首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Mao Y  Chang S  Sherif S  Flueraru C 《Applied optics》2007,46(23):5887-5894
The quality and parameters of probing optical beams are extremely important in biomedical imaging systems both for image quality and light coupling efficiency considerations. For example, the shape, size, focal position, and focal range of such beams could have a great impact on the lateral resolution, penetration depth, and signal-to-noise ratio of the image in optical coherence tomography. We present a beam profile characterization of different variations of graded-index (GRIN) fiber lenses, which were recently proposed for biomedical imaging probes. Those GRIN lens modules are made of a single mode fiber and a GRIN fiber lens with or without a fiber spacer between them. We discuss theoretical analysis methods, fabrication techniques, and measured performance compared with theory.  相似文献   

2.
The recent development and availability of fiber-optic components including graded-index (GRIN) microlenses and the unique optical properties of single-mode optical fibers make it possible to build ideal detector systems for light-scattering measurements. We show that the simple coupling of a 0.25-pitch GRIN lens and a single-mode optical fiber to form a collimator makes a nonimaging detector system with properties that are superior to conventional setups based on pinholes and that approaches the theoretical limit of a perfectly coherent detector.  相似文献   

3.
Ryu SY  Choi HY  Na J  Choi WJ  Lee BH 《Applied optics》2008,47(10):1510-1516
We demonstrate a compact all-fiber sampling probe for an optical coherence tomography (OCT) system. By forming a focusing lens directly on the tip of an optical fiber, a compact sampling probe could be implemented. To simultaneously achieve a sufficiently long working distance and a good lateral resolution, we employed a large-mode area photonic crystal fiber (PCF) and a coreless silica fiber (CSF) of the same diameters. A working distance of up to 1270 microm, a 3 dB distance range of 2210 microm, and a transverse resolution of 14.2 microm were achieved with the implemented PCF lensed fiber; these values are comparable to those obtainable with a conventional objective lens having an NA of 0.25 (10 x). The performance of the OCT system equipped with the proposed PCF lensed fiber is presented by showing the OCT images of a rat finger as a biological sample and a pearl as an in-depth sample.  相似文献   

4.
PURPOSE: To reconstruct the gradient index (GRIN) profile of human crystalline lenses ex-vivo using Optical Coherence Tomography (OCT) imaging with an optimization technique and to study the dependence of the GRIN profile with age. METHODS: Cross-sectional images of nine isolated human crystalline lenses with ages ranging from 6 to 72 (post mortem time 1 to 4 days) were obtained using a custom-made OCT system. Lenses were extracted from whole cadaver globes and placed in a measurement chamber filled with preservation medium (DMEM). Lenses were imaged with the anterior surface up and then flipped over and imaged again, to obtain posterior lens surface profiles both undistorted and distorted by the refraction through the anterior crystalline lens and GRIN. The GRIN distribution of the lens was described with three variables by means of power function, with variables being the nucleus and surface index, and a power coefficient that describes the decay of the refractive index from the nucleus to the surface. An optimization method was used to search for the parameters that produced the best match of the distorted posterior surface. RESULTS: The distorted surface was simulated with accuracy around the resolution of the OCT system (under 15 μm). The reconstructed refractive index values ranged from 1.356 to 1.388 for the surface, and from 1.396 to 1.434 for the nucleus. The power coefficient ranged between 3 and 18. The power coefficient increased significantly with age, at a rate of 0.24 per year. CONCLUSION: Optical Coherence Tomography allowed optical, non-invasive measurement of the 2-D gradient index profile of the isolated human crystalline lens ex vivo. The age-dependent variation of the changes is consistent with previous data using magnetic resonance imaging, and the progressive formation of a refractive index plateau.  相似文献   

5.
A fiber-optical probe for pH sensing and real-time imaging is successfully fabricated by connecting a polymer imaging fiber and a gradient index (GRIN) lens rod which was modified with a sensing film. By employing an improved metallographic microscope, an optical system is designed to cooperate with the probe. This novel technique has high-quality imaging capabilities for observing remote samples while measuring pH. The linear range of the probe is pH 1.2-3.5. This technique overcomes the difficulty that high-quality images cannot be obtained when directly using conventional imaging bundles for pH sensing and imaging. As preliminary applications, the corrosion behavior of an iron screw and the reaction process of rust were investigated in buffer solutions of pH 2.0 and 2.9, respectively. The experiment demonstrated that the pH values of the analytes' surface were higher than that of buffer solutions due to the chemical reaction. It provides great potential for applications in optical multifunctional detection, especially in chemical sensing and biosensing.  相似文献   

6.
Su W  Gilbert JA 《Applied optics》1996,35(24):4772-4781
Gradient-index (GRIN) lenses have been widely used as collimators in various fiber-optic sensors and as optical coupling devices in components designed for optical communication systems. However, relatively little attention has been paid to the birefringent properties of GRIN lenses and the potential for using them as photoelastic sensing elements in optical transducers. Analytical and experimental results are described that were obtained for the intensity distribution produced by studying a GRIN lens by using a polariscope. The residual birefringence inherent in an unloaded lens is initially studied. The lens is then assumed to be diametrically loaded and the superposition is studied by the method of ray tracing. When the results obtained from the simulation for a Selfoc, 0.25-pitch lens are compared with experimental data, an excellent agreement is obtained. Intensity increases monotonically with load, confirming that the lens would be a good choice for the sensing element of an optical transducer designed as part of a strain or acceleration measurement system. The numerical simulation is then used to study the influence of residual stress on sensitivity.  相似文献   

7.
8.
角膜和晶状体是人眼光学系统中两个关键的屈光元件,为了理解眼内各介质和整个眼球的屈光状态以及视网膜上的成像,有利于眼科临床方面的应用,需要分别对二者进行光学特性模型的分析与研究。根据角膜和晶状体的光学特性,应用光学设计软件Zemax和有关的数学工具,从光学成像角度,分别对角膜和晶状体模型进行研究:基于结合人眼光学模型的角膜双二次曲面模型的建立方法,统计分析了我国人眼实测角膜参数的数据;通过对晶状体折射率分布特点的分析,分别在轴向和径向上进行了综合分析。最后给出了符合我国人眼特点的角膜面型的统计数值,完善了我国人眼角膜光学模型的建立;获得了形式简单且能够表示晶状体折射率分布一般特征的梯度渐变模型表达式。基于收集的我国人眼实测数据的角膜面型模型和晶状体梯度渐变形式的折射率模型,为解决人眼光学系统研究中的关键问题提供了新的方案和思路。  相似文献   

9.
Fang X  Tan W 《Analytical chemistry》1999,71(15):3101-3105
We have developed a new fluorescent method for single-molecule detection (SMD) and imaging using an optical fiber probe. The fluorophores were excited by the evanescent wave field produced on the core surface of the optical fiber. This was achieved by exposing a section of the core of the optical fiber probe to the fluorophore solution. Both cylindrical and square optical fiber probes were used for SMD. The fluorescent signals were detected by an intensified charge-coupled device. Single rhodamine 6G molecules have been detected. The number of rhodamine 6G molecules imaged by the optical fiber probe showed an excellent linear relationship with the concentrations of the fluorophores. The SMD scheme was also applied to the imaging of biomolecules, such as molecular beacon DNA molecules, labeled with tetramethylrhodamine. Our results have shown that using an optical fiber is an easy yet effective approach to SMD. It represents a simpler fluorescent method for the detection of single-molecules in solution and at an interface.  相似文献   

10.
张滨  虞启琏 《计量学报》1993,14(4):260-265,312
本文对GRIN透镜的精确光线追迹公式作了推导,介绍了轴位移法对透镜折射率分布的测量方法及相应的数据处理,并对测量误差进行了分析和计算,从而对测定GRIN透镜折射率分布提供了一种精确而且实用的方法。  相似文献   

11.
A gradient-index (GRIN) endoscope can be constructed by substituting for the usual objective and relay sections suitable cylindrical index-distribution rod lenses. Currently available GRIN lenses exhibit large amounts of chromatic aberration. Axial color arises mostly from the relay lens, while lateral color is due to the objective lens. A negative lens cemented to a shortened GRIN relay lens can simultaneously correct axial and lateral chromatic aberrations with commercially available components. This correction system reduces the requirements for mechanical centration better than do color correctors that are incorporated into the ocular design. Monochromatic aberrations are also considered.  相似文献   

12.
The development is described of fiber Bragg grating (FBG) probes with single or four cores using spheres fixed onto optical fibers comprising Bragg gratings in their cores. Simulations and preliminary experiments were conducted to evaluate the performance of these FBG probes for dimensional metrology with micro parts of high aspect ratio. Simulation and experimental results indicate that a one-dimensional FBG probe with single core can be used to achieve an axial resolution of 100 nm at an aspect ratio of 15:1. A three-dimensional FBG probe with four cores can be used to achieve a theoretical axial resolution as high as that of a FBG probe with single core, with a capability of decoupling two-dimensional radial displacements with a resolution of 13 nm.  相似文献   

13.
天津大学光纤传感技术研究部分最新进展   总被引:4,自引:1,他引:3  
本文介绍了天津大学在光纤传感技术研究领域的最新进展.主要为:基于白光干涉实现了非本征光纤法珀和FBG并行解调,法珀腔长测量误差0.81 μm,FBG波长测量误差14 pm;基于光纤有源内腔结构夹现了乙炔气体传感,灵敏度优于100ppm;基于保偏光纤实现了分布式传感,灵敏度可达6 cm;基于边缘滤波器开发了光纤光栅解调仪,波长分辨力可达1.2pm,扫描速率超过200kHz;采用全光纤OCT技术实现了牙齿模型的二维、三维扫描;实现了光纤陀螺光纤环的温度、振动等动态特性检测.  相似文献   

14.
B He  L Xi  SR Samuelson  H Xie  L Yang  H Jiang 《Applied optics》2012,51(20):4678-4683
A novel handheld probe based on a microelectromechanical systems (MEMS) scanning mirror for three-dimensional (3D) fluorescence molecular tomography (FMT) is described. The miniaturized probe consists of a MEMS mirror for delivering an excitation light beam to multiple preselected points at the tissue surface and an optical fiber array for collecting the fluorescent emission light from the tissue. Several phantom experiments based on indocyanine green, an FDA approved near-infrared (NIR) fluorescent dye, were conducted to assess the imaging ability of this device. Tumor-bearing mice with systematically injected tumor-targeted NIR fluorescent probes were scanned to further demonstrate the ability of this MEMS-based FMT for imaging small animals.  相似文献   

15.
Khan RR  Dhadwal HS  Suh K 《Applied optics》1994,33(25):5875-5881
An integrated fiber-optic probe comprising a short length of multimode fiber that is fusion spliced to a monomode optical fiber has been fabricated for imaging and nonimaging applications. The fiber probe, typically 250 μm in diameter, can deliver a focused Gaussian spot approximately 25 μm in diameter at a distance of approximately 500 μm from the tip. Two off-the-shelf graded-index multimode fibers have been used in the fabrication of imaging and nonimaging probes. These integrated probes have considerably improved the spatial resolution of backscatter lensless fiber probes being utilized in the dynamic light-scattering characterization of colloidal suspension.  相似文献   

16.
Optical fibre dosemeter systems based on radioluminescence and optically stimulated luminescence (OSL) from carbon-doped aluminium oxide (Al(2)O(3):C) crystals were developed for in vivo real-time dose rate and absorbed dose measurements in radiotherapy and mammography. A technique was also developed for making ultra-small dosemeter probes that can easily be placed inside patients in radiation treatment. These probes have shown excellent properties in both head and neck intensity-modulated radiation therapy treatment and in mammography. The dose-response of the OSL signal for the new optical fibre dosemeter system showed a repeatability within 0.15% at a dose level of 60 mGy when integrated over 100 s. The temperature dependence in the range 0-45 degrees C showed a reproducibility within 1.3% when the OSL signal was integrated over 100 s.  相似文献   

17.
提出了一种高速光学相干层析(OCT)成像技术方案。利用柱面镜的成像特性将传统OCT的点聚焦成像模式改变为线聚焦成像模式,从而降低二维OCT图像的扫描维数,达到提高成像速度的目的。利用ZEMAX光学软件对系统进行光线追迹获得光束经过柱面镜后的聚焦情况。随后采用635nm的激光光源和柱面镜构建了实验系统,实验结果很好地验证了光线追迹仿真结果。  相似文献   

18.
A fiber-optic collimator that emits a Gaussian beam with its beam waist at a certain distance after the exit face of the lens is labeled a self-imaging collimator. For such a collimator, the waist of the emitted Gaussian beam and its location are partly dependent on the properties of the gradient-index (GRIN) lens. Parameters for the self-imaging collimator are formulated in terms of the parameters of a GRIN lens (e.g., pitch, core refractive index, gradient index, length) and the optical wavelength. Next, by use of the Gaussian beam approximation, a general expression for the coupling power loss between two self-imaging-type single-mode fiber (SMF) collimators is, for the first time to our knowledge, derived as a function of three types of misalignment, namely, separation, lateral offset, and angular tilt misalignment. A coupling experiment between two self-imaging collimators with changing separation distance is successfully performed and matches the proposed self-imaging mechanism coupling loss theory. In addition, using a prism, lateral offset, as well as angular tilt, misalignments are experimentally simulated for a two self-imaging collimator coupling condition by a single collimator reflective test geometry. Experimental results agree well with the proposed loss formulas for self-imaging GRIN lenses. Hence, for the first time to our knowledge, the mathematical foundations are laid for employing self-imaging-type fiber collimators in SMF-based free-space systems allowing optimal design for ultra-low-loss coupling.  相似文献   

19.
Fu L  Gan X  Gu M 《Applied optics》2005,44(34):7270-7274
We report on the experimental investigation into the characterization of two-photon fluorescence microscopy based on the separation distance of a single-mode optical fiber coupler and a gradient-index (GRIN) rod lens. The collected two-photon fluorescence signal exhibits a maximum intensity at a defined separation distance (gap length) where the increasing effective excitation numerical aperture is balanced by the decreasing confocal emission collection. A maximum signal is found at gap lengths of approximately 2, 1.25, and 1.75 mm for GRIN lenses with pitches of 0.23, 0.25, and 0.29 wavelength at 830 nm. The maximum two-photon fluorescence signal collected corresponds to a threefold reduction of axial resolution (38.5 microm at 1.25 mm), compared with the maximum resolution (11.6 microm at 5.5 mm), as shown by the three-dimensional imaging of 10 microm beads. These results demonstrate an intrinsic trade-off between signal collection and axial resolution.  相似文献   

20.
The correspondence between the linear integral transform and the ray-transfer matrix of a first-order optical system is used to evaluate the transmittance function of gradient-index (GRIN) human lens regarded as a quadratic phase transformer. The size of the GRIN crystalline lens has been considered for redefining the effective transmittance function by the pupil function. The role that the GRIN nature of the human lens plays in the retinal image quality using the point spread function (PSF) is commented on. The simulation results show that the effective radius of the output face of the lens decreases with increasing thickness and that it is higher for flat end surfaces than for curved end faces. On the other hand, the simulation results also show, for small pupil sizes, that the GRIN nature of the human lens is a retinal image degradation source producing the spread of the PSF and that the curved end surfaces of the lens constitute a retinal image quality improve factor contributing to the narrowing of the PSF.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号