Time-of-flight mass spectrometry (TOF MS) is increasingly used in proteomics research. Herein, we report on the development and characterization of a TOF MS instrument with improved sensitivity equipped with an electrodynamic ion funnel trap (IFT) that employs an automated gain control (AGC) capability. The IFT-TOF MS was coupled to a reversed-phase capillary liquid chromatography (RPLC) separation and evaluated in experiments with complex proteolytic digests. When applied to a global tryptic digest of Shewanella oneidensis proteins, an order-of-magnitude increase in sensitivity compared to that of the conventional continuous mode of operation was achieved due to efficient ion accumulation prior to TOF MS analysis. As a result of this sensitivity improvement and related improvement in mass measurement accuracy, the number of unique peptides identified in the AGC-IFT mode was 5-fold greater than that obtained in the continuous mode.  相似文献   

2.
A new ion soft landing instrument has been built for the controlled deposition of mass selected polyatomic ions. The instrument has been operated with an electrospray ionization source; its major components are an electrodynamic ion funnel to reduce ion loss, a 90-degree bent square quadrupole that prevents deposition of fast neutral molecules onto the landing surface, and a novel rectilinear ion trap (RIT) mass analyzer. The ion trap is elongated (inner dimensions: 8 mm x 10 mm x 10 cm). Three methods of mass analysis have been implemented. (i) A conventional mass-selective instability scan with radial resonance ejection can provide a complete mass spectrum. (ii) The RIT can also be operated as a continuous rf/dc mass filter for isolation and subsequent soft landing of ions of the desired m/ z value. (iii) The 90-degree bent square quadrupole can also be used as a continuous rf/dc mass filter. The mass resolution (50% definition) of the RIT in the trapping mode (radial ion ejection) is approximately 550. Ions from various test mixtures have been mass selected and collected on fluorinated self-assembled monolayers on gold substrates, as verified by analysis of the surface rinses. Desorption electrospray ionization (DESI) has been used to confirm intact deposition of [Val (5)]-Angiotensin I on a surface. Nonmass selective currents up to 1.1 nA and mass-selected currents of up to 500 pA have been collected at the landing surface using continuous rf/dc filtering with the RIT. A quantitative analysis of rinsed surfaces showed that the overall solution-to-solution soft landing yields are between 0.2 and 0.4%. Similar experiments were performed with rf/dc isolation of both arginine and lysine from a mixture using the bent square quadrupole in the rf/dc mode. The unconventional continuous mass selection methods maximize soft landing yields, while still allowing the simple acquisition of full mass spectra.  相似文献   

3.
Methods are being developed for ultrasensitive protein characterization based upon electrospray ionization (ESI) with Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS). The sensitivity of a FTICR mass spectrometer equipped with an ESI source depends on the overall ion transmission, which combines the probability of ionization, transmission efficiency, and ion trapping in the FTICR cell. Our developments implemented in a 3.5 tesla FTICR mass spectrometer include introduction and optimization of a newly designed electrodynamic ion funnel in the ESI interface, improving the ion beam characteristics in a quadrupole-electrostatic ion guide interface, and modification of the electrostatic ion guide. These developments provide a detection limit of approximately 30 zmol (approximately 18,000 molecules) for proteins with molecular weights ranging from 8 to 20 kDa.  相似文献   

4.
When combined with capillary LC separations, electrospray ionization-Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICR MS) has demonstrated capabilities for advanced characterization of proteomes based upon analyses of proteolytic digests. Incorporation of external (to the ICR cell) multipole devices with FTICR for ion selection and ion accumulation has enhanced the dynamic range, sensitivity, and duty cycle of measurements. However, the highly variable ion production rate from an LC separation can result in "overfilling" of the external trap during the elution of major peaks and result in m/z discrimination and fragmentation of peptide ions. Excessive space charge trapped in the ICR cell also causes significant shifts in the detected ion cyclotron frequencies, reducing the achievable mass measurement accuracy (MMA) and making protein identification less effective. To eliminate m/z discrimination in the external ion trap, further increase duty cycle, and improve MMA, we have developed the capability for data-dependent adjustment of ion accumulation times in the course of an LC separation, referred to as automated gain control (AGC). This development has been implemented in combination with low kinetic energy gated ion trapping and internal calibration using a dual-channel electrodynamic ion funnel. The overall system was initially evaluated in the analysis of a tryptic digest of bovine serum albumin. In conjunction with internal calibration, the capillary LC-ESI-AGC-FTICR instrumentation provided a approximately 10-fold increase in the number of identified tryptic peptides compared to that obtained using a fixed ion accumulation time and external calibration methods.  相似文献   

5.
A nanoelectrospray ionization mass spectrometry (ESI-MS) source and interface has been designed that enables efficient ion production and transmission in a 30 Torr pressure environment using solvents compatible with typical reversed-phase liquid chromatography (RPLC) separations. In this design, the electrospray emitter is located inside the mass spectrometer in the same region as an electrodynamic ion funnel. This avoids the use of a conductance limiting ion inlet, as required by a conventional atmospheric pressure ESI source, and allows more efficient ion transmission to the mass analyzer. The new subambient pressure ionization with nanoelectrospray (SPIN) source improves instrument sensitivity and enables new electrospray interface designs, including the use of multi-emitter approaches. Performance of the SPIN source was evaluated by electrospraying standard solutions at 300 nL/min and comparing results with those obtained from a standard atmospheric pressure ESI source that used a heated capillary inlet. This initial study demonstrated an approximately 5-fold improvement in sensitivity when the SPIN source was used compared to a standard atmospheric pressure ESI source. The importance of desolvation was also investigated by electrospraying at different flow rates, which showed that the ion funnel provided an effective desolvation region to aid the creation of gas-phase analyte ions.  相似文献   

6.
The proof of principle for high-resolution analysis of intact singly charged proteins of any size is presented. Singly charged protein ions were produced by electrospray ionization followed by surface-induced charge reduction at atmospheric pressure. The inlet and trapping system "stops" the forward momentum of the protein ions over a very broad range to be captured by the digitally produced electric fields of a large radius linear ion trap whereupon they are moved into a smaller radius linear ion trap and collected and concentrated in front of its exit end-cap electrode using digital waveform manipulation. The protein ions are then ejected on demand from the end of the small radius linear quadrupole in a tightly collimated ion beam with an instrumentally defined kinetic energy into the acceleration region of an orthogonal acceleration reflectron time-of-flight mass analyzer where their flight times were measured and detected with a Photonis BiPolar TOF detector. We present results that clearly prove that massive singly charged ions can yield high-resolution mass spectra with very low chemical noise and without loss of sensitivity with increasing mass across the entire spectrum. Analysis of noncovalently bound protein complexes was demonstrated with streptavidin-Cy5 bound with a biotinylated peptide mimic. Our results suggest proteins across the entire range can be directly quantified using our mass analysis technique. We present evidence that solvent molecules noncovalently adduct onto the proteins while yielding consistent flight time distributions. Finally, we provide a look into future that will result from the ability to rapidly measure and quantify protein distributions.  相似文献   

7.
Conventional ion mobility spectrometers that sample ion packets from continuous sources have traditionally been constrained by an inherently low duty cycle. As such, ion utilization efficiencies have been limited to <1% in order to maintain instrumental resolving power. Using a modified electrodynamic ion funnel, we demonstrated the ability to accumulate, store, and eject ions in conjunction with ion mobility spectrometry (IMS), which elevated the charge density of the ion packets ejected from the ion funnel trap (IFT) and provided a considerable increase in the overall ion utilization efficiency of the IMS instrument. A 7-fold increase in signal intensity was revealed by comparing continuous ion beam current with the amplitude of the pulsed ion current in IFT-IMS experiments using a Faraday plate. Additionally, we describe the IFT operating characteristics using a time-of-flight mass spectrometer attached to the IMS drift tube.  相似文献   

8.
A triple quadrupole mass spectrometer capable of ion trapping experiments has been adapted for ion/ion reaction studies. The instrument is based on a commercially available linear ion trap (LIT) tandem mass spectrometer (i.e., an MDS SCIEX 2000 Q TRAP) that has been modified by mounting an atmospheric sampling glow discharge ionization (ASGDI) source to the side of the vacuum manifold for production of singly charged anions. The ASGDI source is located line of sight to the side of the third quadrupole of the triple quadrupole assembly (Q3). Anions are focused into the side of the rod array (i.e., anion injection occurs orthogonal to the normal ion flight path). A transmission mode method to perform ion/ion reactions has been developed whereby positive ions are transmitted through the pressurized collision quadrupole (Q2) while anions are stored in Q2. The Q2 LIT is used to trap negative ions whereas the Q3 LIT is used to accumulate positive ions transmitted from Q2. Anions are injected to Q3 and transferred to Q2, where they are stored and collisionally cooled. Multiply charged protein/peptide ions, formed by electrospray, are then mass selected by the first quadrupole assembly (Q1) operated in the rf/dc mode and injected into Q2. The positive ions, including the residual precursor ions and the product ions arising from ion/ion proton-transfer reactions, are accumulated in Q3 until they are analyzed via mass-selective axial ejection for mass analysis. The parameters that affect ion/ion reactions are discussed, including pressure, nature of the gas in Q2, and operation of Q2 as a linear accelerator. Ion/ion reactions in this mode can be readily utilized to separate ions with the same m/z but largely different mass and charge, e.g., +1 bradykinin and +16 myoglobin, in the gas phase.  相似文献   

9.
Kim T  Udseth HR  Smith RD 《Analytical chemistry》2000,72(20):5014-5019
A heated multicapillary inlet and ion funnel interface was developed to couple an electrospray ionization (ESI) source to a high-vacuum stage for obtaining improved sensitivity in mass spectrometric applications. The inlet was constructed from an array of seven thin-wall stainless steel tubes soldered into a central hole of a cylindrical heating block. An electrodynamic ion funnel was used in the interface region to more effectively capture, focus, and transmit ions from the multicapillary inlet. The interface of seven capillary inlets with the ion funnel showed more than 7 times higher transmission efficiency compared to that of a single capillary inlet with the ion funnel and a 23-fold greater transmission efficiency than could be obtained using the standard orifice-skimmer interface of a triple-quadrupole MS. The multiple-capillary inlet and ion funnel interface showed an overall 10% ion transmission efficiency and approximately 3-4% overall detection efficiency of ions from solution based (i.e., prior to electrospray). The improved performance was achieved under conditions where ESI operation is robust and results in a significant increase in dynamic range.  相似文献   

10.
Design and implementation of a new electrodynamic ion funnel   总被引:1,自引:0,他引:1  
A new electrodynamic (rf) ion funnel has been developed and evaluated for use in the interface regions (at approximately 1-10 Torr) of atmospheric pressure ion sources (e.g., electrospray ionization (ESI) for mass spectrometry). The ion funnel consists of a ring electrode ion guide with decreasing i.d. and with a superimposed dc potential gradient along the ring stack. The thicknesses of the ring electrodes and the spacings between them were reduced to 0.5 mm from 1.59 mm compared to those used for previous designs. The new ion funnel displays a significant improvement in low-mass transmission (m/z >200) and sensitivity compared to previous designs. The transmission efficiencies for electrosprayed peptides and proteins (ranging in mass from 200 to 17,000 Da) were typically 50-60% of total incoming currents from a heated capillary inlet. The transmitted ion currents were a factor of 30-56 greater than those of the standard interface for peptide samples and a factor of 18-22 greater than those for protein samples. The sensitivity gains realized at the MS detector were somewhat lower, possibly due to space charge effects in the octapole ion beam guide following the ion funnel. The improved ion transmission properties result primarily from the use of reduced spacings between ring electrodes. We also show that the ion funnel can be operated in two different modes, one using low-rf-amplitude scans, allowing fragile noncovalent complexes (as well as generally undesired adducts) to be transmitted, and the other using high-rf-amplitude scans, providing greater collisional activation and more effective adduct removal (or the dissociation of lower m/z species).  相似文献   

11.
Yue B  Lee ED  Rockwood AL  Lee ML 《Analytical chemistry》2005,77(13):4167-4175
A new electron ionization source was developed for orthogonal acceleration time-of-flight mass spectrometry (TOFMS) based on the superimposition of a magnetic field around a radio frequency-only (rf-only) ion guide. The cylindrically symmetric magnetic field compresses the electron beam from the electron source into a long narrow volume along the ion guide axis. The magnetic field also helps to maintain a narrow energy distribution of electrons that penetrate the full length of the ion guide despite the influence of the radial rf field. Ionization occurs inside the ion guide with improved efficiency resulting from efficient use of electrons, prolonged interaction time, and nontraditionally large ionization volume. At the same time, the rf field effectively focuses ions radially and confines them to the axis of the ion guide by collisional focusing, leading to high ion transmission efficiency. Furthermore, the source can also be operated in a trap-and-pulse mode to improve the ion sampling duty cycle of orthogonal acceleration TOFMS. To validate the design concept of this new ion source, a simple prototype using a single set of cylindrical rods was constructed and retrofitted to an orthogonal acceleration TOFMS. A significant increase in ion signal intensity was observed by operating the source in a pulsed ion extraction mode. Low detection limits (for example, 12 fg for toluene) were determined at 12.5 spectra s(-1) in the full spectrum mode.  相似文献   

12.
Until now, it was thought that the optimal static electromagnetic ion trap for Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry should be designed to produce a quadrupolar electrical potential, for which the ion cyclotron frequency is independent of the ion's preexcitation location within the trap. However, a quadrupolar potential results in a transverse (to the magnetic field) electric field that increases linearly with distance from the center of the trap. That radially linear electric field shifts the observed ICR frequency, increases the ICR orbital radius, and ultimately limits the highest mass-to-charge ratio ion that can be contained within the trap. In this paper, we propose a new static electromagnetic ion "trap" in which grounded screens placed just inside the usual "trapping" plates produce a good approximation to a "particle-in-a-box" potential (rather than the quadrupolar "harmonic oscillator" potential). SIMION calculations confirm that the electric potential of the screened trap is near zero almost everywhere within the trap. For our screened orthorhombic (2.5 in. X 2 in. X 2 in.) trap, the experimental ICR frequency shift due to trapping voltage is reduced by a factor of approximately 100, and the experimental variation of ICR frequency with ICR radius is reduced by a factor of approximately 10 compared to a conventional (unscreened) 2-in. cubic ion trap.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

13.
An improved electrodynamic ion funnel for ion focusing at high pressure (> 1 Torr) has been developed for a triple quadrupole mass spectrometer and its performance compared with that of an earlier prototype previously reported. The ion funnel consists of a series of ring electrodes of progressively smaller internal diameters to which rf and dc electric potentials are co-applied. The new design utilizes ring electrodes possessing larger internal diameters that taper down to a relatively larger exit aperture. In the 1-10 Torr pressure range, the new design provides significant improvement in low m/z ion transmission. Additionally, the overall ion transmission range is improved by linked scanning of the ion funnel's rf voltage concomitantly with the scanning of the quadrupole mass analyzer. Transmission of a noncovalent complex through the interface demonstrated that excessive ion heating was not problematic. Computer simulations of ion transport support the ion funnel design and help explain the relative performance of both designs. Both ion simulations and experimental results are in accord and indicate close to 100% ion transmission efficiency for electrosprayed biopolymer ions through the interface and into the mass analyzer.  相似文献   

14.
Ion mobility spectrometry-time-of-flight mass spectrometry (IMS-TOFMS) has been increasingly used in analysis of complex biological samples. A major challenge is to transform IMS-TOFMS to a high-sensitivity, high-throughput platform, for example, for proteomics applications. In this work, we have developed and integrated three advanced technologies, including efficient ion accumulation in an ion funnel trap prior to IMS separation, multiplexing (MP) of ion packet introduction into the IMS drift tube, and signal detection with an analog-to-digital converter, into the IMS-TOFMS system for the high-throughput analysis of highly complex proteolytic digests of, for example, blood plasma. To better address variable sample complexity, we have developed and rigorously evaluated a novel dynamic MP approach that ensures correlation of the analyzer performance with an ion source function and provides the improved dynamic range and sensitivity throughout the experiment. The MP IMS-TOFMS instrument has been shown to reliably detect peptides at a concentration of 1 nM in the presence of a highly complex matrix, as well as to provide a 3 orders of magnitude dynamic range and a mass measurement accuracy of better than 5 ppm. When matched against human blood plasma database, the detected IMS-TOF features were found to yield approximately 700 unique peptide identifications at a false discovery rate (FDR) of approximately 7.5%. Accounting for IMS information gave rise to a projected FDR of approximately 4%. Signal reproducibility was found to be greater than 80%, while the variations in the number of unique peptide identifications were <15%. A single sample analysis was completed in 15 min that constitutes almost 1 order of magnitude improvement compared to a more conventional LC-MS approach.  相似文献   

15.
Desorption electrospray ionization (DESI) was demonstrated as a means to couple thin-layer chromatography (TLC) with mass spectrometry. The experimental setup and its optimization are described. Development lanes were scanned by moving the TLC plate under computer control while directing the stationary DESI emitter charged droplet plume at the TLC plate surface. Mass spectral data were recorded in either selected reaction monitoring mode or in full scan ion trap mode using a hybrid triple quadrupole linear ion trap mass spectrometer. Fundamentals and practical applications of the technique were demonstrated in positive ion mode using selected reaction monitoring detection of rhodamine dyes separated on hydrophobic reversed-phase C8 plates and reversed-phase C2 plates, in negative ion full scan mode using a selection of FD&C dyes separated on a wettable reversed-phase C18 plate, and in positive ion full scan mode using a mixture of aspirin, acetaminophen, and caffeine from an over-the-counter pain medication separated on a normal-phase silica gel plate.  相似文献   

16.
The utility of ion mobility spectrometry (IMS) for separation of mixtures and structural characterization of ions has been demonstrated extensively, including in biological and nanoscience contexts. A major attraction of IMS is its speed, several orders of magnitude greater than that of condensed-phase separations. Nonetheless, IMS combined with mass spectrometry (MS) has remained a niche technique, substantially because of limited sensitivity resulting from ion losses at the IMS-MS junction. We have developed a new electrospray ionization (ESI)-IMS-QTOF MS instrument that incorporates electrodynamic ion funnels at both front ESI-IMS and rear IMS-QTOF interfaces. The front funnel is of the novel "hourglass" design that efficiently accumulates ions and pulses them into the IMS drift tube. Even for drift tubes of 2-m length, ion transmission through IMS and on to QTOF is essentially lossless across the range of ion masses relevant to most applications. The rf ion focusing at the IMS terminus does not degrade IMS resolving power, which exceeds 100 (for singly charged ions) and is close to the theoretical limit. The overall sensitivity of the present ESI-IMS-MS system is comparable to that of commercial ESI-MS, which should make IMS-MS suitable for analyses of complex mixtures with ultrahigh sensitivity and exceptional throughput.  相似文献   

17.
An electrospray ionization, dual gate, ion mobility, quadrupole ion trap mass spectrometer (ESI-DG-IM-QIT-MS) was constructed and evaluated for its ability to select mobility-filtered ions prior to mass analysis. While modification of the common signal-averaged ion mobility experiment was required, no modifications to the QIT were necessary. The dual gate scanning mode of operation was used to acquire mobility spectra, whereas the single mobility monitoring experiment selectively filtered ions for concentration and subsequent fragmentation within the QIT. Ion mobility separation of positively charged peptides and negatively charged carbohydrates, followed by MS fragmentation, was demonstrated. For a 1-min acquisition time, it was possible to obtain complete de novo sequence information for the examined peptides. Fragmentation of the negative carbohydrate chlorine adducts yielded ions characteristic of cross-ring and glycosidic bond cleavage. Previous unions of atmospheric pressure ion mobility and mass spectrometry have been limited in their ability to reproducibly obtain MSn data for mobility separation ions. The union of high-pressure ion mobility with quadrupole ion trap mass spectrometry presents the unique opportunity to obtain more detailed information regarding the chemistries of gas-phase ions.  相似文献   

18.
The coupling of Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS) with electrospray ionization has advanced the analysis of large biopolymers and provided the basis for high-throughput protein characterization (e.g., for rapid "proteome" analyses). In this work, the combination of high-performance capillary liquid chromatography with FTICR mass spectrometry and external ion accumulation has been shown to increase both sensitivity and analysis duty cycle. Instrument versatility is further improved by ion preselection followed by ion accumulation in an external linear quadrupole ion trap. The interface was tested with a 3.5-T FTICR mass spectrometer and evaluated with a number of peptides and proteins whose molecular weights ranged from 500 to 66000. A significant increase in the sensitivity, duty cycle, and dynamic range over that of the previously used accumulated trapping was achieved, exhibiting a detection limit of approximately 10 zmol (approximately 6000 molecules) for smaller proteins such as cytochrome c. Capillary LC external accumulation interface with FTICR was successfully applied for the study of whole-proteome mouse tryptic digests.  相似文献   

19.
A 2D ion trap has a greater ion trapping efficiency, greater ion capacity before observing space-charging effects, and a faster ion ejection rate than a traditional 3D ion trap mass spectrometer. These hardware improvements should result in a significant increase in protein identifications from complex mixtures analyzed using shotgun proteomics. In this study, we compare the quality and quantity of peptide identifications using data-dependent acquisition of tandem mass spectra of peptides between two commercially available ion trap mass spectrometers (an LTQ and an LCQ XP Max). We demonstrate that the increased trapping efficiency, increased ion capacity, and faster ion ejection rate of the LTQ results in greater than 5-fold more protein identifications, better identification of low-abundance proteins, and higher confidence protein identifications when compared with a LCQ XP Max.  相似文献   

20.
Zhao X  Krstic PS 《Nanotechnology》2008,19(19):195702
We found by molecular dynamics simulations that a low energy ion can be trapped effectively in a nanoscale Paul trap in both vacuum and aqueous environments when appropriate AC/DC electric fields are applied to the system. Using the negatively charged chlorine ion as an example, we show that the trapped ion oscillates around the center of the nanotrap with an amplitude dependent on the parameters of the system and applied voltages. Successful trapping of the ion within nanoseconds requires an electric bias of GHz frequency, in the range of hundreds of mV. The oscillations are damped in the aqueous environment, but polarization of water molecules requires the application of a higher voltage bias to reach improved stability of the trapping. Application of a supplemental DC driving field along the trap axis can effectively drive the ion off the trap center and out of the trap, opening up the possibility of studying DNA and other charged molecules using embedded probes while achieving a full control of their translocation and localization in the trap.  相似文献   