首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
For decades, bridge slabs have been troubled by the corrosion of steel reinforcement. The unique corrosion resistance of glass fiber-reinforced polymer (GFRP) bars makes them a promising alternative to steel bars. Experiments have been conducted to investigate the bond performance of GFRP reinforced concrete under constant amplitude cyclic fatigue loading. Each specimen was an identical length beam with a single GFRP bar at the bottom, intended to simulate a transverse strip of a typical bridge deck slab. The crack growth was monitored for specimens of different widths, simulating different transverse reinforcement spacings. Up to 2?million?cycles of cyclic loads were applied at 100% typical service load levels. No fatigue failure was encountered in the testing. The effects of moderate overloads were also investigated.  相似文献   

2.
In the last decade, noncorrodible fiber-reinforced polymer (FRP) reinforcing bars have been increasingly used as the main reinforcement for concrete structures in harsh environments. Also, owing to their lower cost compared with other types of FRP bars, glass-FRP (GFRP) bars are more attractive to the construction industry, especially for implementation in bridge deck slabs. In North America, bridge deck slabs are exposed to severe environmental conditions, such as freeze-thaw action, in addition to traffic fatigue loads. Although the bond strength of GFRP bars has been proved to be satisfactory, their durability performance under the dual effects of fatigue-type loading and freeze-thaw action is still not well understood. Few experimental test data are available on the bond characteristics of FRP bars in concrete elements under different loading and environmental conditions. This research investigates the individual and combined effects of freeze-thaw cycles along with sustained axial load and fatigue loading on the bond characteristics of GFRP bars embedded in concrete. An FRP-reinforced concrete specimen was developed to apply axial-tension fatigue or sustained loads to GFRP bars within a concrete environment. A total of thirty-six test specimens was constructed and tested. The test parameters included bar diameter, concrete cover thickness, loading scheme, and environmental conditioning. After conditioning, each specimen was sectioned into two halves for pullout testing. Test results showed that fatigue load cycles resulted in approximately 50% loss in the bond strength of sand-coated GFRP bars to concrete, while freeze-thaw cycles enhanced their bond to concrete by approximately 40%. Larger concrete covers were found more important in cases of larger bar sizes simultaneously subjected to fatigue load and freeze-thaw cycles.  相似文献   

3.
This paper presents the results of an experimental study to investigate the role of each layer of reinforcement on the behavior of concrete bridge deck slabs reinforced with fiber-reinforced polymer (FRP) bars. Four full-scale concrete deck slabs of 3,000?mm length by 2,500?mm width and 200?mm depth were constructed and tested in the laboratory. One deck slab was reinforced with top and bottom mats of glass FRP bars. Two deck slabs had only a bottom reinforcement mat with different reinforcement ratios in the longitudinal direction, while the remaining deck slab was constructed with plain concrete without any reinforcement. The deck slabs were supported on two steel girders spaced at 2,000?mm center to center and were tested to failure under a central concentrated load. The three reinforced concrete slabs had very similar behavior and failed in punching shear mode at relatively high load levels, whereas the unreinforced slab behaved differently and failed at a very low load level. The experimental punching capacities of the reinforced slabs were compared to the theoretical predictions provided by ACI 318-05, ACI 440.1R-06, and a model proposed by the writers. The tests on the four deck slabs showed that the bottom transverse reinforcement layer has the major influence on the behavior and capacity of the tested slabs. In addition, the ACI 318-05 design method slightly overestimated the punching shear strength of the tested slabs. The ACI 440.1R-06 design method yielded very conservative predictions whereas the proposed method provided reasonable yet conservative predictions.  相似文献   

4.
Recently, there has been a rapid increase in using noncorrosive fiber-reinforced polymers (FRP) reinforcing bars as alternative reinforcement for bridge deck slabs, especially those in harsh environments. A new two-span girder type bridge, Cookshire-Eaton Bridge (located in the municipality of Cookshire, Quebec, Canada), was constructed with a total length of 52.08 m over two equal spans. The deck was a 200-mm-thick concrete slab continuous over four spans of 2.70 m between girders with an overhang of 1.40 m on each side. One full span of the bridge was totally reinforced using glass fiber-reinforced polymer (GFRP) bars, while the other span was reinforced with galvanized steel bars. The bridge deck was well instrumented at critical locations for internal temperature and strain data collection using fiber optic sensors. The bridge was tested for service performance using calibrated truckloads as specified by the Canadian Highway Bridge Design Code. The construction procedure and field test results under actual service conditions revealed that GFRP rebar provides very competitive performance in comparison to steel.  相似文献   

5.
Fiber-reinforced polymer (FRP) composite bridge deck panels are high-strength, corrosion resistant, weather resistant, etc., making them attractive for use in new construction or retrofit of existing bridges. This study evaluated the force-deformation responses of FRP composite bridge deck panels under AASHTO MS 22.5 (HS25) truck wheel load and up to failure. Tests were conducted on 16 FRP composite deck panels and four reinforced concrete conventional deck panels. The test results of FRP composite deck panels were compared with the flexural, shear, and deflection performance criteria per Ohio Department of Transportation specifications, and with the test results of reinforced concrete deck panels. The flexural and shear rigidities of FRP composite deck panels were calculated. The response of all panels under service load, factored load, cyclic loading, and the mode of failure were reported. The tested bridge deck panels satisfied the performance criteria. The safety factor against failure varies from 3 to 8.  相似文献   

6.
In addition to their high strength and light weight, fiber-reinforced polymer (FRP) composite reinforcing bars offer corrosion resistance, making them a promising alternative to traditional steel reinforcing bars in concrete bridge decks. FRP reinforcement has been used in several bridge decks recently constructed in North America. The Morristown Bridge, which is located in Vermont, United States, is a single span steel girder bridge with integral abutments spanning 43.90 m. The deck is a 230 mm thick concrete continuous slab over girders spaced at 2.36 m. The entire concrete deck slab was reinforced with glass FRP (GFRP) bars in two identical layers at the top and the bottom. The bridge is well instrumented at critical locations for internal temperature and strain data collection with fiber-optic sensors. The bridge was tested for service performance using standard truck loads. The construction procedure and field test results under actual service conditions revealed that GFRP rebar provides very good and promising performance.  相似文献   

7.
This study examines the effects of one-dimensional fiber-reinforced polymer (FRP) composite rehabilitation systems on the flexural fatigue performance of reinforced concrete bridge girders. Eight 508?mm deep and 5.6?m long reinforced concrete T-beams, with and without bonded FRP reinforcement on their tensile surfaces, were tested with a concentrated load at midspan under constant amplitude cyclic loading. The objective of this investigation is to establish the effect that these repair systems have on the fatigue behavior and remaining life of the girders. Results indicate that the fatigue behavior of such retrofit beams is controlled by the fatigue behavior of the reinforcing steel. The fatigue life of a reinforced concrete beam can be increased by the application of an FRP retrofit, which relieves some of the stress carried by the steel. The observed increase in fatigue life, however, is limited by the quality of the bond between the carbon FRP and concrete substrate. Debonding, initiating at midspan and progressing to a support, is common and is driven partially by the crack distribution and shear deformations of the beam.  相似文献   

8.
This paper presents the results of an investigation of the monotonic and fatigue behavior of one-way and two-way reinforced concrete slabs strengthened with carbon fiber-reinforced polymer (CFRP) materials. The five one-way slab specimens were removed from a decommissioned bridge in South Carolina. Three of the slabs were retrofitted with CFRP strips bonded to their soffits and the other two served as unretrofit, control specimens. Of the five one-way slab specimens, one unretrofit and two retrofit slabs were tested monotonically until failure. The remaining two specimens, one unretrofit and one retrofit, were tested under cyclic (fatigue) loading until failure. In addition, six half-scale, two-way slab specimens were constructed to represent a full-scale prototype of a highway bridge deck designed using the empirical requirements of the AASHTO LRFD Bridge Design Manual. Of the six square slabs, two were unretrofitted and served as the control specimens, two were retrofitted using CFRP strips bonded to their soffits making a grid pattern, and two were retrofitted with a preformed CFRP grid material bonded to their soffit. Three slabs, one unretrofit, one CFRP strip, and one CFRP grid retrofitted, were tested monotonically until failure and the remaining three slabs were tested under cyclic (fatigue) loading until failure.  相似文献   

9.
Continuous concrete beams are structural elements commonly used in structures that might be exposed to extreme weather conditions and the application of deicing salts, such as bridge overpasses and parking garages. In such structures, reinforcing continuous concrete beams with the noncorrodible fiber-reinforced polymer (FRP) bars is beneficial to avoid steel corrosion. However, the linear-elastic behavior of FRP materials makes the ability of continuous beams to redistribute loads and moments questionable. A total of seven full-scale continuous concrete beams were tested to failure. Six beams were reinforced with glass fiber-reinforced polymer (GFRP) longitudinal bars, whereas one was reinforced with steel as control. The specimens have rectangular cross section of 200×300??mm and are continuous over two spans of 2,800?mm each. Both steel and GFRP stirrups were used as transverse reinforcement. The material, spacing, and amount of transverse reinforcement were the primary investigated parameters in this study. In addition, the experimental results were compared with the code equations to calculate the ultimate capacity. The experimental results showed that moment redistribution in FRP-reinforced continuous concrete beams is possible and is improved by increasing the amount of transverse reinforcement. Also, beams reinforced with GFRP stirrups illustrated similar performance compared with their steel-reinforced counterparts.  相似文献   

10.
The research presented in this paper evaluates the flexural performance of bridge deck panels reinforced with 2D fiber-reinforced polymer (FRP) grids. Two different FRP grids were investigated, one reinforced with a hybrid of glass and carbon fibers and a second grid reinforced with carbon fibers only. Laboratory measured load-deflection, load-strain (reinforcement and concrete), cracking, and failure behavior are presented in detail. Conclusions regarding failure mode, limit-state strength, serviceability, and deflection compatibility relative to AASHTO mandated criteria are reported. Test results indicate that bridge decks reinforced with FRP grids will be controlled by serviceability limit state and not limit-state ultimate strength. The low axial stiffness of FRP results in large service load flexural deflections and reduced shear strength. In as much as serviceability limits design, overreinforcement is recommended to control deflection violation. Consequently, limit-state flexural strength will be compression controlled for which reduced service stresses or ACI unified compression failure strength reduction factors are recommended.  相似文献   

11.
This paper evaluates the shear strength of one-way concrete slabs reinforced with different types of fiber-reinforced polymer (FRP) bars. A total of eight full-size slabs were constructed and tested. The slabs were 3,100?mm?long×?1,000?mm?wide×200?mm?deep. The test parameters were the type and size of FRP reinforcing bars and the reinforcement ratio. Five slabs were reinforced with glass FRP and three were reinforced with carbon FRP bars. The slabs were tested under four-point bending over a simply supported clear span of 2,500 mm and a shear span of 1,000 mm. All the test slabs failed in shear before reaching the design flexural capacity. The experimental shear strengths were compared with some theoretical predictions, including the JSCE recommendations, the CAN/CSA-S806-02 code, and the ACI 440.1R-03 design guidelines. The results indicated that the ACI 440.1R-03 design method for predicting the concrete shear strength of FRP slabs is very conservative. Better predictions were obtained by both the CAN/CSA-S806-02 code and the JSCE design recommendations.  相似文献   

12.
A full-scale model of a bridge deck slab isotropically reinforced with 0.3% fiber-reinforced plastic reinforcement (FRP) was tested. The 6 m long slab of 185 mm thickness had two 2 m spans and 1 m cantilevers on both sides. The slab was first loaded monotonically to crack the concrete. Then it was loaded cyclically in three stages of 4 million cycles each at a frequency of 5 Hz, with the load varying between 0 and 100 kN in the first two stages and between 0 and 125 kN in the last. Finally, it was loaded monotonically to failure. Constructability of the slab with the FRP reinforcement was found satisfactory. The cyclic load test shows that deflections and stresses are small, and the degradation indicated by increases in deflections and stresses after 4 million cycles of overloading by 25% is very small. The ultimate load capacity of the slab was at least five times the maximum wheel load of 100 kN, and the failure mode was punching shear. Long-term performance of FRP reinforcement under the combined effect of exposure to the chemical environment and loading needs to be studied to evaluate durability, and hence cost-effectiveness, of FRP reinforcement in bridge decks.  相似文献   

13.
The Val-Alain Bridge, located in the Municipality of Val-Alain on Highway 20 East, crosses over Henri River in Québec, Canada. The bridge is a slab-on-girder type with a skew angle of 20° over a single span of 49.89?m and a total width of 12.57?m. The bridge has four simply supported steel girders spaced at 3,145?mm. The deck slab is a 225-mm-thick concrete slab, with semi-integral abutments, continuous over the steel girders with an overhang of 1,570?mm on each side. The concrete deck slab and the bridge barriers were reinforced with glass fiber reinforced polymer (GFRP) reinforcing bars utilizing high-performance concrete. The Val-Alain Bridge is the Canada’s first concrete bridge deck totally reinforced with GFRP reinforcing bars. Using such nonmetallic reinforcement in combination with high-performance concrete leads to an expected service life of more than 75?years. The bridge is well instrumented with electrical resistance strain gauges and fiber-optic sensors at critical locations to record internal strain data. Also, the bridge was tested for service performance using calibrated truckloads. Design concepts, construction details, and results of the first series of live load field tests are presented.  相似文献   

14.
Continuous concrete beams are commonly used elements in structures such as parking garages and overpasses, which might be exposed to extreme weather conditions and the application of deicing salts. The use of the fiber-reinforced polymers (FRP) bars having no expansive corrosion product in these types of structures has become a viable alternative to steel bars to overcome the steel-corrosion problems. However, the ability of FRP materials to redistribute loads and moments in continuous beams is questionable due to the linear-elastic behavior of such materials up to failure. This paper presents the experimental results of four reinforced concrete beams with rectangular cross section of 200×300?mm continuous over two spans of 2,800 mm each. The material and the amount of longitudinal reinforcement were the main investigated parameters in this study. Two beams were reinforced with glass FRP (GFRP) bars in to different configurations while one beam was reinforced with carbon FRP bars. A steel-reinforced continuous concrete beam was also tested to compare the results. The experimental results showed that moment redistribution in FRP-reinforced continuous concrete beams is possible if the reinforcement configuration is chosen properly. Increasing the GFRP reinforcement at the midspan section compared to middle support section had positive effects on reducing midspan deflections and improving load capacity. The test results were compared to the available design models and FRP codes. It was concluded that the Canadian Standards Association Code (CSA/S806-02) could reasonably predict the failure load of the tested beams; however, it fails to predict the failure location.  相似文献   

15.
This paper presents the results of an experimental and analytical study of the fatigue performance of corroded reinforced concrete (RC) beams repaired with fiber-reinforced polymer (FRP) sheets. Ten RC beam specimens (152×254×3,200?mm) were constructed. One specimen was neither strengthened nor corroded to serve as a reference; three specimens were corroded and not repaired; another three specimens were corroded and repaired with U-shaped glass FRP sheets that wrapped the cross section of the specimen; and the remaining three specimens were corroded and repaired with U-shaped glass FRP sheets for wrapping and carbon-fiber-reinforced polymer (CFRP) sheets for flexural strengthening. The FRP sheets were applied after the main reinforcing bars were corroded to an average mass loss of 5.5%. Following FRP repair, some specimens were tested immediately to failure, while the other repaired specimens were subjected to further corrosion before being tested to failure to investigate their postrepair (long-term) performance. Reinforcement steel pitting due to corrosion reduced the fatigue life significantly. The FRP wrapping had no significant effect on the fatigue performance, while using CFRP sheets for flexural strengthening enhanced the fatigue performance significantly. The fatigue results were compared to smooth specimen fatigue data to estimate an equivalent fatigue notch factor for the main reinforcing bars of the tested specimens.  相似文献   

16.
Fiber-reinforced polymers (FRP) are becoming more widely used for repair and strengthening of conventionally reinforced concrete (RC) bridge members. Once repaired, the member may be exposed to millions of load cycles during its service life. The anticipated life of FRP repairs for shear strengthening of bridge members under repeated service loads is uncertain. Field and laboratory tests of FRP-repaired RC deck girders were performed to evaluate high-cycle fatigue behavior. An in-service 1950s vintage RC deck-girder bridge repaired with externally bonded carbon fiber laminates for shear strengthening was inspected and instrumented, and FRP strain data were collected under ambient traffic conditions. In addition, three full-size girder specimens repaired with bonded carbon fiber laminate for shear strengthening were tested in the laboratory under repeated loads and compared with two unfatigued specimens. Results indicated relatively small in situ FRP strains, laboratory fatigue loading produced localized debonding along the FRP termination locations at the stem-deck interface, and the fatigue loading did not significantly alter the ultimate shear capacity of the specimens.  相似文献   

17.
The design and construction of bridge systems with long-term durability and low maintenance requirements is a significant challenge for bridge engineers. One possible solution to this challenge could be through the use of new materials, e.g., fiber-reinforced polymer (FRP) composites, with traditional materials that are arranged as an innovative hybrid structural system where the FRP serves as a load-carrying constituent and a protective cover for the concrete. This paper presents the results of an experimental investigation designed to evaluate the performance of a 3/4 scale hybrid FRP-concrete (HFRPC) bridge deck and composite connection under sustained and repeated (fatigue) loading. In addition, following the sustained-load and fatigue portions of the experimental study, destructive testing was performed to determine the first strength-based limit state of the hybrid deck. Results from the sustained-load and fatigue testing suggest that the HFRPC deck system might be a viable alternative to traditional cast-in-place reinforced concrete decks showing no global creep behavior and no degradation in stiffness or composite action between the deck and steel girders after 2 million cycles of dynamic loading with a peak load of 1.26 times the scaled tandem load (TL). Furthermore, the ultimate strength test showed that the deck failed prior to the global superstructure at a load approximately six times the scaled TL.  相似文献   

18.
This study investigates the shear behavior of concrete beams reinforced with fiber-reinforced polymer (FRP) reinforcement. Six beams were subjected to two successive phases of testing. Half of the beams were reinforced in flexure with conventional steel reinforcement, while the other half were reinforced with glass fiber bars. Different shear span to depth ratios, ranging from 1.1 to 3.3, were analyzed in order to study the variation in the shear behavior of beams characterized by different types of shear failure. No shear reinforcement was provided in the first phase of testing, while in the second phase, just enough glass and carbon shear reinforcement was provided to enable failure due to shear. The results of these tests are presented and compared to predictions according to the design recommendations proposed by the ACI and the Institution of Structural Engineers, U.K. The results of this study show that these approaches, which are based on modifications of equations derived for steel reinforcement, underestimate the contribution of the concrete and the shear reinforcement to the total shear capacity of FRP RC beams. It is shown that both approaches can be modified to become less conservative.  相似文献   

19.
The use of fiber-reinforced polymer (FRP) reinforcement is a practical alternative to conventional steel bars in concrete bridge decks, safety appurtenances, and connections thereof, as it eliminates corrosion of the steel reinforcement. Due to their tailorability and light weight, FRP materials also lend themselves to the development of prefabricated systems that improve constructability and speed of installation. These advantages have been demonstrated in the construction of an off-system bridge, where prefabricated cages of glass FRP bars were used for the open-post railings. This paper presents the results of full-scale static tests on two candidate post–deck connections to assess compliance with strength criteria at the component (connection) level, as mandated by the AASHTO Standard Specifications, which were used to design the bridge. Strength and stiffness until failure are shown to be accurately predictable. Structural adequacy was then studied at the system (post-and-beam) level by numerically modeling the nonlinear response of the railing under equivalent static transverse load, pursuant to well-established structural analysis principles of FRP RC, and consistent with the AASHTO LRFD Bridge Design Specifications. As moment redistribution cannot be accounted for in the analysis and design of indeterminate FRP RC structures, a methodology that imposes equilibrium and compatibility conditions was implemented in lieu of yield line analysis. Transverse strength and failure modes are determined and discussed on the basis of specification mandated requirements.  相似文献   

20.
A method to utilize fiber composites for rapid repair of earthquake damaged flared columns was developed. Two 0.4-scale reinforced concrete columns that had been tested to failure in previous research were used. Both columns had been subjected to slow cyclic loads and had failed due to low-cycle fatigue of the longitudinal bars. To repair the columns, the damaged concrete in and around the plastic hinge was removed and the steel bars were straightened. Low-shrinkage, high-strength concrete grout was placed in the column afterward. The broken longitudinal bars were not replaced. Rather, glass and carbon fiber reinforced polymer (FRP) sheets with fibers running in the axial direction of the column were added to provide flexural strength to the columns. Additionally, glass FRP sheets with horizontal fibers were attached on the column to provide confinement and shear strength. Cyclic tests of the repaired columns indicated that the method to restore the strength was effective. Analysis using conventional constitutive relationships led to a close estimate of the lateral load response of the models.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号