首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A test system with the variable displacement compressor (VDC) for automotive air conditioning system is built to study the changing rule of piston stroke length (PSL). It is found from our experiments that the critical suction pressure where the PSL starts to decrease is less than that where the PSL starts to increase for the same PSL; between the two critical lines, a hysteresis zone is formed, within which all the steady-state points fall and there is a multiple-valued relationship between VDC parameters; and the PSL is kept invariable when the VDC parameters change within the hysteresis zone. In order to find out the reason causing the hysteresis zone and to analyze the influence of the compressor parameters on the hysteresis zone, a steady-state mathematical model of VDC is developed and verified by our experimental data. The theoretical analysis indicates that the hysteresis zone is caused by the frictional forces among the moving components of VDC, and the greater the frictional forces, the broader the hysteresis zone and the larger the changing range of suction pressure. The influence of the discharge pressure and rotary speed on the hysteresis zone is that the hysteresis zone moves in the direction of the suction pressure decreasing along with the increase of the discharge pressure or rotary speed.  相似文献   

2.
A mathematical model of control mechanism used in the variable displacement swash plate compressor (VDSC) is developed firstly based on the force balance equation, mass and energy conservation equation. The model of moving components dynamics is developed then by analyzing the forces and force moments acting on the pistons and the swash plate. The compression process model is obtained by fitting the data from our experiments. And finally, the steady-state mathematical model of VDSC is developed by combining the three sub-models above. In order to verify the mathematical model, a test bench for control mechanism and the test system for VDSC have been established, and the simulated results agree well with the experimental data. The simulation results show that, like the variable displacement wobble plate compressor, there are four operation modes for the VDSC, i.e. constant rotary speed and constant piston stroke length (PSL), variable rotary speed and constant PSL, constant rotary speed and variable PSL, variable rotary speed and variable PSL, which have included almost all operation modes of the refrigeration compressor in common use. And there is a hysteresis zone and multiple-valued relationship between the compressor parameters when PSL changes.  相似文献   

3.
本文进行了直线压缩机冰箱系统的制冷实验,分析了直线压缩机运行的不稳定特性。结果表明:冰箱制冷过程中直线压缩机定频运行,会出现三种不同的不稳定状态:启动调节不稳定、外部扰动不稳定和电磁阀调节不稳定。启动过程中,供电参数的调节以及吸排气压力的变化引起的不稳定状态,随着电参数保持不变和吸排气压力趋于稳定,启动过程的不稳定现象也逐渐消失。当供电参数和制冷工况保持稳定时,制冷系统的随机扰动也会使直线压缩机产生一定的不稳定振荡,行程最大振幅约0.3 mm,电流和输入功的最大波动约为平均值的10%,直线压缩机对外部扰动具有自修复性。电磁阀调节过程对直线压缩机的稳定性影响较大,行程最大振幅约2.2 mm,压缩机存在极大的撞缸可能性。因此非常有必要结合制冷系统的运行工况,进行直线压缩机本体结构和控制系统的优化设计,保证直线压缩机在冰箱调节过程中安全可靠的运行。  相似文献   

4.
Wobble plate compressors are well used in air conditioning for high-class automobiles. They allow continuous control by automatic adjustment of the piston stroke, to keep the low pressure above a certain limit. Here an externally controlled wobble plate compressor is analyzed experimentally through its isentropic and volumetric effectivenesses and control characteristics. Compressor effectivenesses depend mainly on the compressor speed and pressure ratio: there is obtained, for example, isentropic and volumetric effectivenesses of 0.65 and 0.8 for a pressure ratio of 4 at 1000 rpm and 0.4 and 0.35 for the same pressure ratio at 4000 rpm. This degradation is attributed to the increasing of the supply pressure drop. The “lubricant” (oil + dissolved refrigerant) mass flow rate is obtained by minimization of the residuals of the thermal balances on the compressor, condenser and evaporator. Here an important oil-flow circulation is obtained: between 9.5% and 12.5% of the refrigerant flow rate. A special displacement sensor is used to measure instantaneous piston stroke and to relate it to overall compressor performance. This measurement is then compared with the results obtained with a semi-empirical model, which is able to predict, in part load, the compressor displacement. The model predicts the displacement ratio with deviations that vary between −14.5% and +8.1%.  相似文献   

5.
This paper is a part in a series that reports on the experimental study of the performance of the two-phase ejector expansion refrigeration cycle. In the present study, three two-phase ejectors are used as an expansion device in the refrigeration cycle. The effects of throat diameter of the motive nozzle, on the coefficient of performance, primary mass flow rate of the refrigerant, secondary mass flow rate of the refrigerant, recirculation ratio, average evaporator pressure, compressor pressure ratio, discharge temperature and cooling capacity, which have never before appeared in open literature, are presented. The effects of the heat sink and heat source temperatures on the system performance are also discussed.  相似文献   

6.
This paper describes a flow visualization technique that was used to evaluate qualitatively the gas flow pattern inside a small, hermetically sealed, reciprocating refrigeration compressor. The applicable compressor designs are those in which the suction gas from the evaporator is dumped into the compressor shell, and is then drawn through a muffler into the suction plenum of the compressor. The physical separation of the muffler inlet from the suction gas inlet serves to reduce compressor noise and also provides an easy and convenient means of separating any liquid (compressor oil or liquid refrigerant) from the refrigerant gas. For the flow visualization studies the compressor housing was replaced by a clear plastic shell. Atmospheric air seeded with white smoke was the working fluid. The suction inlet and muffler were parts from a commercial compressor. The flow pulsations were modelled by connecting the muffler outlet to the input plenum of an auxiliary compressor. The flow patterns near the muffler inlet were recorded with a video camera. The mixing of the inlet gas with the gas circulating inside the muffler was studied. The effect of alignment and offset of the muffler inlet relative to the suction inlet, the effect of muffler size, and the effect of a shroud around the muffler were studied. The results were used to guide a companion study of detailed temperature and pressure measurements inside a working compressor.  相似文献   

7.
An exergy method for compressor performance analysis is presented. The purpose of this is to identify and quantify defects in the use of a compressor's shaft power. This information can be used as the basis for compressor design improvements. The defects are attributed to friction, irreversible heat transfer, fluid throttling, and irreversible fluid mixing. They are described, on a common basis, as exergy destruction rates and their locations are identified. The method can be used with any type of positive displacement compressor. It is most readily applied where a detailed computer simulation program is available for the compressor. An analysis of an open reciprocating refrigeration compressor that used R12 refrigerant is given as an example. The results that are presented consist of graphs of the instantaneous rates of exergy destruction according to the mechanisms involved, a pie chart of the breakdown of the average shaft power wastage by mechanism, and a pie chart with a breakdown by location.  相似文献   

8.
A steady state simulation model has been developed to evaluate the system performance of a transcritical carbon dioxide heat pump for simultaneous heating and cooling. The simulated results are found to be in reasonable agreement with experimental results reported in the literature. Such a system is suitable, for example, in dairy plants where simultaneous cooling at 4 °C and heating at 73 °C are required. The optimal COP was found to be a function of the compressor speed, the coolant inlet temperature to the evaporator and inlet temperature of the fluid to be heated in the gas cooler and compressor discharge pressure. An optimizing study for the best allocation of the fixed total heat exchanger inventory between the evaporator and the gas cooler based on the heat exchanger area has been carried out. Effect of heat transfer in the heat exchangers on system performance has been presented as well. Finally, a novel nomogram has been developed and it is expected to offer useful guidelines for system design and its optimisation.  相似文献   

9.
A stream analysis model was developed to simulate the behavior of accumulators and their influence on the automotive air conditioning (A/C) systems. It allows a comprehensive steady state simulation with a set of input conditions such as refrigerant vapor mass flow rate and pressure at the inlet of an accumulator. In this study, the refrigerant/oil mixture is R134a/PAG oil which are totally miscible, but could be any air conditioning refrigerant/oil, including carbon dioxide (CO2)/oil. The model accounts for all major effects inside the accumulator, such as friction, bends, sudden expansion, sudden contraction and heat exchange. The outputs are vapor quality, pressure and temperature at various positions of accumulator. In order to verify the mathematical model, experiments are performed in an experimental setup made up of real size automotive air conditioning components. The simulated results agree well with the experimental data. The simulation and experimental results show an important function of accumulators that is to determine the vapor quality into compressor, and thus has influence on the performance of whole automotive A/C systems.  相似文献   

10.
This work presents two numerical models to simulate the transient and steady state behavior of a vapor compression refrigeration system. The condenser and the evaporator were divided into a number of control volumes. Time dependent partial differential equations system was obtained from the mass, energy and momentum balances for each control volume. As the expansion valve and the compressor both have very small thermal inertia, the steady state models were applied for these components. Transient and steady state models numerical predictions were compared and good agreement was found. Further simulations were performed with the objective of verifying the possibility of controlling the refrigeration system and the superheating of the refrigerant in the evaporator outlet by varying the compressor speed and the throttling valve sectional area. The results indicate that the proposed models can be used to formulate an algorithm for controlling a refrigeration system.  相似文献   

11.
A simulation model for a piston-cylinder type expansion device in which the linear motion of the piston is converted to the rotational motion of a crank via a connecting rod was developed for its use in a transcritical CO2 cycle. The model is based on lubrication theory with an assumption that the piston ring is a slippery bearing. This model has been used to verify the proper operation of the device in a prototype application and to identify the loss mechanisms of the device in the design stage. In addition, an analysis of the device has been conducted using this theoretical model for the device as installed in a prototype cycle as reported in a companion part I paper.  相似文献   

12.
A comprehensive model of a miniature-scale linear compressor for electronics cooling is presented. Linear compressors are appealing for refrigeration applications in electronics cooling. A small number of moving components translate to less theoretical frictional losses and the possibility that this technology could scale to smaller physical sizes better than conventional compressors. The model developed here incorporates all of the major components of the linear compressor including dynamics associated with the piston motion. The results of the compressor model were validated using experimental data from a prototype linear compressor. The prototype compressor has an overall displacement of approximately 3 cm3, an average stroke of 0.6 cm. The prototype compressor was custom built for this work and utilizes custom parts with the exception of the mechanical springs and the linear motor. The model results showed good agreement when validated against the experimental results. The piston stroke is predicted within 1.3% MAE. The volumetric and overall isentropic efficiencies are predicted within 24% and 31%, MAE respectively.  相似文献   

13.
For a rolling piston rotary compressor, oil supply into various lubrication elements has been analytically studied. The lubrication system, consisting of centrifugal shaft pump, radial oil feeding holes, bearings with grooves and some other sliding surfaces has been modeled by employing equivalent electric circuit network. A computer simulation program has been developed to solve the network model of the lubrication system. Its numerical solutions include total oil flow rate into the shaft inlet, oil flow rates in the main and sub journal bearings and in the eccentric bearing, and oil leakages through roller end clearances into suction and compression chambers. Validation of the numerical simulation has been made by the measurement of the total oil flow rate into the shaft. With the aid of computer simulation, parametric studies have also been carried to investigate the effects of the bearing groove shape and groove inclination angle on the bearing oil flow rates.  相似文献   

14.
15.
The purpose of this paper is to identify the minimum desorption temperatures required to operate thermally driven adsorption beds of a solid sorption refrigeration system. The method is based on the evaluation of uptake efficiency of the adsorption bed and estimating there from conditions under which the compressor ceases to provide any throughput. The difference in the densities of the refrigerant between the inlet and outlet, the adsorption characteristics of the adsorbate–refrigerant pair and the void volume in the thermal compressor are the contributors to the manifestation of the desorption state. Among them, the void volume is a controllable parameter whose role is analogous to the clearance volume in a positive displacement compressor. The methodology has been tested out with three systems, namely, silica gel + water, activated carbon fiber + ethanol and activated carbon + HFC 134a systems. It is shown that waste heat at as low as 60 °C can operate these systems which make them good energy conservation devices through recovery of low grade process waste heat.  相似文献   

16.
Research on the operation of the refrigerating machine working on the Voorhees cycle which permits two-stage compression in a single-cylinder compressor has been carried out. The purpose of this research was to study the possibilities of using the Voorhees machine in a domestic refrigerator for production of refrigeration at one or two temperature levels. The experiments were carried out on the basis of a small hermetic lubricated compressor with a low refrigerating capacity operating on a commonly used R12 and natural refrigerant isobutane R600a. The improved refrigerating capacity in the Voorhees cycle with isobutane makes the latter an alternative substitute for conventional refrigerants. Some peculiarities in the operation of a hermetic piston compressor as part of the Voorhees refrigerating machine have been revealed. They require the use of a compressor developed specially for the Voorhees cycle. The method of optimizing the cycle parameters for a one temperature refrigerating system is suggested in this paper. The research carried out proved that the optimum intermediate pressures of the Voorhees refrigerating machine producing refrigeration either at one or two temperature levels are different.  相似文献   

17.
针对一台线性压缩机,分别采用LVDT和RC负载法进行了实验研究,实验结果表明:采用RC负载法测量得到的压缩机出口(即回热器入口)PV功与LVDT测量得到的活塞端面PV功之差,占整个输入电功的5%—20%,进一步减小了线性压缩机损失。  相似文献   

18.
In a flooded evaporator of an ammonia vapor-compression refrigeration system, boiling commonly takes place with ammonia mixed with compressor lubricant and subjected to a vapor quality at the inlet of the evaporator. In the present study, flooded boiling tests of ammonia on an enhanced tube under simultaneous influence of a miscible lubricant and inlet quality were conducted. The results suggest that the boiling heat transfer coefficient increases with both saturation temperature and heat flux. The coefficient slightly increases or does not significantly vary with the inlet quality. The coefficient in general is decreased by adding lubricant to the refrigerant, but the coefficient does not necessarily decrease as the lubricant concentration increases. The lubricant effect is generally more significant than the inlet quality effect. A correlation was developed based on the present data for flooded boiling of lubricant/ammonia mixture on an enhanced horizontal tube under the influence of inlet quality.  相似文献   

19.
A capillary tube is a common expansion device widely used in small-scale refrigeration and air-conditioning systems. A generalized correlation of refrigerant mass flow rate through adiabatic capillary tubes covering both subcooled and two-phase inlet conditions is expected for multiple purposes. Based on the homogeneous equilibrium flow model, a new group of dimensionless parameters has been proposed. To express the nonlinear relationship between the mass flow rate and the associated parameters, the multi-layer perceptron neural network is employed as a universal function approximator. Simulated data from a validated homogeneous equilibrium model are used for the neural network training and testing. A 5-6-1 network trained with the simulated data of R600a and R407C shows good generality in predicting the simulated data of R12, R22, R134a, R290, R410A, and R404A. Also, the deviations between the trained neural network and the experimental data from the open literature fall into ±10%.  相似文献   

20.
CO2 is environmentally friendly, safe and more suitable to ejector refrigeration cycle than to vapor compression cycle. Supersonic two-phase flow of CO2 in the diverging sections of rectangular converging–diverging nozzles was investigated. The divergence angles with significant variation of decompression were 0.076°, 0.153°, 0.306° and 0.612°. This paper presents experimental decompression phenomena which can be used in designing nozzles and an assessment of Isentropic Homogeneous Equilibrium (IHE). Inlet conditions around 6–9 MPa, 20–37 °C were used to resemble ejector nozzles of coolers and heat pumps. For inlet temperature around 37 °C, throat decompression boiling from the saturated liquid line, supersonic decompression and IHE solution were obtained for the two large divergence angles. For divergence angles larger than 0.306°, decompression curves for inlet temperature above 35 °C approached IHE curves. For divergence angles smaller than 0.306° or for nozzles with inlet temperature below 35 °C, IHE had no solution.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号