首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 343 毫秒
1.
Solid oxide fuel cell gas turbine (SOFC-GT) hybrid systems for producing electricity have received much attention due to high-predicted efficiencies, low pollution and availability of natural gas. Due to the higher value of peak power, a system able to meet fluctuating power demands while retaining high efficiencies is strongly preferable to base load operation. SOFC systems and hybrid variants designed to date have had narrow operating ranges due largely to the necessity of heat management within the fuel cell. Such systems have a single degree of freedom controlled and limited by the fuel cell. This study will introduce a new SOFC-GT hybrid configuration designed to operate over a 5:1 turndown ratio, while maintaining the SOFC stack exit temperature at a constant 1000 °C. The proposed system introduces two new degrees of freedom through the use of a variable-geometry nozzle turbine to directly influence system airflow, and an auxiliary combustor to control the thermal and power needs of the turbomachinery.  相似文献   

2.
Power generation using gas turbine (GT) power plants operating on the Brayton cycle suffers from low efficiencies, resulting in poor fuel to power conversion. A solid oxide fuel cell (SOFC) is proposed for integration into a 10 MW gas turbine power plant, operating at 30% efficiency, in order to improve system efficiencies and economics. The SOFC system is indirectly coupled to the gas turbine power plant, paying careful attention to minimize the disruption to the GT operation. A thermo-economic model is developed for the hybrid power plant, and predicts an optimized power output of 20.6 MW at 49.9% efficiency. The model also predicts a break-even per-unit energy cost of USD 4.65 ¢ kWh−1 for the hybrid system based on futuristic mass generation SOFC costs. This shows that SOFCs may be indirectly integrated into existing GT power systems to improve their thermodynamic and economic performance.  相似文献   

3.
Power generation using gas turbine (GT) power plants operating on the Brayton cycle suffers from low efficiencies, resulting in poor fuel to power conversion. A solid oxide fuel cell (SOFC) is proposed for integration into a 10 MW gas turbine power plant, operating at 30% efficiency in order to improve system efficiencies and economics. The SOFC system is semi-directly coupled to the gas turbine power plant, with careful attention paid to minimize the disruption to the GT operation. A thermo-economic model is developed for the hybrid power plant, and predicts an optimized power output of 21.6 MW at 49.2% efficiency. The model also predicts a breakeven per-unit energy cost of USD 4.70 ¢/kWh for the hybrid system based on futuristic mass generation SOFC costs. Results show that SOFCs can be semi-directly integrated into existing GT power systems to improve their thermodynamic and economic performance.  相似文献   

4.
A theoretical solid oxide fuel cell–gas turbine hybrid system has been designed using a Capstone 60 kW micro-gas turbine. Through simulation it is demonstrated that the hybrid system can be controlled to achieve transient capability greater than the Capstone 60 kW recuperated gas turbine alone. The Capstone 60 kW gas turbine transient capability is limited because in order to maintain combustor, turbine and heat exchangers temperatures within operating requirements, the Capstone combustor fuel-to-air ratio must be maintained. Potentially fast fuel flow rate changes, must be limited to the slower, inertia limited, turbo machinery air response. This limits a 60 kW recuperated gas turbine to transient response rates of approximately 1 kW s−1. However, in the SOFC/GT hybrid system, the combustor temperature can be controlled, by manipulating the fuel cell current, to regulate the amount of fuel sent to the combustor. By using such control pairing, the fuel flow rate does not have to be constrained by the air flow in SOFC/GT hybrid systems. This makes it possible to use the rotational inertia of the gas turbine, to buffer the fuel cell power response, during fuel cell fuel flow transients that otherwise limit fuel cell system transient capability. Such synergistic integration improves the transient response capability of the integrated SOFC gas turbine hybrid system. Through simulation it has been demonstrated that SOFC/GT hybrid system can be developed to have excellent transient capability.  相似文献   

5.
This paper compares the performance characteristics of a combined power system with solid oxide fuel cell (SOFC) and gas turbine (GT) working under two thermodynamic optimization strategies. Expressions of the optimized power output and efficiency for both the subsystems and the SOFC-GT hybrid cycle are derived. Optimal performance characteristics are discussed and compared in detail through a parametric analysis to evaluate the impact of multi-irreversibilities that take into account on the system behaviour. It is found that there exist certain new optimum criteria for some important design and operating parameters. Engineers should find the methodologies developed in this paper useful in the optimal design and practical operation of complex hybrid fuel cell power plants.  相似文献   

6.
A parametric study is conducted on a hybrid SOFC-GT cycle as part of a national program aiming to improve the efficiency of the actual gas turbine power plants and to better undertake the future investigations. The proposed power plant is mainly constituted by a Gas Turbine cycle, a SOFC system, and an ammonia water absorption refrigerating system. An external pre-reformer is installed before the SOFC. Heat recovery systems are adopted to valorize the waste heat at the SOFC and GT exhausts. The gas from the SOFC exhaust is also used as additional supply for the combustion chamber. An extraction is performed on the gas Turbine in order to feed the SOFC cycle by thermal heat flux at medium pressure.The equations governing the electrochemical processes, the energy and the exergy balances of the power plant components are established. Numerical simulation using EES software is performed. The influences of key operating parameters, such as humidity, pre-reforming fraction, extraction fraction from the Gas Turbine and fuel utilization on the performances of the SOFC-GT hybrid system are analyzed. Obtained results show that the integration of the SOFC enhances significantly the hybrid overall cycle efficiency. The increase of the ambient temperature and humidity reduces the system efficiencies. The utilization factor has a negative effect on the SOFC temperature and voltage. That leads to a decrease in the power plant performances. While the pre-reforming fraction, has a positive effect on the indicated parameters.  相似文献   

7.
Power generation using gas turbine (GT) power plants operating on the Brayton cycle suffers from low efficiencies, resulting in poor fuel to power conversion. A solid oxide fuel cell (SOFC) is proposed for integration into a 10-MW GT power plant, operating at 30% efficiency, in order to improve system efficiencies and economics. The SOFC system is indirectly coupled to the GT, in order to minimize the disruption to the GT operation. A thermo-economic model is developed to simulate the hybrid power plant and to optimize its performance using the method of Lagrange Multipliers. It predicts an optimized power output of 18.9 MW at 48.5% efficiency, and a breakeven per-unit energy cost of USD 4.54 ¢ kW h−1 for the hybrid system based on futuristic mass generation SOFC costs.  相似文献   

8.
Integrating fuel cells with conventional gas turbine based power plant yields higher efficiency, especially solid oxide fuel cell (SOFC) with gas turbine (GT). SOFCs are energy efficient devices, performance of which are not limited to Carnot efficiency and considered as most promising candidate for thermal integration with Brayton cycle. In this paper, a novel and optimal thermal integration of SOFC with intercooled-recuperated gas turbine has been presented. A thermodynamic model of a proposed hybrid cycle has been detailed along with a novelty of adoption of blade cooled gas turbine model. On the basis of 1st and 2nd law of thermodynamics, parametric analysis has been carried out, in which impact of turbine inlet temperature and compression ratio has been observed on various output parameters such as hybrid efficiency, hybrid plant specific work, mass of blade coolant requirement and entropy generation rate. For optimizing the system performance, entropy minimization has been carried out, for which a constraint based algorithm has been developed. The result shows that entropy generation of a proposed hybrid cycle first increases and then decreases, as the turbine inlet temperature of the cycle increases. Furthermore, a unique performance map has also been plotted for proposed hybrid cycle, which can be utilized by power plant designer. An optimal efficiency of 74.13% can be achieved at TIT of 1800 K and rp,c 20.  相似文献   

9.
This paper focuses on novel integration of high temperature solid oxide fuel cell coupled with recuperative gas turbine (with air-film cooling of blades) based hybrid power plant (SOFC-blade cooled GT). For realistic analysis of gas turbine cycle air-film blade cooling technique has been adopted. First law thermodynamic analysis investigating the combine effect of film cooling of blades, SOFC, applied to a recuperated gas turbine cycle has been reported. Thermodynamic modeling for the proposed cycle has been presented. Results highlight the influence of film cooling of blades and operating parameters of SOFC on various performance of SOFC-blade cooled GT based hybrid power plant. Moreover, parametric investigation has also been done to examine the effect of compressor pressure ratio, turbine inlet temperature, on hybrid plant efficiency and plant specific work. It has been found that on increasing turbine inlet temperature (TIT) beyond a certain limit, the efficiency of gas turbine starts declining after reaching an optimum value which is compensated by continuous increase in SOFC efficiency with increase in operating temperature. The net result is higher performance of hybrid cycle with increase in maximum cycle temperature. Furthermore, it has been observed that at TIT 1600 K and compression ratio 20, maximum efficiency of 73.46% can been achieved.  相似文献   

10.
This paper contributes a novel sustainability index and modified exergy indicators for conventional gas turbines and solid oxide fuel cell integrated gas turbine (SOFC-GT) hybrid power cycles. In this work, an intercooled gas turbine (Ic-GT) cycle is considered as a base cycle, which gives an additive advantage in lowering the power required for the compressor. Moreover, on SOFC integration with Ic-GT, the qualitative and quantitative performance are examined. Numerical modeling is done using MATLAB and an exclusive comparison has been made based on energy-exergy and sustainability analysis for the system and its components. On comparing the first law efficiency at turbine inlet temperature, TIT 1250K and rp = 18 for Ic-GT, intercooled recuperated gas turbine (Ic-RGT), and Ic–SOFC–RGT, it is 25.82%, 36.04%, and 64.78%, respectively. Similarly, second law efficiency is 11.43%, 22.33%, and 61.11% and the overall sustainability index is 1.12, 1.28, and 2.57 for Ic-GT, Ic-RGT, and Ic–SOFC–RGT, respectively. Nine other modified exergy-based parameters are used to identify the role of fuel and product exergy and then compare the most affected component in three configurations.  相似文献   

11.
固体氧化物燃料电池与燃气轮机混合发电系统   总被引:1,自引:0,他引:1  
基于固体氧化物燃料电池系统的高效率、环保性以及排气废热的巨大利用潜能,将其与燃气轮机组成混合发电装置,是一种极有前景的分布式发电方案.文章以SWP公司的加压型SOFC-小型燃气轮机混合循环系统为例,对固体氧化物燃料电池及燃气轮机混合循环系统的原理及发展现状作了分析,为我国固体氧化物燃料电池-燃气轮机混合循环系统的研制提供参考.  相似文献   

12.
This paper presents an analysis of the fuel flexibility of a methane-based solid oxide fuel cell-gas turbine (SOFC-GT) hybrid system. The simulation models of the system are mathematically defined. Special attention is paid to the development of an SOFC thermodynamic model that allows for the calculation of radial temperature gradients. Based on the simulation model, the new design point of system for new fuels is defined first; the steady-state performance of the system fed by different fuels is then discussed. When the hybrid system operates with hydrogen, the net power output at the new design point will decrease to 70% of the methane, while the design net efficiency will decrease to 55%. Similar to hydrogen, the net output power of the ethanol-fueled system will decrease to 88% of the methane value due to the lower cooling effect of steam reforming. However, the net efficiency can remain at 61% at high level due to increased heat recuperation from exhaust gas. To increase the power output of the hybrid system operating with non-design fuels without changing the system configuration, three different measures are introduced and investigated in this paper. The introduced measures can increase the system net power output operating with hydrogen to 94% of the original value at the cost of a lower efficiency of 45%.  相似文献   

13.
We present a steady‐state thermodynamic model of a hybrid solid oxide fuel cell (SOFC)–gas turbine (GT) cycle developed using a commercial process simulation software, AspenPlus?. The hybrid cycle model incorporates a zero‐dimensional macro‐level SOFC model. A parametric study was carried out using the developed model to study the effects of system pressure, SOFC operating temperature, turbine inlet temperature, steam‐to‐carbon ratio, SOFC fuel utilization factor, and GT isentropic efficiency on the specific work output and efficiency of a generic hybrid cycle with and without anode recirculation. The results show that system pressure and SOFC operating temperature increase the cycle efficiency regardless of the presence of anode recirculation. On the other hand, the specific work decreases with operating temperature. Overall, the model can successfully capture the complex performance trends observed in hybrid cycles. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

14.
高温燃料电池_燃气轮机混合发电系统性能分析   总被引:12,自引:3,他引:9       下载免费PDF全文
针对 高温燃料电池系统的高效率、环保性以及排气废热的巨大利用潜能,将其与燃气轮机组成混合装置进行发电是未来分布式发电的一种极有前景的方案。文中对高温燃料电池及混合循环系统作了简介,并对两种典型的高温燃料电池-燃气轮机混合循环发电系统进行了性能分析,这将为我国高温燃料电池-燃气轮机混合循环系统的研制提供参考。  相似文献   

15.
Although a solid oxide fuel cell combined with a gas turbine (SOFC-GT) has good performance, the temperature of exhaust from gas turbine is still relatively high. In order to recover the waste heat of exhaust from the SOFC-GT to enhance energy conversion efficiency as well as to reduce the emissions of greenhouse gases and pollutants, in this study a new combined cooling, heat and power (CCHP) system driven by the SOFC is proposed to perform the trigeneration by using ammonia-water mixture to recover the waste heat of exhaust from the SOFC-GT. The CCHP system, whose main fuel is methane, can generate electricity, cooling effect and heat effect simultaneously. The overall system performance has been evaluated by mathematical models and thermodynamic laws. A parametric analysis is also conducted to examine the effects of some key thermodynamic parameters on the system performance. Results indicate that the overall energy conversion efficiency exceeds 80% under the given conditions, and it is also found that the increasing the fuel flow rate can improve overall energy conversion efficiency, even though both the SOFC efficiency and electricity efficiency decrease. Moreover, with an increased compressor pressure ratio, the SOFC efficiency, electricity efficiency and overall energy conversion efficiency all increase. Ammonia concentration and pressure entering ammonia-water turbine can also affect the CCHP system performance.  相似文献   

16.
This work focuses on investigating the adaptability of solid oxide fuel cell-gas turbine (SOFC-GT) hybrid system for ship application under uncertain factors. The effect of rapids, wind and waves on the performance of ship SOFC-GT is analyzed. In addition, a novel control system combining fuzzy logic theory, temperature feedforward and coordination factor on-line adjustment is proposed to address the problem of load disturbances caused by uncertain factors. The results show that the proposed operation strategy can shorten the thermal response time inside fuel cell stacks by almost 49.97%, meanwhile, reducing the maximum temperature changing rate at the electrochemically active tri-layer cell composed of anode, electrolyte, and cathode (PEN structure) by around 17.86%. Moreover, the reasonable matching between air flow and fuel flow is an essential prerequisite to ensure the safe and efficient operation of ship SOFC-GT. While the SOFC-GT is working at full load, the results indicate that the fuel to air ratio cannot exceed 2.56?10?2 g/g. Finally, an application scenario of the 5000-ton river-to-sea cargo ship sails from Nanjing Port to Yangshan Port (Eastern China) is conducted to analyze the operation characteristics of ship SOFC-GT under uncertain factors. Two set of 1000 kW SOFC-GT systems with the electrical efficiency of 64.66% is designed for the target ship, the results conclude that the operation strategy of each SOFC-GT system supports 50% load is beneficial in reducing the power tracking time and SOFC temperature overshoot. The average electrical efficiency of 61.45% and 61.04% are achieved in winter and summer typical days respectively in the whole voyage.  相似文献   

17.
The efficiency of coal-fired power plant depends on various operating parameters such as main steam/reheat steam pressures and temperatures, turbine extraction pressures, and excess air ratio for a given fuel. However, simultaneous optimization of all these operating parameters to achieve the maximum plant efficiency is a challenging task. This study deals with the coupled ANN and GA based (neuro-genetic) optimization of a high ash coal-fired supercritical power plant in Indian climatic condition to determine the maximum possible plant efficiency. The power plant simulation data obtained from a flow-sheet program, “Cycle-Tempo” is used to train the artificial neural network (ANN) to predict the energy input through fuel (coal). The optimum set of various operating parameters that result in the minimum energy input to the power plant is then determined by coupling the trained ANN model as a fitness function with the genetic algorithm (GA). A unit size of 800 MWe currently under development in India is considered to carry out the thermodynamic analysis based on energy and exergy. Apart from optimizing the design parameters, the developed model can also be used for on-line optimization when quick response is required. Furthermore, the effect of various coals on the thermodynamic performance of the optimized power plant is also determined.  相似文献   

18.
《Journal of power sources》2002,111(1):121-129
The interaction realized by fuel cell—microturbine hybrids derive primarily from using the rejected thermal energy and combustion of residual fuel from a fuel cell in driving the gas turbine. This leveraging of thermal energy makes the high temperature molten carbonate fuel cells (MCFCs) ideal candidates for hybrid systems. Use of a recuperator contributes to thermal efficiency by transferring heat from the gas turbine exhaust to the fuel and air used in the system.Traditional control design approaches, consider a fixed operating point in the hope that the resulting controller is robust enough to stabilize the system for different operating conditions. On the other hand, adaptive control incorporates the time-varying dynamical properties of the model (a new value of gas composition) and considers the disturbances acting at the plant (load power variation).  相似文献   

19.
A techno-economic-environmental optimization of a pressurized solid oxide fuel cell-gas turbine (SOFC-GT) hybrid coupled with a small-scale seawater reverse osmosis (SWRO) desalination unit is presented. The overall exergy efficiency and cost rate of the system are maximized and minimized, respectively, using a genetic algorithm. The optimum solution selected, representing a trade-off between both optimization objectives, yields 2.4 MWe of electric power and 107 m3/day of permeate, at an overall exergy efficiency and cost rate of 70.5% and 0.0233 USD/s, respectively. These metrics compare favorably with those of alternative coupled SOFC-GT-thermal desalination systems previously optimized in the literature. Compared with the selected trade-off solution, single-objective optimizations of exergy efficiency and cost rate would permit a further improvement in exergy efficiency of 6%, and 9% reduction in cost rate, respectively. For the optimum economic solution, the SWRO unit would be effectively eliminated, with the system reducing to a SOFC-GT power plant. The system payback time is mostly sensitive to electricity prices, and ranges from two to ten years for typical economic parameters, but would become unprofitable in the most unfavorable economic context considered.  相似文献   

20.
Solid oxide fuel cell–micro-gas turbine (SOFC–MGT) hybrid power plants integrate a solid oxide fuel cell and a micro-gas turbine and can achieve efficiencies of over 60% even for small power outputs (200–500 kW). The SOFC–MGT systems currently developed are fueled with natural gas, which is reformed inside the same stack, but the use of alternative fuels can be an interesting option. In particular, as the reforming temperature of methanol and di-methyl-ether (DME) (200–350 °C) is significantly lower than that of natural gas (700–900 °C), the reformer can be sited outside the stack. External reforming in SOFC–MGT plants fueled by methanol and DME enhances efficiency due to improved exhaust heat recovery and higher voltage produced by the greater hydrogen partial pressure at the anode inlet. The study carried out in this paper shows that the main operating parameters of the fuel reforming section (temperature and steam-to-carbon ratio (SCR)) must be carefully chosen to optimise the hybrid plant performance. For the stoichiometric SCR values, the optimum reforming temperature for the methanol fueled hybrid plant is approximately 240 °C, giving efficiencies of about 67–68% with a SOFC temperature of 900 °C (the efficiency is about 72–73% at 1000 °C). Similarly, for DME the optimum reforming temperature is approximately 280 °C with efficiencies of 65% at 900 °C (69% at 1000 °C). Higher SCRs impair stack performance. As too small SCRs can lead to carbon formation, practical SCR values are around one for methanol and 1.5–2 for DME.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号