individually after subsequent ion mobility separation. On the basis of this unique strategy, hexameric cyclic and linear isomers have been successfully resolved and identified. Complementary structural information was gained by the gMS(2) fragmentation pattern of the metallosupramolecules, acquired by collisionally activated dissociation after TWIM dispersion. TWIM MS interfaced with gMS(2) should be particularly valuable for the characterization of a variety of supramolecular polymers, which often contain isomeric architectures that yield overlapping fragments and aggregates upon ESI MS analysis.  相似文献   

11.
The combination of electrochemistry (EC) and mass spectrometry (MS) is a powerful analytical tool for studying mechanisms of redox reactions, identification of products and intermediates, and online derivatization/recognition of analytes. This work reports a new coupling interface for EC/MS by employing nanospray desorption electrospray ionization, a recently developed ambient ionization method. We demonstrate online coupling of nanospray desorption electrospray ionization MS with a traditional electrochemical flow cell, in which the electrolyzed solution emanating from the cell is ionized by nanospray desorption electrospray ionization for MS analysis. Furthermore, we show first coupling of nanospray desorption electrospray ionization MS with an interdigitated array (IDA) electrode enabling chemical analysis of electrolyzed samples directly from electrode surfaces. Because of its inherent sensitivity, nanospray desorption electrospray ionization enables chemical analysis of small volumes and concentrations of sample solution. Specifically, good-quality signal of dopamine and its oxidized form, dopamine o-quinone, was obtained using 10 μL of 1 μM solution of dopamine on the IDA. Oxidation of dopamine, reduction of benzodiazepines, and electrochemical derivatization of thiol groups were used to demonstrate the performance of the technique. Our results show the potential of nanospray desorption electrospray ionization as a novel interface for electrochemical mass spectrometry research.  相似文献   

12.
Molecular weight distributions of fulvic acid from the Suwannee River, Georgia, were investigated by electrospray ionization/quadrupole mass spectrometry (ESI/ QMS), and fragmentation pathways of specific fulvic acid masses were investigated by electrospray ionization/ion trap multistage tandem mass spectrometry (ESI/MST/ MS). ESI/QMS studies of the free acid form of low molecular weight poly(carboxylic acid) standards in 75% methanol/25% water mobile phase found that negative ion detection gave the optimum generation of parent ions that can be used for molecular weight determinations. However, experiments with poly(acrylic acid) mixtures and specific high molecular weight standards found multiply charged negative ions that gave a low bias to molecular mass distributions. The number of negative charges on a molecule is dependent on the distance between charges. ESI/MST/MS of model compounds found characteristic water loss from alcohol dehydration and anhydride formation, as well as CO2 loss from decarboxylation, and CO loss from ester structures. Application of these fragmentation pathways to specific masses of fulvic acid isolated and fragmented by ESI/MST/MS is indicative of specific structures that can serve as a basis for future structural confirmation after these hypothesized structures are synthesized.  相似文献   

13.
Electrospray-assisted laser desorption/ionization (ELDI), an ionization method that combines laser desorption and electrospray ionization (ESI), can be used under ambient conditions to characterize organic compounds (including FD&C dyes, amines, extracts of a drug tablet) separated in the central track on a thin-layer chromatography (TLC) plate coated with either reversed-phase C18 particles or normal-phase silica gel. After drying, the TLC plate was placed on an acrylic sample holder set in front of the sampling skimmer of an ion trap mass analyzer. The chemicals at the center of the TLC plate were analyzed by pushing the sample holder into the path of a laser beam with a syringe pump. The molecules in the sample spot were desorbed by continuously irradiating the surface of the TLC plate with a pulsed nitrogen laser. Then, the desorbed sample molecules entered an ESI plume where they were ionized through the reactions with the charged species (including protons, hydronium ions and their cluster ions, solvent ions, and charged droplets) generated by electrospraying a methanol/water solution. MS/MS analyses were also performed to further characterize the analytes. The detection limit of TLC/ELDI/MS is approximately 10(-6) M. This was evaluated by using FD&C red dye as the standard. A linear relationship was found for the calibration curve with the concentration of FD&C red dye ranged from 10(-3) to 10(-6) M.  相似文献   

14.
Enhanced charging, or supercharging, of analytes in electrospray ionization mass spectrometry (ESI MS) facilitates high resolution MS by reducing an ion mass-to-charge (m/z) ratio, increasing tandem mass spectrometry (MS/MS) efficiency. ESI MS supercharging is usually achieved by adding a supercharging reagent to the electrospray solution. Addition of these supercharging reagents to the mobile phase in liquid chromatography (LC)-MS/MS increases the average charge of enzymatically derived peptides and improves peptide and protein identification in large-scale bottom-up proteomics applications but disrupts chromatographic separation. Here, we demonstrate the average charge state of selected peptides and proteins increases by introducing the supercharging reagents directly into the ESI Taylor cone (in-spray supercharging) using a dual-sprayer ESI microchip. The results are comparable to those obtained by the addition of supercharging reagents directly into the analyte solution or LC mobile phase. Therefore, supercharging reaction can be accomplished on a time-scale of ion liberation from a droplet in the ESI ion source.  相似文献   

15.
An evaluation of over 75 pesticides by high-performance liquid chromatography/mass spectrometry (HPLC/MS) clearly shows that different classes of pesticides are more sensitive using either atmospheric pressure chemical ionization (APCI) or electrospray ionization (ESI). For example, neutral and basic pesticides (phenylureas, triazines) are more sensitive using APCI (especially positive ion). While cationic and anionic herbicides (bipyridylium ions, sulfonic acids) are more sensitive using ESI (especially negative ion). These data are expressed graphically in a figure called an ionization-continuum diagram, which shows that protonation in the gas phase (proton affinity) and polarity in solution, expressed as proton addition or subtraction (pKa), is useful in selecting APCI or ESI. Furthermore, sodium adduct formation commonly occurs using positive ion ESI but not using positive ion APCI, which reflects the different mechanisms of ionization and strengthens the usefulness of the ionization-continuum diagram. The data also show that the concept of "wrong-way around" ESI (the sensitivity of acidic pesticides in an acidic mobile phase) is a useful modification of simple PKa theory for mobile-phase selection. Finally, this finding is used to enhance the chromatographic separation of oxanilic and sulfonic acid herbicides while maintaining good sensitivity in LC/MS using ESI negative.  相似文献   

16.
Fast and accurate analytical methods are essential to keep pace with sample libraries produced from combinational chemistry and high-throughput biological screening. Many laboratories now use a combination of ionization techniques for the characterization of these samples, including atmospheric pressure chemical ionization (APCI), electrospray ionization (ESI), and photoionization (PI). Data are shown here from the analysis of a compound collection plate containing a variety of sample structures. ESI will normally analyze around 80% of these samples, necessitating a source change to analyze a further 10%. In this work, we have developed a new combined ESI-APCI source (ESCi) for use in on-line HPLC applications. The combined source allows alternate on-line ESI and APCI scans with polarity switching within a single analysis. The ESCi source has been designed to be a simple replacement for the existing mass spectrometer interfaces. Each ionization method is optimized independently using separate tuning parameters. Instrument electronics can readily switch between the two ionization methods and polarities within normal interscan time periods. The new source has reduced the analysis time of sample plates by eliminating the need for a source hardware change, source optimization, and repeat analyses.  相似文献   

17.
The utility of ion mobility spectrometry (IMS) for separation of mixtures and structural characterization of ions has been demonstrated extensively, including in biological and nanoscience contexts. A major attraction of IMS is its speed, several orders of magnitude greater than that of condensed-phase separations. Nonetheless, IMS combined with mass spectrometry (MS) has remained a niche technique, substantially because of limited sensitivity resulting from ion losses at the IMS-MS junction. We have developed a new electrospray ionization (ESI)-IMS-QTOF MS instrument that incorporates electrodynamic ion funnels at both front ESI-IMS and rear IMS-QTOF interfaces. The front funnel is of the novel "hourglass" design that efficiently accumulates ions and pulses them into the IMS drift tube. Even for drift tubes of 2-m length, ion transmission through IMS and on to QTOF is essentially lossless across the range of ion masses relevant to most applications. The rf ion focusing at the IMS terminus does not degrade IMS resolving power, which exceeds 100 (for singly charged ions) and is close to the theoretical limit. The overall sensitivity of the present ESI-IMS-MS system is comparable to that of commercial ESI-MS, which should make IMS-MS suitable for analyses of complex mixtures with ultrahigh sensitivity and exceptional throughput.  相似文献   

18.
Attenuated total reflectance Fourier transform infrared (ATR-FT-IR) spectroscopy is used to identify liquid and solid-phase chemicals. This research examines the feasibility of identifying vapor-phase chemicals using a field-portable ATR-FT-IR spectrometer (TravelIR) combined with solid-phase microextraction (SPME). Two nerve agent simulants, diisopropyl methylphosphonate (DIMP) and di-methyl methylphosphonate (DMMP), and three sorbent polymers were evaluated. Each polymer was deposited as a thin film on the instrument's sampling interface to partition and concentrate the simulants from air samples prepared in Tedlar bags. The lowest vapor concentrations identified were 50 ppb (v/v) (DIMP) and 250 ppb (v/v) (DMMP). The ATR-FT-IR instrument demonstrated a linear response at concentrations of 1 ppm (v/v) and below. Increasing the sample exposure time, the sample air velocity, and the film thickness was demonstrated to increase the amount of analyte extracted from the air sample. This research demonstrates that it is feasible to use a portable ATR-FT-IR spectrometer with SPME sampling to detect and identify vapor-phase chemicals.  相似文献   

19.
Oligosaccharides released from several glycoproteins were derivatized with either 4-aminobenzoic acid 2-(diethylamino)ethyl ester (ABDEAE) (Yoshino, K.; et al. Anal. Chem. 1995, 67, 4028-4031) or 2-aminopyridine. The resulting derivatives were analyzed on a nanoflow electrospray ionization (ESI) quadrupole-inlet time-of-flight mass spectrometer using the low-energy collision-induced dissociation technique. In the MS/MS spectra, the oxonium (b or internal series) and y series ions, which are derived from the multiply charged precursor ions, were predominant and were used for the structural readout. Some oxonium ions that were observed in the low-mass region, but that were not found in the PSD analyses (Mo, W.; et al. Anal. Chem. 1998, 70, 4520-4526), rendered a more detailed structural insight. The oxonium ions at m/z 512.2, which are derived from the fucosylated oligosaccharides of immunoglobulin Y and thyroglobulin, were observed, suggesting that fucosylation had occurred proximal to the outer nonreducing terminus. In addition, the data herein show that structural elucidation can be routinely achieved at a low sample concentration. For the case of ABDEAE derivatives, this can be achieved at the 50 fmol/microL level and with the actual sample consumption at the attomole level using nanoflow ESI MS/MS.  相似文献   

20.
The ability of electrospray ionization mass spectrometry (ESI MS) to analyze heavy aromatic petroleum fractions using silver nitrate as a reagent compound to form characteristic adduct ions has been examined. The complexation of aromatic compounds containing long alkyl substituents with the silver ion leads to the formation of abundant adduct ions such as [M + Ag]+ and [2M + Ag]+. The concentration of the [2M + Ag]+ ions can be reduced by increasing the sampling cone voltage. Molecular ions and other adduct ions may also be formed depending on the structure of the aromatic molecule. Results obtained from the analysis of representative heavy petroleum fractions and vacuum residues by the Ag+ ESI MS method and conventional ionization methods were in good agreement. The current method extends the applicability of electrospray ionization to the analysis of neutral hydrocarbons in heavy aromatic petroleum fractions. It is simple and compatible with widely available LC/MS instrumentation. The extreme complexity of the Ag  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏