首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Centralised power control of wind farm with doubly fed induction generators   总被引:3,自引:0,他引:3  
At the moment, the control ability of wind farms is a prime research concern for the grid integration of large wind farms, due to their required active role in the power system. This paper describes the on-going work of a research project, whose overall objective is to analyse and assess the possibilities for control of different wind farm concepts. The scope of this paper is the control of a wind farm made up exclusively of doubly fed induction generators. The paper addresses the design and implementation issues of such a controller and focuses on the ability of the wind farm control strategy to regulate the wind farm power production to the reference power ordered by the system operators. The presented wind farm control has a hierarchical structure with both a central control level and a local control level. The central wind farm control level controls the power production of the whole farm by sending out reference power signals to each individual wind turbine, while the local wind turbine control level ensures that the reference power signal send by the central control level is reached. The performance of the control strategy is assessed and discussed by means of simulations illustrated both at the wind farm level and at each individual wind turbine level.  相似文献   

2.
As a result of increasing wind farms penetration in power systems, the wind farms begin to influence power system, and thus the modelling of wind farms has become an interesting research topic. Nowadays, doubly fed induction generator based on wind turbine is the most widely used technology for wind farms due to its main advantages such as high-energy efficiency and controllability, and improved power quality. When the impact of a wind farm on power systems is studied, the behavior of the wind farm at the point common coupling to grid can be represented by an equivalent model derived from the aggregation of wind turbines into an equivalent wind turbine, instead of the complete model including the modelling of all the wind turbines. In this paper, a new equivalent model of wind farms with doubly fed induction generator wind turbines is proposed to represent the collective response of the wind farm by one single equivalent wind turbine, even although the aggregated wind turbines operate receiving different incoming winds. The effectiveness of the equivalent model to represent the collective response of the wind farm is demonstrated by comparing the simulation results of equivalent and complete models both during normal operation and grid disturbances.  相似文献   

3.
The aim of the work is to derive a steady state PQ‐diagram for a variable speed wind turbine equipped with a Doubly Fed Induction Generator. Firstly, the dependency between optimal rotor speed and wind speed is presented. Secondly, the limitations in reactive power production, caused by the rotor current, the rotor voltage and the stator current are derived. Thirdly, the influence of switching from Δ to Y coupling of the stator is investigated. Finally, a complete PQ diagram for a wind turbine is plotted. It is concluded that the limiting factor regarding reactive power production will typically be the rotor current limit, and that the limit for reactive power absorption will be the stator current limit. Further, it is concluded that the rotor voltage will only have a limiting effect at high positive and negative slips, but near the limitation, the reactive power capability is very sensitive to small changes in the slip. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

4.
For the representation of wind farms in transient stability studies of electrical power systems, reduced models based on aggregating identical wind turbines are commonly used. In the case of a wind farm with different wind turbines coupled to the same grid connection point, it is usual to aggregate identical wind turbines operating in similar conditions into an equivalent one. However, in the existing literature, there are not any references to the aggregation of different wind turbines (same wind turbine technology but different rated power or components) into a single one. This paper presents a comparative study of four reduced models for aggregating different DFIG wind turbines, experiencing different incoming winds, into an equivalent model. The first of them is the classical clustering model, in which each equivalent model experiences an equivalent wind. The other reduced models have the same equivalent generation system but different equivalent mechanical systems. Thus, the second and third ones are compound models with a clustering aggregated mechanical system and individual simplified models, respectively, to approximate the individual mechanical power according to the incoming wind speeds. The fourth is a mixed model that uses an equivalent wind speed, which is applied to an equivalent mechanical system (equivalent rotor and drive train) in order to approximate the mechanical power of the aggregated wind turbines. The equivalent models are validated by means of comparison with the complete model of the wind farm when simulated under wind fluctuations and grid disturbances. Finally, recommendations with regard to the applicability of models are established. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

5.
Fault ride-through capability of DFIG wind turbines   总被引:2,自引:0,他引:2  
This paper concentrates on the fault ride-through capability of doubly fed induction generator (DFIG) wind turbines. The main attention in the paper is, therefore, drawn to the control of the DFIG wind turbine and of its power converter and to the ability to protect itself without disconnection during grid faults. The paper provides also an overview on the interaction between variable-speed DFIG wind turbines and the power system subjected to disturbances, such as short circuit faults. The dynamic model of DFIG wind turbine includes models for both mechanical components as well as for all electrical components, controllers and for the protection device of DFIG necessary during grid faults. The viewpoint of the paper is to carry out different simulations to provide insight and understanding of the grid fault impact on both DFIG wind turbines and on the power system itself. The dynamic behaviour of DFIG wind turbines during grid faults is simulated and assessed by using a transmission power system generic model developed and delivered by the Danish Transmission System Operator Energinet.dk in the power system simulation toolbox PowerFactory DIgSILENT. The data for the wind turbines are not linked to a specific manufacturer, but are representative for the turbine and generator type used in variable-speed DFIG wind turbines with pitch control.  相似文献   

6.
Emphasis in this article is on the design of a co‐ordinated voltage control strategy for doubly fed induction generator (DFIG) wind turbines that enhances their capability to provide grid support during grid faults. In contrast to its very good performance in normal operation, the DFIG wind turbine concept is quite sensitive to grid faults and requires special power converter protection. The fault ride‐through and grid support capabilities of the DFIG address therefore primarily the design of DFIG wind turbine control with special focus on power converter protection and voltage control issues. A voltage control strategy is designed and implemented in this article, based on the idea that both converters of the DFIG (i.e. rotor‐side converter and grid‐side converter) participate in the grid voltage control in a co‐ordinated manner. By default the grid voltage is controlled by the rotor‐side converter as long as it is not blocked by the protection system, otherwise the grid‐side converter takes over the voltage control. Moreover, the article presents a DFIG wind farm model equipped with a grid fault protection system and the described co‐ordinated voltage control. The whole DFIG wind farm model is implemented in the power system simulation toolbox PowerFactory DIgSILENT. The DFIG wind farm ride‐through capability and contribution to voltage control in the power system are assessed and discussed by means of simulations with the use of a transmission power system generic model developed and delivered by the Danish Transmission System Operator Energinet.dk. The simulation results show how a DFIG wind farm equipped with voltage control can help a nearby active stall wind farm to ride through a grid fault, without implementation of any additional ride‐through control strategy in the active stall wind farm. Copyright © 2006 John Wiley &Sons, Ltd.  相似文献   

7.
针对风力发电系统中的双馈电机提出一种转子感应电势定向矢量控制方法。通过调节双馈电机转子侧的瞬时有功电流和无功电流,实现对电机力矩和转子侧励磁电流的调节,进而实现双馈电机无功功率调节。在控制过程中只需检测交流侧电流电压,不需要位置传感器,所以可以应用无速度传感器。最终通过仿真试验证明该方法的正确性和实用性。  相似文献   

8.
This paper proposes a novel direct torque and reactive power control (DTC) for grid-connected doubly fed induction generators (DFIGs) in the wind power generation applications. The proposed DTC strategy employs a variable structure control (VSC) scheme to calculate the required rotor control voltage directly and to eliminate the instantaneous errors of active and reactive powers without involving any synchronous coordinate transformations, which essentially enhances the transient performance. Constant switching frequency is achieved as well by using space vector modulation (SVM), which eases the designs of power converter and ac harmonic filters. Simulated results on a 2 MW grid-connected DFIG system are presented and compared with those of the classic voltage-oriented vector control (VC) and traditional look-up-table (LUT) direct power control (DPC). The proposed VSC DTC maintains enhanced transient performance similar to the LUT DPC and keeps the steady-state harmonic spectra at the identical level as the VC strategy when the network is strictly balanced. Besides, the VSC DTC strategy is capable of fully eliminating the double-frequency pulsations in both the electromagnetic torque and the stator reactive power during network voltage unbalance.  相似文献   

9.
10.
Larger percentages of wind power penetration into the grid translate to more demanding requirements coming from grid codes; for example, voltage support at the point of connection has been introduced recently by several grid codes from around the world, thus making it important to analyse this control. Voltage control is actuated by reactive power injection, and for a wind power plant of doubly fed generator turbines, reactive power capability can be a challenge, which typically is overcome by installing reactive power compensators. The integration and the interaction between all these reactive power sources and the on‐load tap changer of the main substation transformer need to be analysed and taken into account in the control design. In this paper, a novel coordination and control strategy for capacitor banks and on‐load tap changer for a wind power plant is introduced. The capacitor banks are controlled in such way that the steady‐state usage of the converters for reactive power injection is driven below to a maximum desired value of 0.1 pu. Additionally, the control transients because of the capacitor bank switching are minimized by using a suitable control structure. The tap changer control is coordinated with the plant control to decrease the impact of the capacitors reactive power in the line drop calculation, thus reducing the amount of tap operations and improving the accuracy of the line drop voltage estimation. The coordination of the central controller with the plant components is analysed and tested through electromagnetic transient program simulations. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

11.
This paper investigates the impact that unbalanced voltage faults have on wind turbine structural loads. In such cases, electromagnetic torque oscillations occur at two times the supply voltage frequency. The objectives of this work are to quantify wind turbine structural loads induced by unbalanced voltage faults relative to those during normal operation; and to evaluate the potential for reducing structural loads with the control of the generator. The method applied is integrated dynamic analysis. Namely, dynamic analysis with models that consider the most important aeroelastic, electrical, and control dynamics in an integrated simulation environment based on an aeroelastic code (HAWC2) and software for control design (Matlab/Simulink). In the present analysis, 1 Hz equivalent loads are used to compare fatigue loads, whereas maximum–minimum values are used to compare extreme loads. A control concept based on resonant filters demonstrates reduction of the structural loads (shaft torsion and tower top side‐to‐side moment) induced by an unbalanced voltage fault.Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

12.
A new control strategy is investigated for Doubly Fed Induction Generators (DFIGs). It exercises control over the generator terminal voltage and output power by adjusting the magnitude and angle of the rotor flux vector. It is shown that this control strategy leads to low interaction between the power and voltage control loop, better system damping and voltage recovery following faults, and it also provides enhanced frequency regulation capability compared with that achieved with existing DFIG controllers described in the open literature. The dynamic performance of the proposed DFIG control is tested for small and large disturbances using a generic network that combines wind and conventional synchronous generation. Simulation results are presented and discussed that demonstrate the capabilities of the new strategy to enhance DFIG performance and its contribution to network operation.  相似文献   

13.
Reactive power control strategy for a wind farm with a doubly fed induction generator (DFIG) is investigated. Under stator flux-oriented (SFO) vector control, the real power of the DFIG is controlled by the q-axis rotor current Iqr and the reactive power is mainly affected by the d-axis rotor current Idr. To examine the effect of Idr on stator reactive power Qs and rotor reactive power Qr, the DFIG is operated under five different operating modes, i.e, the maximum Qs absorption mode, the rotor unity power factor mode, the minimum DFIG loss mode, the stator unity power factor mode, and the maximum Qs generation mode. In pervious works, stator resistance Rs was usually neglected in deriving the d-axis rotor currents Idr for different DFIG reactive power operating modes. In the present work, an iterative algorithm is presented to compute the d-axis rotor currents Idr for the five reactive power control modes. To demonstrate the effectiveness of the proposed iterative algorithm, the rotor current, rotor voltage, stator current, real power and reactive power of a 2.5 MW DFIG operated under the five different operating modes are computed.  相似文献   

14.
Xing Li  Yao Sun  Mei Su  Hui Wang 《风能》2014,17(2):317-336
This paper proposes a coordinated control scheme of a stand‐alone doubly fed induction generator (DFIG)‐based wind energy conversion system to improve the operation performance under unbalanced load conditions. To provide excellent voltage profile for load, a direct stator flux control scheme based on auto‐disturbance rejection control (ADRC) is applied, and less current sensors are required. Due to the virtues of ADRC, the controller has good disturbance rejection capability and is robust to parameter variation. In the case of unbalanced loads, the electromagnetic torque pulsations at double synchronous frequency will exist. To eliminate the undesired effect, the stator‐side converter (SSC) is used to provide the negative sequence current components for the unbalanced load. Usually, proportional integral controllers in a synchronous reference frame are used to control SSC. To simplify the algorithm, an improved proportional resonant (PR) control is proposed and used in the current loop without involving positive and negative sequence decomposition. The improved PR provides more degree of freedom which could be used to improve the performance. The effectiveness of the proposed control scheme has been validated by the simulation and experimental results. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

15.
This paper presents a dynamic model for variable speed wind energy conversion systems, equipped with a variable pitch wind turbine, a synchronous electrical generator, and a full power converter, specially developed for its use in power system stability studies involving large networks, with a high number of buses and a high level of wind generation penetration. The validity of the necessary simplifications has been contrasted against a detailed model that allows a thorough insight into the mechanical and electrical behavior of the system, and its interaction with the grid. The developed dynamic model has been implemented in a widely used power system dynamics simulation software, PSS/E, and its performance has been tested in a well-documented test power network.  相似文献   

16.
The effect of how a wind turbine generator system is operated is discussed from the viewpoint of net power extraction with wind velocity fluctuations in relation to the scale and the dynamic behavior of the system. On a wind turbine generator system consisting of a Darrieus-Savonius hybrid wind turbine, a load generator and a battery, we took up two operating methods: constant tip speed ratio operation for a stand-alone system(Scheme1) and synchronous operation by connecting a grid(Scheme2). With our simulation model, using the result of the net extracting power, we clarified that Scheme1 is more effective than Scheme2 for small-scale systems. Furthermore, in Scheme1, the appropriate rated power output of the system under each wind condition can be confirmed.  相似文献   

17.
18.
以分析双馈风力发电机交流励磁的电磁本质为目标,运用空间矢量理论建立了双馈风力发电机的空间矢量模型;在此基础上,建立了变速变桨双馈风力发电机组的整机模型,给出了不同运行状态下的仿真曲线。在转子绕组自行闭合与加入转子交流励磁2种情况下,对双馈电机中定转子磁动势空间矢量的相位变化进行对比,揭示了交流励磁对于改变转子磁动势空间矢量相位的作用。研究结果表明,当双馈电机运行在亚同步状态时,通过控制交流励磁电流可以使转子磁动势空间矢量的相位超前于定子磁动势空间矢量的相位,从而使双馈电机在转速低于同步转速时也能处于发电状态。  相似文献   

19.
Power converters play a vital role in the integration of wind power into the electrical grid. Variable-speed wind turbine generator systems have a considerable interest of application for grid connection at constant frequency. In this paper, comprehensive simulation studies are carried out with three power converter topologies: matrix, two-level and multilevel. A fractional-order control strategy is studied for the variable-speed operation of wind turbine generator systems. The studies are in order to compare power converter topologies and control strategies. The studies reveal that the multilevel converter and the proposed fractional-order control strategy enable an improvement in the power quality, in comparison with the other power converters using a classical integer-order control strategy.  相似文献   

20.
Since the blades are one of the most critical components of a wind turbine, representative samples must be experimentally tested in order to ensure that the actual performance of the blades is consistent with their specifications. In particular, it must be demonstrated that the blade can withstand both the ultimate loads and the fatigue loads to which the blade is expected to be subjected during its design service life. In general, there are basically two types of blade testing: static testing and fatigue (or dynamic) testing. This paper includes a summary review of different utility-scale wind turbine blade testing methods and the initial design study of a novel concept for tri-axial testing of large wind turbine blades. This new design is based on a blade testing method that excites the blade in flap-wise and edgewise direction simultaneously. The flap motion of the blade is caused by a dual-axis blade resonance excitation system (BREX). Edgewise motion is delivered by the use of two inclined hydraulic actuators and linear guide rail system is used to move the inclined actuators in the flap-wise direction along the blade motion. The hydraulic system and linear guide rail requirements are analyzed and an initial cost estimate of the proposed system is presented. Recommendations for future work on this proposed system are given in the final section of this work.  相似文献   