首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Lee I  Marchant RE 《Ultramicroscopy》2003,97(1-4):341-352
The interactions between fibrinogen ligands and platelet receptor alpha(IIb)beta(3) were studied under physiological conditions by atomic force microscopy (AFM). Two linear peptide sequences in fibrinogen, RGD and HHLGGAKQAGDV, play central roles in the regulation of hemostasis and thrombosis by facilitating adhesion and aggregation of platelets. In order to measure the interactions (i.e., debonding force), oligopeptides, GSSSGaaa, where aaa is -RGDSPA or -HHLGGAKQAGDV, were synthesized and grafted on to the surface of AFM probe tips. The interaction forces between a peptide-modified AFM probe tip and platelet surface were determined from pN to nN levels using AFM force measurements. Our results show that the zero kinetic off-rate, K(off)(0), for RGDSPA is significantly smaller than that for HHLGGAKQAGDV, under the consideration of flexible receptor surfaces. From our analysis, the K(off)(0), the single molecular binding energy E(b), and the transition state x(b), were extracted from the data, and estimated to be 1.53s(-1), -2.64x10(-20)J and 1.03A for the RGD-alpha(IIb)beta(3) system, and 47.58s(-1), 2.67x10(-20), 1.09A for the HHLGGAKQAGDV-alpha(IIb)beta(3) system, respectively.  相似文献   

2.
This research studies the effects of microstructures of poly vinylidene fluoride (PVDF) on its adhesion force with the probe of an atomic force microscope (AFM). The adhesion problem is currently a bottleneck for the development of micro-electro-mechanical systems (MEMS). Understanding the surface adhesion mechanisms is an important step to advance MEMS technology. In the present work, we fabricated PVDF thinfilms using spin casting and in situ corona poling methods. The microstructure was thus changed from α to the mixture of β and γ phases. Surface forces were then evaluated using an AFM. It was found that the adhesion forces between the AFM probe and the polymer surfaces were affected by microstructures. This article discusses details of our findings.  相似文献   

3.
The transforming growth factor β1 (TGF-β1) is a human cytokine which has been demonstrated to modulate cell surface integrin repertoire. In this work integrin expression in response to TGF-β1 stimulation has been investigated on the surface of human osteoblast-like cells. We used atomic force microscopy (AFM) and confocal laser scanning microscopy to assess integrin expression and to evaluate their distribution over the dorsal side of the plasma membrane. AFM probes have been covalently functionalised with monoclonal antibodies specific to the β1 integrin subunit. Force curves have been collected in order to obtain maps of the interaction between the immobilized antibody and the respective cell membrane receptors. Adhesion peaks have been automatically detected by means of an ad hoc developed data analysis software. The specificity of the detected interactions has been assessed by adding free antibody in the solution and monitoring the dramatic decrease in the recorded interactions. In addition, the effect of TGF-β1 treatment on both the fluorescence signal and the adhesion events has been tested. The level of expression of the β1 integrin subunit was enhanced by TGF-β1. As a further analysis, the adhesion force of the single living cells to the substrate was measured by laterally pushing the cell with the AFM tip and measuring the force necessary to displace it. The treatment with TGF-β1 resulted in a decrease of the cell/substrate adhesion force. Results obtained by AFM have been validated by confocal laser scanning microscopy thus demonstrating the high potential of the AFM technique for the investigation of cell surface receptors distribution and trafficking at the nanoscale.  相似文献   

4.
The distribution of EP3 receptors on a living cell surface was quantitatively studied by atomic force microscopy (AFM). Green fluorescent protein (GFP) was introduced to the extracellular region of the EP3 receptor on a CHO cell. A microbead was used as a probe to ensure certain contact area, whose surface was coated with anti-GFP antibody. The interactions between the antibodies and GFP molecules on the cell surface were recorded to observe the distribution of the receptors. The result indicated that EP3 receptors were distributed on the CHO cell surface not uniformly but in small patches coincident with immunohistochemical observation. Repeated measurements on the same area of cell surface gave confirmation that it was unlikely that the receptors were extracted from the cell membrane during the experiments. The measurement of single molecular interaction between GFP and the anti-GFP antibody was succeeded on the cell surface using compression-free force spectroscopy. The value of separation work required to break a single molecular pair was estimated to be about 1.5 x 10(-18)J. The number of EP3 receptor on the CHO cell surface was estimated using this value to be about 1 x 10(4) under the assumption that the area of the cell surface was about 5,000 microm(2). These results indicated that the number of receptors on a living cell surface could be quantified through the force measurement by the AFM.  相似文献   

5.
Ge G  Han D  Lin D  Chu W  Sun Y  Jiang L  Ma W  Wang C 《Ultramicroscopy》2007,107(4-5):299-307
Magnetic AC mode (MAC mode) atomic force microscopy (AFM), a novel type of tapping mode AFM in which the cantilever is driven directly by a magnetic field, is a powerful tool for imaging with high spatial resolution and better signal-to-noise in liquid environment. It may largely extend the application of AFM to living samples, especially those are sensitive to cantilever forces, even to multilayer tissue samples. However, there are few reports on the imaging of living cells by MAC mode AFM previously. In our present study, we explore the optimal imaging conditions of MAC mode AFM on living astrocytes and fresh arterial intima surface. We also used nude tips for PicoTREC panel (i.e., Aux in BNC, a new data collecting channel) to image living samples and discussed its difference with phase imaging. We show that living biological samples can be imaged by MAC mode AFM at details of comparable resolution as those by high resolution scanning electron microscopy. Furthermore, the combination of height, amplitude, phase and TREC panel signals provide abundant informations for the characteristics of living samples, such as topography, profile, stiffness and adhesion.  相似文献   

6.
The force sensor of an atomic force microscope (AFM) is sensitive enough to measure single molecular binding strengths by means of a force-distance curve. In order to combine high-force sensitivity with the spatial resolution of an AFM in topography mode, adhesion mode has been developed. Since this mode generates a force-distance curve for every pixel of an image, the measurement speed in liquid is limited by the viscous drag of the cantilever. We have equipped our adhesion mode AFM with a cantilever that has a low viscous drag in order to reach pixel frequencies of 65 Hz. Optimized filtering techniques combined with an auto-zero circuitry that reduces the drift in the deflection signal, limited high- and low-frequency fluctuations in the height signal to 0.3 nm. This reduction of the height noise, in combination with a thermally stabilized AFM, allowed the visualization of individual molecules on mica with an image quality comparable to tapping mode. The lateral resolution in both the topography and the simultaneously recorded adhesion image are only limited by the size of the tip. Hardware and software position feedback systems allows individual molecules to be followed in time during more than 30 min with scan sizes down to 60 x 60 nm2.  相似文献   

7.
Knowledge of the surface properties of microbial cells is a key to gain a detailed understanding of their functions in the natural environment and to efficiently exploit them in biotechnological processes. In this paper, we present force-distance curves recorded, by atomic force microscopy (AFM) in aqueous solutions, on various microbial samples: reconstituted S-layers, whole fungal spores and several bacterial strains. The approach and retraction curves exhibited important differences--depending on the type of microorganism, on the physiological state (dormancy versus germination) and on the environmental conditions (ionic strength)--which were shown to reflect differences in long-range surface forces, adhesion forces and mechanical properties. These data illustrate the great potential of AFM force measurements to elucidate the physical properties of microbial cells and to understand, at the molecular level, biointerfacial phenomena such as cell adhesion and cell aggregation.  相似文献   

8.
Atomic force microscopy (AFM) provides a new technology to visualize the cellular topography and quantify the molecular interactions at nanometer spatial resolution. In this work, AFM was used to image the cellular topography and measure the molecular force of pathological cells from B‐cell lymphoma patients. After the fluorescence staining, cancer cells were recognized by their special morphological features and then the detailed topography was visualized by AFM imaging. The AFM images showed that cancer cells were much rougher than healthy cells. CD20 is a surface marker of B cells and rituximab is a monoclonal antibody against CD20. To measure the CD20‐rituximab interaction forces, the polyethylene glycol (PEG) linker was used to link rituximab onto the AFM tip and the verification experiments of the functionalized probe indicated that rituximab molecules were successfully linked onto the AFM tip. The CD20‐rituximab interaction forces were measured on about 20 pathological cells and the force measurement results indicated the CD20‐rituximab binding forces were mainly in the range of 110–120 pN and 130–140 pN. These results can improve our understanding of the topography and molecular force of lymphoma pathological cells. SCANNING 35:40‐46, 2013. © 2012 Wiley Periodicals, Inc.  相似文献   

9.
Polysaccharide properties probed with atomic force microscopy   总被引:7,自引:0,他引:7  
In recent years, polysaccharides have been extensively studied using atomic force microscopy (AFM). Owing to its high lateral and vertical resolutions and ability to measure interaction forces in liquids at pico‐ or nano‐Newton level, the AFM is an excellent tool for characterizing biopolymers. The first imaging studies showed the morphology of polysaccharides, but gradually more quantitative image analysis techniques were developed as the AFM grew easier to use in aqueous liquids and in non‐contact modes. Recently, AFM has been used to stretch polysaccharides and characterize their physicochemical properties by application of appropriate polymer stretching models, using a technique called single‐molecule force spectroscopy. From application of such models as the wormlike chain, freely jointed chain, extensible‐freely jointed chain, etc., properties such as the contour length, persistence length and segment elasticity or spring constant can be calculated for polysaccharides. The adhesion between polysaccharides and surfaces has been quantified with AFM, and this application is particularly useful for studying polysaccharides on microbial and other types of cells, because their adhesion is controlled by biopolymer characteristics. This review presents a synthesis of the theory and techniques currently in use to probe the physicochemical properties of polysaccharides with AFM.  相似文献   

10.
Rituximab is an exciting monoclonal antibody drug approved for treating B‐cell lymphomas and its target is the CD20 antigen which is expressed on the surface of B cells. In recent years, the variable efficacies of rituximab among different lymphoma patients have become an important clinical issue and urgently need to be solved for further development of antibodies with enhanced efficacies. In this work, atomic force microscopy (AFM) was used to investigate the nanoscale distribution of CD20 on the surface of tumour B cells from lymphoma patients to examine its potential role in the clinical therapeutic effects of rituximab. By performing ROR1 fluorescence labelling (ROR1 is a specific tumour cell surface marker) on the bone marrow cells prepared from B‐cell lymphoma patients, the tumour B cells were recognized, and then AFM tips carrying rituximabs via polyethylene glycol crosslinkers were moved to the tumour cells to probe the specific CD20‐rituximab interactions. By applying AFM single‐molecule force spectroscopy (SMFS) at the local areas (500×500 nm2) on the surface of tumour B cells, the nanoscale distributions of CD20 on the surface of tumour B cells were mapped, visually showing that CD20 distributed heterogeneously on the cell surface. Bone marrow cell samples from three clinical B‐cell lymphoma cases were collected to analyze the binding affinity and nanoscale distribution of CD20 on tumour cells. The experimental results showed that CD20 distribution on tumour cells were to some extent related to the clinical therapeutic outcomes while the CD20‐rituximab binding forces did not have distinct effects to the clinical outcomes. These results can provide novel insights in understanding the rituximab's clinical efficacies from the nanoscale distribution of CD20 on the tumour cells at single‐cell and single‐molecule levels.  相似文献   

11.
Successful imaging of living human cells using atomic force microscopy (AFM) is influenced by many variables including cell culture conditions, cell morphology, surface topography, scan parameters, and cantilever choice. In this study, these variables were investigated while imaging two morphologically distinct human cell lines, namely LL24 (fibroblasts) and NCI H727 (epithelial) cells. The cell types used in this study were found to require different parameter settings to produce images showing the greatest detail. In contact mode, optimal loading forces ranged between 2-2.8 x 10(-9) and 0.1-0.7 x 10(-9) (N) for LL24 and NCI H727 cells respectively. In tapping (AC) mode, images of LL24 cells were obtained using cantilevers with a spring constant of at least 0.32 N/m, while NCI H727 cells required a greater spring constant of at least 0.58 N/m. To obtain tapping mode images, cantilevers needed to be tuned to resonate at higher frequencies than their resonance frequencies to obtain images. For NCI H727 cells, contact mode imaging produced the clearest images. For LL24 cells, contact and tapping mode AFM produced images of comparable quality. Overall, this study shows that cells with different morphologies and surface topography require different scanning approaches and optimal conditions must be determined empirically to achieve images of high quality.  相似文献   

12.
The atomic force microscope (AFM) has evolved from an imaging device into a multifunctional and powerful toolkit for probing the nanostructures and surface components on the exterior of bacterial cells. Currently, the area of application spans a broad range of interesting fields from materials sciences, in which AFM has been used to deposit patterns of thiol‐functionalized molecules onto gold substrates, to biological sciences, in which AFM has been employed to study the undesirable bacterial adhesion to implants and catheters or the essential bacterial adhesion to contaminated soil or aquifers. The unique attribute of AFM is the ability to image bacterial surface features, to measure interaction forces of functionalized probes with these features, and to manipulate these features, for example, by measuring elongation forces under physiological conditions and at high lateral resolution (<1 Å). The first imaging studies showed the morphology of various biomolecules followed by rapid progress in visualizing whole bacterial cells. The AFM technique gradually developed into a lab‐on‐a‐tip allowing more quantitative analysis of bacterial samples in aqueous liquids and non‐contact modes. Recently, force spectroscopy modes, such as chemical force microscopy, single‐cell force spectroscopy, and single‐molecule force spectroscopy, have been used to map the spatial arrangement of chemical groups and electrical charges on bacterial surfaces, to measure cell–cell interactions, and to stretch biomolecules. In this review, we present the fascinating options offered by the rapid advances in AFM with emphasizes on bacterial research and provide a background for the exciting research articles to follow. SCANNING 32: 74–96, 2010. © 2010 Wiley Periodicals, Inc.  相似文献   

13.
The authors fabricated a probe tip with various sizes and examined the size dependency of the probe tip on the distribution of retraction forces between actin and anti-actin. Probe tips of various sizes were fabricated by two-photon polymerization methods on a micro cantilever of an atomic force microscope (AFM). The authors succeeded in fabricating a spherical tip having a smooth surface and the tip size varied between φ 0.8 and 5.5 μm. Anti-actin was immobilized on the fabricated probe tips and force curves were measured against an actin-immobilized mica substrate by AFM to analyze the retraction forces. The histograms of retraction forces showed that the single-molecular retraction force between actin and anti-actin was ca. 350–400 pN. It was observed that the average retraction forces for each tip size correlated with the square of the tip radius.  相似文献   

14.
Adapting atomic force microscopy for cell biology   总被引:11,自引:0,他引:11  
We present details of our AFM modifications to produce an adaptable imaging system for the cell biologist. We have designed and validated a new inverted microscope interface and a scan head with increased Z-range, based upon the TopoMetrix Explorer AFM. We have utilised these changes, together with home-made glass ball cantilevers, to obtain topographical information over cells with large Z-dimension (over 15 microm high), and mapped calcitonin-calcitonin receptor binding forces in living bone cells. We conclude that modified AFM can be used to evaluate intermolecular events in living cells and that this approach will ensure general application to the study of receptor-ligand interactions under truly physiological conditions.  相似文献   

15.
A combined optical and atomic force microscope for live cell investigations   总被引:6,自引:0,他引:6  
We present an easy-to-use combination of an atomic force microscope (AFM) and an epi-fluorescence microscope, which allows live cell imaging under physiological conditions. High-resolution AFM images were acquired while simultaneously monitoring either the fluorescence image of labeled membrane components, or a high-contrast optical image (DIC, differential interference contrast). By applying two complementary techniques at the same time, additional information and correlations between structure and function of living organisms were obtained. The synergy effects between fluorescence imaging and AFM were further demonstrated by probing fluorescence-labeled receptor clusters in the cell membrane via force spectroscopy using antibody-functionalized tips. The binding probability on receptor-containing areas identified with fluorescence microscopy ("receptor-positive sites") was significantly higher than that on sites lacking receptors.  相似文献   

16.
The atomic force microscope (AFM) is a powerful tool to investigate surface and submembranous structures of living cells under physiological conditions at high resolution. These properties enabled us to study the interaction between live hepatic natural killer (NK) cells, also called pit cells, and colon carcinoma cells in vitro by AFM. In addition, the staining for filamentous actin and DNA was performed and served as a reference, because actin and nuclear observations at the light microscopic level during the cytotoxic interaction between these two cell types have been presented earlier. In this study, we collected evidence that conjugation of hepatic NK cells with CC531s colon carcinoma cells results in a decreased binding of CC531s cells to the substratum as probed with the AFM in contact mode as early as 10 min after cell contact (n = 11). To avoid the lateral forces and smearing artefacts of contact mode AFM, non-contact imaging was performed on hepatic NK/CC531s cell conjugates, resulting in identical observations (n = 3). In contrast, the first cytotoxic signs, as determined with the nuclear staining dye Hoechst 33342, could be observed 3 h after the start of the co-culture. This study illustrates that the AFM can be used to probe early cytotoxic effects of effector to target cell contact in nearby physiological conditions. Other routine cytotoxicity tests detect the first cytotoxic effects after 1.5-3 h co-incubation at the earliest.  相似文献   

17.
目的:探讨原子力显微镜(AFM)在研究人脐静脉内皮细胞(ECV304)表面形貌、超微结构及纳米机械性质等方面的应用,讨论ECV304超微结构和机械性质与其功能的关系。方法:利用AFM对ECV304细胞的表面形貌及生物机械性质进行表征与测量。结果:在AFM下观察到用普通光学显微镜难以观察到的ECV304细胞的独特的形态结构,如细胞骨架、伪足及细胞边缘微丝等。ECV304细胞呈现长梭形、多角形、圆形等多种形态,细胞表面平均粗糙度为320.52±75.98 nm,表面均匀分布微绒毛,细胞周围有铺展的圆盘状物质。力曲线定量分析得出针尖与细胞表面的非特异性粘附力为75±14 pN。结论:通过AFM成像和力曲线测量表明,ECV304细胞呈圆形,多角形,梭形等多种形态,针尖与细胞膜表面问的粘附力比较小,约75±14pN。  相似文献   

18.
During the emergence of multicellular organisms, molecular mechanisms evolved to allow maintenance of anatomical integrity and self-recognition. We propose that carbohydrates from proteoglycans, as the most peripheral cell surface, and matrix molecules might have provided these key adhesion and recognition functions. If so, the Porifera as the simplest metazoans alive today should retain, at least in part, proteoglycan adhesion and recognition mechanisms. Early work on cell adhesion of dissociated marine sponge cells provided important phenomenological evidence for cell sorting. Here is reviewed recent work on molecular mechanisms of cell recognition and adhesion mediated by cell surface proteoglycans purified from three marine sponge species, Microciona prolifera, Halichondria panicea, and Cliona celata. Biochemical characterization of isolated proteoglycans showed that each species expressed a unique type of primordial molecule named glyconectins. These proteoglycans displayed species-specific self-recognition and adhesion in color-coded bead, cell, and blotting assays. The specificity of homophilic proteoglycan to proteoglycan interactions in the Porifera approaches the binding selectivity of the evolutionarily advanced immunoglobulin superfamily system. Such xeno-selectivity may be a new paradigm for the molecular self-recognition, which was a fundamental requirement in the self/non-self discrimination during the emergence of multicellularity and further divergence of species. We have used atomic force microscopy (AFM) technology to directly measure intermolecular binding strength between individual pairs of ligand and receptor molecules in physiological solution. Homophilic glyconectin interactions were investigated by AFM after covalent attachment of the protein core to the sensor tip and to a flat surface, leaving the carbohydrates unmodified. AFM measurements of the binding strength between glyconectins indicated that one pair of molecules could theoretically hold the weight of 1,600 cells in physiological solution. These results provided the first essential and quantitative evidence that proteoglycan-proteoglycan binding can perform the adhesion function that we have assigned to it. Our investigations with purified proteoglycans from the marine sponge M. prolifera (glyconectin 1) using bead and cell adhesion assays have provided evidence that a new molecular mechanism of polyvalent and specific glycan-glycan binding between proteoglycans can mediate cell recognition and adhesion. Partial sequencing of the glycans has revealed two new cell adhesion carbohydrate structures: (3)GlcNAc(3OSO3)beta1-3Fuc and Pyr4,6Galbeta1-4GlcNAcbeta1-3Fuc.  相似文献   

19.
Kim H  Noh J  Hara M  Lee H 《Ultramicroscopy》2008,108(10):1140-1143
Mixed self-assembled monolayers (SAMs) to immobilize streptavidin on a gold surface were investigated by measuring the pull-off force between an AFM tip and a biotin-modified surface using CFM. Biotin-LC-NHS was modified on SAMs prepared from a mixed solution of cystamine and MEOH. Increased pull-off forces between the AFM tip and the surface were observed with an increased cystamine mole fraction in the solution. Streptavidin was immobilized onto biotin-LC-NHS modified mixed SAMs and analyzed by tapping AFM. Also, the formation of mixed SAMs containing MUOH and MBDA was confirmed using CFM. The measured pull-off forces on the only MBDA surface were larger than those on the surface with MUOH. These results can be applied to determine an optimal mixing ratio of MUOH and MBDA SAMs that reduces non-specific streptavidin binding onto a surface.  相似文献   

20.
Jin H  Ma S  Song B  Ma L  Pi J  Chen X  Chen Y  Cai J 《Scanning》2011,33(6):413-418
Gene transfer has been proven to be a promising approach for treatment of several diseases. The cytotoxicity of transfection reagents is one of the key factors for clinical applications. The cytotoxicity of liposome has been extensively studied. However, its effects on the adhesion and spreading of transformed cells are still unclear. In this study, the cytotoxic effects of liposome on cell viability and mitochondrial membrane potential of HEK293 cells were first evaluated. Then, an atomic force microscope (AFM) was recruited to investigate the effects of liposome on the adhesion and spreading of HEK293 cells. AFM data indicated that liposome induced a significant decrease in number of cellular pseudopodia and cell-surface particles, in cell-surface roughness, and in average adhesion force of cell membranes. The AFM data implied that liposome impaired the adhesion and spreading of HEK293 cells.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号