首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This paper presents experimental evaluations for variation in the efficiency of energy extracted from a photovoltaic (PV) module (under non-linear loading) incorporated with an incremental conductance(IC) maximum power point tracking (MPPT) algorithm. The focus is on the evaluation of the PV panel under non-linear loading conditions using the experimental installation of a 100Wp photovoltaic array connected to a DC–DC converter and a KVA inverter feeding a non-linear load. Under the conditions of non-linear loading, both the simulation and experiment show that the MPPT technique fails to attain maximum power point due to the presence of ripples in the current leading eventually to a reduction in efficiency. In this paper, panel current is taken as a function of load impedance in the MPPT algorithm to eradicate power variation, as load impedance varies with supply voltage under non-linear conditions. The system is simulated for different non-linear loads using MATLAB-Simulink. A TMDSSOLAREXPKIT was used for MPPT control. In case 2, the inverter is connected to a single phase grid. When a voltage swell occurs in the grid, PV power drops. This power loss is reduced using the proposed MPPT method. The results of simulations and experimental measurements and cost efficiency calculations are presented.  相似文献   

2.
This paper presents the control of a three-level Neutral Point Clamped (NPC) voltage source inverter for grid connected photovoltaic (PV) systems. The control method used is the Extended Direct Power Control (EDPC), which is a generic approach for Direct Power Control (DPC) of multilevel inverters based on geometrical considerations. Maximum Power Point Tracking (MPPT) algorithms, that allow maximal power conversion into the grid, have been included. These methods are capable of extracting maximum power from each of the independent PV arrays connected to each DC link voltage level. The first one is a conventional MPPT which outputs DC link voltage references to EDPC. The second one is based on DPC concept. This new MPPT outputs power increment references to EDPC, thus avoiding the use of a DC link voltage regulator. The whole control system has been tested on a three-level NPC voltage source inverter connected to the grid and results confirm the validity of the method.  相似文献   

3.
This paper presents a single stage transformer-less grid-connected solar photovoltaic (PV) system with an active and reactive power control. In the absence of active input power, the grid-tied voltage source converter (VSC) is operated in a reactive power generation mode, which powers the control circuitry, and maintains a regulated DC voltage to the VSC. A data-based maximum power point tracking (MPPT) control scheme which performs power quality control at a maximum power by reducing the total harmonic distortion (THD) in grid injected current as per IEEE-519/1547 standards is implemented. A proportional-integral (PI) controller based dynamic voltage restorer (DVR) control scheme is implemented which controls the grid side converter during single-phase to ground fault. The analysis includes the grid current THD along with the corresponding variation of the active and reactive power during the fault condition. The MPPT tracks the actual variable DC link voltage while deriving the maximum power from the solar PV array, and maintains the DC link voltage constant by changing the modulation index of the VSC. Simulation results using Matlab/Simulink are presented to demonstrate the feasibility and validations of the proposed novel MPPT and DVR control systems under different environmental conditions.  相似文献   

4.
Dynamic voltage restorer (DVR) is used to protect sensitive loads from voltage disturbances of the distribution generation (DG) system. In this paper, a new control approach for the 200 kW solar photovoltaic grid connected system with perturb and observe maximum power point tracking (MPPT) technique is implemented. Power quality improvement with comparison is conducted during fault with proportional integral (PI) and artificial intelligence-based fuzzy logic controlled DVR. MPPT tracks the actual variable DC link voltage while deriving the maximum power from a photovoltaic array and maintains DC link voltage constant by changing modulation index of the converter. Simulation results during fault show that the fuzzy logic based DVR scheme demonstrates simultaneous exchange of active and reactive power with less total harmonic distortion (THD) present in voltage source converter (VSC) current and grid current with fast tracking of optimum operating point at unity power factor. Standards (IEEE-519/1547), stipulates that the current with THD greater than 5% cannot be injected into the grid by any distributed generation source. Simulation results and validations of MPPT technique and operation of fuzzy logic controlled DVR demonstrate the effectiveness of the proposed control schemes.  相似文献   

5.
This paper presents a transformer-less single-stage grid-connected solar photovoltaic (PV) system with active reactive power control. In the absence of active input power, grid-tied voltage source converter (VSC) is operated in the reactive power generation mode, which powers control circuitry and maintains regulated DC voltage. Control scheme has been implemented so that the grid-connected converter continuously serves local load. A data-based maximum power point tracking (MPPT) has been implemented at maximum power which performs power quality control by reducing total harmonic distortion (THD) in grid-injected current under varying environmental conditions. Standards (IEEE-519/1547) stipulates that current with THD greater than 5% cannot be injected into the grid by any distributed generation (DG) source. MPPT tracks actual variable DC link voltage while deriving maximum power from PV array and maintains DC link voltage constant by changing the converter modulation index. Simulation results with the PV model and MPPT technique validations demonstrate effectiveness of the proposed system.  相似文献   

6.
In this paper, sliding mode control (SMC) – direct power controller (DPC) based active and reactive power controller for three-phase grid-tied photovoltaic (PV) system is proposed. The proposed system consists of two main controllers: the DC/DC boost converter to track the possible maximum power from the PV panels and the grid-tied three-phase inverter. The Perturb and Observe (P&O) algorithm is used to transfer the maximum power from the PV panels. Control of the active and reactive powers is performed using the SMC-DPC strategy without any rotating coordinate transformations or phase angle tracking of the grid voltage. In addition, extra current control cycles are not used to simplify the system design and to increase transient performance. The fixed switching frequency is obtained by using space vector modulation (SVM). The proposed system provides very good results both in transient and steady states with the simple algorithms of P&O and SMC-DPC methods. Moreover, the results are evaluated by comparing the SMC-DPC method developed for MPPT and the traditional PI control method. The proposed controller method is achieved with TMS320F28335 DSP processor and the system is experimentally tested for 12 kW PV generation systems.  相似文献   

7.
The resiliency of a standalone microgrid is of considerable issue because the available regulation measures and capabilities are limited. Given this background, this paper presented a new mathematical model for a detailed photovoltaic (PV) module and the application of new control techniques for efficient energy extraction. The PV module employs a single-stage conversion method to integrate it with the utility grid. For extraction the maximum power from PV and integrate it to power grid, a three-phase voltage source converter is used. For obtaining the maximum power at a particular irradiance a maximum power point tracking (MPPT) scheme is used. The fuzzy logic control and adaptive network-based fuzzy inference system are proposed for direct current (DC) link voltage control. The proposed model and control scheme are validated through a comparison with the standard power-voltage and current–voltage charts for a PV module. Simulation results demonstrate that the system stability can be maintained with the power grid and in the island mode, in contrast with the MPPT.  相似文献   

8.
The integration of significant amounts of renewable-storage hybrid power generation systems to the electric grid poses a unique set of challenges to utilities and system operators. This article deals with the designing methodology of an intelligent control based grid-connected a hybrid system composed of renewable energy source (RES) and storage system (SS). RES is a photovoltaic (PV) source and SS is a process of hydrogen transformation system (H2TS) which composed of alkaline water electrolysis (AWE) for decomposition water by using the PV power, a tank used for gas storage and a proton exchange membrane (PEM) fuel cell (FC) to transform the H2 to the electrical energy. The interconnection of the grid with the power generation system (PGS) is ensured through using a DC/AC hysteresis converter and it can synchronize current with the grid voltage among an independent control of active (P) and reactive (Q) power through a possibility of the Q compensation. In the proposed system, three algorithms are applied; two used inside generation and the third is used inside the grid. Perturb and observe (P&O) maximum power point tracking (MPPT) control algorithm always finds optimal power in the PV generator. A simple cascade controls loop of DC-DC boost converter and operate the FC generator to ensure maximum power and to regulate the DC Bus voltage. In addition, adaptive fuzzy logic control (FLC) unit is developed to control the DC/AC inverter, with adopting an off-line optimization based on genetic algorithms (GAs) applauded for tune different issues as scaling factors of the FLC and PIDs gains of the PV and the H2TS control loops. Simulated results prove a big success of the proposed controls of the grid connected the hybrid PV-H2TS with good performance.  相似文献   

9.
This paper deals with a real time implementation of a fuzzy logic-based power management of a small scale generation hybrid power system. The system consists of a photovoltaic array and a fuel cell stack, supported by a single-phase grid that supplies a stand-alone AC load. The proposed supervisory algorithm guaranties the system to switch smart between two operation modes, according to the load demand, the gas level and the PV availability. Obviously, the PV side DC–DC converter is controlled to track permanently the maximum power point by using a fuzzy logic MPPT method; whereas, the fuel cell stack and the grid converters are tuned to cover the remaining power, or alternatively, injecting the exceeding power to the utility. Besides, to feed the AC load with a pure sine wave, a Back stepping algorithm is proposed to control the front-end single-phase inverter. To test the effectiveness of the proposed algorithms, experimental results obtained with a given load profile are presented and commented.  相似文献   

10.
In this paper, a simple control strategy for an optimal extraction of output power from grid connected variable speed wind energy conversion system (WECS) is presented. The system consists of a variable speed wind turbine coupled to a permanent magnet synchronous generator (PMSG) through a gear box, a diode bridge rectifier, a dc-to-dc boost converter and a current controlled voltage source inverter. The maximum power point tracker (MPPT) extracts maximum power from the wind turbine from cut-in to rated wind velocity by sensing only dc link power. The MPPT step and search algorithm in addition to the DC–DC and DC–AC converters PWM controllers are simulated using MATLAB-SIMULINK software. The obtained simulation results show that the objectives of extracting maximum power from the wind and delivering it correctly to the grid are reached.  相似文献   

11.
In this paper a grid connected photovoltaic (PV) system is presented. The grid integration of the PV system is carried out via a three phase three level neutral point clamped (NPC) inverter. To control the inverter a modified version of voltage oriented control (VOC) method and the space vector pulse width modulation (SVPWM) technique have been applied. With the proposed modification the PV system operates as a shunt active power filter (SAPF), a reactive power compensator, and a load’s current balancer simultaneously. In this way the PV system operates more efficiently compared to the conventional PV systems and offers ancillary services to electric power system. The effectiveness of the proposed control scheme is established through simulation results with Matlab/Simulink in steady state and transient response of the electric power distribution system.  相似文献   

12.
Grid connected photovoltaic (PV) system encounters different types of abnormalities during grid faults; the grid side inverter is subjected to three serious problems which are excessive DC link voltage, high AC currents and loss of grid-voltage synchronization. This high DC link voltage may damage the inverter. Also, the voltage sags will force the PV system to be disconnected from the grid according to grid code. This paper presents a novel control strategy of the two-stage three-phase PV system to improve the Low-Voltage Ride-Through (LVRT) capability according to the grid connection requirement. The non-linear control technique using Improved Particle Swarm Optimization (IPSO) of a PV system connected to the grid through an isolated high frequency DC–DC full bridge converter and a three-phase three level neutral point clamped DC-AC converter (3LNPC2) with output power control under severe faults of grid voltage. The paper, also discusses the transient behavior and the performance limit for LVRT by using a DC-Chopper circuit. The model has been implemented in MATLAB/SIMULINK. The proposed control succeeded to track MPP, achieved LVRT requirements and improving the quality of DC link voltage. The paper shows superiority of IPSO than Incremental Conductance (IC) method during MPPT mode of PV system.  相似文献   

13.
This paper presents implementation of particle swarm optimization (PSO) algorithm as a C-Mex S-function. The algorithm is used to optimize a 9-rule fuzzy logic controller (FLC) for maximum power point tracking (MPPT) in a grid-connected photovoltaic (PV) inverter. The FLC generates DC bus voltage reference for MPPT. A digital PI current control scheme in rotating dq-reference frame is used to regulate the DC bus voltage and reactive power. The proposed technique simplifies optimal controller design and ensures fast simulation speeds due to seamless integration with the simulation platform. Validity of the proposed method was verified using co-simulation in PSIM and MATLAB/Simulink. Simulation results show that the optimized FLC gives a better performance compared to fixed-step MPPT.  相似文献   

14.
In photovoltaic (PV) applications, a maximum power point tracking (MPPT) module is necessary to extract the whole energy that the PV module can generate depending on the instantaneous conditions of the PV system. A PV module is obtained by connecting a number of solar cells in series and parallel, which causes voltage and current to increase at module terminations. The present work is based on a three-phase grid-connected inverter designed for a 100 kW PV power plant that uses an MPPT scheme based on fuzzy logic controllers. The whole system presented is simulated in MATLAB. The fuzzy logic-based MPPT controllers show accurate and fast responses and are integrated into the inverter, so that the there is no requirement for a dc–dc converter. The inverter allows full control of reactive power.  相似文献   

15.
High Altitude Wind Power (HAWP) generating system provides clean energy at low cost and high capacity factor due to reduced size of the turbine and high speed streamlined wind at high altitude. An air-borne wind turbine (AWT) at high altitude extracts kinetic energy from wind using buoyancy provided by the blimp/aerostat. The generated electrical power is then transmitted to the ground based station (without any power conditioning) using the transmission lines (tether). The power conversion system (PCS) for harnessing HAWP is proposed in this paper. The proposed PCS consists of a three-level neutral point clamped (NPC) rectifier, a three-level NPC DC–DC converter followed by a two-level inverter. Modelling, design and control of the PCS are presented and discussed. The PCS provides generation side maximum power-point tracking (MPPT) using sensorless optimal torque control technique. The DC–DC converter provides electrical isolation as well as voltage step-down functions. A modified proportional resonant (PR) control which can selectively eliminate lower order current harmonics of the grid-connected inverter is also presented. The proposed control scheme of the PCS is evaluated through simulation studies using software programs like PSIM and MATLAB. A scaled-down 1 kW laboratory prototype of the complete PCS is designed, built and tested. The experimental test results obtained validate the proposed control scheme for efficient power generation from high altitude wind and interface to the grid/load.  相似文献   

16.
针对传统的Z源逆变电路控制方式中需要独立分析升压电路控制因子和并网电路控制因子的问题,先在典型的Z源全桥逆变电路的拓扑结构中实现单桥臂上下管的直通相位控制方式下的开关时序,进而分析了Z源逆变电路的5种模态的工作原理,提出了一种适用于单相光伏逆变系统的Z源逆变电路直通控制方式,就是利用能量传递和傅里叶算法在直通零矢量和输出逆变电压之间建立直接联系。以一台3kW光伏并网逆变样机的测试结果表明,样机PV电压稳定,并网电压电流相位在50%输出功率下基本一致,其谐波含量和功率因数符合要求;同时,还具备一定的过压、欠压动态保护特性,反应时间迅速。结果表明,Z源逆变电路及其直通控制策略在光伏并网系统中的应用效果较好。  相似文献   

17.
This paper presents modeling and control of a photovoltaic generator (PVG) connected to the grid. The parameters of the PVG have been identified in previous work (series and parallel resistance, reverse saturation current and thermal voltage) using Newton-Raphston and the gradient algorithm. The electrical energy from a PVG is transferred to the grid via two static converters (DC/DC and DC/AC). The objective of the proposed control strategy is to maximize energy captured from the PVG. The adapted control law for extracting maximum power from the PVG is based on the incremental conductance algorithm. The developed algorithm has the capability of searching the maximum photovoltaic power under variable irradiation and temperature. To control the DC/AC inverter, an intelligent system based on two structures is constructed: a current source control structure and a voltage source control structure. The system has been validated by numerical simulation using data obtained from the PVG installed in the laboratory research (INSAT, Tunisia).  相似文献   

18.
The overall efficiency of photovoltaic (PV) systems connected to the grid depends on the efficiency of direct current (DC) of the solar modules to alternate current (AC) inverter conversion. The requirements for inverter connection include: maximum power point, high efficiency, control power injected into the grid, high power factor and low total harmonic distortion of the currents injected into the grid. An approach to power factor control and reactive power regulation for PV systems connected to the grid using field programmable gate array (FPGA) is proposed. According to the grid demands; both the injected active and reactive powers are controlled.In this paper, a new digital control strategy for a single-phase inverter is carried out. This control strategy is based on the phase shift between the inverter output voltage and the grid voltage, and the digital sinusoidal pulse width modulation (DSPWM) patterns, in order to control the power factor for a wide range of the inverter output current and consequently the control and the regulation of the reactive power will be achieved. The advantage of the proposed control strategy is its implementation around simple digital circuits.In this work, a simulation study of this strategy has been realized using Matlab/Simulink and PSIM. In order to validate its performance, this control has been implemented in a FPGA. Experimental tests have been carried out demonstrating the viability of this control in order to control the power factor and the injected power into the grid.  相似文献   

19.
This paper proposes a comprehensive MPPT method by which extraction of maximum power from wind turbine and its subsequent transfer through various power stages and final delivery to the connected grid are realized. In the proposed system, the operation of the wind turbine at its maximum efficiency point is maintained by control of grid‐tied inverter such that the shaft speed of the generator is set to result the desired optimum tip speed ratio of the turbine. The proposed comprehensive MPPT estimates the required DC link voltage for each wind speed using a unified system model, uses a loss factor to account for the system losses, and then controls the inverter to push the WT extracted maximum power into the grid. The comprehensive MPPT is developed and is validated in MATLAB/Simulink platform in a wide range of operating wind speed. The results ascertain that the wind turbine is made to operate at its maximum efficiency point for all wind speeds below the rated one.  相似文献   

20.
To increase the output efficiency of a photovoltaic (PV) system, it is important to apply an efficient maximum power point tracking (MPPT) technique. This paper describes the analysis, the design and the experimental implementation of the tracking methods for a stand-alone PV system, using two approaches. The first one is the constant voltage (CV) MPPT method based on the optimum voltage, which was deduced experimentally, and considered as a reference value to extract the optimum power. The second one is the increment conductance (Inc-Cond) MPPT method based on the calculation of the power derivative extracted by the installation. The output controller can adjust the duty ratio to the optimum value. This optimum duty ratio is the input of a DC/DC boost converter which feeds a set of Moto-pump via a DC/AC inverter. This paper presents the details of the two approaches implemented, based on the system performance characteristics. Contributions are made in several aspects of the system, including converter design, system simulation, controller programming, and experimental setup. The MPPT control algorithms implemented extract the maximum power point (MPP), with satisfactory performance and without steady-state oscillation. MATLAB/Simulink and dSpace DS1104 are used to conduct studies and implement algorithms. The two proposed methods have been validated by implementing the performance of the PV pumping systems installed on the roof of the research laboratory in INSAT Tunisia. Experimental results verify the feasibility and the improved functionality of the system.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号