首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Ambient daytime and nighttime PM10 and PM2.5 samples were collected in parallel at a kerbside in Dar es Salaam in August and September 2005 (dry season) and in April and May 2006 (wet season). All samples were analyzed for the particulate matter mass, for organic, elemental, and total carbon (OC, EC, and TC), and for water-soluble OC (WSOC). The average PM10 and PM2.5 mass concentrations and associated standard deviations were 76 ± 32 µg/m3 and 26 ± 7 µg/m3 for the 2005 dry season and 52 ± 27 µg/m3 and 19 ± 10 µg/m3 for the 2006 wet season campaign. On average, TC accounted for 29% of the PM10 mass and 49% of the PM2.5 mass for the 2005 dry season campaign and the corresponding values for the 2006 wet season campaign were 35% and 59%. There was little difference between the two campaigns for the WSOC/OC ratios with the PM2.5 fraction having higher ratios than the PM10 fraction during each campaign. Also for EC/TC higher ratios were noted in PM2.5 than in PM10, but the ratios were substantially larger in the 2006 wet season than in the 2005 dry season. The large EC/TC ratios (means 0.22-0.38) reflect the substantial impact from traffic at Dar es Salaam, as was also apparent from the clear diurnal variation in OC levels, with higher values during the day. A simple source apportionment approach was used to apportion the OC to traffic and charcoal burning. On average, 70% of the PM10 OC was attributed to traffic and 30% to charcoal burning in both campaigns. A definite explanation for the substantially larger EC/TC ratios in the 2006 campaign as compared to the 2005 campaign is not available.  相似文献   

2.
Aerosol background at two remote CAWNET sites in western China   总被引:4,自引:0,他引:4  
The frequency distributions and some statistical features of background aerosol concentrations were investigated at two remote China Atmosphere Watch Network (CAWNET) stations. The estimated elemental carbon (EC) background at Akdala (AKD) in the mid-latitudes of northwestern China (~ 0.15 μg m− 3) was only half of that at Zhuzhang (ZUZ) in low-latitude southwestern China (~ 0.30 μg m− 3). The contributions of EC to the aerosol mass also differed between sites: EC contributed 3.5% of the PM10 mass at AKD versus 5.1% at ZUZ. Large percentages of the total organic carbon (OC) apparently were secondary organic carbon (SOC); SOC/OC averaged 81% at ZUZ and 68% at AKD. The OC/EC ratios in PM10 (ZUZ: 11.9, AKD: 12.2) were comparable with other global background sites, and the OC/EC ratios were used to distinguish polluted periods from background conditions. The SO42, NH4+ and soil dust loadings at AKD were higher and more variable than at ZUZ, probably due to impacts of pollution from Russia and soil dust from the Gobi and adjacent deserts. In contrast to ZUZ, where the influences from pollution were weaker, the real-time PM10 mass concentrations at AKD were strongly skew right and the arithmetic mean concentrations of the aerosol populations were higher than their medians. Differences in the aerosol backgrounds between the sites need to be considered when evaluating the aerosol's regional climate effects.  相似文献   

3.
In this paper, the chemical characterization of PM10 and PM2.5 mass concentrations emitted by heterogeneous traffic in Chennai city during monsoon, winter and summer seasons were analysed. The 24-h averages of PM10 and PM2.5 mass concentrations, showed higher concentrations during the winter season (PM10 = 98 μg/m3; PM2.5 = 74 μg/m3) followed by the monsoon (PM10 = 87 μg/m3; PM2.5 = 56 μg/m3) and summer (PM10 = 77 μg/m3; PM2.5 = 67 μg/m3) seasons. The assessment of 24-h average PM10 and PM2.5 concentrations was indicated as violation of the world health organization (WHO standard for PM10 = 50 μg/m3 and PM2.5 = 25 μg/m3) and Indian national ambient air quality standards (NAAQS for PM10 = 100 μg/m3 and PM2.5 = 60 μg/m3).The chemicals characterization of PM10 and PM2.5 samples (22 samples) for each season were made for water soluble ions using Ion Chromatography (IC) and trace metals by Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES) instrument. Results showed the dominance of crustal elements (Ca, Mg, Al, Fe and K), followed by marine aerosols (Na and K) and trace elements (Zn, Ba, Be, Ca, Cd, Co, Cr, Cu, Mn, Ni, Pb, Se, Sr and Te) emitted from road traffic in both PM10 and PM2.5 mass. The ionic species concentration in PM10 and PM2.5 mass consists of 47-65% of anions and 35-53% of cations with dominance of SO42− ions. Comparison of the metallic and ionic species in PM10 and PM2.5 mass indicated the contributions from sea and crustal soil emissions to the coarse particles and traffic emissions to fine particles.  相似文献   

4.
A woodstove changeout program was conducted within 16 homes on the Nez Perce Reservation in Idaho to evaluate the effectiveness of a woodstove changeout in improving indoor air quality. PM2.5 samples were collected within the common area (rooms where the stoves were located) of the homes both before and after the installation of cleaner burning EPA-certified stoves. During the pre- and post-changeout sampling, indoor PM2.5 mass, Organic Carbon (OC), Elemental Carbon (EC), and chemical markers of woodsmoke (including levoglucosan) were measured.Sampling results from this study showed that indoor air quality was improved in 10 of the 16 homes following the woodstove changeout and educational training program. Five homes had increased indoor PM2.5 concentrations following the changeout, while one home did not have final PM2.5 results for comparison. The median pre-changeout PM2.5 mass (as measured by TSI DustTraks) was 39.2 μg/m3, with a median post-changeout concentration of 19.0 μg/m3. This resulted in an overall 52% reduction in median indoor PM2.5, a 36% reduction in mean indoor PM2.5 and a 60% reduction in PM2.5 spikes when the old stoves were replaced with EPA-certified stoves. Another significant finding of the project was that targeted education and outreach is a critical component of the overall success of the program. Effective messaging to homeowners on proper use of their new stove is a necessary task of a woodstove changeout.  相似文献   

5.
Evidence concerning the health risks of coarse particles (PM10-2.5) is limited. There have been no multi-city epidemiologic studies of PM10-2.5 in developing Asian countries. We examine the short-term association between PM10-2.5 and daily mortality in three Chinese cities: Beijing, Shanghai, and Shenyang. PM10-2.5 concentrations were estimated by subtracting PM2.5 from PM10 measurements. Data were analyzed using the over-dispersed generalized linear Poisson models. The average daily concentrations of PM10-2.5 were 101 μg/m3 for Beijing (2007-2008), 50 μg/m3 for Shanghai (2004-2008), and 49 μg/m3 for Shenyang (2006-2008). In the single-pollutant models, the three-city combined analysis showed significant associations between PM10-2.5 and daily mortality from both total non-accidental causes and from cardiopulmonary diseases. A 10-μg/m3 increase in 1-day lagged PM10-2.5 was associated with a 0.25% (95% CI: 0.08 to 0.42) increase in total mortality, 0.25% (95% CI: 0.10 to 0.40) increase in cardiovascular mortality, and 0.48% (95% CI: 0.20 to 0.76) increase in respiratory mortality. However, these associations became statistically insignificant after adjustment for PM2.5. PM2.5 was significantly associated with mortality both before and after adjustment for PM10-2.5. In conclusion, there were no statistically significant associations between PM10-2.5 and daily mortality after adjustment for PM2.5 in the three Chinese cities.  相似文献   

6.
Three monthly 24-hour samples of airborne aerosols (PM10 and PM2.5) were collected at an urban and a rural site of the North central, semi-arid part of India during May 2006 to March 2008. Seven trace metals (Pb, Zn, Ni, Fe, Mn, Cr and Cu) were determined for both sizes. The annual mean concentration for PM10 was 154.2 µg/m3 and 148.4 µg/m3 at urban and rural sites whereas PM2.5 mean concentration was 104.9 µg/m3 and 91.1 µg/m3 at urban and rural sites, respectively. Concentrations of PM10 and PM2.5 have been compared with prescribed WHO standards and NAAQS given by CPCB India and were found to be higher. Weekday/weekend variations of PM10 and PM2.5 have been studied at both monitoring sites. Lower particulate pollutant levels were found during weekends, which suggested that anthropogenic activities are major contributor of higher ambient particulate concentration during weekdays. Significant seasonal variations of particulate pollutants were obtained using the daily average concentration of PM10 and PM2.5 during the study period. PM2.5/PM10 ratios at urban and rural sites were also determined during the study period, which also showed variation between the seasons. Three factors have been identified using Principal Component Analysis at the sampling sites comprising resuspension of road dust due to vehicular activities, solid waste incineration, and industrial emission at urban site whereas resuspension of soil dust due to vehicular emission, construction activities and wind blown dust carrying industrial emission, were common sources at rural site.  相似文献   

7.
Atmospheric particulate matter (PM2.5, PM10 and TSP) were sampled synchronously during three monitoring campaigns from June 2007 to February 2008 at a coastal site in TEDA of Tianjin, China. Chemical compositions including 19 elements, 6 water-solubility ions, organic and elemental carbon were determined. principle components analysis (PCA) and chemical mass balance modeling (CMB) were applied to determine the PM sources and their contributions with the assistance of NSS SO42, the mass ratios of NO3 to SO42 and OC to EC. Air mass backward trajectory model was compared with source apportionment results to evaluate the origin of PM. Results showed that NSS SO42 values for PM2.5 were 2147.38, 1701.26 and 239.80 ng/m3 in summer, autumn and winter, reflecting the influence of sources from local emissions. Most of it was below zero in summer for PM10 indicating the influence of sea salt. The ratios of NO3 to SO42 was 0.19 for PM2.5, 0.18 for PM10 and 0.19 for TSP in winter indicating high amounts of coal consumed for heating purpose. Higher OC/EC values (mostly larger than 2.5) demonstrated that secondary organic aerosol was abundant at this site. The major sources were construction activities, road dust, vehicle emissions, marine aerosol, metal manufacturing, secondary sulfate aerosols, soil dust, biomass burning, some pharmaceutics industries and fuel-oil combustion according to PCA. Coal combustion, marine aerosol, vehicular emission and soil dust explained 5-31%, 1-13%, 13-44% and 3-46% for PM2.5, PM10 and TSP, respectively. Backward trajectory analysis showed air parcels originating from sea accounted for 39% in summer, while in autumn and winter the air parcels were mainly related to continental origin.  相似文献   

8.
PM2.5 (particle with an aerodynamic diameter less than 2.5 µm) was measured in different microenvironments of Hong Kong (including one urban tunnel, one Hong Kong/Mainland boundary roadside site, two urban roadside sites, and one urban ambient site) in 2003. The concentrations of organic carbon (OC), elemental carbon (EC), water-soluble ions, and up to 40 elements (Na to U) were determined. The average PM2.5 mass concentrations were 229 ± 90, 129 ± 95, 69 ± 12, 49 ± 18 µg m− 3 in the urban tunnel, cross boundary roadside, urban roadside, and urban ambient environments, respectively. Carbonaceous particles (sum of organic material [OM] and EC) were the dominant constituents, on average, accounting for ∼ 82% of PM2.5 emissions in the tunnel, ∼ 70% at the three roadside sites, and ∼ 48% at the ambient site, respectively. The OC/EC ratios were 0.6 ± 0.2 and 0.8 ± 0.1 at the tunnel and roadside sites, respectively, suggesting carbonaceous aerosols were mainly from vehicle exhausts. Higher OC/EC ratio (1.9 ± 0.7) occurred at the ambient site, indicating contributions from secondary organic aerosols. The PM2.5 emission factor for on-road diesel-fueled vehicles in the urban area of Hong Kong was 257 ± 31 mg veh− 1 km− 1, with a composition of ∼ 51% EC, ∼ 26% OC, and ∼ 9% SO4=. The other inorganic ions and elements made up ∼ 11% of the total PM2.5 emissions. OC composed the largest fraction (∼ 51%) in gasoline and liquid petroleum gas (LPG) emissions, followed by EC (∼ 19%). Diesel engines showed higher emission rates than did gasoline and LPG engines for most pollutants, except for V, Br, Sb, and Ba.  相似文献   

9.
Indoor particle number and PM2.5 concentrations were investigated in a radio station surrounded by busy roads. Two extensive field measurement campaigns were conducted to determine the critical parameters affecting indoor air quality. The results indicated that indoor particle number and PM2.5 concentrations were governed by outdoor air, and were significantly affected by the location of air intake and design of HVAC system. Prior to the upgrade of the HVAC system and relocation of the air intake, the indoor median particle number concentration was 7.4×103 particles/cm3 and the median PM2.5 concentration was 7 μg/m3. After the relocation of air intake and the redesign of the HVAC system, the indoor particle number concentration was between 2.3×103 and 3.4×103 particles/cm3, with a median value of 2.7×103 particles/cm3, and the indoor PM2.5 concentration was in the range of 3–5 μg/m3, with a median value of 4 μg/m3. By relocating the air intake of the HVAC, the outdoor particle number and PM2.5 concentrations near the air intake were reduced by 35% and 55%, respectively. In addition, with the relocation of air intake and the redesign of the HVAC system, the particle number penetration rate was reduced from 42% to 14%, and the overall filtration efficiency of the HVAC system (relocation of air intake, pre-filter, AHU and particle losses in the air duct) increased from 58% to 86%. For PM2.5, the penetration rate after the upgrade was approximately 18% and the overall filtration efficiency was 82%. This study demonstrates that by using a comprehensive approach, including the assessment of outdoor conditions and characterisation of ventilation and filtration parameters, satisfactory indoor air quality can be achieved, even for those indoor environments facing challenging outdoor air conditions.  相似文献   

10.
Indoor and outdoor concentrations of PM2.5 were measured for 24 h during heating and non-heating seasons in a rural solid fuel burning Native American community. Household building characteristics were collected during the initial home sampling visit using technician walkthrough questionnaires, and behavioral factors were collected through questionnaires by interviewers. To identify seasonal behavioral factors and household characteristics associated with indoor PM2.5, data were analyzed separately by heating and non-heating seasons using multivariable regression. Concentrations of PM2.5 were significantly higher during the heating season (indoor: 36.2 μg/m3; outdoor: 22.1 μg/m3) compared with the non-heating season (indoor: 14.6 μg/m3; outdoor: 9.3 μg/m3). Heating season indoor PM2.5 was strongly associated with heating fuel type, housing type, indoor pests, use of a climate control unit, number of interior doors, and indoor relative humidity. During the non-heating season, different behavioral and household characteristics were associated with indoor PM2.5 concentrations (indoor smoking and/or burning incense, opening doors and windows, area of surrounding environment, building size and height, and outdoor PM2.5). Homes heated with coal and/or wood, or a combination of coal and/or wood with electricity and/or natural gas had elevated indoor PM2.5 concentrations that exceeded both the EPA ambient standard (35 μg/m3) and the WHO guideline (25 μg/m3).  相似文献   

11.
Emissions from indoor biomass burning are a major public health concern in developing areas of the world. Less is known about indoor air quality, particularly airborne endotoxin, in homes burning biomass fuel in residential wood stoves in higher income countries. A filter‐based sampler was used to evaluate wintertime indoor coarse particulate matter (PM10‐2.5) and airborne endotoxin (EU/m3, EU/mg) concentrations in 50 homes using wood stoves as their primary source of heat in western Montana. We investigated number of residents, number of pets, dampness (humidity), and frequency of wood stove usage as potential predictors of indoor airborne endotoxin concentrations. Two 48‐h sampling events per home revealed a mean winter PM10‐2.5 concentration (± s.d.) of 12.9 (± 8.6) μg/m3, while PM2.5 concentrations averaged 32.3 (± 32.6) μg/m3. Endotoxin concentrations measured from PM10‐2.5 filter samples were 9.2 (± 12.4) EU/m3 and 1010 (± 1524) EU/mg. PM10‐2.5 and PM2.5 were significantly correlated in wood stove homes (r = 0.36, P < 0.05). The presence of pets in the homes was associated with PM10‐2.5 but not with endotoxin concentrations. Importantly, none of the other measured home characteristics was a strong predictor of airborne endotoxin, including frequency of residential wood stove usage.  相似文献   

12.
We conducted a randomized trial of portable HEPA air cleaners in the homes of children age 6–12 years with asthma in the Yakima Valley, Washington. All families received asthma education while intervention families also received two HEPA cleaners (child's bedroom, living room). We collected 14-day integrated samples of endotoxin in settled dust and PM10 and PM10-2.5 in the air of the children's bedrooms at baseline and one-year follow-up, and used linear regression to compare follow-up levels, adjusting for baseline. Seventy-one families (36 HEPA, 35 control) completed the study. Baseline geometric mean (GSD) endotoxin loadings were 1565 (6.3) EU/m2 and 2110 (4.9) EU/m2, respectively, in HEPA vs. control homes while PM10 and PM10-2.5 were 22.5 (1.9) μg/m3 and 9.5 (2.9) μg/m3, respectively, in HEPA homes, and 19.8 (1.8) μg/m3 and 7.7 (2.0) μg/m3, respectively, in control homes. At follow-up, HEPA families had 46% lower (95% CI, 31%–57%) PM10 on average than control families, consistent with prior studies. In the best-fit heterogeneous slopes model, HEPA families had 49% (95% CI, 6%–110%) and 89% lower (95% CI, 28%–177%) PM10-2.5 at follow-up, respectively, at 50th and 75th percentile baseline concentrations. Endotoxin loadings did not differ significantly at follow-up (4% lower, HEPA homes; 95% CI, −87% to 50%).  相似文献   

13.
The intensity, frequency, duration, and contribution of distinct PM2.5 sources in Asian households have seldom been assessed; these are evaluated in this work with concurrent personal, indoor, and outdoor PM2.5 and PM1 monitoring using novel low-cost sensing (LCS) devices, AS-LUNG. GRIMM-comparable observations were acquired by the corrected AS-LUNG readings, with R2 up to 0.998. Twenty-six non-smoking healthy adults were recruited in Taiwan in 2018 for 7-day personal, home indoor, and home outdoor PM monitoring. The results showed 5-min PM2.5 and PM1 exposures of 11.2 ± 10.9 and 10.5 ± 9.8 µg/m3, respectively. Cooking occurred most frequently; cooking with and without solid fuel contributed to high PM2.5 increments of 76.5 and 183.8 µg/m3 (1 min), respectively. Incense burning had the highest mean PM2.5 indoor/outdoor (1.44 ± 1.44) ratios at home and on average the highest 5-min PM2.5 increments (15.0 µg/m3) to indoor levels, among all single sources. Certain events accounted for 14.0%-39.6% of subjects’ daily exposures. With the high resolution of AS-LUNG data and detailed time-activity diaries, the impacts of sources and ventilations were assessed in detail.  相似文献   

14.
This study examines the chemical composition of aerosols over the Greater Istanbul Area. To achieve this 325 (PM10) aerosol samples were collected over Bosphorus from November 2007 to June 2009 and were analysed for the main ions, trace metals, water-soluble organic carbon (WSOC), organic (OC) and elemental carbon (EC).PM10 levels were found to be in good agreement with those measured by the Istanbul Municipality air quality network, indicating that the sampling site is representative of the Greater Istanbul Area. The main ions measured in the PM10 samples were Na+, Ca2+ and non-sea-salt sulphates (nss-SO42−). On average, 31% of Ca2+ was found to be associated with carbonates. Trace elements related to human activities (as Pb, V, Cd and Ni) obtained peak values during winter due to domestic heating, whereas natural origin elements like Al, Fe and Mn peaked during the spring period due to dust transport from Northern Africa. Organic carbon was found to be mostly primary and elemental carbon was strongly linked to fuel oil combustion and traffic. Both OC and EC concentrations increased during winter due to domestic heating, while the higher WSOC to OC ratio during summer can be mostly attributed to the presence of secondary, oxidised and more soluble organics. Factor analysis identified six components/sources for aerosol species in PM10, namely traffic/industrial, crustal, sea-salt, fuel-oil combustion, secondary and ammonium sulfate.  相似文献   

15.
Aerosol mass (PM10 and PM2.5) and detailed elemental composition were measured in monthly composites during the calendar year of 2007 at a site in Lahore, Pakistan. Elemental analysis revealed extremely high concentrations of Pb (4.4 μg m− 3), Zn (12 μg m− 3), Cd (0.077 μg m− 3), and several other toxic metals. A significant fraction of the concentration of Pb (84%), Zn (98%), and Cd (90%) was contained in the fine particulate fraction (PM2.5 and smaller); in addition, Zn and Cd were largely (≥ 60%) water soluble. The 2007 annual average PM10 mass concentration was 340 μg m− 3, which is well above the WHO guideline of 20 μg m− 3. Dust sources were found to contribute on average (maximum) 41% (70%) of PM10 mass and 14% (29%) of PM2.5 mass on a monthly basis. Seasonally, concentrations were found to be lowest during the monsoon season (July-September). Principle component analysis identified seven factors, which combined explained 91% of the variance of the measured components of PM10. These factors included three industrial sources, re-suspended soil, mobile sources, and two regional secondary aerosol sources likely from coal and/or biomass burning. The majority of the Pb was found to be associated with one industrial source, along with a number of other toxic metals including As and Cr. Cadmium, another toxic metal, was found at concentrations 16 times higher than the maximum exposure level recommended by the World Health Organization, and was concentrated in one industrial source that was also associated with Zn. These results highlight the importance of focusing control strategies not only on reducing PM mass concentration, but also on the reduction of toxic components of the PM as well, to most effectively protect human health and the environment.  相似文献   

16.
High levels of PM2.5 exposure and associated health risks are of great concern in rural China. For this study, we used portable PM2.5 monitors for monitoring concentrations online, recorded personal time‐activity patterns, and analyzed the contribution from different microenvironments in rural areas of the Yangtze River Delta, China. The daily exposure levels of rural participants were 66 μg/m3 (SD 40) in winter and 65 μg/m3 (SD 16) in summer. Indoor exposure levels were usually higher than outdoor levels. The exposure levels during cooking in rural kitchens were 140 μg/m3 (SD 116) in winter and 121 μg/m3 (SD 70) in summer, the highest in all microenvironments. Winter and summer values were 252 μg/m3 (SD 103) and 204 μg/m3 (SD 105), respectively, for rural people using biomass for fuel, much higher than those for rural people using LPG and electricity. By combining PM2.5concentrations and time spent in different microenvironments, we found that 92% (winter) and 85% (summer) of personal exposure to PM2.5in rural areas was attributable to indoor microenvironments, of which kitchens accounted for 24% and 27%, respectively. Consequently, more effective policies and measures are needed to replace biomass fuel with LPG or electricity, which would benefit the health of the rural population in China.  相似文献   

17.
Hairdressers are exposed to particulate matter (PM), a known air pollutant linked to adverse health effects. Still, studies on occupational PM exposures in hair salons are sparse. We characterized indoor air PM concentrations in three salons primarily serving an African/African American (AA) clientele, and three Dominican salons primarily serving a Latino clientele. We also assessed the performance of low-cost sensors (uRAD, Flow, AirVisual) by comparing them to high-end sensors (DustTrak) to conduct air monitoring in each salon over 3 days to quantify work shift concentrations of PM2.5, respirable PM (RPM), and PM10. We observed high spatial and temporal variability in 30-min time-weighted average (TWA) RPM concentrations (0.18–5518 μg/m3). Readings for the uRAD and AirVisual sensors were highly correlated with the DustTrak (R2 = 0.90–0.99). RPM 8-hour TWAs ranged from 18 to 383 µg/m3 for AA salons, and 9–2115 µg/m3 for Dominican salons. Upper 95th percentiles of daily RPM exposures ranged from 439 to 2669 µg/m3. The overall range of 30-min TWA PM2.5 and PM10 concentrations was 0.13–5497 and 0.36-,541 μg/m3, respectively. Findings suggest that hairdressers could be overexposed to RPM during an 8-hour shift. Additional comprehensive monitoring studies are warranted to further characterize temporal and spatial variability of PM exposures in this understudied occupational population.  相似文献   

18.
Asian dust storms (ADS) originating from the arid deserts of Mongolia and China are a well-known springtime meteorological phenomenon throughout East Asia. The ventilation systems in office utilize air from outside and therefore it is necessary to understand how these dust storms affect the concentrations of PM2.5 and PM10 in both the indoor and outdoor air. We measured dust storm pollution particles in an office building using a direct-reading instrument (PC-2 Quartz Crystal Microbalance, QCM) that measured particle size and concentration every 10 min for 1 h, three times a day. A three-fold increase in the concentrations of PM2.5 and PM10 in the indoor and outdoor air was recorded during the dust storms. After adjusting for other covariates, autoregression models indicated that PM2.5 and PM10 in the indoor air increased significantly (21.7 μg/m3 and 23.0 μg/m3 respectively) during dust storms. The ventilation systems in high-rise buildings utilize air from outside and therefore the indoor concentrations of fine and coarse particles in the air inside the buildings are significantly affected by outside air pollutants, especially during dust storms.  相似文献   

19.
Household fine particulate matter (PM2.5) pollution greatly impacts residents' health. To explore the current national situation of household PM2.5 pollution in China, a study was conducted based on literature published from 1998 to 2018. After extracting data from the literature in conformity with the requirements, the nationwide household-weighted mean concentration of household PM2.5 (HPL) was calculated. Subgroup analyses of spatial, geographic, and temporal differences were also done. The estimated overall HPL in China was 132.2 ± 117.7 μg/m3. HPL in the rural area (164.3 ± 104.5 μg/m3) was higher than that in the urban area (123.9 ± 122.3 μg/m3). For HPLs of indoor sampling sites, the kitchen was the highest, followed by the bedroom and living room. There were significant differences of geographic distributions. The HPLs in the South were higher than the North in four seasons. The inhaled dose of household PM2.5 among school-age children differed from provinces with the highest dose up to 5.9 μg/(kg·d). Countermeasures should be carried out to reduce indoor pollution and safeguard health urgently.  相似文献   

20.
Children in preschools were studied as an exceptionally vulnerable group to lung diseases due to their immature immune system. Few data are available in the literature addressing the exposure of children in preschools to ultrafine (>10 nm) particles. Exposure of children to fine, ultrafine (10 nm–1 µm) particles and black carbon particles present inside and near two preschools in Nur-Sultan, Kazakhstan, during Fall 2019 was investigated. For Preschool I, the average daily (6 h) indoor (outdoor) PM1, PM2.5, and PM10 concentrations over three-week measurements were 15.0 (SD 12.5) µg/m3, 34.6 (SD 35.1) µg/m3, and 47.2 (SD 45.2) µg/m3, respectively. Average indoor UFP concentrations (>10.0 nm) including candle burning events were 5.20 × 103 (SD 8.80 × 103) particles/cm3, with the background UFP concentration to be 3.30 × 103 (SD 1.80 × 103) particles/cm3. In Preschool II, the average UFP concentration (>30.0 nm) in the morning and afternoon was 3.94 × 103 (SD 5.34 × 102) and 3.36 × 103 (SD 1.90 × 103) particles/cm3, respectively. Indoor black carbon (BC) concentrations were correlated with the outdoor smoking activity. The major sources of the indoor particles in the preschools were dust resuspension, candle burning, and infiltrated outdoor particles.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号