首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Micro-strip metal-semiconductor-metal detectors for thermal neutron sensing were fabricated from hexagonal boron nitride (hBN) epilayers synthesized by metal organic chemical vapor deposition. Experimental measurements indicated that the thermal neutron absorption coefficient and length of natural hBN epilayers are about 0.00361 μm−1 and 277 μm, respectively. A continuous irradiation with a thermal neutron beam generated an appreciable current response in hBN detectors, corresponding to an effective conversion efficiency approaching ∼80% for absorbed neutrons. Our results indicate that hBN semiconductors would enable the development of essentially ideal solid-state thermal neutron detectors in which both neutron capture and carrier collection are accomplished in the same hBN semiconductor. These solid-state detectors have the potential to replace 3He gas detectors, which faces the very serious issue of 3He gas shortage.  相似文献   

2.
Perforated semiconductor neutron detectors are compact diode detectors that operate at low power and can be fashioned to have high thermal neutron detection efficiency. Fabricated from high-purity Si wafers, the perforations are etched into the diode surface with ICP-RIE and backfilled with 6LiF neutron reactive material. The intrinsic thermal neutron detection efficiency depends upon many factors, including the perforation geometry, size, and depth. Devices were fabricated from high resistivity  cm n-type Si with conformal p-type shallow junction diffusions into the perforations, which demonstrate improved neutron detection performance over previous selectively diffused designs. A comparison was made to previous selectively diffused designs, and pulse height spectra show improved signal-to-noise ratio, higher neutron counting efficiency, and excellent gamma-ray discrimination. Devices with wide deep sinusoidal trenches yielded intrinsic thermal neutron detection efficiencies of 11.94±0.078%.  相似文献   

3.
The shortage of 3He has triggered the search for effective alternative neutron detection technologies for national security and safeguards applications. Any new detection technology must satisfy two basic criteria: (1) it must meet a neutron detection efficiency requirement, and (2) it must be insensitive to gamma-ray interference at a prescribed level, while still meeting the neutron detection requirement. It is the purpose of this paper to define measureable gamma ray sensitivity criteria for neutron detectors. Quantitative requirements are specified for: intrinsic gamma ray detection efficiency and gamma ray absolute rejection. The gamma absolute rejection ratio for neutrons (GARRn) is defined, and it is proposed that the requirement for neutron detection be 0.9<GARRn<1.1 at a 10 mR/h exposure rate. An example of the results from a 3He based neutron detector is provided showing that this technology can meet the stated requirements. Results from tests of some alternative technologies are also reported.  相似文献   

4.
A CdTe detector with a Gd converter has been developed and investigated as a neutron detector for neutron imaging. The fabricated Gd/CdTe detector with the 25 μm thick Gd was designed on the basis of simulation results of thermal neutron detection efficiency and spatial resolution. The energy resolution of the Gd/CdTe detector is less than 4 keV, which is enough to discriminate neutron capture gamma rays from background gamma emission. The Gd/CdTe detector shows the detection of neutron capture gamma ray emission in the 155Gd(n, γ)156Gd, 157Gd(n, γ)158Gd and 113Cd(n, γ)114Cd reactions and characteristic X-ray emissions due to conversion-electrons generated inside the Gd film. The observed efficient thermal neutron detection with the Gd/CdTe detector shows its promise in neutron radiography application.  相似文献   

5.
Nova Scientific Inc., is developing for the Domestic Nuclear Detection Office (DNDO SBIR #HSHQDC-08-C-00190), a solid-state, high-efficiency neutron detection alternative to 3He gas tubes, using neutron-sensitive microchannel plates (MCPs) containing 10B and/or Gd. This work directly supports DNDO development of technologies designed to detect and interdict nuclear weapons or illicit nuclear materials. Neutron-sensitized MCPs have been shown theoretically and more recently experimentally, to be capable of thermal neutron detection efficiencies equivalent to 3He gas tubes. Although typical solid-state neutron detectors typically have an intrinsic gamma sensitivity orders of magnitude higher than that of 3He gas detectors, we dramatically reduce gamma sensitivity by combining a novel electronic coincidence rejection scheme, employing a separate but enveloping gamma scintillator. This has already resulted in a measured gamma rejection ratio equal to a small 3He tube, without in principle sacrificing neutron detection efficiency. Ongoing improvements to the MCP performance as well as the coincidence counting geometry will be described. Repeated testing and validation with a 252Cf source has been underway throughout the Phase II SBIR program, with ongoing comparisons to a small commercial 3He gas tube. Finally, further component improvements and efforts toward integration maturity are underway, with the goal of establishing functional prototypes for SNM field testing.  相似文献   

6.
K6Li(Y1−xCex)F5 (x = 0.003, 0.02) single crystals were grown from the melt using the precise atmosphere control type Micro-Pulling-Down (μ-PD) method to examine their potential as a new thermal neutron scintillators. The grown crystals were single-phase materials as confirmed by XRD. The crystals demonstrated 40-60% transmittance above 320 nm and Ce3+ 5d-4f luminescence observed around 340 nm when exited by α-ray. The radio luminescence measurements under thermal neutron excitation (252Cf) demonstrated the light yield of 890 (Ph/neutron) and the decay time excited by α-ray exhibited 20 and 259 ns.  相似文献   

7.
The improved collimation and intensity of thermal and cold neutron beamlines combined with recent advances in neutron imaging devices enable high-resolution neutron radiography and microtomography, which can provide information on the internal structure of objects not achievable with conventional X-ray imaging techniques. Neutron detection efficiency, spatial and temporal resolution (important for the studies of dynamic processes) and low background count rate are among the crucial parameters defining the quality of radiographic images and tomographic reconstructions. The unique capabilities of neutron counting detectors with neutron-sensitive microchannel plates (MCPs) and with Timepix CMOS readouts providing high neutron detection efficiency (∼70% for cold neutrons), spatial resolutions ranging from 15 to 55 μm and a temporal resolution of ∼1 μs—combined with the virtual absence of readout noise—make these devices very attractive for high-resolution microtomography. In this paper we demonstrate the capabilities of an MCP-Timepix detection system applied to microtomographic imaging, performed at the ICON cold neutron facility of the Paul Scherrer Institute. The high resolution and the absence of readout noise enable accurate reconstruction of texture in a relatively opaque wood sample, differentiation of internal tissues of a fly and imaging of individual ∼400 μm grains in an organic powder encapsulated in a ∼700 μm thick metal casing.  相似文献   

8.
Intrinsic efficiencies of multi-layer boron-10 thin-film detectors were studied theoretically and experimentally. For multi-layer schemes based on an optimized single-layer film thickness, the practical efficiency is limited to about 42% for thermal neutrons. This is about half the efficiency of a moderated 3He detectors in commercial use for portal monitoring. The efficiency limitation is due to charged particle loss in the boron layers and substrates. The same loss mechanism will prevent all substrate-based boron detectors from ever reaching the intrinsic efficiencies of high-pressure 3He tubes, independent of substrate geometry and material composition. Experimental data also indicate that the multi-layer detector configuration can have an efficiency approaching the theoretical limit. Excellent n/γ discrimination has also been achieved using an ionization chamber.  相似文献   

9.
A compact fast neutron detector based on beryllium activation has been developed to perform accurate neutron fluence measurements on pulsed DD fusion sources. It is especially well suited to moderate repetition-rate (<0.2 Hz) devices, such as the plasma focus or Z-pinch. The detector comprises a beryllium metal sheet sandwiched between two large-area xenon-filled proportional counters. A methodology for calculating the absolute response function of the detector using a “first principles” approach is described. This calibration methodology is based on the 9Be(n,α)6He cross-section, energy calibration of the proportional counters, and numerical simulations of neutron interactions and beta-particle paths using MCNP5. The response function R(En) is determined over the neutron energy range 2-4 MeV. The count rate capability of the detector has been studied and the corrections required for high neutron fluence measurements are discussed. For pulsed DD neutron fluencies >3×104 cm−2, the statistical uncertainty in the fluence measurement is better than 1%. A small plasma focus device has been employed as a pulsed neutron source to test two of these new detectors, and their responses are found to be practically identical. Also the level of interfering activation is found to be sufficiently low as to be negligible.  相似文献   

10.
Neutron imaging by color center formation in LiF crystals was applied to a sensitivity indicator (SI) as a standard samples for neutron radiography. The SI was exposed to a 5 mm pinhole-collimated thermal neutron beam with an LiF crystal and a neutron imaging plate (NIP) for 120 min in the JRR-3M thermal neutron radiography facility. The image in the LiF crystal was read out using a laser confocal microscope. All gaps were clearly observed in images for both the LiF crystal and the NIP. The experimental results showed that LiF crystals have excellent characteristics as neutron imaging detectors in areas such as high spatial resolution.  相似文献   

11.
We measured the neutron decay lifetime by counting in-beam neutron decay recoil protons trapped in a quasi-Penning trap. The absolute neutron beam fluence was measured by capture in a thin 6LiF foil detector with known efficiency. The combination of these measurements gives the neutron lifetime: τn = (886.8 ± 1.2 ± 3.2) s, where the first (second) uncertainty is statistical (systematic) in nature. This is the most precise neutron lifetime determination to date using an in-beam method.  相似文献   

12.
Previous work showed that enriched 6Li halide scintillation crystal is a good candidate for portable neutron-sensitive detectors. Photodiode readout is a good alternative to PMT in compact devices. These detectors are often required to work in presence of a strong gamma background. Therefore, great discrimination against gamma rays is crucial. Because of the high Q-value of the 6Li(n,α)3H reaction, the light yield of a neutron capture signal corresponds to 3-4 MeV gamma equivalent in spite of the quenching effect of heavily charged particles. As a result, energy discrimination is quite effective against gamma signals generated in thin crystals. However, direct gamma interactions inside the photodiode can create pulses whose amplitude is large enough to interfere with thermal neutron peak. This study shows an innovative design based on coincident readout to solve this problem. In this design, two photodiodes are attached on both sides of the LiI crystal. The output signal is only accepted when both photodiodes give out coincident output. The method is proved to effectively suppress background in the neutron window in a 420 mR/h 137Cs field down to the level of natural background.  相似文献   

13.
A neutron imaging facility, PKUNIFTY, based on a radio frequency quadrupole (RFQ) accelerator-driven compact neutron source, presently under construction at the Peking University, is described. It consists of a deuteron linear accelerator, a neutron target-moderator-reflector assembly, and a thermal neutron imaging system. Neutrons are generated via the deuteron-beryllium reaction with an expected fast-neutron yield of 3×1012 n/s. The thermal neutron flux on the imaging plane is 5×105 n/cm2/s at a nominal L/D ratio of 50, and the L/D ratio can be selectable over a range of 25-200. The corresponding n/γ ratio is close to or higher than 1×1010 n/cm2/Sv. The field of view is 20 cm×20 cm at 2 m downstream of the collimator entrance aperture where the thermal neutron flux uniformity is better than 7%. The effective Cd ratio can be tuned by using a light chopper and neutron time-of-flight technique without excessive sacrifice of the thermal neutron flux.  相似文献   

14.
Cerium-doped LiCaAlF6 (Ce:LiCAF) crystals have been studied as scintillators in application to thermal neutron detection. Three crystals: high-doping Ce:LiCAF, low-doping Ce:LiCAF with 50% enrichment of 6Li (both 10 mm×10 mm×2 mm, rectangular) and high-doping Ce:LiCAF with 95% enrichment of 6Li (Ø50.8 mm×2 mm, discus) coupled to Photonis XP5300B PMT, were tested. The response of these crystals to neutrons emitted from a paraffin moderated 238PuBe source has been investigated. Thermal neutron peaks have been found at a Gamma Equivalent Energy (GEE) of ∼2.5 MeV for high-doping Ce:LiCAF (50% 6Li), ∼2 MeV for low-doping Ce:LiCAF (50% 6Li) and ∼1.9 MeV for high-doping Ce:LiCAF (95% 6Li). The light output of Ce:LiCAF was also measured (175-250 phe/MeV from sample to sample). Lithium-6 glass GS20 from Saint Gobain was used as a reference scintillator (Ø50 mm×2 mm, circle). Relative neutron efficiency, normalized to that of GS20 lithium glass, as well as gamma-neutron intrinsic efficiency for all tested samples was calculated. Intrinsic efficiency on thermal neutron detection for small Ce:LiCAF samples was estimated at about 32-35% of that of GS20 and for large Ce:LiCAF sample as about 82% of that of GS20.  相似文献   

15.
The Pulsed Neutron Interrogation Test Assembly (PUNITA) is an experimental device for research in NDA methods and field applicable instrumentation for nuclear safeguards and security applications. PUNITA incorporates a standard 14-MeV (D-T) pulsed neutron generator inside a large graphite mantle. The generator target is surrounded by a thick tungsten filter with the purpose to increase the neutron output and to tailor the neutron energy spectrum. In this configuration a sample may be exposed to a relatively high average thermal neutron flux of about (2.2±0.1)×103 s−1 cm−2 at only 10% of the maximum target neutron emission. The sample cavity is large enough to allow variation of the experimental setup including the fissile sample, neutron and gamma detectors, and shielding materials.The response from SNM samples of different fissile material content was investigated with various field-applicable scintillation gamma detectors such as the 3×2 in. LaBr3 detector. Shielding in the form of tungsten and cadmium was applied to the detector to improve the signal to background ratio. Gamma and neutron shields surrounding the samples were also tested for the purpose of simulating clandestine conduct. The energy spectra of delayed gamma rays were recorded in the range 100 keV-9 MeV. In addition time spectra of delayed gamma rays in the range 3.3-8 MeV were recorded in the time period of 10 ms-120 s after the 14-MeV neutron burst. The goal of the experiment was to optimize the sample/detector configuration including the energy range and time period for SNM detection. The results show, for example, that a 170 g sample of depleted uranium can be detected with the given setup in less than 3 min of investigation. Samples of higher enrichment or higher mass are detected in much shorter time.  相似文献   

16.
The Peking University Neutron Imaging Facility (PKUNIFTY) is a Radio Frequency Quadruple (RFQ) accelerator based system. The fast neutrons are produced by 2 MeV deuterons bombarding beryllium target. The moderator, reflector, shielding and collimator have been optimized with Monte-Carlo simulation to improve the neutron beam quality. The neutrons are thermalized in water cylinder of Φ26×26 cm2 with a polyethylene disk in front of Be target. The size of deuteron beam spot is optimized considering both the thermal neutron distribution and the demand of target cooling. The shielding is a combination of 8 cm thick lead and 42 cm thick boron doped polyethylene. The thermal neutrons are extracted through a rectangular inner collimator and a divergent outer collimator. The thermal neutron beam axis is perpendicular to the D+ beam line in order to reduce the fast neutron and the γ ray components in the imaging beam. When the neutron yield is 3×1012 n/s and the L/D is 50, the thermal neutron flux is 5×105 n/cm2/s at the imaging plane, the Cd ratio is 1.63 and the n/γ ratio is 1.6×1010 n/cm2/Sv.  相似文献   

17.
A novel fluorine-functionalized europium(III) ternary complex, i.e., Eu(DBM)3(BFPP), in which DBM was dibenzoylmethane and BFPP 2, 3-bis(4-fluorophenyl)pyrazino[2,3-f] [1,10]phenanthroline, was designed, synthesized and characterized. The complex emits the characteristic red emission of trivalent europium ion due to the 5D0 → 7Fj (j = 0–4) transitions under photo excitation with good luminescent quantum efficiency (0.55) and exhibits high thermal stability (387 °C). The organic light-emitting diodes (OLEDs) employing the complex as a dopant emitter with the structures of ITO/TPD (40 nm)/CBP:Eu-complex (30 nm)/Bphen (10 nm)/Alq3 (20 nm)/LiF (1 nm)/Al (150 nm) were successfully fabricated. The 4 wt.% Eu(DBM)3(BFPP) doped device exhibited the maximum luminance of 1766 cd/m2 and a peak current efficiency of 4.6 cd/A, corresponding to the high external quantum efficiency of 2.27%.  相似文献   

18.
We have detected Lyman alpha radiation, 121.6 nm light produced from the n = 2 to n = 1 transition in atomic hydrogen, as a product of the 3He(n, tp) nuclear reaction occurring in a cell of 3He gas. The predominant source of this radiation appears to be decay of the 2p state of tritium produced by charge transfer and excitation collisions with the background 3He gas. Under the experimental conditions reported here we find yields of tens of Lyman alpha photons for every neutron reaction. These results suggest a method of cold neutron detection that is complementary to existing technologies that use proportional counters. In particular, this approach may provide single neutron sensitivity with wide dynamic range capability, and a class of neutron detectors that are compact and operate at relatively low voltages.  相似文献   

19.
As alternative candidates for the 3He neutron detectors, 6LiF/CaF2:Eu eutectic composites were fabricated and their scintillation properties were evaluated. Large size LiF/CaF2:Eu eutectic composites of 58 mm diameter and 50 mm thickness were produced by Bridgman method. The composites had a finely ordered lamellar structure along the solidification direction. The lamellar structure was controlled by the direction and the rate of solidification, and it was optimized to improve the scintillation properties. Better results were achieved when thinner lamellar layers were aligned along the scintillation light path.  相似文献   

20.
Cryogenic particle detectors have recently been adopted in radiation detection and measurement because of their high energy resolution. Many of these detectors have demonstrated energy resolutions better than the theoretical limit of semiconductor detectors. We report the development of a micro-fabricated magnetic calorimeter coupled to a large-area particle absorber. It is based on a planar, 1 mm2 large paramagnetic temperature sensor made of sputtered Au:Er, which covers a superconducting meander-shaped pickup coil coupled to a low-noise dc-SQUID to monitor the magnetization of the sensor. A piece of gold foil of 2.5×2.5×0.07 mm3 was glued to the Au:Er film to serve as an absorber for incident alpha particles. The detector performance was investigated with an 241Am source. The signal size comparison for alpha and gamma peaks with a large difference in energy demonstrated that the detector had good linear behavior. An energy resolution of 2.83±0.05 keV in FWHM was obtained for 5.5 MeV alpha particles.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号