首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Here we describe an on-line method for measuring delta(37)Cl values of chloride bearing salts, waters, and organic materials using multicollector continuous-flow isotope ratio mass spectrometry (CF-IRMS). Pure AgCl quantitatively derived from total Cl in water, inorganic Cl salts, and biological samples was reacted with iodomethane in evacuated 10-mL stopper sealed glass vials to produce methyl chloride gas. A GV Instruments Multicollector CF-IRMS with CH(3)Cl optimized collector geometry was modified to accommodate a headspace single-sample gas injection port prior to a GC column. The GC column was a 2-m Porapak-Q packed column held at 160 degrees C. The resolved sample CH(3)Cl was introduced to the IRMS source in a helium stream via an open split. delta(37)Cl values were calculated by measurement of CH(3)Cl at m/z 52/50 and by comparison to a reference pulse of CH(3)Cl calibrated to standard mean ocean chloride. Sample CH(3)Cl analysis time was approximately 6 min. Injections of 40 microL of pure CH(3)Cl gas yielded a repeatability (+/-SD) of +/-0.06 per thousand for delta(37)Cl (n = 10). Combined GC and IRMS source linearity for CH(3)Cl was <0.2 per thousand/nA (V) peak height. External repeatability, based on processing of seawater and NaCl reference solutions, was better than +/-0.08 per thousand. The smallest sample for delta(37)Cl analysis by this method was approximately 0.2 micromol of Cl. Selected results from a river basin and biological samples study illustrate the potential of on-line chlorine isotope assays in environmental pollution studies.  相似文献   

2.
Lithium isotope composition of basalt glass reference material   总被引:2,自引:0,他引:2  
We present data on the lithium isotope compositions of glass reference materials from the United States Geological Survey (USGS) and the National Institute of Standards and Technology (NIST) determined by multicollector inductively coupled plasma mass spectrometry (MC-ICPMS), thermal ionization mass spectrometry (TIMS), and secondary ionization mass spectrometry (SIMS). Our data on the USGS basaltic glass standards agree within 2 per thousand, independent of the sample matrix or Li concentration. For SIMS analysis, we propose use of the USGS glasses GSD-1G (delta(7)Li 31.14 +/- 0.8 per thousand, 2sigma) and BCR-2G (delta(7)Li 4.08 +/- 1.0 per thousand, 2sigma) as suitable standards that cover a wide range of Li isotope compositions. Lithium isotope measurements on the silica-rich NIST 600 glass series by MC-ICPMS and TIMS agree within 0.8 per thousand, but SIMS analyses show systematic isotopic differences. Our results suggest that SIMS Li isotope analyses have a significant matrix bias in high-silica materials. Our data are intended to serve as a reference for both microanalytical and bulk analytical techniques and to improve comparisons between Li isotope data produced by different methodologies.  相似文献   

3.
Sulfur isotope measurements offer comprehensive information on the origin and history of natural materials. Tunable laser spectroscopy is a powerful analytical technique for isotope analysis that has proven itself readily adaptable for in situ terrestrial and planetary measurements. Measurements of delta(34)S in SO2 were made using tunable laser spectroscopy of combusted gas samples from six sulfur-bearing solids with delta(34)S ranging from -34 to +22 per thousand (also measured with mass spectrometry). Standard deviation between laser and mass spectrometer measurements was 3.7 per thousand for sample sizes of 200 +/- 75 nmol SO(2). Although SO(2)(g) decreased 9% over 15 min upon entrainment in the analysis cell from wall uptake, observed fractionation was insignificant (+0.2 +/- 0.6 per thousand). We also describe a strong, distinct (33)SO(2) rovibrational transition in the same spectral region, which may enable simultaneous delta(34)S and Delta(33)S measurements.  相似文献   

4.
Sulfur (S) isotopes have been used to apportion the amount of biogenic and anthropogenic sulfate in remote environments, an important parameter that is used to model the global radiation budget. A key assumption in the apportionment calculations is that there is little isotope selectivity as reduced compounds such as dimethyl sulfide (DMS) are oxidized. This paper describes a method to determine, for the first time, the S isotope composition of methanesulfonic acid (MSA), the product of DMS oxidation. The isotope composition of MSA was measured directly by EA-IRMS and was used as an isotope reference for the method. Synthetic mixtures approximating the conditions expected for aerosol MSA samples were prepared to test this method. First, MSA solutions were measured alone and then in combination with MSA and SO4(2-). In synthetic mixtures, SO4(2-) was separated from MSA by precipitating it as BaSO4 prior to preparation of MSA for isotope analysis. The delta 34S value for MSA solutions was -2.6 per thousand (SD +/- 0.4 per thousand), which is not different from the delta 34S obtained from MSA filtrate after precipitating SO4(2-) from the mixture (-2.7 +/- 0.3 per thousand). However, these values are offset from direct EA-IRMS analysis of MSA used as the isotope reference by -1.1 +/- 0.2 per thousand, and this must be accounted for in reporting MSA measurements. The S isotope measurements using this method approach a limiting value above 300 microg of MSA. This is approximately equal to the MSA found in 20,000 m3 of air, assuming ambient concentrations of approximately 15 ng m(-3). Three samples of MSA from the Pacific Ocean measured using this technique have an average delta 34S value of +17.4 +/- 0.7 per thousand.  相似文献   

5.
Chlorine stable isotope ratios, 37Cl/35Cl, currently are measured using dual-inlet and thermal-ionization mass spectrometry. These two different analytical techniques, however, have never been cross calibrated. A set of samples with chlorine stable isotope delta values ranging from -4.4 to +0.3 % relative to standard mean ocean water chloride has been analyzed using both of these techniques. Our data show that both techniques can yield similar results within analytical uncertainty. CsCl thermal ionization data are extremely sensitive to the amount of chlorine being measured and cannot be used to determine absolute ratios without an independent means of correcting for machine-induced mass fractionation. As long as standards and samples are of equivalent size, however, the differences between samples measured by thermal ionization remain constant Dual inlet stable isotope mass spectrometry is suited best for samples of > 10 micromol Cl, yielding chlorine stable isotope data with < or =0.1% reproducibilities (2sigma). Thermal ionization mass spectrometry easily accommodates samples of approximately0.1-0.3 micromol Cl, with achievable uncertainties of < or =0.2% (2sigma).  相似文献   

6.
Interlaboratory comparisons involving nine European stable isotope laboratories have shown that the routine methods of cellulose preparation resulted in data that generally agreed within the precision of the isotope ratio mass spectrometry (IRMS) method used: +/-0.2 per thousand for carbon and +/-0.3 per thousand for oxygen. For carbon, the results suggest that holocellulose is enriched up to 0.39 per thousand in 13C relative to the purified alpha-cellulose. The comparisons of IRMS measurements of carbon on cellulose, sugars, and starches showed low deviations from -0.23 to +0.23 per thousand between laboratories. For oxygen, IRMS measurements varied between means from -0.39 to 0.58 per thousand, -0.89 to 0.42 per thousand, and -1.30 to 1.16 per thousand for celluloses, sugars, and starches, respectively. This can be explained by different effects arising from the use of low- or high-temperature pyrolysis and by the variation between laboratories in the procedures used for drying and storage of samples. The results of analyses of nonexchangeable hydrogen are very similar in means with standard deviations between individual methods from +/-2.7 to +/-4.9 per thousand. The use of a one-point calibration (IAEA-CH7) gave significant positive offsets in delta2H values up to 6 per thousand. Detailed analysis of the results allows us to make the following recommendations in order to increase quality and compatibility of the common data bank: (1) removal of a pretreatment with organic solvents, (2) a purification step with 17% sodium hydroxide solution during cellulose preparation procedure, (3) measurements of oxygen isotopes under an argon hood, (4) use of calibration standard materials, which are of similar nature to that of the measured samples, and (5) using a two-point calibration method for reliable result calculation.  相似文献   

7.
The relevance of both modern and fossil carbon contamination as well as isotope fractionation during preparative gas chromatography for compound-specific radiocarbon analysis (CSRA) was evaluated. Two independent laboratories investigated the influence of modern carbon contamination in the sample cleanup procedure and preparative capillary gas chromatography (pcGC) of a radiocarbon-dead 3,3',4,4',5,5'-hexachlorobiphenyl (PCB 169) reference. The isolated samples were analyzed for their 14C/12C ratio by accelerator mass spectrometry. Sample Delta14C values of -996 +/- 20 and -985 +/- 20 per thousand agreed with a Delta14C of -995 +/- 20 per thousand for the unprocessed PCB 169, suggesting that no significant contamination by nonfossil carbon was introduced during the sample preparation process at either laboratory. A reference compound containing a modern 14C/12C ratio (vanillin) was employed to evaluate process contamination from fossil C. No negative bias due to fossil C was observed (sample Delta14C value of 165 +/- 20 per thousand agreed with Delta14C of 155 +/- 12 per thousand for the unprocessed vanillin). The extent of isotopic fractionation that can be induced during pcGC was evaluated by partially collecting the vanillin model compound of modern 14C/12C abundance. A significant change in the delta13C and delta14C values was observed when only parts of the eluting peak were collected (delta13C values ranged from -15.75 to -49.91 per thousand and delta14C values from -82.4 to +4.71 per thousand). Delta14C values, which are normalized to a delta13C of -25 per thousand, did not deviate significantly (-58.9 to -5.8 per thousand, considering the uncertainty of approximately +/-20 per thousand). This means that normalization of radiocarbon results to a delta13C of -25 per thousand, normally performed to remove effects of environmental isotope fractionation on 14C-based age determinations, also cor-rects sufficiently for putative isotopic fractionation that may occur during pcGC isolation of individual compounds for CSRA.  相似文献   

8.
A new methodology for bromine stable isotope determination by continuous-flow isotope ratio mass spectrometry (CF-IRMS) was developed. The technique was tested on inorganic samples. Inorganic bromide was precipitated in the form of silver bromide by using silver nitrate in a standard methodology. Bromine stable isotope analysis was carried out on methyl bromide (CH3Br) after converting silver bromide to methyl bromide by reacting it with methyl iodide (CH3I). The system used in this study is an IsoPrime IRMS, with analytical capabilities of both dual-inlet and continuous-flow modes coupled with an Agilent 6890 GC equipped with a CTC Analytics CombiPAL autosampler. This new technique measures samples as small as 0.2 mg of AgBr (1 micromol of Br-). The bromine stable isotope analysis using continuous flow technology showed excellent precision and accuracy. The internal precision using pure methyl bromide gas is better than +/-0.03 per thousand (+/-SD); the external precision using seawater standard is better than +/-0.06 per thousand (+/-SD) for n = 12. Moreover, the sample analysis time is 16 min, as compared to 75 min needed in previous techniques. This allows for 50 samples to be analyzed in 1 day, as compared to 8 samples using the conventional techniques. A series of natural saline formation waters and brines from sedimentary and crystalline rock environments was measured by this new methodology to test the potential natural range of delta81Br. The bromine isotopic composition of the samples ranged from 0.00 to +1.80 per thousand relative to standard mean ocean bromide (SMOB). Initial trends and distinctive isotopic difference were noticed between crystalline shield brines and sedimentary formation brines.  相似文献   

9.
Intramolecular carbon isotope ratios reflect the source of a compound and the reaction conditions prevailing during synthesis and degradation. We report here a method for determination of relative (Deltadelta13C) and absolute (delta13C) intramolecular isotope ratios using the volatile lactic acid analogue propylene glycol as a model compound, measured by on-line gas chromatography-pyrolysis coupled to GC-combustion-isotope ratio mass spectrometry. Pyrolytic fragmentation of about one-third of the analyte mass produces optimal fragments for isotopic analysis, from which relative isotope ratios (Deltadelta13C) are calculated according to guidelines presented previously. Calibration to obtain absolute isotope ratios is achieved by quantifying isotope fractionation during pyrolysis with an average fractionation factor, alpha, and evaluated by considering extremes in isotopic fractionation behavior. The method is demonstrated by calculating ranges of absolute intramolecular isotope ratios in four samples of propylene glycol. Relative and absolute isotope ratios were calculated with average precisions of SD(Deltadelta13C) <0.84 per thousand and SD(delta13C) <3.0 per thousand, respectively. The various fractionation scenarios produce an average delta(13)C range of 2 per thousand for each position in each sample. Relative isotope ratios revealed all four samples originated from unique sources, with samples A, B, and D only distinguishable at the position-specific level. Regardless of pyrolysis fractionation distribution, absolute isotope ratios showed a consistent pattern for all samples, with delta13C(3) > delta13C(2) > delta13C(1). The validity of the method was determined by examining the difference in relative isotope ratios calculated through two independent methods: Deltadelta13C calculated directly using previous methods and Deltadelta13C extracted from absolute isotope ratios. Deviation between the two Deltadelta13C values for all positions averaged 0.1-0.2 per thousand, with the smallest deviation obtained assuming equal fractionation across all fragment positions. This approach applies generally to all compounds analyzed by pyrolytic PSIA.  相似文献   

10.
Two methods have been used to measure the chlorine leaving group kinetic isotope effect for the S(N)2 reduction of benzyl chloride to toluene by sodium borohydride in DMSO at 30.000 °C. The reaction was monitored by titrating the unreacted borohydride ion. One method involved determining the chlorine isotope effect using the classical IRMS method, which requires the conversion of the chloride ions into gaseous methyl chloride that is analyzed in an isotope ratio mass spectrometric analyses (Hill, J. W.; Fry, A. J. Am. Chem. Soc. 1962, 84, 2763. Taylor, J. W.; Grimsrud, E. P. Anal. Chem. 1969, 41, 805.). Two different measurements using this method yielded isotope effects of k(35)/k(37) = 1.007?19 ± 0.000?19 and 1.007?64 ± 0.000?19. The second method was a new technique where the ratio of the chlorine isotopes was obtained by fast atom bombardment mass spectrometry on the silver chloride recovered from the reaction, i.e., from the first step in the classical procedure. Therefore, the new method is much simpler and avoids the time-consuming preparation, purification, and recovery of the gaseous methyl chloride. Although the experimental error is larger (k(35)/k(37) = 1.008?03 ± 0.00?10 and 1.008?02 ± 0.000?65) when the new technique is used to analyze the silver chloride samples from the same set of experiments that were used to measure the isotope effect by the classical method, the chlorine isotope effect found by the two methods is identical within experimental error. This large chlorine kinetic isotope effect indicates there is considerable C(α)-Cl bond rupture in the S(N)2 transition state.  相似文献   

11.
We report an automated method for high-precision position-specific isotope analysis (PSIA) of carbon in amino acid analogues. Carbon isotope ratios are measured for gas-phase pyrolysis fragments from multiple sources of 3-methylthiopropylamine (3MTP) and isoamylamine (IAA), the decarboxylated analogues of methionine and leucine, using a home-built gas chromatography (GC)-pyrolysis-GC preparation system coupled to a combustion-isotope ratio mass spectrometry system. Over a temperature range of 620-900 degrees C, the characteristic pyrolysis products for 3MTP were CH4, C2H6, HCN, and CH3CN and for IAA products were propylene, isobutylene, HCN, and CH3CN. Fragment origin was confirmed by 13C-labeling, and fragments used for isotope analysis were generated from unique moieties with > 95% structural fidelity. Isotope ratios for the fragments were determined with an average precision of SD(delta13C) < 0.3% per thousand, and relative isotope ratios of fragments from different sources were determined with an average precision of SD(delta(delta)13C) < 0.5% per thousand. Delta(delta)13C values of fragments were invariant over a range of pyrolysis temperatures. The delta(delta)13C of complementary fragments in IAA was within 0.8% per thousand of the delta(delta)13C of the parent compounds, indicating that pyrolysis-induced isotopic fractionation is effectively taken into account with this calibration procedure. Using delta(delta)13C values of fragments, delta(delta)13C values were determined for all four carbon positions of 3MTP and for C1, C2, and the propyl moiety of IAA, either directly or indirectly by mass balance. Large variations in position-specific isotope ratios were observed in samples from different commercial sources. Most dramatically, two 3MTP sources differed by 16.30% per thousand at C1, 48.33% per thousand at C2, 0.37% per thousand at C3, and 5.36% per thousand at C(methyl). These PSIA techniques are suitable for studying subtle changes in intramolecular isotope ratios due to natural processes.  相似文献   

12.
A thermal decomposition method was developed and tested for the simultaneous determination of delta 18O and delta 17O in nitrate. The thermal decomposition of AgNO3 allows for the rapid and accurate determination of 18O/ 16O and 17O/16O isotopic ratios with a precision of +/- 1.5 per thousand for delta 18O and +/- 0.11 per thousand for delta 17O (delta 17O = delta 17O - 0.52 x delta 18O). The international nitrate isotope reference material IAEA-NO3 yielded a delta 18O value of +23.6 per thousand and delta 17O of -0.2 per thousand, consistent with normal terrestrial mass-dependent isotopic ratios. In contrast, a large sample of NaNO3 from the Atacama Desert, Chile, was found to have delta 17O = 21.56 +/- 0.11 per thousand and delta 18O = 54.9 +/- 1.5 per thousand, demonstrating a substantial mass-independent isotopic composition consistent with the proposed atmospheric origin of the desert nitrate. It is suggested that this sample (designated USGS-35) can be used to generate other gases (CO2, CO, N2O, O2) with the same delta 17O to serve as measurement references for a variety of applications involving mass-independent isotopic compositions in environmental studies.  相似文献   

13.
We report the first coupling of comprehensive two-dimensional gas chromatography (GC x GC) to online combustion isotope ratio mass spectrometry (C-IRMS). A GC x GC system, equipped with a longitudinally modulated cryogenic system (LMCS), was interfaced to an optimized low dead volume combustion interface to preserve <300 ms full width at half-maximum (fwhm) fast GC peaks generated on the second GC column (GC2). The IRMS detector amplifiers were modified by configuration of resistors and capacitors to enable fast response, and a home-built system acquired data at 25 Hz. Software was home-written to handle isotopic time shifts of less than one bin (40 ms) and to integrate peak slices to recover isotope ratios from cryogenically sliced peaks. The performance of the GC x GCC-IRMS system was evaluated by isotopic analysis of urinary steroid standards. Steroids were separated by a nonpolar GC1 column (30 m x 0.25 mm, 5% phenyl), modulated into multiple 4- or 8-s cryogenic slices by the LMCS, and then separated on a polar GC2 column (1 or 2 m x 0.1 mm, 50% phenyl). GC2 peak widths from a 1-m column averaged 276 ms fwhm. Steroid standard sliced peaks were successfully reconstructed to yield delta(13)C VPDB values with average precisions of SD(delta(13)C) = 0.30 per thousand and average accuracies within 0.34 per thousand, at 8 ng on column. Two steroids, coeluting in GC1, were baseline separated in GC2 and resulted in delta(13)C VPDB values with average precisions of SD(delta(13)C) = 0.86 per thousand and average accuracies within 0.26 per thousand, at 3 ng on column. Results from this prototype system demonstrate that the enhanced peak capacity and signal available in GC x GC is compatible with high-precision carbon isotope analysis.  相似文献   

14.
We present the first measurements of Fe isotope variations in chemically purified natural samples using high mass resolution multiple-collector inductively coupled plasma source mass spectrometry (MC-ICPMS). High mass resolution allows polyatomic interferences at Fe masses to be resolved (especially, (40)Ar(14)N(+), (40)Ar(16)O(+), and (40)Ar(16)OH(+)). Simultaneous detection of Fe isotope ion beams using multiple Faraday collectors facilitates high-precision isotope ratio measurements. Fe in basalt and paleosol samples was extracted and purified using a simple, single-stage anion chemistry procedure. A Cu "element spike" was used as an internal standard to correct for variations in mass bias. Using this procedure, we obtained data with an external precision of 0.03-0.11 per thousand and 0.04-0.15 per thousand for delta(56/54)Fe and delta(57/54)Fe, respectively (2sigma). Use of Cu was necessary for such reproducibility, presumably because of subtle effects of residual sample matrix on mass bias. These findings demonstrate the utility of high-resolution MC-ICPMS for high-precision Fe isotope analysis in geologic and other natural materials. They also highlight the importance of internal monitoring of mass bias, particularly when using routine methods for Fe extraction and purification.  相似文献   

15.
Solid-phase microextraction (SPME) coupled to gas chromatography/isotope ratio mass spectrometry was used to determine the delta15N and delta13C signatures of selected nitroaromatic contaminants such as the explosive 2,4,6-trinitrotoluene (TNT) for derivation of isotopic enrichment factors of contaminant transformation. Parameters for efficient extraction of nitroaromatic compounds (NACs) and substituted anilines from water samples were evaluated by SPME-GC/MS. delta13C signatures determined by SPME-GC/IRMS and elemental analyzer IRMS (EA-IRMS) were in good agreement, generally within +/-0.7 per thousand, except for 2,4-dinitrotoluene (2,4-DNT) and TNT, which showed slight deviations (<1.3 per thousand). Limits of detection (LODs) for delta13C analysis by SPME-GC/IRMS were between 73 and 780 microg L-1 and correlated with the extraction efficiencies of the compounds determined by SPME-GC/MS. Nitrogen isotope measurements by SPME-GC/IRMS were of similar precision (standard deviations <0.8 per thousand) for all NACs except for TNT. delta15N signatures matched the reference values obtained by EA-IRMS within +/-1.3 per thousand (+2.5 per thousand for TNT), but no systematic trend was found for the deviations. LODs of delta15N measurements ranged from 1.6 to 9.6 mg L-1 for nitrotoluenes, chlorinated NACs and DNTs (22 mg L-1 for TNT). The SPME-GC/IRMS method is well suited for the determination of isotopic enrichment factors of various NAC transformation processes and provides so far unexplored possibilities to elucidate behavior and degradation mechanisms of nitroaromatic contaminants in soils and groundwaters.  相似文献   

16.
A continuous flow method (CF-IRMS) for the rapid determination of the sulfur isotope composition of sulfide and sulfate minerals has significant advantages over the classic extraction method in terms of the reduced sample quantity and a rapid analytical cycle of less than 8 min/ analysis. For optimum performance, the technique is sensitive to a number of operating parameters, including sample weight and the O2 saturation of the Cu-reduction reactor. Raw data are corrected using a calibration based on five international and internal standards ranging from -17.3 to +20.3 per thousand, which requires monitoring in order to correct the effect of changing delta18O of the sample gas on the measured mass 66 values. Measured sulfur contents are within 1-1.5% of expected values and the reproducibility of delta34S values is +/-0.1 per thousand (1sigma). The technique has been used successfully for more than 1000 analyses of geological samples with a wide range of delta34S from -20 to +20 per thousand.  相似文献   

17.
This work presents the simultaneous online determination of the isotopic composition of different Hg species in a single sample by the hyphenation of gas chromatography (GC) with multicollector-inductively coupled plasma mass spectrometry (MC-ICPMS). With the use of commercially available instrumentation, precise and accurate species-specific Hg isotope delta values (per mil deviation of the Hg isotope ratio in the sample relative to a reference standard) have been obtained online from consecutive GC transient signals. The use of isothermal temperature programs to extend the elution of the Hg species, the proper selection of the peak integration window, as well as the preconcentration of real samples are critical to provide optimal counting statistics. Also, isotope ratio drift during transient signal elution was overcome by introducing a mixed Hg(II) and MeHg standard bracketing scheme and expressing all results using the delta-notation relative to SRM NIST-3133. Using the proposed methodology, we have obtained an external 2SD precision of 0.56 per thousand for delta (202)Hg that is more than 10 times smaller than the overall Hg stable isotope variation thus far observed in terrestrial samples. The measurement of species-specific Hg isotopic composition relative to SRM NIST-3133 has been validated versus two other analytical techniques, i.e., conventional nebulization (CN) of Hg(II) solution and cold vapor (CV) generation of Hg (0) vapor. A good agreement between the species-specific delta values obtained by the different techniques has been obtained in secondary fractionated reference standard (UM-Almaden) and environmental matrixes, i.e., BCR-CRM 464 (tuna fish) and IAEA-085 (human hair). The results show mass-dependent and mass-independent fractionation in environmental samples, i.e., mass-independent fractionation of odd isotopes (199)Hg and (201)Hg in tuna fish was observed. This methodology provides new possibilities for the future study of species-specific stable isotope geochemistry of Hg and other trace metals.  相似文献   

18.
Three different KNO3 salts with delta18O values ranging from about -31 to +54 per thousand relative to VSMOW were used to compare three off-line, sealed glass tube combustion methods (widely used for isotope studies) with a more recently developed on-line carbon combustion technique. All methods yielded roughly similar isotope ratios for KNO3 samples with delta18O values in the midpoint of the delta18O scale near that of the nitrate reference material IAEA-NO-3 (around +21 to +25 per thousand). This reference material has been used previously for one-point interlaboratory and intertechnique calibrations. However, the isotope ratio scale factors by all of the off-line combustion techniques are compressed such that they are between 0.3 and 0.7 times that of the on-line combustion technique. The contraction of the 6180 scale in the off-line preparations apparently is caused by O isotope exchange between the sample and the glass combustion tubes. These results reinforce the need for nitrate reference materials with delta18O values far from that of atmospheric O2, to improve interlaboratory comparability.  相似文献   

19.
A novel derivatization procedure, N-acetyl methyl (NACME) esterification, was developed to improve the accuracy and precision of amino acid delta13C value determination using gas chromatography-combustion-isotope ratio mass spectrometry (GC/C/IRMS). Standard mixtures of 15 protein amino acids were converted to NACME and N-acetyl-isopropyl (NAIP) esters; the latter established derivative was employed for comparison purposes. Both procedures yielded baseline-resolved peaks for all 15 amino acids when GC columns coated with polar stationary phases were employed. For NACME esters, the methylation conditions governed reaction yields, with highest yields observed when a 1 h, 70 degrees C methylation procedure (anhydrous MeOH/acetyl chloride, 25:4, v/v) was performed. The mean derivatization yields expressed relative to an underivatized coinjected standard (n-nonadecane) for both NACME and NAIP esters were identical. Likewise, the mean kinetic isotope effects (KIEs) were not significantly different (KIE(NACME) = 1.036; KIE(NAIP) = 1.038) and were shown in both cases to be reproducible. The mean reproducibility obtained from 15 replicates (3 x batches of 5) of both derivatives was strong (mean STDV(NACME) = 0.3 per thousand and STDV(NAIP) = 0.4 per thousand). The isotopic robustness of both derivatization procedures was observed over a concentration range of 52,500 microg of amino acid. NACME esters displayed low errors (+/-0.6 per thousand for phenylalanine to +/-1.1 per thousand for serine) due to the higher sample-to-derivative carbon ratio of this derivative. Finally, the integrity of the new NACME procedure was confirmed through analysis of diet and bone collagen amino acids of rats reared on C3 or C4 diets, which indicated the high degree of both accuracy and precision of the delta13C values obtained for individual amino acids.  相似文献   

20.
Isotopic variations of Zn in biological materials   总被引:3,自引:0,他引:3  
Variations in the isotopic composition of Zn present in various biological materials were determined using high-resolution multicollector inductively coupled plasma mass spectrometry (MC-ICPMS), following digestion and purification by anion exchange chromatography. To correct for differences in instrumental mass discrimination effects between samples and standards, Cu was employed as an elemental spike. Complementary analyses of Zn separates by sector field ICPMS instruments revealed that the concentrations of the majority of potentially interfering elements were reduced to negligible levels. Residual spectral interferences resulting from (35)Cl(16)O(2)(+), (40)Ar(14)N(2)(+), and (40)Ar(14)N(16)O(+) could be instrumentally resolved from the (67)Zn, (68)Zn, and (70)Zn ion beams, respectively, during measurement by MC-ICPMS. The only other observed interference in the Cu and Zn mass range that could not be effectively eliminated by high-resolution multicollection resulted from (35)Cl(2)(+), necessitating modification of the sample preparation procedure to allow accurate (70)Zn detection. Complete duplication of the entire analytical procedure for human whole blood and hair, as well as bovine liver and muscle, provided an external reproducibility of 0.05-0.12 per thousand (2sigma) for measured delta(66/64)Zn, delta(67/64)Zn, and delta(68/64)Zn values, demonstrating the utility of the method for the precise isotopic analysis of Zn in biological materials. Relative to the selected Zn isotopic standard, delta(66/64)Zn values for biological samples varied from -0.60 per thousand in human hair to +0.56 per thousand in human whole blood, identifying the former material as the isotopically lightest Zn source found in nature to date.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号