共查询到20条相似文献,搜索用时 109 毫秒
1.
本介绍了在玻璃工业中采用辐射测温仪进行非接触测温,控温时,为获得准确可靠的测量值,应如何正确安装,使用及维护辐射测温仪的经验。 相似文献
2.
3.
4.
5.
6.
7.
本文介绍通过检测机器的振动周期来间接测定封闭式压缩机转速的方法。深入研究了各种可能引起测量误差的原因,并提出了解决办法。实验证明,所研制的以微处理器为基础的转速测试仪能排除各种干扰,工作稳定,读数准确可靠。 相似文献
8.
9.
10.
11.
The Calibration of a Water Vapor Radiometer 总被引:1,自引:0,他引:1
12.
A theoretical analysis is made of a microwave radiometer which utilizes no predetection amplification. The minimum detectable temperature, defined as the temperature which results in an output signal-to-noise ratio of unity, is shown to be (?/BM) (T0/2K?0)1/2 where B is the predetection bandwidth, M is the crystal figure of merit, T0 is the ambient temperature, K is Boltzmann's constant, and ?0 is the postdetection time constant. The predicted minimum detectable temperature for the millimeter wavelength region is about 50°K for a one-second postdetection time constant. Some experimental measurements are presented which show good agreement with the theoretical results. Because of the absence of predetection amplification, the sensitivity of the crystal-video radiometer is relatively poor; however, it is quite adequate for those applications where large temperatures are expected, such as gaseous discharge research. The simplicity of the crystal-video radiometer and its adaptability to complete solid-state instrumentation make it quite attractive for radiometric measurements from space probes and satellites. 相似文献
13.
15.
16.
17.
18.
19.
对一种新型电校准辐射计的面响应不均匀性、线性和绝对响应度等特性进行了研究。在0.7~750μW范围内测得其线性度优于0.5%。面响应不均匀性的测量是利用小的激光光斑在探测器的灵敏面进行二维扫描。在探测器的主要灵敏面内,相对响应度与到探测器中心的距离表现为二次曲面关系。本对不同光斑大小、光束横截面上不同功率分布以及光斑入射到探测器表面的不同位置引起的测量误差进行了分析和研究。给出了是否需要修正的判据和需要修正时所应采用的修正方法,这种方法也适用于其它类型的电校准辐射计,利用该修正方法可以显降低测量不确定度。实验考查了面响应不均匀性的影响,实验结果证明了修正方法的正确性。 相似文献
20.
George P. Eppeldauer Donald C. Lynch 《Journal of research of the National Institute of Standards and Technology》2000,105(6):813-828
A transmission-type light-trap silicon radiometer has been developed to hold the NIST spectral power and irradiance responsivity scales between 406 nm and 920 nm. The device is built from replaceable input apertures and tightly packed different-size silicon photodiodes. The photodiodes are positioned in a triangular shape tunnel such that beam clipping is entirely eliminated within an 8 field-of-view (FOV). A light trap is attached to the output of the radiometer to collect the transmitted radiation and to minimize the effect of ambient light. The photodiodes, selected for equal shunt resistance, are connected in parallel. The capacitance and the resultant shunt resistance of the device were measured and frequency compensations were applied in the feedback network of the photocurrent-to-voltage converter to optimize signal-, voltage-, and loop-gain characteristics. The trap radiometer can measure either dc or ac optical radiation with high sensitivity. The noise-equivalent-power of the optimized device is 47 fW in dc mode and 5.2 fW at 10 Hz chopping. The relative deviation from the cosine responsivity in irradiance mode was measured to be equal to or less than 0.02 % within 5° FOV and 0.05 % at 8° FOV. The trap-radiometer can transfer irradiance responsivities with uncertainties comparable to those of primary standard radiometers. Illuminance and irradiance meters, holding the SI units (candela, color- and radiance-temperature), will be calibrated directly against the transfer standard trap-radiometer to obtain improved accuracy in the base-units. 相似文献