首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The scanning electron microscope (SEM) is usually operated with a beam voltage, V0, in the range of 10–30 kV, even though many early workers had suggested the use of lower voltages to increase topographic contrast and to reduce specimen charging and beam damage. The chief reason for this contradiction is poor instrumental performance when V0=1–3 kV, The problems include low source brightness, greater defocusing due to chromatic aberration greater sensitivity to stray fields, and difficulty in collecting the secondary electron signal. Responding to the needs of the semiconductor industry, which uses low V0 to reduce beam damage, considerable efforts have been made to overcome these problems. The resulting equipment has greatly improved performance at low kV and substantially removes the practical deterrents to operation in this mode. This paper reviews the advantages of low voltage operation, recent progress in instrumentation and describes a prototype instrument designed and built for optimum performance at 1 kV. Other limitations to high resolution topographic imaging such as surface contamination, the de-localized nature of the inelastic scattering event and radiation damage are also discussed.  相似文献   

2.
An electron detector containing channel electron multipliers was built and tested in the range of low‐voltage scanning electron microscopy as a detector of topographic contrast. The detector can detect backscattered electrons or the sum of backscattered electrons and secondary electrons, with different amount of secondary electrons. As a backscattered electron detector it collects backscattered electrons emitted in a specific range of take‐off angles and in a large range of azimuth angles enabling to obtain large solid collection angle and high collection efficiency. Two arrangements with different channel electron multipliers were studied theoretically with the use of the Monte Carlo method and one of them was built and tested experimentally. To shorten breaks in operation, a vacuum box preventing channel electron multipliers from an exposure to air during specimen exchanges was built and placed in the microscope chamber. The box is opened during microscope observations and is moved to the side of the scanning electron microscope chamber and closed during air admission and evacuation cycles enabling storing channel electron multipliers under vacuum for the whole time. Experimental tests of the detector included assessment of the type of detected electrons (secondary or backscattered), checking the tilt contrast, imaging the spatial collection efficiency, measuring the noise coefficient and recording images of different specimens.  相似文献   

3.
4.
This study has investigated the potential of environmental electron microscopy techniques for studying the structure of polymer‐based electronic devices. Polymer blend systems composed of F8BT and PFB were examined. Excellent contrast, both topographical and compositional, can be achieved using both conventional environmental scanning electron microscopy (ESEM) and a transmission detector giving an environmental scanning transmission electron microscope (ESTEM) configuration. Controllable charging effects present in the ESEM were observed, giving rise to a novel voltage contrast. This shows the potential of such contrast to provide excellent images of phase structure and charge distributions.  相似文献   

5.
Stokes DJ  Thiel BL  Donald AM 《Scanning》2000,22(6):357-365
We report an investigation into a dynamic contrast phenomenon in water-oil emulsions imaged in the environmental scanning electron microscope. Secondary electron contrast between oil and water phases is shown to change with scan rate, even inverting in extreme cases. This effect is attributed to the fact that charge carriers in liquids have intermediate mobilities compared with those in metallic conductors and solid insulators. Thus, increasing the electron energy flux density (via slower scan rates) results in the temporary accumulation of excess charge, which in turn gives rise to increased secondary electron emission. Excess charge dissipates between frames, however, such that classical charging of the specimen is not observed. The oils used here have conductivities lower than that of water, making them more susceptible to the effect. However, the material within the primary electron interaction volume is a conductive medium. We demonstrate that charging effects are not seen in regions of the oil where the interaction volume is in contact with the more conductive continuous water phase. Secondary electron emission from these regions therefore approximates to the intrinsic yield.  相似文献   

6.
J. Hejna 《Scanning》1995,17(6):387-394
Two scintillation backscattered electron (BSE) detectors with a high voltage applied to scintillators were built and tested in a field emission scanning electron microscope (SEM) at low primary beam energies. One detector collects BSE emitted at low take-off angles, the second at high takeoff angles. The low take-off detector gives good topographic tilt contrast, stronger than in the case of the secondary electron (SE) detection and less sensitive to the presence of contamination layers on the surface. The high take-off detector is less sensitive to the topography and can be used for detection of material contrast, but the contrast becomes equivocal at the beam energy of 1 keV or lower.  相似文献   

7.
A new SEM technique for imaging uncoated non-conducting specimens at high beam voltages is described which employs a high-pressure environment and an electric field to achieve charge neutralization. During imaging, the specimen surface is kept at a stable low voltage, near earth potential, by directing a flow of positive gas ions at the specimen surface under the action of an electric bias field at a pressure of about 200 Pa. In this way charge neutrality is continuously maintained to obtain micrographs free of charging artefacts. Images are formed by specimen current detection containing both secondary electron and backscattered electron signal information. Micrographs of geological, ceramic, and semiconductor materials obtained with this method are presented. The technique is also useful for the SEM examination of histological sections of biological specimens without any further preparation. A simple theory for the charge neutralization process is described. It is based on the interaction of the primary and emissive signal components with the surrounding gas medium and the resulting neutralizing currents. Further micrographs are presented to illustrate the pressure dependence of the charge neutralization process in two glass specimens which show clearly identifiable charging artefacts in conventional microscopy.  相似文献   

8.
Cazaux J 《Scanning》2004,26(4):181-203
This paper is an attempt to analyse most of the complicated mechanisms involved in charging and discharging of insulators investigated by scanning electron microscopy (SEM). Fundamental concepts on the secondary electron emission (SEE) yield from insulators combined with electrostatics arguments permit to reconsider, first, the widespread opinion following which charging is minimised when the incident beam energy E0 is chosen to be equal to the critical energy E(o)2, where the nominal total yield delta(o) + eta(o) = 1. For bare insulators submitted to a defocused irradiation, it is suggested here that the critical energy under permanent irradiation EC2 corresponds to a range of primary electrons, R, and nearly equals the maximum escape depth of the secondary electrons, r. This suggestion is supported by a comparison between published data of the SEE yield delta(o) of insulators (short pulse experiments) and experimental results obtained from a permanent irradiation for EC2. New SEE effects are also predicted at the early beginning of irradiation when finely focused probes are used. Practical considerations are also developed, with specific attention given to the role of a contamination layer where a negative charging may occur at any beam energy. The role of the various time constants involved in charging and discharging is also investigated, with special attention given to the dielectric time constant, which explains the dose rate-dependent effects on the effective landing energy in the steady state. Numerical applications permit to give orders of magnitude of various effects, and several other practical consequences are deduced and illustrated. Some new mechanisms for the contrast reversal during irradiation or with the change of the primary electron (PE) energy are also suggested.  相似文献   

9.
Wong WK  Nojeh A  Pease RF 《Scanning》2006,28(4):219-227
Image formation of single-walled carbon nanotubes (SWNTs) in the scanning electron microscope (SEM) is peculiarly sensitive to primary electron landing energy, imaging history, sample/substrate geometry, electrical conductivity, sample contamination, and substrate charging. This sensitivity is probably due to the extremely small interaction volume of the SWNTs' monolayered, nanoscale structures with the electron beam. Traditional electron beam/bulk specimen interaction models appear unable to explain the contrast behavior when directly applied to SWNTs. We present one systematic case study of SWNT SEM imaging with special attention to the above parameters and propose some physical explanations for the effect of each. We also demonstrate that it is possible to employ voltage biasing to counteract this extrinsic behavior, gain better control of the image contrast, and facilitate the interpretation of SWNT images in the SEM.  相似文献   

10.
The mechanisms of electron beam scattering are examined to evaluate its effect on contrast and resolution in high-pressure scanning electron microscopy (SEM) techniques reported in the literature, such as moist-environment ambient-temperature SEM (MEATSEM) or environmental SEM (ESEM). The elastic and inelastic scattering cross-sections for nitrogen are calculated in the energy range 5–25 keV. The results for nitrogen are verified by measuring the ionization efficiency, and measurements are also made for water vapour. The effect of the scattered beam on the image contrast was assessed and checked experimentally for a step contrast function at 20 kV beam voltage. A considerable degree of beam scattering can be tolerated in high-pressure SEM operation without a significant degradation in resolution. The image formation and detection techniques in high-pressure SEM are considered in detail in the accompanying paper.  相似文献   

11.
Cell biologists probing the physiologic movement of macromolecules and solutes across the fenestrated microvascular endothelial cell have used electron microscopy to locate the postulated pore within the fenestrae. Prior to the advent of in-lens field-emission high-resolution scanning electron microscopy (HRSEM) and ultrathin m et al coating technology, quick-freeze, platinum-carbon replica and grazing thin-section transmission electron microscopy (TEM) methods provided two-dimensional or indirect imaging methods. Wedge-shaped octagonal channels composed of fibrils interwoven in a central mesh were depicted as the filtering structures of fenestral diaphragms in images of platinum replicas enhanced by photographic augmentation. However, image accuracy was limited to replication of the cell surface. Subsequent to this, HRSEM technology was developed and provided a high-fidelity, three-dimensional topographic image of the fenestral surface directly from a fixed and dried bulk adrenal specimen coated with a 1 nm chromium film. First described from TEM replicas, the “flower-like” structure comprising the fenestral pores was readily visualized by HRSEM. High-resolution images contained particulate ectodomains on the lumenal surface of the endothelial cell membrane. Particles arranged in a rough octagonal shape formed the fenestral rim. Digital acquisition of analog photographic recordings revealed a filamentous meshwork in the diaphragm, thus confirming and extending observations from replica and grazing section TEM preparations. Endothelial cell pockets, first described in murine renal peritubular capillaries, were observed in rhesus and rabbit adrenocortical capillaries. This report features recent observations of fenestral diaphragms and endothelial pockets fitted with multiple diaphragms utilizing a Schottky field-emission electron microscope. In-lens staging of bulk and thin section specimens allowed tandem imaging in HRSEM and scanning TEM modes at 25 kV.  相似文献   

12.
Ishitani T  Sato M 《Scanning》2002,24(4):191-203
The two conventional methods currently employed for the evaluation of image resolution in scanning electron microscopy are the gap method and a fast Fourier transform (FFT) method. These can be highly dependent on personal expertise on the distinction between signal information and noise contained in a micrograph. Hence, the present paper proposes an alternative method (referred to as a contrast-to-gradient (CG) method) that can determine the image resolution of a micrograph without requiring personal expertise on the judgment of noise. The image resolution in the CG method is defined as a weighted harmonic mean of the local resolution, which is proportional to the quotient of the threshold contrast divided by the local gradient. The local gradient is calculated from the quadratic function that best fits the local pixel intensities over 5 x 5 pixels. It has been shown that the CG method, compared with the FFT method, has a broader range of applications for various types of images, such as low-contrast, noise-containing, filter-processed, highly directional, and quasi-periodic feature images.  相似文献   

13.
A consortium of microorganisms with the capacity to degrade crude oil has been characterized by means of confocal laser scanning microscopy (CLSM), transmission electron microscopy (TEM), and scanning electron microscopy (SEM). The analysis using CLSM shows that Microcoleus chthonoplastes is the dominant organism in the consortium. This cyanobacterium forms long filaments that group together in bundles inside a mucopolysaccharide sheath. Scanning electron microscopy and transmission electron microscopy have allowed us to demonstrate that this cyanobacterium forms a consortium primarily with three morphotypes of the heterotrophic microorganisms found in the Microcoleus chthonoplastes sheath. The optimal growth of Microcoleus consortium was obtained in presence of light and crude oil, and under anaerobic conditions. When grown in agar plate, only one type of colony (green and filamentous) was observed.  相似文献   

14.
In a scanning electron microscope, electron-beam irradiation of insulators may induce a strong electric field due to the trapping of charges within the specimen interaction volume. On one hand, this field modifies the trajectories of the beam of electrons subsequently entering the specimen, resulting in reduced penetration depth into the bulk specimen. On the other hand, it leads to the acceleration in the vacuum of the emitted secondary electrons (SE) and also to a strong distortion of their angular distribution. Among others, the consequences concern an anomalous contrast in the SE image. This contrast is due to the so-called pseudo-mirror effect. The aim of this work is first to report the observation of this anomalous contrast, then to give an explanation of this effect, and finally to discuss the factors affecting it. Practical consequences such as contrast interpretations will be highlighted.  相似文献   

15.
The relative weight, δΒ, of the yield of secondary electrons, SE2, induced by the backscattered electrons, BSE, with respect to that, δP, of secondary electrons, SE1, induced by the primary electrons, PE, is deduced from simple theoretical considerations. At primary energies E0 larger than EM (where the total SE yield δ = δP + δB is maximum), the dominant role of the backscattering events is established. It is illustrated in SEM by a direct comparison of the contrast between SE images and BSE images obtained at E0 ~ 5 keV and E0 ~ 15 keV on a stratified specimen. At energies E0 less than EM, the dominant role of SE1 electrons with respect to SE2 (and SE3) is established. It is illustrated by the better practical resolution of diamond images obtained with an in‐lens detection in low voltage SEM E0 ~ 0.2–1 keV range compared with that obtained with a lateral detector. The present contribution illustrates the improved performance of LVSEM in terms of contrast and of practical resolution as well as the importance of variable voltage methods for subsurface imaging. The common opinion that the practical lateral resolution is given by the incident spot diameter is also reconsidered in LVSEM.  相似文献   

16.
17.
Patat JM  Lehuede P  Durand O  Cazaux J 《Scanning》2002,24(3):109-116
Using primary beam energies E0 ranging from 0.2 to 15 keV and an in-lens detector, a series of images of the same region of an artificial microstructured diamond sample have been acquired in scanning electron microscopy. Next, the images were analysed by using a scatter diagram technique to underline the topographic contrast change and contrast reversal. The results obtained from 0.5 to 15 keV are discussed with the help of an expression derived from the constant loss model for the secondary electron yield delta of diamond, but including the respective roles of the angle of incidence, i, and of the angle of detection, alpha. More surprising is the quality of images obtained at a beam energy as low as 0.2 keV, and more difficult to explain is the significant contrast change between 0.2 keV and 0.5 keV. For the first time, scatter diagrams are used as a diagnostic tool in scanning electron microscopy, and after some improvements it is hoped that the experimental approach followed here may lead to quantitative estimates of the local tilts of a specimen surface.  相似文献   

18.
A novel secondary electron detection system combining a two‐stage detector head and a differential pumping system is presented. The detector head consisted of a scintillation Everhart‐Thornley detector and a microsphere plate, separating it from the lower vacuum in the intermediate chamber (below 0.1 mbar). The system was arranged asymmetrically, which should contribute to a lower gas leakage through the plate and a longer life span of the plate. The system offered all the advantages of the scintillator detector in a wide range of gas pressures, from high vacuum to those of the order of 10 mbar, typical of high‐pressure scanning electron microscopy.  相似文献   

19.
20.
Zhang P  Wang HY  Li YG  Mao SF  Ding ZJ 《Scanning》2012,34(3):145-150
Monte Carlo simulation methods for the study of electron beam interaction with solids have been mostly concerned with specimens of simple geometry. In this article, we propose a simulation algorithm for treating arbitrary complex structures in a real sample. The method is based on a finite element triangular mesh modeling of sample geometry and a space subdivision for accelerating simulation. Simulation of secondary electron image in scanning electron microscopy has been performed for gold particles on a carbon substrate. Comparison of the simulation result with an experiment image confirms that this method is effective to model complex morphology of a real sample.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号