首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A multiplex polymerase chain reaction (M-PCR) assay for Haemophilus ducreyi, Treponema pallidum, and herpes simplex virus (HSV) was compared with clinical and standard laboratory methods for the diagnosis of genital ulcer disease (GUD) in 105 patients; 36% were human immunodeficiency virus (HIV)-seropositive. Chancroid (80%), syphilis (8%), and genital herpes (8%) were the most frequent diagnoses. H. ducreyi and HSV were isolated from ulcers of 43% and 18% of patients, respectively; in 35%, all cultures were negative and the laboratory diagnosis indeterminate. M-PCR detected H. ducreyi, T. pallidum, and HSV in 56%, 23%, and 26% of patients, respectively; (no definitive diagnosis, 6%). The proportion of patients with more than one agent was 4% by culture and 17% by M-PCR (P = .002). Resolved sensitivities of M-PCR for H. ducreyi and HSV cultures were 95% and 93%, respectively. The sensitivities of H. ducreyi and HSV cultures were 75% and 60%, respectively. HSV, detected in 47% of specimens from HIV-infected versus 16% from HIV-uninfected patients (P < .001), may be emerging as a more frequent cause of GUD.  相似文献   

2.
A multiplex PCR-based assay was developed for the detection of Bordetella pertussis in nasopharyngeal swab specimens. The assay simultaneously amplified two separate DNA targets (153 and 203 bp) within a B. pertussis repetitive element and a 438-bp target within the beta-actin gene of human DNA (PCR amplification control). PCR products were detected by a sensitive and specific liquid hybridization gel retardation assay. A total of 496 paired nasopharyngeal swab specimens were tested by both the PCR-based assay and culture. Although 30 (6%) of the specimens inhibited the amplification of the beta-actin target, in all 29 specimens studied, the inhibition disappeared on repeat testing or was easily overcome with a 1:8 dilution or less of specimen digest. Of the 495 specimen pairs yielding a final evaluable result by the PCR-based assay, 19.0% were positive by the PCR-based assay, whereas 13.9% were positive by culture (P < 0.0001). After resolving the PCR-positive, culture-negative results by testing an additional aliquot from these specimens by the multiplex PCR-based assay, the PCR-based assay had a sensitivity and specificity of 98.9 and 99.7%, respectively, compared with values of 73.4 and 100%, respectively, for culture. In comparison with patients with culture-confirmed pertussis, those with PCR-positive, culture-negative results were older and more likely to have had prolonged cough, immunization with pertussis vaccine, or treatment with erythromycin. This multiplex PCR-based assay is substantially more sensitive than culture and identifies specimens that contain inhibitors of PCR.  相似文献   

3.
This study compared the performances of three human papillomavirus (HPV) detection tests with specimens collected by three alternative procedures. The HPV tests included the Hybrid Capture Tube test (HCT), the microplate-based Hybrid Capture II test (HC II), and the MY09-MY11 L1 consensus primer PCR-based assay. Initial cervical specimens were collected from study subjects with a broom device, and after Papanicolaou smears were made, residual specimens were placed into PreservCyt (PC), a liquid cytology medium. A second specimen was collected from each subject and placed into Digene Specimen Transport Medium (STM). The device for collection of the second specimen alternated with consecutive subjects between a conical cytology brush and a Dacron swab. At the 1.0-pg/ml cutoff, the results of the HC II agreed well with those of the PCR. Specifically, when PCR data were restricted to the types found by the HC II (HPV types 16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, and 68), there was greater than 90% agreement between the HC II and PCR results with both STM and PC. At a lower cutoff (0.2 pg/ml), HC II-positive results increased further, especially when the test was applied to the PC specimens. However, false-positive HC II results were more often observed at the 0.2-pg/ml cutoff. HC II yielded the highest HPV positivity with specimens placed into PC, followed by specimens collected with a conical brush and placed into STM and, last, by those collected with a Dacron swab and placed into STM. Our results demonstrate the utility of both the STM and PC specimen collection methods and show good agreement between the HC II and PCR.  相似文献   

4.
The accuracy of detection of genital Neisseria gonorrhoeae infection in pooled urine samples by ligase chain reaction (LCR) was examined in three populations. Firstly, urine specimens from 300 female military recruits (FMR) were tested by LCR individually and in pools of four and six. Secondly, 300 urine specimens from middle-school students (MSS) were tested individually by LCR, and then the processed specimens were stored frozen for subsequent testing in pools of 4 and 10. Thirdly, 600 frozen urine specimens from high-school students (HSS) were tested by using the LCR pooling algorithm, i.e., testing processed specimens in pools of four in one test unit dose, and retesting individual specimens from positive pools. Finally, the pooling algorithm results were compared to culture results for a subset of 344 students from the original 600 HSS from whom cervical or urethral samples were taken at the discretion of the school nurse practitioners. Compared to individual testing of specimens by LCR in the FMR population, the pooling-by-four algorithm was 100% sensitive (5 of 5) and 100% pool specific (70 of 70), and the pool-by-six algorithm was 100% sensitive (5 of 5) and 100% pool specific (45 of 45). In the MSS population, the pool-by-4 algorithm was 95.8% sensitive (23 of 24) and 100% (52 of 52) pool specific, and the pool-by-10 algorithm was 95.8% sensitive (23 of 24) and 100% (17 of 17) pool specific. In the subset of 344 HSS from whom endocervical or urethral specimens were collected for culture, 31 were positive by LCR in urine and 26 were positive by culture. After results discrepant between culture and LCR were adjudicated by a confirmatory LCR test, the pooling algorithm was 93.8% (30 of 32) sensitive and 99.7% (311 of 312) specific. Culture from these 344 HSS was 81.3% (26 of 32) sensitive. The pooling algorithm reduced the cost of the N. gonorrhoeae LCR assay by 60% compared to individual testing of the HSS specimens and was both sensitive and specific.  相似文献   

5.
We used the Roche Amplicor PCR assay to compare urine and cervical swabs as sample material in the detection of Chlamydia trachomatis causing genital infections. The diagnostic performance of Amplicor PCR was compared with that of cell culture and the Gen-Probe PACE 2 assay with cervical specimens. If discrepant from other results, the specimens negative by PCR were diluted and reanalyzed to reveal PCR inhibitors. Of 666 patients, 39 (5.9%) were confirmed to have chlamydial infection. The respective sensitivity and specificity of Amplicor PCR were as follows: urine specimens, 82.0 and 99.7%; cervical specimens, 82.0 and 99.8%. Those for cell culture with cervical specimens were 84.6 and 100%. For the Gen-Probe PACE 2 assay, the sensitivity and specificity with cervical specimens were 79.5 and 100%, respectively. Without the effect of PCR inhibitors, the sensitivity of PCR with urine would have been 97.4%. Provided that the problems currently caused by inhibitors will be solved, the Amplicor PCR assay with urine specimens offers a tempting alternative for the diagnosis of C. trachomatis infection in women.  相似文献   

6.
To determine the etiology of genital ulcers and to assess the prevalence of human immunodeficiency virus (HIV) infection in ulcer patients in 10 US cities, ulcer and serum specimens were collected from approximately 50 ulcer patients at a sexually transmitted disease clinic in each city. Ulcer specimens were tested using a multiplex polymerase chain reaction assay to detect Haemophilus ducreyi, Treponema pallidum, and herpes simplex virus (HSV); sera were tested for antibody to HIV. H. ducreyi was detected in ulcer specimens from patients in Memphis (20% of specimens) and Chicago (12%). T. pallidum was detected in ulcer specimens from every city except Los Angeles (median, 9% of specimens; range, 0%-46%). HSV was detected in >/=50% of specimens from all cities except Memphis (42%). HIV seroprevalence in ulcer patients was 6% (range by city, 0%-18%). These data suggest that chancroid is prevalent in some US cities and that persons with genital ulcers should be a focus of HIV prevention activities.  相似文献   

7.
OBJECTIVE: To determine the accuracy of a DNA probe as a rapid diagnostic test for detecting colonization of the female genital tract by group B streptococci during pregnancy. METHODS: Two rayon-tipped applicators were used to collect secretions from the posterior vaginal wall of 440 pregnant women. One of the applicators was inoculated into selective Todd-Hewitt broth and used as the reference standard for identification of group B streptococci. The other applicator was used for analysis with the DNA probe, preceded by either 2.5 hours of incubation for the initial 75 patients, or 3.5 hours' incubation for the remaining women. Following hybridization with an acridinium-labeled probe, chemiluminescence was measured with a luminometer. RESULTS: The prevalence of positive cultures was 20%. For the initial 75 patients whose cultures were amplified by incubation for 2.5 hours, the DNA probe had a sensitivity of 44%, specificity 94%, positive predictive value 79%, and negative predictive value 77%. For the cultures that were incubated for 3.5 hours, respective values were 71, 90, 61, and 94%. All vaginal specimens that had an average initial cell count of 1.5 x 10(3) cells/mL were accurately detected by the probe after 3.5 hours' growth amplification. False-positive results occurred primarily when the specimens were grossly contaminated with blood (26 of 39). The mean time required to perform the assay, including 3.5 hours of growth amplification, was 4.3 hours. CONCLUSIONS: The DNA probe demonstrated good overall sensitivity and gave no false-negative results when group B streptococci were present in concentrations of 1 x 10(4) cells/mL or greater. Sensitivity improved significantly with 3.5 hours' growth amplification as compared with 2.5 hours (P < .05), reflecting better identification of lightly colonized patients.  相似文献   

8.
A multiplex polymerase chain reaction (M-PCR) assay that simultaneously detects the three major causes of genital ulcer disease (GUD), Haemophilus ducreyi, Treponema pallidum, and herpes simplex virus, was used to evaluate swab specimens for 38 sequential patients with GUD at a Thai sexually transmitted disease clinic. Subjects received clinical diagnoses and syndromic treatment. Swab specimens for H. ducreyi cultures and M-PCR were obtained. No H. ducreyi cultures were positive. Of 38 M-PCR specimens, 31 (81.6%) were positive for HSV, 1 (2.3%) for both HSV and T. pallidum, and none for H. ducreyi or T. pallidum alone; 6 (15.8%) were negative for all 3 pathogens. Clinical diagnoses corresponded poorly to M-PCR findings; none of 5 suspected cases of chancroid were positive by M-PCR and none of 1 for syphilis, but 21 of 24 suspected herpes lesions were confirmed by M-PCR. Human immunodeficiency virus infection status was known for 24 of 38 subjects; 11 (45.8%) were seropositive, and all 11 had HSV by M-PCR. HSV appeared to be the most common pathogen overall.  相似文献   

9.
The direct detection of gonococcal DNA in rectal and pharyngeal specimens was evaluated by using a DNA probe-based assay (Gen-Probe, Inc., San Diego, Calif.). Rectal (234) and pharyngeal (608) swab specimens were obtained from 249 men and 372 women attending sexually transmitted disease clinics in Las Vegas and Reno, Nevada. The prevalence of gonococcal infection by culture at the pharyngeal and rectal sites was 2.9% (16 of 548 specimens) in women and 2.7% (8 of 294 specimens) in men. No false-positive reactions were observed among the 234 rectal specimens tested. Two probe-positive, culture-negative specimens were detected among the 361 pharyngeal specimens obtained from women. Both of these samples were confirmed as Neisseria gonorrhoeae by a probe competition assay. The overall correlation of the DNA probe test with pharyngeal and rectal cultures was 99.4% (837 of 842 cultures), with a sensitivity of 87.5% (21 of 24 cultures) and specificity of 99.7% (816 of 818 cultures). The positive and negative predictive values of the DNA assay were 91.3 and 99.8%, respectively. The direct DNA probe assay provides an alternative to culture screening for rectal and/or pharyngeal gonococcal infections.  相似文献   

10.
11.
Gonorrhea is still a major sexually transmitted disease (STD) worldwide. Its etiologic diagnosis is based on identification of the causative agent, Neisseria gonorrhoeae, by culture of genital secretions, which is often hampered by difficulties of sample collection and transport. Alternatively, nucleic acid hybridization techniques for routine diagnosis of N. gonorrhoeae appear to be useful by eliminating problems associated with bacterial viability, particularly for surveillance of low-prevalence populations. Our study among 1,508 outpatients undergoing routine examination for common STDs used RNA/DNA hybridization with a DNA probe specific for N. gonorrhoeae (Gen Probe Pace 2) and classical culture. Of the 1,750 specimens tested, 12 were positive by DNA probe and culture. In 8 cases, only DNA probe was positive while culture was negative. In 3 of these discrepant cases clinical and epidemiological data suggested true N. gonorrhoeae infection. Thus, DNA probe assay for N. gonorrhoeae may greatly improve screening of N. gonorrhoeae among low-prevalence populations. However, culture remains mandatory for testing antimicrobial resistance of these highly communicable infectious agents.  相似文献   

12.
The identification of pathogens in patients with bacterial keratitis remains problematic because standard diagnostic tests are negative for 40 to 60% of patients. A cross-sectional study was undertaken to determine if PCR and sequence analysis of 16S ribosomal DNA (rDNA) could be used to detect bacterial pathogens in patients with keratitis. Corneal specimens were collected for culture and rDNA typing. Variable segments of each rDNA specimen were amplified by PCR, sequenced, and aligned with the sequences in GenBank. Eleven patients had microbiologically documented bacterial keratitis, while 17 patients had keratitis due to other causes. Nine (82%) of 11 bacterial keratitis patients were PCR positive; each sequencing result matched the culture results. Seventeen (100%) patients with nonbacterial keratitis were PCR negative. Our data suggest that 16S rDNA typing holds promise as a rapid alternative to culture for identifying pathogens in patients with bacterial keratitis.  相似文献   

13.
Skin biopsies of 36 patients with erythema migrans and acrodermatitis chronica atrophicans (ACA) before therapy and those of 8 patients after therapy were examined for Borrelia burgdorferi DNA by PCR. Skin biopsies of 27 patients with dermatological diseases other than Lyme borreliosis and those of 10 healthy persons were examined as controls. Two different primer sets targeting 23S rRNA (PCR I) and 66-kDa protein (PCR II) genes were used. PCR was performed with freshly frozen tissue (FFT) and paraffin-embedded tissue (PET). For FFT specimens of erythema migrans, 73% were positive by PCR I, 79% were positive by PCR II, and 88% were positive by combining PCR I and II. For PET specimens, PCR was less sensitive (PCR I, 44%; PCR II, 52%). For FFT specimens of ACA, PCR I was positive for two of five patients and PCR II was positive for four of five patients. B. burgdorferi was cultured from 79% of the erythema migrans specimens but not from any of the ACA lesions. Elevated B. burgdorferi antibodies were detected in sera of 74% of erythema migrans patients and 100% of ACA patients. All urine samples were negative by PCR II, whereas PCR I was positive for 27%. However, hybridization of these amplicons was negative. Sequencing of three amplicons identified nonborrelial DNA. In conclusion, urine PCR is not suitable for the diagnosis of skin borreliosis. A combination of two different primer sets achieves high sensitivity with skin biopsies. In early erythema migrans infection, culture and PCR are more sensitive than serology.  相似文献   

14.
BACKGROUND AND AIMS: Mutations of TP53, a tumor suppressor gene, are found in 60% to 70% of colorectal cancers. These mutations usually induce an overexpression caused by modification of the p53 protein conformation. The aim of this study was to investigate whether stool specimens of patients with colorectal cancer contain increased amounts of p53 protein. METHODS: p53 protein was measured using a sandwich enzyme immunoassay in the stool specimens of 52 patients: 25 with colorectal cancer, 4 with colorectal adenomas and 23 apparently free of gastrointestinal disease. Results were expressed as pg/mg of total protein. The presence of fecal occult-blood was searched using Hemoccult II and Hemolex (an immunochemical assay for human hemoglobin). RESULTS: Median concentrations of stool p53 protein were 16.6 pg/mg (range: 0-591 pg/mg) in patients with colorectal cancers, 39.1 pg/mg (range: 5-72 pg/mg) in patients with adenomas and 5.9 pg/mg (range: 0-65 pg/mg) in control subjects. Resection of colorectal cancers caused a marked decrease of stool p53 protein concentrations. When the cut-off value for stool p53 protein was set at 60 pg/mg of fecal protein (concentrations over the 95th percentile), the positivity of the assay was independent of tumor size and Astler-Coller stage, but weakly associated with rectal location of cancer. The sensitivity of stool p53 protein for colorectal cancer was 44%, and the specificity was 96%. In contrast, the sensitivity of Hemoccult II and Hemolex tests was 48% and 44%, whereas their specificity was 91% and 96%, respectively. CONCLUSION: The detection of p53 protein is achievable in stool, but this assay is not more efficient than fecal occult blood tests for detection of colorectal cancer.  相似文献   

15.
A coamplification PCR test for the direct detection of Neisseria gonorrhoeae and Chlamydia trachomatis in urethral and endocervical swabs and urine samples from men and women was compared to standard culture techniques. Processed specimens were amplified in single reaction tubes containing primers for both organisms, and PCR products were detected by a colorimetric microwell plate hybridization assay specific for each pathogen. Of 344 specimens from men, 45 (13.1%) urine specimens were PCR positive for C. trachomatis, 51 (14.8%) urethral swab specimens were PCR positive, and 29 urethral swab specimens (8.4%) were culture positive. After analysis of discrepancies, the resolved sensitivity and specificity of PCR for C. trachomatis were 96.2 and 99.3%, respectively, in urethral swab specimens, compared to 88.2 and 98.6% for urine specimens. Of the 192 specimens from women, 28 (14.6%) urine specimens were PCR positive for C. trachomatis, 32 (16.7%) endocervical specimens were PCR positive, and 19 (9.9%) endocervical specimens were culture positive. After analysis of discrepancies, the resolved sensitivity and specificity of PCR for C. trachomatis for endocervical specimens were both 100% compared to 100 and 99.4%, respectively, for urine specimens from women. In men, 68 (19.8%) urine specimens were PCR positive for N. gonorrhoeae, 73 (21.2%) urethral swabs were PCR positive, and 59 (17.2%) urethral swabs were culture positive. After analysis of discrepancies, the resolved sensitivity and specificity of PCR for N. gonorrhoeae were 97.3 and 97.0%, respectively, for urethral specimens compared to 94.4 and 98.5% for urine specimens. In women, 18 (9.4%) urine specimens were PCR positive for N. gonorrhoeae, 23 (12.0%) were endocervical swab PCR positive, and 15 (7.8%) endocervical specimens were culture positive. After analysis of discrepancies, the resolved sensitivity and specificity of PCR for N. gonorrhoeae were 100 and 99.4%, respectively, for endocervical specimens compared to 90.0 and 95.9% for female urine specimens. These results indicate that a multiplex PCR is highly sensitive for detecting both C. trachomatis and N. gonorrhoeae from a single urine or genital swab, providing a more cost-effective way of screening multiple pathogens.  相似文献   

16.
Type-specific serologic assays for herpes simplex virus (HSV) types 1 and 2 based on glycoprotein G-1 (gG-1) (HSV-1) and gG-2 (HSV-2) discriminate between antibodies against HSV-1 and HSV-2. We previously developed a Western blot assay using gG-1 and gG-2 expressed in baculovirus, performed extensive validation studies, and determined that it was both sensitive and specific for type-specific detection of HSV antibody. Here we report that, among a cohort of Thai military recruits, the serostatus of some individuals changed from positive to negative over time (6.6% among those ever positive for HSV-1, and 14.9% among those ever positive for HSV-2). We tested a subset of these specimens in three other gG-based assays: an enzyme-linked immunosorbent assay, an immunoblot strip assay, and a Western blot assay. Positive-to-negative shifts occurred in every assay; the frequency of the shifts ranged from 6. 1% to 21.2% of the specimen sets tested. There was only limited agreement among the assays concerning which individuals lost reactivity. This inaccuracy, exhibited by all of the assay protocols, was not predicted by validation studies employing specimens from cross-sectional studies and was most pronounced in HSV-2 testing. This argues for the inclusion of serial blood specimens in serologic assay validation procedures.  相似文献   

17.
Sixty-eight sera from the acute, recurrent, and provoked types of female genital herpes were compared for the seroprevalence of herpes simplex virus (HSV) types 1 and 2 by immunodot assay using HSV glycoprotein G. In the HSV-1-isolated patients, no HSV-2 antibodies were detected, whereas in the HSV-2-isolated patients, HSV-1 seroprevalence was 9% for the acute type, 89% for the provoked type (P < 0.005), and 55% for the recurrent type (P < 0.05). The natural history of female genital herpes and the possible protective role of pre-existing antibodies in preventing the acquisition or clinical manifestation of a subsequent HSV infection are discussed.  相似文献   

18.
Chlamydia trachomatis infections are the most prevalent sexually transmitted diseases (STDs) in the United States. In acute-care settings such as clinics and emergency rooms, a desirable chlamydia screening assay should exhibit good sensitivity and good specificity and should provide test results while the patient is still present. The Biostar Chlamydia OIA (Biostar, Inc., Boulder, Colo.) is an optical immunoassay (OIA) that provides test results in less than 30 min and that uses a test format that allows office-based testing. This assay is performed entirely at room temperature without the need for rotators or other specialized equipment. The goal of this study was to compare the performance of the Biostar Chlamydia OIA for the detection of C. trachomatis with the performance of cell culture, direct fluorescent-antibody (DFA) assay (Syva MicroTrak; Syva Co., Palo Alto, Calif.), and PCR (Roche Amplicor Chlamydia trachomatis; Roche, Branchburg, N.J.) for the detection of C. trachomatis infections in women attending an urban STD clinic. For calculations of relative test performance (sensitivity, specificity, and positive and negative predictive values), patient specimens that yielded positive results by two or more of the four assays (cell culture, DFA assay, PCR, and OIA) were classified as "true infections." By these criteria, 42 of 306 total specimens were classified as positive for C. trachomatis (positive prevalence, 13.7%), 11 (3.6%; 10 by PCR and 1 by DFA assay) were positive by a single assay, and 253 (82.7%) were negative by all four tests. All culture-positive specimens were also positive by at least one other assay. Among the culture-negative specimens, 14(5%) specimens were positive by two of the three non-culture-based assays used. By using the criterion that positivity by at least two of the tests indicated a true infection,the relative sensitivities were as follows: culture and PCR, 92.9% each; Biostar Chlamydia OIA, 73.8%; and DFA assay, 59.5%.  相似文献   

19.
To detect DNA sequences of herpes simplex virus (HSV) in neural and non-neural tissue sections in disseminated human neonatal HSV infection, a solution polymerase chain reaction (PCR) protocol was developed which amplified HSV thymidine kinase and host genomic DNA sequences that were hybridized with sequence-specific probes in Southern blots. Serial sections of formalin-fixed, paraffin embedded autopsy tissues were tested by PCR and compared to histology and HSV antigen detection. The sensitivity, specificity and reproducibility of this PCR protocol were determined on uninfected and HSV-infected mouse tissues and on HSV DNA from infected tissue culture cells. Samples estimated to contain as few as 60 copies of preserved HSV DNA target sequence gave a positive PCR result. In nine neonates that died during acute HSV infection, all non-neural tissues and a minority of neural tissues with histological lesions had HSV antigen; when DNA could be amplified, HSV DNA sequences were detected by PCR. Together, these findings indicate a direct role for virus in the pathogenesis of these lesions. In the same cases, some or all brain samples were negative for HSV antigen, but nevertheless had HSV DNA sequences detected by PCR. The possible explanations for this finding are discussed. In one neonate dying seven weeks after birth, HSV sequences were found in brain lesions in the absence of HSV antigen; neither HSV DNA nor antigen were found in non-neural tissues, suggesting a latent HSV infection in brain. It is practical to apply PCR methods to detect minute quantities of viral DNA in formalin-fixed, paraffin embedded autopsy tissues.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

20.
A comparison between a direct immunofluorescence assay (DFA) and the shell-vial culture (SVC) was conducted to evaluate their efficacies according to the quality and origin of the sample and the type of herpes simplex (HSV) responsible for the infection. The SVC detected all 58 HSV-infected samples, while the DFA detected only 49 (84.5%) positive samples. The DFA detected HSV type 1 in 22 of 89 samples (24.7%) and HSV type 2 in 27 of 96 samples (28.1%). Compared with the SVC, the DFA had a sensitivity of 75.8% for HSV type 1 and 93.1% for HSV type 2. The sensitivity of the DFA depends on the quality of the sample. Thus, while DFA is recommendable as a screening method, the SVC remains the method of choice for obtaining the maximum diagnostic yield from the sample.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号