首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
地下空间氡的产生机理及通风控制   总被引:1,自引:0,他引:1  
本文建立了土壤和建材的氡析出模型,在充分考虑各个影响因素的前提下,推导出了土壤和建材的表面析氡率公式,并依据此公式,进而推导出了室内氡浓度与通风换气效率的关系式。应用以上公式,对一典型的地下空间模型进行了计算,结果表明:地下空间氡的主要来源是土壤氡气的逸出,约占总析氡量的70豫~90豫;在较高的氡浓度状态下,室内氡浓度对通风十分敏感,增大地下空间的通风换气率,会使空气氡浓度大幅度的降低。因此,若按照地下空间的标准新风量进行设计,控制室内氡水平在400Bq/m3以内是很容易的,但是若要控制室内氡水平在200Bq/m3以内,则至少需要25.2m3/h的人均新风量,考虑新风不能得到完全利用,所需引入的室外新风量至少为31.5m3/h(以地下商场为例)。  相似文献   

2.
Guangdong is one of the provinces that have most hot springs in China, and many hotels have been set up near hot springs, with spring water introduced into the bath inside each hotel room for hot spring bathing to attract tourists. In the present study, we measured radon in indoor and outdoor air, as well as in hot spring waters, in four hot spring hotels in Guangdong by using NR-667A (III) continuous radon detector. Radon concentrations ranged 53.4-292.5 Bq L(-1) in the hot spring water and 17.2-190.9 Bq m(-3) in outdoor air. Soil gas intrusion, indoor hot spring water use and inefficient ventilation all contributed to the elevated indoor radon levels in the hotel rooms. From the variation of radon levels in closed unoccupied hotel rooms, soil gas intrusion was found to be a very important source of indoor radon in hotel rooms with floors in contact with soils. When there was spring water bathing in the bathes, average radon levels were 10.9-813% higher in the hotel rooms and 13.8-489% higher in bathes compared to their corresponding average levels when there was no spring water use. Spring water use in the hotel rooms had radon transfer coefficients from 1.6x10(-4) to 5.0x10(-3). Radon in some hotel rooms maintained in concentrations much higher than guideline levels might thus have potential health risks to the hotel workers, and technical and management measures should be taken to lower their exposure of radon through inhalation.  相似文献   

3.
本文采用自动记录仪,对厦门某海滨住宅夏季自然通风与室内热环境进行实测。根据测得的自然通风时段,分析了自然通风对房间风速及室内热环境的影响。主要结论有:(1)在自然通风条件下,房间白天室内风速均值及波动值较夜间大。(2)房间在自然通风时段,室内气温均值略低于室外,室内气温波动明显低于室外且各房间气温波动差别不大;房间在非自然通风时段,室内气温均值与室外气温相当,室温变化相当平缓。(3)无论是自然通风还是非自然通风,房间的黑球温度与室内空气温度差别很小。(4)当房间处于非自然通风状态时,室内热环境总是处于"不可接受"水平,当房间处于自然通风状态时,其室内热环境几乎全时段达到"可接受"水平,且有的房间在某些时段可达到"热舒适"水平。  相似文献   

4.
We studied the effect of ventilation and air filtration systems on indoor air quality in a children's day-care center in Finland. Ambient air nitrogen oxides (NO, NO2) and particles (TSP, PM10) were simultaneously measured outdoors and indoors with automatic nitrogen oxide analyzers and dust monitoring. Without filtration nitrogen oxides and particulate matter generated by nearby motor traffic penetrated readily indoors. With chemical filtration 50-70% of nitrogen oxides could be removed. Mechanical ventilation and filtration also reduced indoor particle levels. During holidays and weekends when there was no opening of doors and windows and no particle-generating activity indoors, the indoor particle level was reduced to less than 10% of the outdoor level. At times when outdoor particle concentrations were high during weekdays, the indoor level was about 25% of the outdoor level. Thus, the possible adverse health effects of nitrogen oxides and particles indoors could be countered by efficient filtration. We also showed that inclusion of heat recovery equipment can make new ventilation installations economical.  相似文献   

5.
Abstract To investigate the effect of ventilation on indoor radon (222Rn), simultaneous measurements of radon concentrations and air change rates were made in 117 Danish naturally ventilated slab-on-grade houses built during the period 1984–1989. Radon measurements (based on CR-39 alpha-track detectors) and air change rate measurements (based on the perfluorocarbon tracer technique; PFT) were in the ranges 12–620 Bq m?3 and 0.16?0.96 h?1, respectively. Estimates of radon entry rates on the basis of such time-averaged results are presented and the associated uncertainty is discussed. It was found that differences in radon concentrations from one house to another are primarily caused by differences in radon entry rates whereas differences in air change rates are much less important (accounting for only 80,0% of the house-to-house variation). In spite of the large house-to-house variability of radon entry rates it was demonstrated, however, that natural ventilation does have a significant effect on the indoor radon concentration. Most importantly, it was found that the group of houses with an air change rate above the required level of 0.5 h?1 on average had an indoor radon concentration that was only 50% (0.5±0.1) of that of the group of houses with air change rates below 0.5 h?1. The reducing effect of increased natural ventilation on the indoor radon concentration was found to be due mainly to dilution of indoor air. No effect could be seen regarding reduced radon entry rates.  相似文献   

6.
《Building and Environment》2005,40(11):1566-1571
Based on an averaging technique, a methodology has been established to estimate an effective radon emanation factor M for residential premises. The model shows that the new term M and the ventilation rate are the essential parameters in estimating the level of indoor radon. M includes two components: the radon emanation rates of internal surface materials and the ratio of surface areas of applicable materials to premises volume. The value of M can be determined from on-site measurements. Different ventilation modes of a sampled residential unit during daytime and nighttime, with air conditioner on, window-open, and window-closed were included in site measurements. Each ventilation mode was measured twice during daytime and twice at night. During the investigation, air exchange rate, and indoor and outdoor radon levels were monitored simultaneously. The results of measurements were then used to verify the model. The value of M was found to be 31.7 Bq m−3 h−1. The model is valid if the air exchange rate is larger than 0.2 h−1.  相似文献   

7.
The objective of this study was to quantify the influence of ventilation systems on indoor particle concentrations in residential buildings. Fifteen occupied, single‐family apartments were selected from three sites. The three sites have three different ventilation systems: unbalanced mechanical ventilation, balanced mechanical ventilation, and natural ventilation. Field measurements were conducted between April and June 2012, when outdoor air temperatures were comfortable. Number concentrations of particles, PM2.5 and CO2, were continuously measured both outdoors and indoors. In the apartments with natural ventilation, I/O ratios of particle number concentrations ranged from 0.56 to 0.72 for submicron particles, and from 0.25 to 0.60 for particles larger than 1.0 μm. The daily average indoor particle concentration decreased to 50% below the outdoor level for submicron particles and 25% below the outdoor level for fine particles, when the apartments were mechanically ventilated. The two mechanical ventilation systems reduced the I/O ratios by 26% for submicron particles and 65% for fine particles compared with the natural ventilation. These results showed that mechanical ventilation can reduce exposure to outdoor particles in residential buildings.  相似文献   

8.
Janssen MP 《Indoor air》2003,13(2):118-127
Indoor radon concentrations were estimated for various ventilation conditions, the differences being mainly related to the airtightness of the dwelling and the ventilation behavior of its occupants. The estimations were aimed at describing the variation in air change rates and radon concentrations to be expected in the representative newly built Dutch dwellings and identifying the most important parameters determining air change rate and indoor radon concentration. The model estimations were compared with measurements. Most of the air was predicted to enter the model dwelling through leaks in the building shell, independent of the ventilation conditions of the dwelling. Opening the air inlets was shown to be an efficient way to increase infiltration and thus to decrease radon concentration. The effect of increasing the mechanical ventilation rate was considerably less than opening the air inlets. The mechanical ventilation sets the lower limit to the air change rate of the dwelling, and is effective in reducing the radon concentration when natural infiltration is low. Opening inside doors proved to be effective in preventing peak concentrations in poorly ventilated rooms. As the airtightness of newly built dwellings is still being improved, higher radon concentrations are to be expected in the near future and the effect of occupant behavior on indoor radon concentrations is likely to increase. According to the model estimations soil-borne radon played a moderate role, which is in line with measurements.  相似文献   

9.
Indoor exposure to air contaminants penetrating from the outdoor environment depends on a number of key processes and parameters such as the ventilation rate, the geometric characteristics of the indoor environment, the outdoor concentration and the indoor removal mechanisms. In this study two alternative methods are used, an analytical and a numerical one, in order to study the time lag and the reduction of the variances of the indoor concentrations, and to estimate the deposition rate of the air contaminants in the indoor environment employing both indoor and outdoor measurements of air contaminants. The analytical method is based on a solution of the mass balance equation involving an outdoor concentration pulse which varies sinusoidally with the time, while the numerical method involves the application of the MIAQ indoor air quality model assuming a triangular pulse. The ratio of the fluctuation of the indoor concentrations to the outdoor ones and the time lag were estimated for different values of the deposition velocity, the ventilation rate and the duration of the outdoor pulse. Results have showed that the time lag between the indoor and outdoor concentrations is inversely proportional to the deposition and ventilation rates, while is proportional to the duration of the outdoor pulse. The decrease of the ventilation and the deposition rate results in a rapid decrement of the variance ratio of indoor to outdoor concentrations and to an increment of the variance ratio, respectively. The methods presented here can be applied for gaseous species as well as for particulate matter. The nomograms and theoretical relationships that resulted from the simulation results and the analytical methods respectively were used in order to study indoor air phenomena. In particular they were used for the estimation of SO2 deposition rate. Implications of the studied parameters to exposure studies were estimated by calculating the ratio of the indoor exposure to the exposure outdoors. Limitations of the methods were explored by testing various scenarios which are usually met in the indoor environment. Strong indoor emissions, intense chemistry and varying ventilation rates (opening and closing of the windows) were found to radically influence the time lag and fluctuation ratios.  相似文献   

10.
通过实验,研究了家用水冷式空调的运行特性。探讨了室外环境温度、室外相对湿度、室内温度、室内负荷、室内显热比及冷却水流量等参数的变化对系统性能带来的影响,有助于进一步了解系统的运行规律,为产品的开发提供一定理论支持。  相似文献   

11.
Architects and engineers are beginning to consider a new dimension of indoor air: the structure and composition of airborne microbial communities. A first step in this emerging field is to understand the forces that shape the diversity of bioaerosols across space and time within the built environment. In an effort to elucidate the relative influences of three likely drivers of indoor bioaerosol diversity – variation in outdoor bioaerosols, ventilation strategy, and occupancy load – we conducted an intensive temporal study of indoor airborne bacterial communities in a high‐traffic university building with a hybrid HVAC (mechanically and naturally ventilated) system. Indoor air communities closely tracked outdoor air communities, but human‐associated bacterial genera were more than twice as abundant in indoor air compared with outdoor air. Ventilation had a demonstrated effect on indoor airborne bacterial community composition; changes in outdoor air communities were detected inside following a time lag associated with differing ventilation strategies relevant to modern building design. Our results indicate that both occupancy patterns and ventilation strategies are important for understanding airborne microbial community dynamics in the built environment.  相似文献   

12.
This study examines the influence of ventilation on chemical reactions among indoor pollutants. We have used a one compartment mass balance model to simulate unimolecular and bimolecular reactions occurring indoors. The initial modeling assumes steady-state conditions. However, at low air exchange rates, there may be insufficient time to achieve steady-state. Hence we have also modeled non steady-state scenarios. In the cases examined, the results demonstrate that the concentrations of products generated from reactions among indoor pollutants increase as the ventilation rate decreases. This is true for unimolecular and bimolecular reactions, regardless of whether the pollutants have indoor or outdoor sources. It is also true even when one of the pollutants has an outdoor concentration that displays large diurnal variations. We have supplemented the modeling studies with a series of experiments conducted in typical commercial offices. The reaction examined was that between ozone and limonene. The ozone was present as a consequence of outdoor-to-indoor transport while the limonene originated indoors. Results were obtained for low and high ventilation rates. Consistent with the modeling studies, the concentrations of monitored products were much larger at the lower ventilation rates (even though the ozone concentrations were lower). The potential for reactions among indoor pollutants to generate reactive and irritating products is an additional reason to maintain adequate ventilation in indoor environments.  相似文献   

13.
Yibin Chen 《Indoor air》1993,3(1):51-56
This paper presents the results of indoor radon surveys in the Sichuan province of China. The indoor radon concentrations found using scintillation or the two-filter method, ranged from 1.0 Bqm?3 to 170.2 Bqm?3. The arithmetic mean concentrations of indoor radon and its progeny were 17.8 Bqm?3 and 10.8 Bqm?3 EER (2.9 m WL), respectively. A seasonal pattern of the maximum in winter and the minimum in summer was observed for radon and its progeny concentrations. The annual effective dose equivalent resulting from indoor and outdoor inhalation of radon progeny totalled 0.93 mSv. Of the 109 million people living in Sichuan, 3000-6800 may die annually from lung cancer induced by the inhalation of radon progeny.  相似文献   

14.
Ventilation in Scandinavian buildings is commonly performed by means of a constant flow ventilation fan. By using a regulated fan, it is possible to make a seasonal adjustment of outdoor ventilation flow. Energy saving can be achieved by reducing the mechanical ventilation flow during the heating season, when natural ventilation driven by temperature differences between outdoor and indoor is relatively high. This ventilation principle has been called 'seasonally adapted ventilation (SAV)'. The aim was to study if a 25-30% reduction of outdoor ventilation flow during heating season influenced sick building syndrome (SBS) and the perception of the indoor environment. This was done in a 1-year cross-over intervention study in 44 subjects in a multi-family building. During the first heating season (November to April), one part of the building (A) got a reduced flow during the heating season [0.4-0.5 air exchanges per hour (ACH)] while the other part (B) had constant flow (0.5-0.8 ACH). The next heating season, part A got constant flow, while part B got reduced ventilation flow. Reduced ventilation increased the relative air humidity by 1-3% in the living room (mean 30-37% RH), 1-5% in the bathroom (mean 48-58% RH) during heating season. The room temperature increased 0.1-0.3 degrees C (mean 20.7-21.6 degrees C), mean carbon dioxide (CO2) concentration in the bedroom increased from 920 to 980 p.p.m. at reduced flow. The indoor air quality was perceived as poorer at reduced outdoor airflow, both in the bedroom and in the apartment as a whole. There was a significant increase of stuffy odor (P = 0.05) at reduced outdoor airflow and the indoor air quality was perceived as poorer, both in the bedroom (P = 0.03) and in the apartment as a whole (P = 0.04). No significant influence on SBS symptoms or specific perceptions such as odors, draught, temperature, air dryness or stuffy air could be detected. In conclusion, reducing the ventilation flow in dwellings to a level below the current Swedish ventilation standard (0.5 ACH) may cause a perception of impaired air quality. Technical measurements could only demonstrate a minor increase of indoor temperature, relative air humidity, and bedroom CO2 concentration. This illustrates that it is important to combine technical measurements with a longitudinal evaluation of occupant reactions, when evaluating energy-saving measures. PRACTICAL IMPLICATIONS: It is important to combine technical measurements with a longitudinal evaluation of occupant reactions, when evaluating energy-saving measures. Reduction of outdoor airflow in dwellings below the current ventilation standard of 0.5 ACH may lead to a perception of impaired air quality, despite only a minor increase of bedroom CO2-concentration.  相似文献   

15.
Yang W  Lee K  Chung M 《Indoor air》2004,14(2):105-111
Indoor air quality can be affected by indoor sources, ventilation, decay and outdoor levels. Although technologies exist to measure these factors, direct measurements are often difficult. The purpose of this study was to develop an alternative method to characterize indoor environmental factors by multiple indoor and outdoor measurements. Daily indoor and outdoor NO2 concentrations were measured for 30 consecutive days in 28 houses in Brisbane, Australia, and for 21 consecutive days in 37 houses in Seoul, Korea. Using a mass balance model and regression analysis, penetration factor (ventilation rate divided by the sum of ventilation rate and deposition constant) and source strength factor (source strength divided by the sum of ventilation rate and deposition constant) were calculated using multiple indoor and outdoor measurements. Subsequently, the ventilation rate and NO2 source strength were estimated. Geometric means of ventilation rate were 1.44 air change per hour (ACH) in Brisbane, assuming a residential NO2 deposition constant of 1.05/h, and 1.36 ACH in Seoul, with the measured residential NO2 deposition constant of 0.94/h. Source strengths of NO2 were 15.8 +/- 18.2 and 44.7 +/- 38.1 microg/m3/h in Brisbane and Seoul, respectively. In conclusion, indoor environmental factors were effectively characterized by this method using multiple indoor and outdoor measurements.  相似文献   

16.
More and more studies reported that there were insufficient ventilation and excessive CO_2 concentration in air-conditioned residential buildings, but few solutions were provided. This study investigates the overnight evolution of CO_2 concentration in air-conditioned residential buildings and then focuses mainly on the evaluation of three ventilation strategies, including overnight natural ventilation, short-term mechanical ventilation and short-term natural ventilation. On-site measurements were conducted in a typical residential bedroom in Hong Kong in September. The indoor and outdoor CO_2 concentration, air temperature and relative humidity as well as the outdoor wind speed during the measurements were analysed. Ventilation rates were calculated based on the time series of CO_2 concentration. This study confirms that additional ventilation is usually needed in air-conditioned residential buildings. Overnight natural ventilation with even a small opening is associated with excessive energy consumption and deteriorated indoor thermal environment. Short-term natural ventilation strategies are inefficient and uncontrollable. Compared to the best short-term natural ventilation strategy, a reasonably designed short-term mechanical ventilation strategy requires only a 41% of ventilation period to complete one full replacement of indoor air and to reach a lower indoor CO_2 concentration. Nighttime case studies and a theoretical analysis suggest that a few several-minute mechanical ventilation periods could potentially maintain an acceptable indoor air quality for a normal sleeping period of 8 h.  相似文献   

17.
新风对于稀释室内空气中的有害物质、改善室内环境有着重要的意义。新风量则是衡量新风的有效手段,目前不设独立新风系统的建筑室内新风量测量广泛采用CO_2示踪气体法。本文通过一系列实验探讨CO_2初始浓度、门窗开关方式、室外风速以及室内杂物对室内新风量检测结果的影响。实验结果表明CO_2初始浓度、门窗开关方式、室外风速、室内杂物这些因素均对新风量检测值均存在不同程度的影响,其中室外风速和室内有无杂物对新风量检测结果的影响最为明显。  相似文献   

18.
进行了夏季屋顶绿化对室内热环境影响的实验研究,结果表明:室内空气和维护结构内表面温度均有不同程度的降低,这是有利的;然而房间的相对湿度升高了,这是不利的;综合效果是人感到热改善为基本能接受;当热环境要求高时,仅靠屋顶绿化一个手段还达不到令人满意的效果.还必须采用其它手段比如夜间开窗通风,利用电风扇使室内产生一定的风速以及空调等的综合作用。  相似文献   

19.
Exposure to high concentrations of radon (222Rn) progeny produces lung cancer in both underground miners and experimentally-exposed laboratory animals. The goal of the study was to determine whether or not residential radon exposure exhibits a statistically significant association with lung cancer in a state with high residential radon concentrations. A population-based, case-control epidemiologic study was conducted examining the relationship between residential radon gas exposure and lung cancer in Iowa females who occupied their current home for at least 20 years. The study included 413 incident lung cancer cases and 614 age-frequency-matched controls. Participant information was obtained by a mailed-out questionnaire with face-to-face follow-up. Radon dosimetry assessment consisted of five components: (1) on-site residential assessment survey; (2) on-site radon measurements; (3) regional outdoor radon measurements; (4) assessment of subjects' exposure when in another building; and (5) linkage of historic subject mobility with residential, outdoor, and other building radon concentrations. Histologic review was performed for 96% of the cases. Approximately 60% of the basement radon concentrations and 30% of the first floor radon concentrations of study participants' homes exceeded the US Environmental Protection Agency action level of 150 Bq m(-3) (4 pCi l(-1)). Large areas of western Iowa had outdoor radon concentrations comparable to the national average indoor value of 55 Bq m(-3) (1.5 pCi l(-1)). Excess odds of 0.24 (95% CI = -0.05-0.92) and 0.49 (95% CI = 0.03-1.84) per 11 WLM(5-19) were calculated using the continuous radon exposure estimates for all cases and live cases, respectively. Slightly higher excess odds of 0.50 (95% CI = 0.004-1.80) and 0.83 (CI = 0.11-3.34) per 11 WLM(5-19) were noted for the categorical radon exposure estimates for all cases and the live cases. A positive association between cumulative radon gas exposure and lung cancer was demonstrated using both categorical and continuous analyses. The risk estimates obtained in this study indicate that cumulative radon exposure presents an important environmental health hazard.  相似文献   

20.
This study investigates the effectiveness of night ventilation technique for residential buildings in hot-humid climate of Malaysia. This paper firstly presents the results of a survey on usage patterns of windows and air-conditioners in typical Malaysian residential areas. Secondly, the effects of different natural ventilation strategies on indoor thermal environment for Malaysian terraced houses are evaluated based on the results of a full-scale field experiment. The results show that the majority of occupants tend to apply not night ventilation but daytime ventilation in Malaysian residential areas. It can be seen from the field experiment that night ventilation would provide better thermal comfort for occupants in Malaysian terraced houses compared with the other ventilation strategies in terms of operative temperature. However, when the evaporative heat loss of occupants is taken into account by using SET*, the night ventilation would not be the superior technique to the others in providing daytime thermal comfort mainly due to the high humidity conditions. Therefore, the indoor humidity control during the daytime such as by dehumidification would be needed when the night ventilation technique is applied to Malaysian terraced houses. Otherwise, full-day ventilation would be a better option compared with night ventilation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号