首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Rotating multisegment slant-hole (RMSSH) single photon emission computed tomography (SPECT) is suitable for detecting small and low-contrast breast lesions since it has much higher detection efficiency than conventional SPECT with a parallel-hole collimator and can image the breast at a closer distance. Our RMSSH SPECT reconstruction extends a previous rotation-shear transformation-based method to include nonuniform attenuation and collimator-detector response (CDR) compensation. To evaluate our reconstruction method, we performed two phantom simulation studies with 1) an isolated breast and 2) a breast phantom attached to the body torso. The reconstructed RMSSH SPECT images with attenuation and CDR compensation showed improved quantitative accuracy and less image artifacts than without. To evaluate the clinical efficacy of RMSSH SPECT mammography, we used a simulation study to compare with planar scintimammography in terms of the signal-to-noise ratio (SNR) value of a breast lesion. The RMSSH SPECT reconstruction images showed higher SNR value than the planar scintimammography images and even more so as we applied compensation for attenuation and collimator detector response. We conclude that attenuation and CDR compensation provide RMSSH SPECT mammography images with improved quality and quantitative accuracy.  相似文献   

2.
The discrete filtered backprojection (DFBP) algorithm used for the reconstruction of single photon emission computed tomography (SPECT) images affects image quality because of the operations of filtering and discretization. The discretization of the filtered backprojection process can cause the modulation transfer function (MTF) of the SPECT imaging system to be anisotropic and nonstationary, especially near the edges of the camera's field of view. The use of shift-invariant restoration techniques fails to restore large images because these techniques do not account for such variations in the MTF. This study presents the application of a two-dimensional (2D) shift-variant Kalman filter for post-reconstruction restoration of SPECT slices. This filter was applied to SPECT images of a hollow cylinder phantom; a resolution phantom; and a large, truncated cone phantom containing two types of cold spots, a sphere, and a triangular prism. The images were acquired on an ADAC GENESYS camera. A comparison was performed between results obtained by the Kalman filter and those obtained by shift-invariant filters. Quantitative analysis of the restored images performed through measurement of root mean squared errors shows a considerable reduction in error of Kalman-filtered images over images restored using shift-invariant methods.  相似文献   

3.
Scatter correction is an important factor in single photon emission computed tomography (SPECT). Many scatter correction techniques, such as multiple-window subtraction and intrinsic modeling with iterative algorithms, have been under study for many years. Previously, we developed an efficient slice-to-slice blurring technique to model attenuation and system geometric response in a projector/backprojector pair, which was used in an ML-EM algorithm to reconstruct SPECT data. This paper proposes a projector/backprojector that models the three-dimensional (3-D) first-order scatter in SPECT, also using an efficient slice-to-slice blurring technique. The scatter response is estimated from a known nonuniform attenuation distribution map. It is assumed that the probability of detection of a first-order scattered photon from a photon that is emitted in a given source voxel and scattered in a given scatter voxel is proportional to the attenuation coefficient value at that voxel. Monte Carlo simulations of point sources and an MCAT torso phantom were used to verify the accuracy of the proposed projector/backprojector model. An experimental Jaszczak torso/cardiac phantom SPECT study was also performed. For a 64 x 64 x 64 image volume, it took 8.7 s to perform each iteration per slice on a Sun ULTRA Enterprise 3000 (167 MHz, 1 Gbyte RAM) computer, when modeling 3-D scatter, attenuation, and system geometric response functions. The main advantage of the proposed method is its easy implementation and the possibility of performing reconstruction in clinically acceptable time.  相似文献   

4.
韩伟 《电视技术》2014,38(3):19-21,30
针对图像中广泛存在的斑点噪声,提出了一种基于Tetrolet变换域抑制方法。该方法首先对噪声图像进行三层Tetrolet分解,获得低频和高频分解系数;然后对于高频Tetrolet分解系数采用基于核方法的自适应维纳滤波器进行滤波处理;对于低频Tetrolet分解系数设计出一种可调节参数的自适应阈值函数进行噪声抑制;最后进行系数重构。实验结果表明,该算法具有较好的滤波效果。  相似文献   

5.
We have developed a new method of compensating for effects of partial volume and spillover in dual-modality imaging. The approach requires segmentation of just a few tissue types within a small volume-of-interest (VOI) surrounding a lesion; the algorithm estimates simultaneously, from projection data, the activity concentration within each segmented tissue inside the VOI. Measured emission projections were fitted to the sum of resolution-blurred projections of each such tissue, scaled by its unknown activity concentration, plus a global background contribution obtained by reprojection through the reconstructed image volume outside the VOI. The method was evaluated using multiple-pinhole μSPECT data simulated for the MOBY mouse phantom containing two spherical lung tumors and one liver tumor, as well as using multiple-bead phantom data acquired on μSPECT and μCT scanners. Each VOI in the simulation study was 4.8 mm (12 voxels) cubed and, depending on location, contained up to four tissues (tumor, liver, heart, lung) with different values of relative (99m)Tc concentration. All tumor activity estimates achieved bias after ~ 15 ordered-subsets expectation maximization (OSEM) iterations (×10 subsets) , with better than 8% precision ( ≤ 25% greater than the Cramer-Rao lower bound). The projection-based fitting approach also outperformed three standardized uptake value (SUV)-like metrics, one of which was corrected for count spillover. In the bead phantom experiment, the mean ± standard deviation of the bias of VOI estimates of bead concentration were 0.9±9.5%, comparable to those of a perturbation geometric transfer matrix (pGTM) approach (-5.4±8.6%); however, VOI estimates were more stable with increasing iteration number than pGTM estimates, even in the presence of substantial axial misalignment between μCT and μSPECT image volumes.  相似文献   

6.
The properties of singular value decomposition (SVD) are used to implement an SVD spatial domain pseudoinverse restoration filter. This type of filter is attractive for poor imaging conditions (low spatial resolution, high image noise) and is thus appealing for nuclear medicine images. The method might offer some advantages over more traditional frequency domain filter techniques since the restoration is performed on a local rather than global basis. High-contrast thyroid phantom images collected at different count densities and low-contrast liver phantom images were processed with the SVD filter. Restored images yielded improved spatial resolution, lesion contrast, and signal-to-noise ratio. The SVD pseudoinverse restoration filter implemented as an interactive process permits the operator to terminate filtering at a stage where the visually "best" image is obtained compared to the original data. Processed images suggest that the technique may have potential for improving lesion detection in nuclear medicine.  相似文献   

7.
Three procedures for the removal of Compton-scattered data in SPECT by constrained deconvolution are presented. The first is a deconvolution of a 2-D measured PSRF containing scatter from a single reconstructed transaxial image; the second is a deconvolution of a 2-D measured point-source response function (PSRF) from each frame of projection data prior to reconstruction; the third involves deconvolution of a 3-D measured PSRF from a stack of reconstructed slices. Results of applying these procedures to data obtained from a phantom containing cold cylinders and to data from a cold spot-resolution phantom are presented and are shown to be superior to the results of correcting for scatter by scatter-window substraction. Both 3-D deconvolution from reconstructed images and 2-D deconvolution from projection data show major improvements in image contrast, resolution, and quantitation. Improvements are especially marked for small (1.0-3.0 cm) cold sources.  相似文献   

8.
Metal implants such as hip prostheses and dental fillings produce streak and star artifacts in the reconstructed computed tomography (CT) images. Due to these artifacts, the CT image may not be diagnostically usable. A new reconstruction procedure is proposed that reduces the streak artifacts and that might improve the diagnostic value of the CT images. The procedure starts with a maximum a posteriori (MAP) reconstruction using an iterative reconstruction algorithm and a multimodal prior. This produces an artifact-free constrained image. This constrained image is the basis for an image-based projection completion procedure. The algorithm was validated on simulations, phantom and patient data, and compared with other metal artifact reduction algorithms.   相似文献   

9.
A method is presented to estimate the acquisition geometry of a pinhole single photon emission computed tomography (SPECT) camera with a circular detector orbit. This information is needed for the reconstruction of tomographic images. The calibration uses the point source projection locations of a tomographic acquisition of three point sources located at known distances from each other. It is shown that this simple phantom provides the necessary and sufficient information for the proposed calibration method. The knowledge of two of the distances between the point sources proves to be essential. The geometry is estimated by fitting analytically calculated projections to the measured ones, using a simple least squares Powell algorithm. Some mild a priori knowledge is used to constrain the solutions of the fit. Several of the geometrical parameters are however highly correlated. The effect of these correlations on the reconstructed images is evaluated in simulation studies and related to the estimation accuracy. The highly correlated detector tilt and electrical shift are shown to be the critical parameters for accurate image reconstruction. The performance of the algorithm is finally demonstrated by phantom measurements. The method is based on a single SPECT scan of a simple calibration phantom, executed immediately after the actual SPECT acquisition. The method is also applicable to cone-beam SPECT and X-ray CT.  相似文献   

10.
An artificial neural network for SPECT image reconstruction   总被引:1,自引:0,他引:1  
An artificial neural network has been developed to reconstruct quantitative single photon emission computed tomographic (SPECT) images. The network is trained with an ideal projection-image pair to learn a shift-invariant weighting (filter) for the projections. Once trained, the network produces weighted projections as a hidden layer when acquired projection data are presented to its input. This hidden layer is then backprojected to form an image as the network output. The learning algorithm adjusts the weighting coefficients using a backpropagation algorithm which minimizes the mean squared error between the ideal training image and the reconstructed training image. The response of the trained network to an impulse projection resembles the ramp filter typically used with backprojection, and reconstructed images are similar to filtered backprojection images.  相似文献   

11.
In single-photon emission computed tomography (SPECT), projection data are acquired by rotating the photon detector around a patient, either in a circular orbit or in a noncircular orbit. The projection data of the desired spatial distribution of emission activity is blurred by the point-response function of the collimator that is used to define the range of directions of gamma-ray photons reaching the detector. The point-response function of the collimator is not spatially stationary, but depends on the distance from the collimator to the point. Conventional methods for deblurring collimator projection data are based on approximating the actual distance-dependent point-response function by a spatially invariant blurring function, so that deconvolution methods can be applied independently to the data at each angle of view. A method is described here for distance-dependent preprocessing of SPECT projection data prior to image reconstruction. Based on the special distance-dependent characteristics of the Fourier coefficients of the sinogram, a spatially variant inverse filter can be developed to process the projection data in all views simultaneously. The algorithm is first derived from Fourier analysis of the projection data from the circular orbit geometry. For circular orbit projection data, experimental results from both simulated data and real phantom data indicate the potential of this method. It is shown that the spatial filtering method can be extended to the projection data from the noncircular orbit geometry. Experiments on simulated projection data from an elliptical orbit demonstrate correction of the spatially variant blurring and distortion in the reconstructed image caused by the noncircular orbit geometry.  相似文献   

12.
A deconvolution scatter correction for a 3-D PET system   总被引:1,自引:0,他引:1  
A method to remove the scattered background from a reconstructed image by deconvolution with a point response function which includes the scatter contribution is presented. The amplitude of the scattered response function is obtained by constraining a region of the corrected image to zero average amplitude. This method assumes that the shape of scatter distribution is shift invariant and independent of the shape of the scattering object and the distribution of the positron activity. The validity of these approximations for the QPET geometry was tested using simulations. An average scatter response function for the system was obtained from these simulations and compared with results from measurements. The method was tested using experimental data from an irregularly shaped acrylic phantom. It was simple to implement and resulted in a satisfactory correction of the scattered background for a small-volume system.  相似文献   

13.
基于虚拟仪器的光声信号采集和成像系统   总被引:1,自引:0,他引:1       下载免费PDF全文
何军锋  谭毅  姚军财 《激光技术》2008,32(5):558-560
为了实现光声信号的快速采集和图像重建,采用基于虚拟仪器的光声信号采集和成像系统进行光声信号采集,由LABVIEW调用MATLAB程序对采集到的数据进行处理,最后利用滤波反投影重建算法,实现了对模拟组织样品的光声层析成像。成像系统的分辨率为0.15mm,重建图像与实物十分吻合。结果表明,该系统具有快速、方便、直观等特点,有望发展成为一种低成本的实用的临床诊断仪器。  相似文献   

14.
Scatter compensation in Tl-201 single photon emission computed tomography (SPECT) presents an interesting challenge because of the multiple emission energies and relatively large proportion of scattered photons. In this paper, the authors present a simulation study investigating reconstructed image noise levels arising from various implementations of iterative reconstruction-based scatter compensation (RBSC) in Tl-201 SPECT. A two-stage analysis was used to study single and multiple energy window implementations of reconstruction-based scatter compensation, and RBSC was compared to the upper limits on performance for other approaches to handling scatter. In the first stage, singular value decomposition of the system transfer matrix was used to analyze noise levels in a manner independent of the choice of reconstruction algorithm, providing results valid across a wide range of regularizations. In the second stage, the data were reconstructed using maximum-likelihood expectation-maximization, and the noise properties of the resultant images were analyzed. The best RBSC performance was obtained using multiple energy windows, one for each emission photopeak, and RBSC outperformed the upper limit on subtraction-based compensation methods. Implementing RBSC with the correct choice of energy window acquisition scheme is promising method for performing scatter compensation for Tl-201 SPECT  相似文献   

15.
在基于图像识别技术的录播系统中,通常使用背景差分法检测运动目标,在当前帧与背景帧做差之后,需要进一步选取合适的阈值进行图像分割,从而最终提取出运动目标的轮廓.研究了基于最大类间方差准则的图像阈值分割,在此基础上进一步研究了掏空内部点的轮廓提取算法,并且使用轮廓缺陷修补技术改进轮廓提取算法,从而得到封闭的轮廓,最后使用Freeman链码表示提取的轮廓.实验证明,该算法为录播系统的实现提供了良好的技术保障.  相似文献   

16.
In recent years, many investigators have proposed Gibbs prior models to regularize images reconstructed from emission computed tomography data. Unfortunately, hyperparameters used to specify Gibbs priors can greatly influence the degree of regularity imposed by such priors and, as a result, numerous procedures have been proposed to estimate hyperparameter values, from observed image data. Many of these, procedures attempt to maximize the joint posterior distribution on the image scene. To implement these methods, approximations to the joint posterior densities are required, because the dependence of the Gibbs partition function on the hyperparameter values is unknown. Here, the authors use recent results in Markov chain Monte Carlo (MCMC) sampling to estimate the relative values of Gibbs partition functions and using these values, sample from joint posterior distributions on image scenes. This allows for a fully Bayesian procedure which does not fix the hyperparameters at some estimated or specified value, but enables uncertainty about these values to be propagated through to the estimated intensities. The authors utilize realizations from the posterior distribution for determining credible regions for the intensity of the emission source. The authors consider two different Markov random field (MRF) models-the power model and a line-site model. As applications they estimate the posterior distribution of source intensities from computer simulated data as well as data collected from a physical single photon emission computed tomography (SPECT) phantom  相似文献   

17.
We present an analytical scatter correction, based upon the Klein-Nishina formula, for singles-mode transmission data in positron emission tomography (PET) and its implementation as part of an iterative image reconstruction algorithm. We compared our analytically-calculated scatter sinogram data with previously validated simulation data for a small animal PET scanner with 68 Ge (a positron emitter) and 57 Co (approximately 122-keV photon emitter) transmission sources using four different phantom configurations (three uniform water cylinders with radii of 25, 30, and 45 mm and a nonuniform phantom consisting of water, Teflon, and air). Our scatter calculation correctly predicts the contribution from single-scattered (one incoherent scatter interaction) photons to the simulated sinogram data and provides good agreement for the percent scatter fraction (SF) per sinogram for all phantoms and both transmission sources. We then applied our scatter correction as part of an iterative reconstruction algorithm for PET transmission data for simulated and experimental data using uniform and nonuniform phantoms. For both simulated and experimental data, the reconstructed linear attenuation coefficients (mu-values-values) agreed with expected values to within 4% when scatter corrections were applied, for both the 68 Ge and 57 Co transmission sources. We also tested our reconstruction and scatter correction procedure for two experimental rodent studies (a mouse and rat). For the rodent studies, we found that the average mu-values for soft-tissue regions of interest agreed with expected values to within 4%. Using a 2.2-GHz processor, each scatter correction iteration required between 6-27 min of CPU time (without any code optimization) depending on the phantom size and source used. This extra calculation time does not seem unreasonable considering that, without scatter corrections, errors in the reconstructed mu-values were between 18%-45% depending on the phantom size and transmission source used.  相似文献   

18.
The authors present the fusion of anatomical data as a method for improving the reconstruction in single photon emission computed tomography (SPECT). Anatomical data is used to deduce a parameterized model of organs in a reconstructed slice using spline curves. This model allows the authors to define the imaging process, i.e., the direct problem, more adequately, and furthermore to restrict the reconstruction to the emitting zones. Instead of the usual square pixels, the authors use a new kind of discretization pixel, which fits to the contour in the region of interest. In the reconstruction phase, the authors estimate the activity in the emitting zones and also the optimum parameters of their model. Concentrating on the left ventricular (LV) wall activity, the simulation and phantom results show an accurate estimation of both the myocardial shape and the radioactive emission  相似文献   

19.
何军锋  谭毅 《激光技术》2008,32(5):558-558
为了实现光声信号的快速采集和图像重建,采用基于Labview软件平台的光声信号采集和成像系统进行光声信号采集,并调用Matlab程序对采集到的数据进行处理,最后利用滤波反投影重建算法,实现了对模拟组织样品的光声层析成像。成像系统的分辨率为0.15mm,重建图像与实物十分吻合。实验表明,该系统具有快速、方便、直观等特点,有望发展成为一种低成本的实用的临床诊断仪器。  相似文献   

20.
A Bayesian method is presented for simultaneously segmenting and reconstructing emission computed tomography (ECT) images and for incorporating high-resolution, anatomical information into those reconstructions. The anatomical information is often available from other imaging modalities such as computed tomography (CT) or magnetic resonance imaging (MRI). The Bayesian procedure models the ECT radiopharmaceutical distribution as consisting of regions, such that radiopharmaceutical activity is similar throughout each region. It estimates the number of regions, the mean activity of each region, and the region classification and mean activity of each voxel. Anatomical information is incorporated by assigning higher prior probabilities to ECT segmentations in which each ECT region stays within a single anatomical region. This approach is effective because anatomical tissue type often strongly influences radiopharmaceutical uptake. The Bayesian procedure is evaluated using physically acquired single-photon emission computed tomography (SPECT) projection data and MRI for the three-dimensional (3-D) Hoffman brain phantom. A clinically realistic count level is used. A cold lesion within the brain phantom is created during the SPECT scan but not during the MRI to demonstrate that the estimation procedure can detect ECT structure that is not present anatomically.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号