首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
常低温下EGSB处理生活污水的影响因素研究   总被引:2,自引:0,他引:2  
在15~26℃的常低温条件下,采用EGSB处理生活污水,考察了进水流量、回流比、液体上升流速(Vup)、温度等因素对运行效果的影响。结果表明,当温度为26℃左右时,对于9~11 L/h的低进水流量,宜采用高回流比(1.6~2.5),对COD的去除率最高可达90%;对于15~24L/h的高进水流量,宜采用低回流比(0~0.6),对COD的去除率最高可达84%;当进水流量提高至30 L/h时,不宜回流,对COD的去除率降至77%;当进水流量分别为9、11、15、24、30 L/h时,最佳Vup分别为4.0、(3.1~3.6)、(2.7~3.4)、3.0和3.8 m/h,此时对COD的去除率分别高达90%、(87%~89%)、(83%~84%)、83%和77%;在无回流的条件下,适宜的进水流量为15~24 L/h,相应的HRT为0.5~0.8 h。当温度为15~26℃时,EGSB适宜的运行条件是高进水流量(15~24L/h)、高Vup(3.0 m/h)和低回流比(0~0.6),此时对COD的去除率高达81.9%以上。  相似文献   

2.
Lackner S  Terada A  Smets BF 《Water research》2008,42(4-5):1102-1112
A 1-d multi-population biofilm model was constructed to study the effect of heterotrophic activity on completely autotrophic ammonium (NH4+) removal in membrane-aerated (counter-diffusion) versus conventional biofilm systems (co-diffusion). Growth of heterotrophic bacteria (HB) was supported either solely by biomass decay products or by organic carbon (as chemical oxygen demand (COD)) in the influent. Three scenarios were considered: influence of HB growing on biomass decay products on steady-state performance (total nitrogen (TN) removal efficiency); influence of the influent COD/N ratio on steady-state performance (supplying COD in the influent); and impact of dynamic changes in the influent COD/N ratio on TN removal efficiency. The results revealed that the TN removal efficiency in the counter-diffusion biofilm was significantly different when HB were included in the simulations at NH4+ surface loads of LNH4>2.7 g - N m(-2) d(-1). Influent COD significantly altered the microbial community composition in the counter-diffusion biofilm and anaerobic NH4+ oxidation could not be sustained at COD/N>2. The co-diffusion system, however, was less affected and more than 50% of the TN removal originated from anaerobic NH4+ oxidation at those ratios. Perturbation experiments showed that step increases to influent COD/N ratios of 2 or higher over a period of 50 d or longer caused a loss of anaerobic NH4+ oxidation capacity which could not be regained within a reasonable time frame (>1000 d) in the counter-diffusion system. In contrast, simulating a 1-d sloughing event only caused a disturbance of 200 d although a maximum biofilm loss of 90-95% occurred. These results clearly indicate the importance of heterotrophic activity in autotrophic N removal biofilms, especially in counter-diffusion systems where they may compromise N removal capacity.  相似文献   

3.
利用厌氧折流板反应器(ABR) 处理屠宰废水,研究了负荷变化对厌氧折流板反应器(ABR)运行效果的影响。研究结果表明:厌氧折流板反应器对负荷变化的适应能力较强,ABR反应器的特殊结构为其提供了良好的抗负荷变化的能力。当维持进水COD浓度在2 500~3 000 mg/L范围之内,改变水力负荷,使HRT由27.5 h下降到15 h,COD去除率下降不超过5%;当维持反应器HRT为20 h时,改变有机负荷,使进水COD浓度由2 500 mg/L提高到4 800 mg/L,在负荷改变后的第二天,COD去除率仅降  相似文献   

4.
采用接种特定污泥的两相厌氧反应器处理高盐纤维素醚废水,重点考察了启动过程及其处理效果。试验结果表明,当产酸相的HRT为18 h时,其所能承受的最大容积负荷为8.18kg/(m3.d),此时其对COD的去除率为20%左右;当产甲烷相的HRT为24 h时,其所能承受的最大容积负荷为5.5 kg/(m3.d),此时其对COD的去除率为35%左右;产甲烷相对COD的去除率与产酸相出水的酸化度呈显著正相关。在产酸相进水COD为6 000 mg/L、产甲烷相进水pH值为7的条件下,当产酸相进水pH值为6、HRT为18 h及产甲烷相的HRT为48 h时,系统的处理效果较佳,出水COD为1 800 mg/L,对COD的总去除率可达70%左右。  相似文献   

5.
Anoxic treatment of phenolic wastewater in sequencing batch reactor   总被引:5,自引:0,他引:5  
Studies were conducted on the anoxic phenol removal using granular denitrifying sludge in sequencing batch reactor at different cycle lengths and influent phenol concentrations. Results showed that removal exceeded 80% up to an influent phenol concentration of 1050 mg/l at 6 h cycle length, which corresponded to 6.4 kg COD/m3/d. Beyond this, there was a steep decrease in phenol and COD removal efficiencies. This was accompanied by an increase in nitrite concentration in the effluent. On an average, 1 g nitrate-N was consumed per 3.4 g phenol COD removal. Fraction of COD available for sludge growth was calculated to be 11%.  相似文献   

6.
The purpose of this paper is to develop a Box-Jenkins time series transfer function model of the effluent COD using the influent COD, from a sewage treatment process. The data is from an industrial waste treatment plant encompassing a 14-month period.The work was done in 3 steps: (1) Box-Jenkins ARIMA (autoregressive integrated moving average) modeling of the influent COD; (2) ARIMA modeling of the effluent COD; and (3) development of a transfer function model for the waste treatment process.It was found that single difference models best described influent and effluent COD. For the transfer function model, the influent COD had an insignificant effect on the effluent COD.  相似文献   

7.
ABR-BAF工艺处理采油废水的中试研究   总被引:5,自引:2,他引:5  
进行了利用折流板厌氧反应器(ABR)-曝气生物滤池(BAF)工艺处理江汉油田马-25污水处理站采油废水的中试研究,主要考察了ABR的除油效果、提高废水可生化性的作用以及BAF的运行参数、处理效果等。研究结果表明:当废水流量为0.3m^3/h时,ABR反应器对油的去除率平均为83.5%,对COD的去除率平均为40.8%,出水BOD,/COD值提高了24.8%。ABR一方面去除了采油废水中的大部分油,另一方面提高了采油废水的可生化性。当BAF的水力负荷为0.6m/h、进水COD平均为203.5mg/L时,出水COD平均为85.7mg/L,平均去除率为57.9%;对SS的去除率为82.7%。组合工艺对油、COD、BOD,和SS的总去除率分别为96.1%-96.9%、58.2%~75.1%、80.0%-93.1%和80.7%~87.1%。扫描电镜(SEM)观察结果显示:生物膜结构紧密,并且观察到裂口虫,生物相非常丰富。ABR-BAF工艺能够很好地处理采油废水,出水水质满足污水二级排放标准。  相似文献   

8.
进水COD浓度及C/N值对脱氮效果的影响   总被引:20,自引:6,他引:20  
进水COD浓度及C/N值是影响系统反硝化效果的两个重要参数,为此研究了不同进水COD浓度在不同C/N值条件下的脱氮效果。结果表明:进水COD为150mg/L和200mg/L左右时,脱氮率随C/N值的增加而增加,而进水COD为100mg/L左右时,系统的脱氮率随时间增加而降低;进水COD浓度<200mg/L时,反应条件相同、C/N值相同而进水COD浓度不同,系统的脱氮率也不相同,进水COD浓度高,则脱氮率也高;当进水有机碳源浓度较低时,需要以进水COD浓度及C/N值共同来表示系统的脱氮能力。  相似文献   

9.
腈纶纱染色废水预处理工程的设计与运行   总被引:1,自引:0,他引:1  
为使厂内处理水质达到接管标准,采用水解/塔式生物滤池和混凝沉淀工艺作为腈纶纱染色废水预处理工艺。工程运行表明,原水COD≤1600mg/L时,适当增大回流量,水解/塔式生物滤池对COD的去除率可达57%;再经混凝沉淀处理,可去除45%的COD,出水COD〈380mg/L,能满足接管要求。另外,出水色度、SS也优于接管标准。因此,采用上述工艺对腈纶纱印染废水进行预处理在技术上是可行的,经济上也是可以接受的(运行费用为1.82元/m^3)。  相似文献   

10.
Laboratory activated sludge systems were operated at various COD:P ratios to study the effects of the influent phosphorus concentration on COD removal efficiency, cellular phosphorus, carbohydrate and protein contents, and alkaline phosphatase activity. In varying the COD:P ratio, the COD was held constant at 1000 mg l−1 and phosphorus concentrations of 1, 2, 3, 5, 7, 9, 10, 20, 35 and 50 mg l−1 were used. The optimum COD:P ratio for this study was found to be 100:1. Increasing the phosphorus concentration in the influent above one percent of the influent COD did not provide for an increase in the COD removal nor for significant changes in the cellular protein and carbohydrate content or the alkaline phosphatase activity.  相似文献   

11.
UASB/MBR组合工艺处理抗生素废水的研究   总被引:4,自引:3,他引:4  
采用UASB/MBR组合工艺处理抗生素废水,考察了其处理效果及影响因素.结果表明,当UASB的水力停留时间(HRT)为13 h、MBR的HRT为7.5 h时,系统对COD的去除效果最好,在进水COD为1 000~9 000 mg/L的条件下,出水COD可降至199 mg/L,对COD的总去除率可达80%以上.  相似文献   

12.
A laboratory scale anaerobic filter packed with synthetic high surface area trickling filter media was used to treat a low strength domestic wastewater averaging 288 mg 1−1 COD. The filter was operated for 60 days after reaching steady-state at 20, 25, 35°C at a loading rate of 0.02 lb COD ft−3 day−1 and 24 h hydraulic retention time. Filter effluent BOD5 averaged 38 mg 1−1 providing an average removal rate of 79%, and effluent COD averaged 78 mg 1−1, corresponding to a 73% removal rate. Removal efficiencies showed very little sensitivity to daily fluctuations in influent wastewater quality. The filter performance at 25 and 35°C was not significantly different, but BOD and TSS removal efficiency declined a: 20°C. Gas production averaged 0.027 ft−3 of gas per ft3 of influent wastewater, or 1.875 ft3 of gas per pound of influent COD. Gas composition averaged 30% nitrogen, 65% methane, and 5% carbon dioxide. Ammonia nitrogen and sulfides both increased during treatment. It is concluded that the anaerobic filter is a promising candidate for treatment of low strength wastewaters and that post treatment for sulfides and ammonia may be necessary.  相似文献   

13.
碳源对好氧颗粒污泥物理性状及除磷性能的影响   总被引:1,自引:0,他引:1  
采用气提升内循环序批式反应器,分别以葡萄糖、乙酸钠、乙醇为碳源培养好氧颗粒污泥,考察了3种颗粒污泥的物理性状、除磷性能及除磷机理。结果表明:3种颗粒污泥在结构和处理效果上均能长时间保持稳定,其中以乙酸钠和葡萄糖为碳源培养出的颗粒污泥具有较密实的内部结构和较好的沉降性能;在进水COD为600mg/L、TP为15mg/L时,以葡萄糖、乙酸钠、乙醇为碳源培养出的好氧颗粒污泥对TP的去除率分别为82%、88%、52%,其中对TP去除效果较好的两种好氧颗粒污泥(以乙酸钠、葡萄糖为碳源培养的)在反应初期均有较明显的释磷现象发生;以乙酸钠为碳源培养出的颗粒污泥在进水COD浓度为800mg/L时对TP的去除率达到最高(为92%).进一步加大COD负荷会使好氧颗粒污泥的除磷能力迅速下降。  相似文献   

14.
Khanal SK  Huang JC 《Water research》2003,37(9):2053-2062
A series of chemostat studies were conducted at a constant influent total organic carbon of 3750 mg/L (equivalent chemical oxygen demand (COD) of 10,000 mg/L) but at different influent sulfates of 1000, 3000 and 5000 mg/L in order to investigate the feasibility of online sulfide toxicity control through periodic oxygenation to the recycled biogas stream. The oxygen dosing for sulfide oxidation was regulated by using oxidation-reduction potential (ORP) as a controlling parameter. During oxygenation at elevated ORPs of -230 and -180 mV (50 and 100 mV above natural ORP of -280 mV, respectively), the dissolved and gaseous sulfides were completely eliminated which resulted in a concomitant improvement in methane yield by 56.3% at 5000 mg/L influent sulfate. However, at influent sulfates of 1000 and 3000 mg/L, both methane generation rate and sulfate removal efficiency were dropped appreciably at elevated ORPs. Facultative heterotrophs were found to consume as high as 66.3% of the influent COD during oxygenation. For effective sulfide oxidation at lower sulfate levels, it was no longer required to raise the ORP by as much as 50 or 100 mV. The actual needed ORP increase depended on the influent sulfate. This study had proven that the ORP-controlled oxygenation was reliable for achieving consistent online sulfide control during anaerobic treatment of high-sulfate wastewater.  相似文献   

15.
In the modified Ludzack–Ettinger process, high‐energy input is required in a nitrification tank. To address this issue, a new biological nitrification–denitrification system was constructed with a trickling filter for nitrification. The effects of recirculation rate of nitrified liquor and temperature through the treatment of municipal wastewater were evaluated. The highest DN removal efficiency was observed at 6.5 h of hydraulic retention in the denitrification tank and 350% of recirculation rate of nitrified liquid against the influent flow rate. The DN removal efficiencies did not reach theoretical values for all conditions tested because the COD/N ratios in the influent often decreased to less than 5 g‐COD/g‐N and temperatures dropped to less than 15°C in winter. The former inhibited the denitrification process and the latter significantly decreased the bioactivity of nitrifying bacteria. As such, this system is suitable in tropical and subtropical areas with annual minimum temperatures of over 15°C.  相似文献   

16.
17.
Boshoff G  Duncan J  Rose PD 《Water research》2004,38(11):2659-2666
An upflow anaerobic digestor was fed dried algal biomass as a carbon source to establish the feasibility of using micro-algal biomass as the sole carbon source for biological sulphate reduction. The effect of the COD:SO4 ratio on substrate consumption and sulphate removal efficiencies were assessed by varying the organic carbon content of the media. Similar COD removal efficiencies were obtained irrespective of the influent COD:SO4 ratios, which were 8.1, 11.2 and 15.0. However, the rates of COD removal did differ with influent COD:SO4 ratios. The percentage sulphate removed decreased as the ratio of COD:SO4 increased. Not all of the COD was used for sulphate reduction, with only 31% being accounted for.  相似文献   

18.
以微污染河道水为处理对象,研究了砾间接触氧化/水平潜流人工湿地复合工艺对水质的净化效果。经过26 d改变进水配比、曝气方式等的调控运行,成功启动复合工艺模拟装置,砾间接触氧化区(简称砾石区)的COD、NH4+-N去除率均稳定在75%左右,TN去除率在45%~60%。为进一步强化净化效果,探讨了砾石区水力停留时间(HRT)和砾石曝气区与非曝气区(O/A)分段进水配比对砾石区及后置潜流人工湿地出水水质的影响。当砾石区HRT为5 h时,砾石区对污染物的去除效果较好,COD、NH4+-N、TN平均去除率分别可达72%左右、75.28%、67.79%,人工湿地对三者的去除率分别为31%、43%、28%;当O/A区分段进水配比为1∶1时,对COD、NH4+-N的平均去除率较高,分别为77.39%和84.91%,分段进水配比为1∶2时,对TN的去除率最高,达到68.5%,人工湿地对TN的去除率为24.47%。因此,砾石区HRT为5 h为较佳参数,分段进水配比可根据进水污染状况灵活选择,研究结果可为实际工程应用提供理论支撑。  相似文献   

19.
Lin CK  Tsai TY  Liu JC  Chen MC 《Water research》2001,35(3):699-704
The characteristics of degradation/conversion of bio-refractory and the growth of a biofilm are investigated in laboratory-scale pre-ozonation and lifted moving-bed biological activated carbon (BAC) advanced treatment processes treating phenol, benzoic acid, aminobenzoic acid and petrochemical industry wastewater which contains acrylonitrile butadiene styrene (ABS). The optimal reaction time and ozone dosage of pre-ozonation for bio-refractory conversion were determined to be 30 min and 100-200 mg O3/hr, respectively. After pre-ozonation of 30 min treatment, BOD5/COD ratio of influent and effluent increased apparently from 20 to 35%, approximately. However, the change of pH in pre-ozonation was inconspicuous. The optimal flow rate of influent and air were controlled at 1.6 l/h and 120-150 nl/min in lifted moving-bed BAC advanced treatment reactor. A COD removal efficiency of 85-95% and 70-90% may be maintained by using an organic loading of 3.2-6.3 kg COD/m3 day and 0.6-1.6 kg-COD/m3 day with an HRT of 6.0 h as secondary and advanced treatment system, respectively. The time required for the BAC bed is be regenerated by a thermal regeneration is prolonged 4-5 times more than that of GAC system. It can be estimated that the enhanced COD removal capability of the biofilm was not only due to the increase in the COD removal capability of acclimated bacteria, but also due to species succession of bacteria in bio-film ecosystem.  相似文献   

20.
一体化IMBR处理低碳城市污水的脱氮研究   总被引:1,自引:0,他引:1  
在进水C/N为3、4、5和HRT为4、8、12h的条件下,研究了一体化间歇曝气膜生物反应器(IMBR)对COD、NH4^+-N、TN的去除效果。研究表明,在低C/N条件下,IMBR仍有很好的脱氮效果,出水COD、TN、NH4^+-N达到了GB18918--2002标准的一级A标准;随着C/N的增加则对各污染物的去除率都有所升高;随着HRT的延长,IMBR对COD、TN、NH4^+-N的去除率有较大的提高,但当HRT〉8h后,随着HRT的延长,对COD的去除率反而略有下降。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号