首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Tang X  Bruce JE  Hill HH 《Analytical chemistry》2006,78(22):7751-7760
Reduced flow rate electrospray ionization has been proven to provide improved sensitivity, less background noise, and improved limits of detections for ESI-MS analysis. Miniaturizing the ESI source from conventional electrospray to microelectrospray and further down to nanoelectrospray has resulted in higher and higher sensitivity; however, when effects of flow rate were investigated for atmospheric pressure ESI-IMS using a nanospray emitter, a striking opposite result was observed. The general tendency we observed in ESI-IMS was that higher flow rate offered higher ion signal intensity throughout a variety of conditions investigated. Thus, further efforts were undertaken to rationalize these contradictory results. It is well accepted that decreased flow rate increases both ionization efficiency and transmission efficiency, thus improving ion signal in ESI-MS. However, our study revealed that decreased flow rate results in decreased ion signal because ion transfer is constant, no matter how flow rate changes in ESI-IMS. Since ion transfer is constant in atmospheric pressure ESI-IMS, ionization efficiency can be studied independently, which otherwise is not possible in ESI-MS in which both ionization efficiency and transmission efficiency vary as conditions alter. In this article, we present a systematic study of signal intensity and ionization efficiency at various experimental conditions using ESI-IMS and demonstrate the ionization efficiency as a function of flow rate, analyte concentration, and solvent composition.  相似文献   

2.
Wu C  Siems WF  Asbury GR  Hill HH 《Analytical chemistry》1998,70(23):4929-4938
A hybrid atmospheric pressure ion mobility spectrometer is described which exhibits resolving power approaching the diffusion limit for singly and multiply charged ions (over 200 for the most favorable case). Using an electrospray ionization source and a downstream quadrupole mass spectrometer with electron multiplier as detector, this ESI-IMS-MS instrument demonstrates the potential of IMS for rapid analytical separations with a resolving power similar to liquid chromatography. The first measurements of gas-phase mobility spectra of mass-identified multiply charged ions migrating at atmospheric pressure are reported. These spectra confirm that collision cross sections are strongly affected by charge state. Baseline separations of multiply charged states of cytochrome c and ubiquitin demonstrate the improved resolving power of this instrument compared with previous atmospheric pressure ion mobility spectrometers. The effects of electric potential, initial pulse duration, ion-molecule reactions, ion desolvation, Coulombic repulsion, electric field homogeneity, ion collection, and charge on the resolving power of this ion mobility spectrometer are discussed.  相似文献   

3.
A secondary electrospray ionization (SESI) method was developed as a nonradioactive ionization source for ion mobility spectrometry (IMS). This SESI method relied on the gas-phase interaction between charged particles created by electrospray ionization (ESI) and neutral gaseous sample molecules. Mass spectrometry (MS) was used as the detection method after ion mobility separation for ion identification. Preliminary investigations focussed on understanding the ionization process of SESI. The performance of ESI-IMS and SESI-IMS for illicit drug detection was evaluated by determining the analytical figures of merit. In general, SESI had a higher ionization efficiency for small volatile molecules compared with the electrospray method. The potential of developing a universal interface for both GC- and LC-MS with an addition stage of mobility separation was demonstrated.  相似文献   

4.
Cui M  Ding L  Mester Z 《Analytical chemistry》2003,75(21):5847-5853
Cisplatin and its mono- and dihydrated complexes have been separated using a high-field asymmetric waveform ion mobility spectrometry (FAIMS) analyzer interfaced with electrospray ionization (ESI) and ion trap mass spectrometry (ITMS). The addition of helium to the nitrogen curtain/carrier gas in the FAIMS device improved both the sensitivity and selectivity of the electrospray analysis. Introduction of a three-component mixture as curtain/carrier gas, nitrogen, helium, and carbon dioxide, resulted in further improvements to sensitivity. Compared with conventional ESI-MS, the background chemical noise in the ESI-FAIMS-ITMS spectrum was dramatically reduced, resulting in over 30-fold improvement in the signal-to-noise ratio for cisplatin. Analytical results were linear over the concentration range 10-200 ng/mL for intact cisplatin with a corresponding detection limit determined of 0.7 ng/mL with no derivatization or chromatographic separation prior to analysis.  相似文献   

5.
6.
Surface ionization ion mobility spectrometry   总被引:1,自引:0,他引:1  
A surface ionization (SI) source was designed and constructed for ion mobility spectrometry (IMS). Compared with a conventional (63)Ni source, the surface ionization source is as simple and reliable, has an extended dynamic response range, is more selective in response, and does not have regulatory problems associated with radioactive ionization sources. The performance of this SI-IMS was evaluated with several different classes of compounds. Triethylamine was employed for studying the behavior of the ionization source under different source conditions and gaseous environments. Amines, tobacco alkaloids, and triazine herbicides were also investigated. Picogram level detection limits were achieved for target compounds with a response dynamic range of 5 orders of magnitude. Selective monitoring by IMS was also demonstrated. While the surface ionization source does not have the universality of response that is obtained with a (63)Ni ionization source, it is an excellent nonradioactive alternative for the ionization and ion mobility detection of those compounds to which it responds.  相似文献   

7.
Electrospray ionization (ESI) high-field asymmetric waveform ion mobility spectrometry (FAIMS) was combined with quadrupole, time-of-flight, and tandem mass spectrometry to characterize commercial and naturally occurring naphthenic acids (NA) mixtures. This new method provides quantitatively reliable mass and isomer distributions of NA components in approximately 3 min without extensive sample preparation. ESI-FAIMS-MS seems to be especially useful for characterization of fragile ions that cannot be detected by other methods. A unique part of this technique is separation of structural isomers that proved to be critical in determination of elemental composition and in structure elucidation. Tandem mass spectrometry of NA ions separated by FAIMS provides more information about the structure of NA than other methods in the field of NA analysis.  相似文献   

8.
Matz LM  Hill HH 《Analytical chemistry》2001,73(8):1664-1669
The separation of opiates and the primary metabolites was evaluated with ESI-IMS/MS. Seven opiate molecules were analyzed, and spectra were shown for each compound. The IMS separation of two isomers (morphine and norcodeine) was shown with baseline separation. Differences in the mobilities were found for the nonacetylated, monoacetylated, and biacetylated compounds. In this study, two primary findings are reported. First, IMS can easily separate metabolic isomers, and second, the two-dimensional separation capability of IMS/MS can be employed to confidently identify and separate both the opiates and metabolites. Although previous IMS studies have shown the separation of isomers, this is the first example to show the capability of IMS to separate metabolic isomers (within 70 s), a significant advantage in high-throughput screening for pharmacokinetic studies. Second, the monoacetylated and biacetylated compounds were found to form more compact ions for the sodium adducts in comparison to the protonated molecular ions. On the basis of the mobilities, information on structures and conformation can be deduced when sodium and protonated ions are compared.  相似文献   

9.
In this research work, the capability of low-temperature plasma (LTP) as an ionization source for ion mobility spectrometry (IMS) has been investigated for the first time. This new ionization source enhances the potential of IMS as a portable analytical tool and allows direct analysis of various chemical compounds without having to evaporate the analyte or seek a solvent or reagent whatsoever. The effects of parameters such as the flow rate of the discharge gas, plasma voltage, and positioning of the LTP on the IMS signal were investigated. The positive reactant ions generated by the LTP ionization source were similar to those created in a corona discharge ionization source, where the proton clusters ((H(2)O)(n)H(+)) are the most abundant reactant ion, and in the negative mode, in addition to a saturated electron peak, several negative reactant ions (e.g., NO(x)(-)) were observed too. These reactant ions subsequently ionized the gaseous samples directly and liquids or solids after evaporation by plasma desorption. The ion mobility spectra of a few selected compounds, including explosives, drugs, and amines, were obtained to evaluate the new ionization source in positive and negative modes, and the reduced mobility values (K(0)) of the originated ions were calculated. Furthermore, the method has also been applied to obtain the figures of merit for acetaminophen as a test compound. The results obtained are promising enough to ensure the use of LTP as a desorption/ionization source in IMS for analytical applications.  相似文献   

10.
The analysis of intact glycopeptides by mass spectrometry is challenging due to the numerous possibilities for isomerization, both within the attached glycan and the location of the modification on the peptide backbone. Here, we demonstrate that high field asymmetric wave ion mobility spectrometry (FAIMS), also known as differential ion mobility, is able to separate isomeric O-linked glycopeptides that have identical sequences but differing sites of glycosylation. Two glycopeptides from the glycoprotein mucin 5AC, GT(GalNAc)TPSPVPTTSTTSAP and GTTPSPVPTTST(GalNAc)TSAP (where GalNAc is O-linked N-acetylgalactosamine), were shown to coelute following reversed-phase liquid chromatography. However, FAIMS analysis of the glycopeptides revealed that the compensation voltage ranges in which the peptides were transmitted differed. Thus, it is possible at certain compensation voltages to completely separate the glycopeptides. Separation of the glycopeptides was confirmed by unique reporter ions produced by supplemental activation electron transfer dissociation mass spectrometry. These fragments also enable localization of the site of glycosylation. The results suggest that glycan position plays a key role in determining gas-phase glycopeptide structure and have implications for the application of FAIMS in glycoproteomics.  相似文献   

11.
Positive and negative thermal ionization ion mobility spectra (TI-IMS) of some sodium and potassium halides are reported here. The data provide the first measurement of the thermal ionization ion mobility spectrometry of inorganic compounds. A thin Nichrome filament was used as a thermionic ionization source. Sample was directly deposited on the filament, where it was heated and ionized. Each salt produced a different ion mobility pattern, but all sodium salts spectra were common in their first peak. This peak differs from the common peak observed in the spectra of potassium salts. The drift time of the second peak in all spectra was found to be linearly dependent on the size of the counteranion of the salt. Negative thermal ionization ion mobility spectra of alkali halides were also observed. An alkali halide salt (MX), in general, produced its own anion as well as some heavier ions that are thought to be hydrated X- (MX)n species. The capability of the method in quantitative analysis was demonstrated by measuring potassium impurity in sodium bromide. A detection limit of 0.01% K+ in NaBr and a linear rage of 3 orders of magnitude were obtained. The results from this study suggest that TI-IMS has potential as a field technique for the detection of some elements in samples.  相似文献   

12.
The utility of ion mobility spectrometry (IMS) for separation of mixtures and structural characterization of ions has been demonstrated extensively, including in biological and nanoscience contexts. A major attraction of IMS is its speed, several orders of magnitude greater than that of condensed-phase separations. Nonetheless, IMS combined with mass spectrometry (MS) has remained a niche technique, substantially because of limited sensitivity resulting from ion losses at the IMS-MS junction. We have developed a new electrospray ionization (ESI)-IMS-QTOF MS instrument that incorporates electrodynamic ion funnels at both front ESI-IMS and rear IMS-QTOF interfaces. The front funnel is of the novel "hourglass" design that efficiently accumulates ions and pulses them into the IMS drift tube. Even for drift tubes of 2-m length, ion transmission through IMS and on to QTOF is essentially lossless across the range of ion masses relevant to most applications. The rf ion focusing at the IMS terminus does not degrade IMS resolving power, which exceeds 100 (for singly charged ions) and is close to the theoretical limit. The overall sensitivity of the present ESI-IMS-MS system is comparable to that of commercial ESI-MS, which should make IMS-MS suitable for analyses of complex mixtures with ultrahigh sensitivity and exceptional throughput.  相似文献   

13.
Nanospray desorption electrospray ionization (nano-DESI) combined with high-resolution mass spectrometry was used for the first time for the analysis of the polar constituents of liquid petroleum crude oil samples. The analysis was performed in both positive and negative ionization modes using three solvents, one of which (acetonitrile/toluene mixture) is commonly used in petroleomics studies while two other polar solvents (acetonitrile/water and methanol/water mixtures) are generally not compatible with petroleum characterization using mass spectrometry. The results demonstrate that nano-DESI analysis efficiently ionizes petroleum constituents soluble in a particular solvent. When acetonitrile/toluene is used as a solvent, nano-DESI generates electrospray-like spectra. In contrast, strikingly different spectra were obtained using acetonitrile/water and methanol/water. Comparison with the literature data indicates that these solvents selectively extract water-soluble constituents of the crude oil. Water-soluble compounds are predominantly observed as sodium adducts in nano-DESI spectra indicating that addition of sodium to the solvent may be a viable approach for efficient ionization of water-soluble crude oil constituents. Nano-DESI enables rapid screening of different classes of compounds in crude oil samples based on their solubility in solvents that are rarely used for petroleum characterization providing better coverage of the crude oil composition as compared to electrospray ionization (ESI). It also enables rapid characterization of water-soluble components of petroleum samples that is difficult to perform using traditional approaches.  相似文献   

14.
Localization of the modification sites on peptides is challenging, particularly when multiple modifications or mixtures of localization isomers (variants) are involved. Such variants commonly coelute in liquid chromatography and may be undistinguishable in tandem mass spectrometry (MS/MS) for lack of unique fragments. Here, we have resolved the variants of singly and doubly phosphorylated peptides employing drift tube ion mobility spectrometry (IMS) coupled to time-of-flight mass spectrometry. Even with a moderate IMS resolving power of ~80-100, substantial separation was achieved for both 2+ and 3+ ions normally generated by electrospray ionization, including for the variants indistinguishable by MS/MS. Variants often exhibit a distribution of 3-D conformers, which can be adjusted for optimum IMS separation by prior field heating of ions in a funnel trap. The peak assignments were confirmed using MS/MS after IMS separation, but known species could be identified using just the ion mobility "tag". Avoiding the MS/MS step lowers the detection limit of localization variants to <100 amol, an order of magnitude better than that provided by electron transfer dissociation in an Orbitrap MS.  相似文献   

15.
A major limitation of mass spectrometry-based proteomics is inefficient and differential ionization during electrospray ionization (ESI). This leads to problems such as increased limits of detection and incomplete sequence coverage of proteins. Incomplete sequence coverage is especially problematic for analyses that require the detection and identification of specific peptides from a protein, such as the analysis of post-translational modifications. We describe here the development and use of aldehyde-based chemistry for the alkylation of peptide primary amines to increase peptide hydrophobicity, providing increased ionization efficiency and concomitant signal enhancement. When employed to modify the peptide products of protein tryptic digests, increased sequence coverage is obtained from combined modified and unmodified digests. To evaluate the utility of alkylation of peptides for selected reaction monitoring (SRM) assays, we alkylated a peptide from the protein Oct4, known to play a role in regulating stem cell differentiation. Increased chromatographic retention and ionization efficiency is observed for the alkylated Oct4 peptide compared to its unmodified form.  相似文献   

16.
Our aim in this investigation was to demonstrate the potential of the high-resolution electrospray ionization ion mobility spectrometry (ESI-IMS) technique as an analytical separation tool in analyzing biomolecular mixtures to pursue astrobiological objectives of searching for the chemical signatures of life during an in-situ exploration of solar system bodies. Because amino acids represent the basic building blocks of life, we used common amino acids to conduct the first part of our investigation, which is being reported here, to demonstrate the feasibility of using the ESI-IMS technique for detection of the chemical signatures of life. The ion mobilities of common amino acids were determined by electrospray ionization ion mobility spectrometry using three different drift gases (N2, Ar, and CO2). We demonstrated that the selectivity can be vastly improved in ion mobility spectroscopy (IMS) in detecting organic molecules by using different drift gases. When a judicial choice of drift gas is made, a vastly improved separation of two different amino acid ions resulted. It was found that each of the studied amino acids could be uniquely identified from the others, with the exception of alanine and glycine, which were never separable by more then 0.1 ms. This unique identification is a result of the different polarizabilities of the various drift gases. In addition, a better separation was achieved by changing the drift voltage in successive experimental runs without significantly degrading the resolution. We also report the result of our analysis of liquid samples containing mixtures of amino acids.  相似文献   

17.
High-field asymmetric waveform ion mobility spectrometry (FAIMS) is a new technique that separates gas-phase ions at atmospheric pressure (760 Torr) and room temperature. A FAIMS instrument acts as an ion filter and can be set to continuously transmit one type of ion. Despite the stringent requirement for a flow of clean, dry gas in the FAIMS analyzer region, a method of coupling electrospray to FAIMS has been developed. The identity of the electrospray ions separated by FAIMS was determined using mass spectrometry (FAIMS-MS). The theory of FAIMS is discussed, and electrospray FAIMS-MS spectra of several compounds in modes P1, P2, N1, and N2 are presented. Ions appearing in P1 and N1 modes tend to have mobilities that increase as a function of increasing electric field strength, whereas ions appearing in P2 and N2 modes tend to have mobilities that decrease. In general, low-mass ions are focused in P1 and N1 modes, whereas larger ions (e.g., proteins) are focused in P2 and N2 modes. Short-chain peptides, (Gly)(n) where n = 1-6, are shown to cross over from P1 mode into P2 mode as the chain length increases. The removal of the low-mass solvent cluster ions, combined with a reduction of the background noise in electrospray FAIMS-MS, results in an improved signal-to-noise ratio for mass spectra of larger ions (e.g., cyctochrome c) when compared with conventional electrospray-MS. Preliminary results also suggest that various charge states of cytochrome c can be distinguished by FAIMS, implying that the ion mobility of these species at high electric field strength is sensitive to the structure of the protein ion. The linearity of response of electrospray FAIMS-MS was investigated using leucine enkephalin and shows the calibration curve to be linear for ~3 orders of magnitude.  相似文献   

18.
The rapid increase in amphetamine abuse for recreational purposes has created a need for fast analysis and detection methodologies. For the first time, we show the separation of six amphetamines by ESI-IMS/MS. A complete analysis can be performed in 70 s, which is faster than traditional chromatographic techniques. In addition, ESI-IMS/MS was found to provide low detection limits for the six compounds (15.4 ppb for ethylamphetamine). Charge competition between amphetamines was found to occur at high amphetamine concentrations. The degree of preferential ionization was dependent on the functional group placed on the amine. Both one-analyte and two-analyte calibration curves were evaluated on the basis of the ion evaporation model. Evaporation rates were determined for the six amphetamines, and the rates were correlated with the degree of selective ionization. Evaluation of three typical ESI solvent compositions showed that the addition of a modifier (acetic acid and formic acid) enhanced the degree of preferential ionization for some amphetamines and increased the effect of charge competition. The solvent studies show the complexity of ESI and provide possible strategies for altering the amount of charge competition between analytes. Overall, ESI-IMS/MS appears to be a promising technique because of its sensitivity and rapid separation times for the amphetamines in aqueous samples; however, further research employing biological samples is required before it can be recommended as a mainstream technique.  相似文献   

19.
Enhanced charging, or supercharging, of analytes in electrospray ionization mass spectrometry (ESI MS) facilitates high resolution MS by reducing an ion mass-to-charge (m/z) ratio, increasing tandem mass spectrometry (MS/MS) efficiency. ESI MS supercharging is usually achieved by adding a supercharging reagent to the electrospray solution. Addition of these supercharging reagents to the mobile phase in liquid chromatography (LC)-MS/MS increases the average charge of enzymatically derived peptides and improves peptide and protein identification in large-scale bottom-up proteomics applications but disrupts chromatographic separation. Here, we demonstrate the average charge state of selected peptides and proteins increases by introducing the supercharging reagents directly into the ESI Taylor cone (in-spray supercharging) using a dual-sprayer ESI microchip. The results are comparable to those obtained by the addition of supercharging reagents directly into the analyte solution or LC mobile phase. Therefore, supercharging reaction can be accomplished on a time-scale of ion liberation from a droplet in the ESI ion source.  相似文献   

20.
Peng Y  Zhang S  Gong X  Ma X  Yang C  Zhang X 《Analytical chemistry》2011,83(23):8863-8866
A novel ionization device for controlling the charge states of peptides based on an inductive elecrospray ionization technique was developed. This ion source keeps the major capabilities of electrospray ionization (ESI) which is compatible with liquid separation techniques (such as liquid chromatography (LC) and capillary electrophoresis (CE)) and can be potentially used to control the charge states of peptides accurately by simply varying the AC voltage applied. In comparison with conventional ESI, inductive ESI successfully simplifies the mass spectrum by reducing the charge states of peptide to a singly charged one, as well as eliminating the adduct ions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号