首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this paper, the test results of liquid injection impact on the performance of new alternative refrigerant mixtures such as: R-410A, R-507, R-407C and R-404A are discussed, analysed and presented. The test results were obtained using an air-source heat pump set-up with enhanced surface tubing under various liquid injection ratios. Performance tests were conducted according to the ARI/ASHRAE standards. The performance data demonstrated that as liquid injection ratio increases, compressor head pressure and discharge temperature decrease. This has a positive effect in protecting the compressor. The effect of liquid injection on mixture behaviour varies from one mixture to another depending upon the mixture's composition. Furthermore, liquid injection appears to have a significant influence on R-410A behaviour compared to the other mixtures in question. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

2.
In this paper, the impact of gas/liquid injection on the behaviour of new alternative refrigerant mixtures such as; R-410A, R-507, R-407C, and R-404A are discussed, analysed and presented. The test results were obtained using an air–source heat pump set up with enhanced surface tubing heat exchanger under various gas/liquid injection ratios. Performance tests were conducted according to the ARI/ASHRAE Standards. The performance data demonstrated that as gas/liquid injection increases compressor head pressure and discharge temperature decrease and this has a positive effect in protecting the compressor. The effect of gas/liquid injection on mixture behaviour varies from mixture to another depending upon the mixture composition. Furthermore, hot gas injection appears to have a significant and positive influence on the COP. The performance of refrigerants R-407C and R-404A has been enhanced with 5% gas injection and mix of gas and liquid 5% injection, respectively. The data presented in these figures also show that other hot gas injection ratios and gas/liquid mix degrade the heat exchanger performance. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

3.
The behaviour of some new alternative refrigerant mixtures such as R‐410A, R‐507, R‐407C, and R‐404A under various conditions of magnetic field are discussed, analysed and presented. The effect of magnetic field on mixture behaviour varies from one mixture to another depending upon the mixture's composition and its boiling point and consequently on the thermophysical properties. Furthermore, the use of magnetic field appears to have a positive influence on the thermal capacities of the condenser and the evaporator depending upon the refrigerant mixture's thermophysical properties. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

4.
In this paper, energy efficiency results are presented for a new HFC ternary blend proposed as a substitute for CFC 502 and HCFC 22. The blend is composed of R-23/R-32/R-125. Performance evaluation test results were obtained after an experimental heat pump set up with a 3 kW rotary compressor. The refrigerants tested in this study under different conditions were HCFC-22, as a reference base refrigerant and R-410a (HFC-32/HFC-125), R-407c (HFC-32/HFC-125/HFC-134a), as well as quaternary mixture; HFC-32/HFC-125/HFC-143a/HFC-134a. The experimental data showed that our proposed HFC ternary blend R-23/R-32/R-125 has superior performance compared to other proposed HFC alternatives such as R-410a and R-407c, under the same conditions. Pressure ratios and head pressures were compatible with new compressors to be used in new systems. Furthermore, experimental results demonstrated that the ternary blend R-23/R-32/R-125 is the best performing replacement for R-22 in heat pump applications and low temperature equipment. Experiments also showed that the heat pump system using R-23/R-32/R-125 was stable and experienced reasonable head pressures. © 1997 John Wiley & Sons, Ltd.  相似文献   

5.
Two phase flow heat transfer characteristics observed under magnetic field during condensation of refrigerant mixtures R-404A, R407C and R507 as well as R-410A were observed, analyzed and presented in this paper. Experiments showed that magnetic field tends to enhance the condensation characteristics at lower Reynolds numbers. The data clearly indicated that values of the condensation heat transfer coefficient of refrigerant mixtures under investigation were significantly influenced by the Magnetohyrdodynamic (MHD) effects depending upon the type of refrigerant mixture. The proposed correlation appears to predict the heat transfer coefficient with an average deviation of ± 10.  相似文献   

6.
In this paper, an experimental study on the heat transfer characteristics of two-phase flow boiling of alternative azeotropic refrigerant mixtures to R-502 on air/refrigerant horizontal enhanced surface tubing is presented. Correlations were proposed to predict the heat transfer characteristics such as average heat transfer coefficients, as well as pressure drops of alternatives to R-502; such as R-507, R-404A, R-407B, and R-408A in two-phase flow boiling inside enhanced surface tubing. In addition, it was found that the refrigerant mixture’s pressure drop is a weak function of the mixture’s composition. It was found that the correlations were applicable to the entire heat and mass flux, investigated in the present study for the proposed blends under question. The deviation between the experimental and predicted values for the heat transfer coefficient and pressure drop were less than ±20% and 35%, respectively, for the majority of data.  相似文献   

7.
An experimental study on in-tube flow boiling heat transfer of R-134a/R-290/R-600a refrigerant mixture has been carried out under varied heat flux test conditions. The heat transfer coefficients are experimentally measured at temperatures between ?8 and 5 °C for mass flow rates of 3–5 g s?1. Acetone is used as a hot fluid which flows in the outer tube of diameter 28.57 mm while the refrigerant mixture flows in the inner tube of diameters 9.52 and 12.7 mm. By regulating the acetone flow conditions, the heat flux is maintained between 2 and 8 kW/m2 and the pressure of the refrigerant is maintained between 3.2 and 5 bar. The comparison of experimental results with the familiar correlations shows that the correlations over predict the heat transfer coefficients for this mixture when stratified and stratified-wavy flow prevail. Multiple regression technique is used to evolve and modify existing correlations to predict the heat transfer coefficient of the refrigerant mixture. It is found that the modified version of Lavin–Young correlation (1965) predicts the heat transfer coefficient of the considered mixture within an average deviation of ±20.5 %.  相似文献   

8.
Saturated flow boiling heat transfer and the associated frictional pressure drop of the ozone friendly refrigerant R-410A (a mixture of 50 wt% R-32 and 50 wt% R-125) flowing in a vertical plate heat exchanger (PHE) are investigated experimentally in the study. In the experiment two vertical counter flow channels are formed in the exchanger by three plates of commercial geometry with a corrugated sinusoidal shape of a chevron angle of 60°. Upflow boiling of saturated refrigerant R-410A in one channel receives heat from the downflow of hot water in the other channel. The experimental parameters in this study include the refrigerant R-410A mass flux ranging from 50 to 125 kg/m2 s and imposed heat flux from 5 to 35 kW/m2 for the system pressure fixed at 1.08, 1.25 and 1.44 MPa, which respectively correspond to the saturated temperatures of 10, 15 and 20 °C. The measured data showed that both the boiling heat transfer coefficient and frictional pressure drop increase almost linearly with the imposed heat flux. Furthermore, the refrigerant mass flux exhibits significant effect on the saturated flow boiling heat transfer coefficient only at higher imposed heat flux. For a rise of the refrigerant pressure from 1.08 to 1.44 MPa, the frictional pressure drops are found to be lower to a noticeable degree. However, the refrigerant pressure has very slight influences on the saturated flow boiling heat transfer coefficient. Finally, empirical correlations are proposed to correlate the present data for the saturated boiling heat transfer coefficients and friction factor in terms of the Boiling number and equivalent Reynolds number.  相似文献   

9.
This work presents the results of an experimental study concerning the heat transfer characteristics of two-phase flow condensation and boiling of tetrary (R-32/R-125/R143a/R134a) refrigerant mixtures inside water/refrigerant horizontal enhanced surface tubing. Heat transfer characteristics such as average heat transfer coefficients, as well as pressure drops of the tetrary refrigerant mixtures, have been predicted and compared with other mixtures during flow condensation and boiling inside enhanced surface tubing. It was found that the tetrary refrigerant blend has higher transfer coefficients than R-502, and the lowest pressure drop among the refrigerants studied. © 1997 by John Wiley & Sons, Ltd.  相似文献   

10.
《Applied Thermal Engineering》2002,22(14):1535-1548
In this paper, an analytical study on the influence of thermophysical properties on heat transfer characteristics of two-phase flow boiling of some refrigerant mixtures in air/refrigerant horizontal enhanced surface tubing is presented.Correlations were proposed to predict the thermophysical properties of refrigerant mixtures such as thermal conductivity and viscosity as well as their impact on the heat transfer characteristics such as average heat transfer coefficients, and pressure drops of R-507, R-404A, R-410A, and R-407C in two-phase flow boiling inside enhanced surface tubing. In addition, it was found that the refrigerant mixture's pressure drop is a weak function of the mixture's composition.It was also evident that the proposed improved correlations for predicting the thermophysical properties were applicable to the entire heat and mass flux, investigated in the present study. The deviation between the experimental and predicted value using new and improved correlations for the heat transfer coefficient and pressure drop were <±20 %, for the majority of data.  相似文献   

11.
《Applied Thermal Engineering》2000,20(12):1113-1126
This paper presents an experimental study of two phase flow condensation of some alternative zeotropic refrigerant mixtures to R-22, inside air/refrigerant horizontal enhanced surface tubing. The alternatives considered in this study are; R-507, R-404A, R-407C, and R-408A as well as R-410A. It was evident from the condensation experimental data that R-408A has the highest heat transfer rate compared to the other blends under the investigated range of refrigerant mass flow rates and heat flux. However, when the thermophysical properties are factored in, the condensation data showed that R-410A has the highest heat transfer rate at Reynolds number higher than 2.35E+7 Furthermore, experimental data of two phase condensation pressure gradient data across the test section at different Reynolds numbers showed that R-410A has the highest convective pressure drop among the blends under investigation.  相似文献   

12.
An experiment is conducted here to investigate how the channel size affects the subcooled flow boiling heat transfer and the associated bubble characteristics of refrigerant R-407C in a horizontal narrow annular duct with the gap of the duct fixed at 1.0 and 2.0 mm. The measured boiling curves indicate that the temperature overshoot at ONB is relatively significant for the subcooled flow boiling of R-407C in the duct. Besides, the subcooled flow boiling heat transfer coefficient increases with a reduction in the duct gap, but decreases with an increase in the inlet liquid subcooling. Moreover, raising the heat flux imposed on the duct can cause a significant increase in the boiling heat transfer coefficients. However, the effects of the refrigerant mass flux and saturated temperature on the boiling heat transfer coefficient are slighter. Visualization of the subcooled flow boiling processes in the duct reveals that the bubbles are suppressed to become smaller and less dense by raising the refrigerant mass flux and inlet subcooling. Raising the imposed heat flux, however, produces positive effects on the bubble population, coalescence and departure frequency. Meanwhile, the present heat transfer data for R-407C are compared with the R-134a data measured in the same duct and with some existing correlations. We also propose empirical correlations for the present data for the R-407C subcooled flow boiling heat transfer and some quantitative bubble characteristics such as the mean bubble departure diameter and frequency and the active nucleation site density.  相似文献   

13.
Effect of nanoparticle size on nucleate pool boiling heat transfer of refrigerant/oil mixture with nanoparticles was investigated experimentally. For the preparation of the test fluid, refrigerant R113, ester oil VG68, and Cu nanoparticles with three different average diameters of 20, 50 and 80 nm were used. Experimental conditions include a saturation pressure of 101.3 kPa, heat fluxes from 10 to 80 kW m?2, nanoparticle concentrations in the nanoparticles/oil suspension from 0 to 30 wt%, and nanoparticles/oil suspension concentrations from 0 to 5 wt%. The experimental results indicate that the nucleate pool boiling heat transfer coefficient of R113/oil mixture with Cu nanoparticles is enhanced by a maximum of 23.8% with the decrease of nanoparticle size from 80 to 20 nm under the present experimental conditions, and the enhancement increases with the decrease of nanoparticles/oil suspension concentration or the increase of nanoparticles concentrations in the nanoparticles/oil suspension. A general nucleate pool boiling heat transfer coefficient correlation for refrigerant/oil mixture with nanoparticles is proposed, and it agrees with 93% of the existing experimental data of refrigerant/oil mixture with nanoparticles within a deviation of ±20%.  相似文献   

14.
In this article, the experiment is carried out with four stages of test section and new experimental data of non-azeotropic refrigerant mixtures R-22/R-124 are presented. Existing correlations are analysed and new ones are proposed for pure refrigerants. The nucleate boiling correlation of the refrigerant mixtures is modified so as to obtain the evaporation heat transfer coefficient of the refrigerant mixtures in a smooth tube. The result shows that the majority of the predictions fall within ±30% of the experiments.  相似文献   

15.
The evaporation heat transfer experiments were conducted with an oblong shell and plate heat exchanger without oil in the refrigerant loop using R-410A, a mixture of 50 wt% R-32 and 50 wt% R-125 that exhibits azeotropic behavior. An experimental refrigerant loop has been established to measure the evaporation heat transfer coefficient h r of R-410A in a vertical oblong shell and plate heat exchanger. Four vertical counter-flow channels were formed in the oblong shell and plate heat exchanger by four plates having a corrugated trapezoid shape of a 45° chevron angle. The upflow of the boiling R-410A in one channel receives heat from the hot downflow of water in the other channel. The effects of the refrigerant mass flux, average heat flux, refrigerant saturation temperature, and vapor quality of R-410A on the measured data were explored in detail. The results indicate that a rise in the refrigerant mass flux causes an increase in the h r . Raising the imposed wall heat flux was found to slightly improve h r . Finally, at a higher refrigerant saturation temperature, the h r is found to be lower. Based on the present data, an empirical correlation of the evaporation heat transfer coefficient was proposed.  相似文献   

16.
Experiments are conducted here to investigate how the channel size affects the R-410A saturated flow boiling heat transfer and associated bubble characteristics in a horizontal narrow annular duct. The gap of the duct is fixed at 1.0 and 2.0 mm in this study. The measured data indicate that the saturated flow boiling heat transfer coefficient increases with increasing refrigerant mass flux and saturated temperature and with a decrease in the gap size. Besides, raising the imposed heat flux can cause a significant increase in the boiling heat transfer coefficient. The results from the flow visualization show that the mean diameter of the bubbles departing from the heating surface decreases slightly with increasing refrigerant mass flux and saturated temperature. Moreover, the bubble departure frequency increases at reducing duct size and increasing mass flux. And at a high imposed heat flux many bubbles generated from the cavities in the heating surface tend to merge together to form big bubbles. Meanwhile, comparisons of the present heat transfer data for R-410A with R-407C and R-134a in the same duct and with some existing correlations are conducted. Furthermore, an empirical correlation for the present R-410A saturated flow boiling heat transfer data is proposed.  相似文献   

17.
This paper reports an experimental investigation of heat-transfer and pressure-drop behavior of R-290, R-600, and R-290/R-600 in the three-lines serpentine small-diameter (2.46 mm) tube bank. Heat transfer coefficients and pressure drop characteristics are measured for a range of heat flux (5–21 kW/m2), mass flux (250–500 kg/m2 s), equilibrium mass quality (0–0.86), and the fixed mixture composition ((R-290/R-600 (55 wt.%/45 wt.%)). The results show that the flow boiling heat transfer coefficients for R-290, R-600, and R-290/R-600 are 1.66–1.96-fold, 1.28–1.38-fold and 1.57–1.88-fold greater as compared with those for R-134a under equal heat and mass fluxes. Also, the two-phase flow frictional pressure drop for R-600, R-290/R-600 and R-290 are 1.41–1.60-fold, 1.32–1.50-fold and 1.22–1.40-fold smaller as compared with that for R-134a. A new heat transfer correlation was presented by using a superposition model to predict the experimental data for both pure refrigerants and refrigerant mixtures. Experimental results were compared with several correlations which predict the evaporative heat transfer, which are in good agreement with experimental data.  相似文献   

18.
Subcooled flow boiling heat transfer characteristics of refrigerant R-134a in a vertical plate heat exchanger (PHE) are investigated experimentally in this study. Besides, the associated bubble characteristics are also inspected by visualizing the boiling flow in the vertical PHE. In the experiment two vertical counterflow channels are formed in the exchanger by three plates of commercial geometry with a corrugated sinusoidal shape of a chevron angle of 60°. Upflow boiling of subcooled refrigerant R-134a in one channel receives heat from the downflow of hot water in the other channel. The effects of the boiling heat flux, refrigerant mass flux, system pressure and inlet subcooling of R-134a on the subcooled boiling heat transfer are explored in detail. The results are presented in terms of the boiling curves and heat transfer coefficients. The measured data showed that the slopes of the boiling curves change significantly during the onset of nucleate boiling (ONB) especially at low mass flux and high saturation temperature. Besides, the boiling hysteresis is significant at a low refrigerant mass flux. The subcooled boiling heat transfer coefficient is affected noticeably by the mass flux of the refrigerant. However, increases in the inlet subcooling and saturation temperature only show slight improvement on the boiling heat transfer coefficient.The photos from the flow visualization reveal that at higher imposed heat flux the plate surface is covered with more bubbles and the bubble generation frequency is substantially higher, and the bubbles tend to coalesce to form big bubbles. But these big bubbles are prone to breaking up into small bubbles as they move over the corrugated plate, producing strong agitating flow motion and hence enhancing the boiling heat transfer. We also note that the bubbles nucleated from the plate are suppressed to a larger degree for higher inlet subcooling and mass flux. Finally, empirical correlations are proposed to correlate the present data for the heat transfer coefficient and the bubble departure diameter in terms of boiling, Froude, Reynolds and Jakob numbers.  相似文献   

19.
In the present paper, critical heat flux (CHF) experiments of forced convection boiling were performed to investigate the CHF characteristics of a vertical annular channel with one heated rod and four spacer grids for new refrigerant R-134a. The experiments were conducted under outlet pressure of 11.6, 13, 16 and 20 bar, mass fluxes of 100–600 kg/m2 s, and inlet temperatures of 25–40 °C. The parametric trend of the CHF data was well consistent with previous understanding in water. The comparison between the present results with effect of the flow obstacle enhancing CHF and water data in similar geometry shows R-134a can be a modeling fluid for simulating water CHF in high pressure and high temperature condition even for annular geometry. The direct observation of flowing bubble behaviors contributes to enhancing our understanding on the effect of flow obstacles for flow boiling heat transfer.  相似文献   

20.
An experimental study on the characteristics of two phase flow boiling of pure refrigerants such as R12 and R22 as well as nonazeotropic refrigerant mixtures R22/R114 and R22/R152a inside horizontal enhanced surface tubing is presented. The enhanced surface tubing results showed a significant improvement of the heat transfer over that of an equivalent smooth tube, depending on the mixture components and their concentrations. Correlations are proposed to predict the heat transfer characteristics such as average heat transfer coefficients as well as pressure drops of nonazeotropic refrigerant mixture flow boiling inside enhanced surface tubing. In addition, it was found that the refrigerant mixtures pressure drop is a weak function of the mixture compositions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏