1.

Objective

The present work introduces an alternative to the conventional \(B_{0}\) -gradient spatial phase encoding technique. By applying far off-resonant radiofrequency (RF) pulses, a spatially dependent phase shift is introduced to the on-resonant transverse magnetization. This so-called Bloch–Siegert (BS) phase shift has been recently used for \(B_{1}^{ + }\) -mapping. The current work presents the theoretical background for the BS spatial encoding technique (BS-SET) using RF-gradients.

Materials and methods

Since the BS-gradient leads to nonlinear encoding, an adapted reconstruction method was developed to obtain undistorted images. To replace conventional phase encoding gradients, BS-SET was implemented in a two-dimensional (2D) spin echo sequence on a 0.5 T portable MR scanner.

Results

A 2D spin echo (SE) measurement imaged along a single dimension using the BS-SET was compared to a conventional SE 2D measurement. The proposed reconstruction method yielded undistorted images.

Conclusions

BS-gradients were demonstrated as a feasible option for spatial phase encoding. Furthermore, undistorted BS-SET images could be obtained using the proposed reconstruction method.  相似文献   

2.
Objective We investigate the implications of high magnetic field strength on MR venography based on susceptibility-weighted imaging (SWI) and estimate the optimum echo time to obtain maximum contrast between blood and brain tissue. Materials and methods We measured tissue contrast and relaxation times at 7 T of gray matter, white matter, and venous blood in vivo. Results relaxation times of gray matter, white matter, and venous blood in vivo yielded 32.9 ± 2.3, 27.7 ± 4.3, and 7.4 ± 1.4 ms, respectively. Optimum TE was found to be 15 ms which is supported by theoretical considerations. Using this optimum TE, we acquired 3D high resolution datasets with a large volume coverage in a short measurement time that show very detailed microanatomical structures of the human brain such as intracortical veins and laminar cortical substructures. Conclusions By applying optimised vessel filters (vesselness filter and vessel enhancing diffusion) whole brain MR venograms can be obtained at 7 T with a significantly reduced measurement time compared to 3 T.  相似文献   

3.

Background and methods

A liquid crystal display was modified for use inside a 7 T MR magnet. SNR measurements were performed using different imaging sequences with the monitor absent, present, or activated. fMRI with a volunteer was conducted using a visual stimulus.

Results and discussion

SNR was reduced by 3.7 %/7.9 % in echo planar/fast-spin echo images when the monitor was on which can be explained by the limited shielding of the coated front window (40 dB). In the fMRI experiments, activated regions in the visual cortex were clearly visible. The monitor provided excellent resolution at minor SNR reduction in EPI images, and is thus suitable for fMRI at ultra-high field.  相似文献   

4.

Object

The post-processing of MR spectroscopic data requires several steps more or less easy to automate, including the phase correction and the chemical shift assignment. First, since the absolute phase is unknown, one of the difficulties the MR spectroscopist has to face is the determination of the correct phase correction. When only a few spectra have to be processed, this is usually performed manually. However, this correction needs to be automated as soon as a large number of spectra is involved, like in the case of phase coherent averaging or when the signals collected with phased array coils have to be combined. A second post-processing requirement is the frequency axis assignment. In standard mono-voxel MR spectroscopy, this can also be easily performed manually, by simply assigning a frequency value to a well-known resonance (e.g. the water or NAA resonance in the case of brain spectroscopy). However, when the correction of a frequency shift is required before averaging a large amount of spectra (due to B 0 spatial inhomogeneities in chemical shift imaging, or resulting from motion for example), this post-processing definitely needs to be performed automatically.

Materials and methods

Zero-order phase and frequency shift of a MR spectrum are linked respectively to zero-order and first-order phase variations in the corresponding free induction decay (FID) signal. One of the simplest ways to remove the phase component of a signal is to calculate the modulus of this signal: this approach is the basis of the correction technique presented here.

Results

We show that selecting the modulus of the FID allows, under certain conditions that are detailed, to automatically phase correct and frequency align the spectra. This correction technique can be for example applied to the summation of signals acquired from combined phased array coils, to phase coherent averaging and to B 0 shift correction.

Conclusion

We demonstrate that working on the modulus of the FID signal is a simple and efficient way to both phase correct and frequency align MR spectra automatically. This approach is particularly well suited to brain proton MR spectroscopy.  相似文献   

5.

Object

Knowledge of the total circulating blood volume (TCBV) is essential for the treatment of a variety of medical conditions and blood disorders. To date, blood volume analysis is rarely carried out due to the disadvantages of available methods. Our aim was to develop a widely available, simple, fast, yet accurate method for the determination of the total circulating blood volume.

Materials and methods

Magnetic resonance (MR) is a well-established, non-invasive technique. In this article, we present a method that uses MR contrast agents for the determination of the blood volume. The dependence of MR relaxation times on the concentration of MR contrast agents allows the calculation of the volume the contrast agent has been diluted in.

Results

In phantom and in vivo experiments we could demonstrate that TCBV can be determined with high accuracy and precision.

Conclusion

This work introduces a novel method for the determination of the total circulating blood volume using magnetic resonance contrast agents as tracers.  相似文献   

6.

Objective

To analyze the streak artifacts in a gradient-echo echo planar imaging (GE-EPI) sequence and to propose a correction method for the Nyquist ghost artifacts that does not cause streak artifacts in the GE-EPI imaging.

Materials and methods

Several GE-EPI imaging experiments with various reference scans, using both GE-EPI and SE-EPI scan data, were performed to analyze the streak artifacts and to investigate the spin dephasing phenomena of the GE-EPI reference scan. In addition, the analysis based on the spin dephasing was undertaken in order to demonstrate that the SE-EPI reference data can be used for the correction of the GE-EPI main scan data.

Results

The experimental results confirmed that the improvement of the reference data using either signal averaging or a large flip angle cannot guarantee perfect correction of the streak artifact if the noise is not completely removed. Due to the main field inhomogeneity, the spins of the GE-EPI reference data were dephased in multiple echo signals. The proposed correction method, which uses a SE-EPI reference scan for the GE-EPI images, eliminates the N/2 ghost artifacts without producing streak artifacts.

Conclusion

It is believed that the proposed phase error correction scheme can improve the EPI performance in high field MRIs with higher magnetic field inhomogeneities.  相似文献   

7.

Objective

Recent years have seen an increased interest in combining MRI thermometry with devices capable of destroying malignancies by heat ablation. Expected from the MR protocols are accurate and fast thermal characterizations, providing real time feedback on restricted tissue volumes and/or rapidly moving organs like liver. This article explores the potential advantages of relying on spatiotemporally encoded (SPEN) sequences for retrieving real-time thermometric images based on the water’s proton resonance frequency (PRF) shifts.

Materials and methods

Hybrid spatiotemporal/k-space encoding single-scan MRI experiments were implemented on animal and human scanners, and their abilities to deliver single- and multi-slice real-time thermometric measurements based on PRF-derived phase maps in phantoms and in vivo, were compared against echo planar imaging (EPI) and gradient-echo counterparts.

Results

Under comparable acquisition conditions, SPEN exhibited advantages vis-à-vis EPI in terms of dealing with inhomogeneous magnetic field distortions, with shifts arising due to changes in the central frequency offsets, with PRF distributions, and for zooming into restricted fields-of-view without special pulse sequence provisions.

Conclusion

This work confirms the ability of SPEN sequences, particularly when implemented under fully-refocused conditions, to exploit their built-in robustness to shift- and field-derived inhomogeneities for monitoring thermal changes in real-time under in vitro and in vivo conditions.  相似文献   

8.
The homogeneity and stability of the static magnetic field are of paramount importance to the accuracy of MR procedures that are sensitive to phase errors and magnetic field inhomogeneity. It is shown that intense gradient utilization in clinical horizontal-bore superconducting MR scanners of three different vendors results in main magnetic fields that vary on a long time scale both spatially and temporally by amounts of order 0.8–2.5 ppm. The observed spatial changes have linear and quadratic variations that are strongest along the z direction. It is shown that the effect of such variations is of sufficient magnitude to completely obfuscate thermal phase shifts measured by proton-resonance frequency-shift MR thermometry and certainly affect accuracy. In addition, field variations cause signal loss and line-broadening in MR spectroscopy, as exemplified by a fourfold line-broadening of metabolites over the course of a 45 min human brain study. The field variations are consistent with resistive heating of the magnet structures. It is concluded that correction strategies are required to compensate for these spatial and temporal field drifts for phase-sensitive MR protocols. It is demonstrated that serial field mapping and phased difference imaging correction protocols can substantially compensate for the drift effects observed in the MR thermometry and spectroscopy experiments.  相似文献   

9.

Object

In vivo magnetic resonance imaging (MRI) of iron-labeled pancreatic islets (PIs) transplanted into the liver is still challenging in humans. The aim of this study was to develop and evaluate a double contrast method for the detection of PIs labeled with superparamagnetic iron oxide (SPIO) nanoparticles.

Materials and methods

A double-echo three-dimensional (3D) spoiled gradient echo sequence was adapted to yield a sub-millisecond first echo time using variable echo times and highly asymmetric Cartesian readout. Positive contrast was achieved by conventional and relative image subtraction. Experiments for cell detection efficiency were performed in vitro on gelatin phantoms, in vivo on a Lewis rat and on a patient 6 months after PI transplantation.

Results

It was demonstrated that the proposed method can be used for the detection of transplanted PIs with positive contrast in vitro and in vivo. For all experiments, relative subtraction yielded comparable and in some cases better contrast than conventional subtraction. For the first time, positive contrast imaging of transplanted human PIs was performed in vivo in patients.

Conclusion

The proposed method allows 3D data acquisition within a single breath-hold and yields enhanced contrast-to-noise ratios of transplanted SPIO labeled pancreatic islets relative to negative contrast images, therefore providing improved identification.  相似文献   

10.

Object

The ability to generate reference signals is of great benefit for quantitation of the magnetic resonance (MR) signal. The aim of the present study was to implement a dedicated experimental set-up to generate MR images of virtual phantoms.

Materials and methods

Virtual phantoms of a given shape and signal intensity were designed and the k-space representation was generated. A waveform generator converted the k-space lines into a radiofrequency (RF) signal that was transmitted to the MR scanner bore by a dedicated RF coil. The k-space lines of the virtual phantom were played line-by-line in synchronization with the magnetic resonance imaging data acquisition.

Results

Virtual phantoms of complex patterns were reproduced well in MR images without the presence of artifacts. Time-series measurements showed a coefficient of variation below 1 % for the signal intensity of the virtual phantoms. An excellent linearity (coefficient of determination r 2 = 0.997 as assessed by linear regression) was observed in the signal intensity of virtual phantoms.

Conclusion

Virtual phantoms represent an attractive alternative to physical phantoms for providing a reference signal. MR images of virtual phantoms were here generated using a stand-alone, independent unit that can be employed with MR scanners from different vendors.  相似文献   

11.
12.

Object

The EU directive on safety requirements (2004/40/EC) limits the exposure to time varying magnetic fields to dB /dt = 200 mT/s. This action value is not clearly defined as it considers only the temporal change of the magnitude of ${\vec {B}}$ . Thus, only the translational motion in the magnet??s fringe field is considered and rotations are neglected.

Materials and methods

A magnetic field probe was constructed to simultaneously record the magnetic flux density ${\vec{B}}$ (x, y, z) with a 3-axis Hall sensor and the induced voltage due to movements with a set of three orthogonal coils. Voltages were converted into time-varying magnetic flux d ??(x, y, z)/dt serving as an exposition parameter for both translations and rotations. To separate the two types of motion, d B/dt was additionally calculated on the basis of the Hall sensor??s data. The calibrated probe was attached to the forehead of 8 healthcare workers and 17 MR physicists, and ${\vec {B}}$ and d??/dt were recorded during standard operating procedures at three different MR systems up to 7 T.

Results

The maximum percentage of the translational motion referring the data including both translations and rotations amounts to 32%. During volunteer measurements, maximum exposure values of d??/dt = 21 mWb/s, dB/dt = 1.40 T/s and ${\left| {\vec {B}}\right|= 2.75}$ Twere found.

Conclusion

The findings in this work indicate that both translations and rotations in the vicinity of an MR system should be taken into account, and that a single regulatory action level might not be sufficient.  相似文献   

13.

Object

Delta relaxation enhanced magnetic resonance (dreMR) is a new imaging technique based on the idea of cycling the magnetic field B 0 during an imaging sequence. The method determines the field dependency of the relaxation rate (relaxation dispersion dR 1/dB). This quantity is of particular interest in contrast agent imaging because the parameter can be used to determine contrast agent concentrations and increases the ability to localize the contrast agent.

Materials and methods

In this paper dreMR imaging was implemented on a clinical 1.5?T MR scanner combining conventional MR imaging with fast field-cycling. Two improvements to dreMR theory are presented describing the quantification of contrast agent concentrations from dreMR data and a correction for field-cycling with finite ramp times.

Results

Experiments demonstrate the use of the extended theory and show the measurement of contrast agent concentrations with the dreMR method. A second experiment performs localization of a contrast agent with a significant improvement in comparison to conventional imaging.

Conclusion

dreMR imaging has been extended by a method to quantify contrast agent concentrations and improved for field-cycling with finite ramp times. Robust localization of contrast agents using dreMR imaging has been performed in a sample where conventional imaging delivers inconclusive results.  相似文献   

14.
In vivo chlorine and sodium MRI of rat brain at 21.1 T   总被引:1,自引:1,他引:0  

Object

MR imaging of low-gamma nuclei at the ultrahigh magnetic field of 21.1 T provides a new opportunity for understanding a variety of biological processes. Among these, chlorine and sodium are attracting attention for their involvement in brain function and cancer development.

Materials and methods

MRI of 35Cl and 23Na were performed and relaxation times were measured in vivo in normal rat (n = 3) and in rat with glioma (n = 3) at 21.1 T. The concentrations of both nuclei were evaluated using the center-out back-projection method.

Results

T 1 relaxation curve of chlorine in normal rat head was fitted by bi-exponential function (T 1a = 4.8 ms (0.7) T 1b = 24.4 ± 7 ms (0.3) and compared with sodium (T 1 = 41.4 ms). Free induction decays (FID) of chlorine and sodium in vivo were bi-exponential with similar rapidly decaying components of $ T_{{2{\text{a}}}}^{*} = 0.4 $  ms and $ T_{{2{\text{a}}}}^{*} = 0.53 $  ms, respectively. Effects of small acquisition matrix and bi-exponential FIDs were assessed for quantification of chlorine (33.2 mM) and sodium (44.4 mM) in rat brain.

Conclusion

The study modeled a dramatic effect of the bi-exponential decay on MRI results. The revealed increased chlorine concentration in glioma (~1.5 times) relative to a normal brain correlates with the hypothesis asserting the importance of chlorine for tumor progression.  相似文献   

15.

Object

To evaluate the feasibility of positron emission tomography/magnetic resonance imaging (PET/MR) with 18fluoro-2-deoxyglucose (FDG) for therapy response evaluation of malignant lymphoma.

Materials and methods

Nine patients with malignant lymphoma who underwent FDG-PET/MR before and after chemotherapy were included in this retrospective study. Average time between the two scans was 70 days. The scans were evaluated independently by two nuclear medicine physicians. The Ann Arbor classification was used to describe lymphoma stage. Furthermore, the readers also rated PET image quality using a five point scale. Weighted kappa (κ) was used to calculate interrater agreement.

Results

The initial scan showed foci of increased FDG uptake in all patients, with Ann Arbor stage varying between I and IV. In the follow-up examination, all but one patient showed complete response to chemotherapy. PET image quality was rated as very good or excellent for all scans. Interrater agreement was excellent regarding Ann Arbor stage (κ = 0.97) and good regarding image quality (κ = 0.41).

Conclusion

PET/MR shows promising initial results for therapy response evaluation in lymphoma patients.  相似文献   

16.

Object

The specific absorption rate (SAR) can be determined from radiofrequency transmit fields measured via magnetic resonance imaging.

Materials and methods

The proposed method estimates the SAR solely from the complex transmit field (B 1 + ) by taking into account the particular properties of the electromagnetic field generated by an 8-channel transmit array. It is further based on an iterative consistency check between the measured B 1 + magnitude and an appropriate field estimate fulfilling Maxwell’s equations. For testing the method, simulations and phantom experiments were performed for a multi-transmit array at 3T using a cylindrical phantom.

Results

The method’s robustness with respect to the assumptions made about electric tissue properties as well as its stability under different initial conditions regarding the signal phase was shown. A high sensitivity to signal noise was found. Robust reconstruction results were achieved including information from more than two transmit elements. The validity of the experimental results was confirmed by a qualitative comparison to simulated electromagnetic fields.

Conclusions

The method allows the determination of the SAR as well as the transmit phase of the individual channels of a multi-transmit array. With additional B0 inhomogeneity measurements, a reconstruction of the receive phase is feasible independent of the receive coil type in use.  相似文献   

17.
Objectives: To characterize artifacts and imaging problems in the presence of conductive grounding pads for RF ablation therapy as well as potential heating problems due to induction of eddy currents in the pads. Strategies for avoidance of those problems are developed. Materials and methods: Underlying principles of interactions between grounding pads and MR imaging are reported. Influential parameters, e.g., orientation in relation to the magnetic field, shape of the grounding pad, sequence type (spin-echo versus gradient echo) and magnetic field strength (0.2 T, 1.5 T, 3 T) were varied in systematic phantom studies. Heating effects due to induced eddy currents were estimated theoretically and measured by infrared imaging in an adapted set-up. Results: MR imaging artifacts are markedly dependent on the orientation and geometrical shape of the grounding pads. Visible signal extinction artifacts were more pronounced using spin-echo techniques than in gradient echo images and increased for higher field strengths. Suitable incisions in the grounding pad reduced eddy currents markedly and minimized image artifacts. Heating problems due to induced eddy currents by the RF transmitted for MR imaging were excluded by phantom measurements. Conclusions: Suitable positioning of the grounding pads and adaptation of their geometry provide clearly reduced artifacts in MR imaging.  相似文献   

18.

Object

The aim of this study was to evaluate MR-based attenuation correction of PET emission data of the head, based on a previously described technique that calculates substitute CT (sCT) images from a set of MR images.

Materials and methods

Images from eight patients, examined with 18F-FLT PET/CT and MRI, were included. sCT images were calculated and co-registered to the corresponding CT images, and transferred to the PET/CT scanner for reconstruction. The new reconstructions were then compared with the originals. The effect of replacing bone with soft tissue in the sCT-images was also evaluated.

Results

The average relative difference between the sCT-corrected PET images and the CT-corrected PET images was 1.6 % for the head and 1.9 % for the brain. The average standard deviations of the relative differences within the head were relatively high, at 13.2 %, primarily because of large differences in the nasal septa region. For the brain, the average standard deviation was lower, 4.1 %. The global average difference in the head when replacing bone with soft tissue was 11 %.

Conclusion

The method presented here has a high rate of accuracy, but high-precision quantitative imaging of the nasal septa region is not possible at the moment.  相似文献   

19.
A rigorous reformulation of the magnetic resonance (MR) image formulation model (IFM) can use the integrally cumulative nature of MRI phase shifts for encoding and of time-of-flight travel corrections for magnitude. This approach characterizes each independent gradient element by its cumulant waveforms,K N (t), instead of by particular time expansion in gradient moments. The lowest-order cumulant gradient that gives a simple monopolar waveform governs all resulting phase-encoding properties. Each gradient element specifically encodes one and only one motion-order variable. Phase sensitizations to higher order do not exist; they are mathematical psuedophasings. Magnetization isochromats may have arbitrarily complicated velocity history,V(t), appearing in both time-of-flight and motion phase-shift formulas. The subject's intravoxel motion subdistributions each automatically reference the correct mean time of encoding action and its encoding duration. This formulation yields very simple and generalizable IFM expressions for MRI acquired data, with no theoretical confusion regarding higher-order phase shifts and nonphased time-of-flight effects.  相似文献   

20.

Object

The sequence combining DQF (double quantum filtering) with magnetisation transfer (DQF-MT) was tested as an alternative to the DQF sequence for characterising tendon and muscle by MR imaging.

Materials and methods

DQF-MT images of tendon–muscle phantoms were obtained at 4.7 T using ultra-short time to echo (UTE) methods in order to alleviate the loss of SNR due to the short T2 of the tissues. Two different sampling schemes of the k-space, Cartesian or radial, were employed. In vivo images of the human ankle on a clinical 1.5 T scanner are also presented. Parameters providing optimal tendon signal as well as optimal contrast between this tissue and muscle were determined.

Results

Two sets of parameters resulting in different contrasts between the tissues were found. For the first set (short creation time τ = 10 μs and magnetisation exchange time t LM = 100 ms), DQF-MT signals in muscle and tendon were detected, with that of the tendon being the larger one. For the second set (long creation time τ = 750 μs and magnetisation exchange time 10 μs < t LM < 100 ms), the DQF-MT signal was detected only in the tendon, and the decay of the double quantum coherence was slower than that observed for the first one, which allowed us to acquire DQF-MT MR images on a clinical 1.5 T MR scanner with minimal software interventions. In favourable conditions, the DQF-MT signal in the tendon could represent up to 10 % of the single-quantum signal.

Conclusion

Dipolar interaction within macromolecules such as collagen and myosin is at the origin of the DQF-MT signal observed in the first parameter set. This should enable the detection of muscle fibrosis.  相似文献   