首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 921 毫秒
1.
A quantitative analysis of critical heat flux (CHF) under high mass flux with high subcooling at atmospheric pressure was successfully carried out by applying a new transition region model for a macro-water sublayer on heated walls to the existing model of a vapor blanket over the macro-water sublayer. The CHF correlation proposed in this study could predict well the experimental data obtained for water mass flux of 940 to 20,300 kg/m2s using circulate tubes 2 to 4 mm in diameter and 30 to 100 mm in length with inlet subcooling of 30 to 90 °C and rectangular channels heated from one side with gaps of 3 to 20 mm, length of 50 to 305 mm, and inlet subcooling of 30 to 77 °C and revealed a unique feature of CHF, namely, that the effects of wall friction of subcooled boiling flow and the velocity of the steam blanket above the macro-water sublayer at atmospheric pressure become the dominant factors while they were not dominant at higher pressures. © 1997 Scripta Technica, Inc Heat Trans Jpn Res, 26 (1): 16–29, 1997  相似文献   

2.
It has been considered that dry-out occurs easily in boiling heat transfer for a small channel, a mini- or microchannel, because the channel was easily filled with coalescing vapor bubbles. In the present study, the experiments of subcooled flow boiling of water were performed under atmospheric conditions for a horizontal rectangular channel for which the size is 1 mm height and 1 mm width, with a flat heating surface of 10 mm length and 1 mm width placed on the bottom of the channel. The heating surface has a top of copper heating block and is heated by ceramic heaters. In the high heat flux region of nucleate boiling, about 70–80% of the heating surface was covered with a large coalescing bubble and the boiling reached critical heat flux as observed by high-speed video. In the beginning of transition boiling, coalescing bubbles were collapsed to many fine bubbles and microbubble emission boiling was observed at liquid subcooling higher than 30 K. The maximum heat flux obtained was 8 MW/m2 (800 W/cm2) at liquid subcooling of higher than 40 K and a liquid velocity of 0.5 m/s. However, the surface temperature was very much higher than that of a centimeter-scale channel. The high-speed video photographs indicated that microbubble emission boiling occurs in the deep transition boiling region.  相似文献   

3.
The subcooled flow boiling heat transfer characteristics of a kerosene kind hydrocarbon fuel were investigated in an electrically heated horizontal tube with an inner diameter of 1.0 mm, in the range of heat flux: 20–1500 kW/m2, fluid temperature: 25–400 °C, mass flux: 1260–2160 kg/m2 s, and pressure: 0.25–2.5 MPa. It was proposed that nucleate boiling heat transfer mechanism is dominant, as the heat transfer performance is dependent on heat flux imposed on the channel, rather than the fuel flow rate. It was found that the wall temperatures along the test section kept constant during the fully developed subcooled boiling (FDSB) of the non-azeotropic hydrocarbon fuel. After the onset of nucleate boiling, the temperature differences between inner wall and bulk fluid begin to decrease with the increase of heat flux. Experimental results show that the complicated boiling heat transfer behavior of hydrocarbon fuel is profoundly affected by the pressure and heat flux, especially by fuel subcooling. A correlation of heat transfer coefficients varying with heat fluxes and fuel subcooling was curve fitted. Excellent agreement is obtained between the predicted values and the experimental data.  相似文献   

4.
The present research is an experimental study of the effects of pressure, subcooling, and non-condensable gas (air) on the pool nucleate boiling heat transfer performance of microporous enhanced finned surfaces. The test surfaces, solid copper blocks with 1-cm2 bases and 5×5 square pin-fin arrays of 2, 4 and 8 mm fin lengths, were immersed in FC-72. The test conditions included an absolute pressure range of 30-150 kPa and a subcooling range of 0 (saturation) to 50 K. Effects of these parameters on nucleate boiling and critical heat flux (CHF) were investigated. In addition, differences between pure subcooled and gas-saturated conditions as well as horizontal and vertical base orientations were also investigated. Results showed that, in general, the effects of pressure and subcooling on both nucleate boiling and CHF were consistent with previously tested flat surface results, however, subcooling was found to significantly affect the high heat flux region of the microporous finned surfaces nucleate boiling curves. The relative enhancement of CHF from increased subcooling was greater for the microporous surface than the plain surface but less than a microporous flat surface. The horizontal orientation (horizontal base/vertical fins) was found to be slightly better than the vertical orientation (vertical base/horizontal fins). Correlations for both nucleate boiling and CHF for the microporous surfaces were also developed.  相似文献   

5.
This article presents new experimental critical heat flux results under saturated flow boiling conditions for a macro-/microscale tube. The data were obtained in a horizontal 2.20-mm inside diameter stainless-steel tube with heating lengths of 361 and 154 mm, R134a and R245fa as working fluids, mass velocities ranging from 100 to 1500 kg/m2-s, critical heat flux from 25 to 300 kW/m2, exit saturation temperatures of 25, 31, and 35°C, and critical vapor qualities ranging from 0.55 to 1. The experimental results show that critical heat flux (CHF) increases with increasing mass velocity and inlet subcooling but decreases with increasing saturation temperature and heated length. The data also indicated a higher CHF for R245fa when compared with R134a at similar conditions. The experimental data were compared against four CHF predictive methods and the results of the comparisons are reported.  相似文献   

6.
Heat transfer for flow boiling of water and critical heat flux (CHF) experiments in a half‐circumferentially heated round tube under low‐pressure conditions were carried out. To clarify the flow patterns in the heated section, experiments in the round tube under the same conditions were also carried out, and their results were compared. The experiments were conducted with atmospheric‐pressure water in test sections with inner diameter D = 6 mm, heated length L = 360 mm, inlet water subcooling ΔTin = 80 K, and mass velocity G from 0 to 2000 kg/(m2·s) for the half‐circumferentially heated round tube and from 0 to 7000 kg/(m2·s) for the full‐circumferentially heated tube. The experimental data demonstrated that the wall temperature near the outlet of the half‐circumferentially heated tube remained almost the same until CHF. It was found that burnout occurred when the flow regime changed from churn flow to annular flow, and the liquid film on the heated wall dried out although liquid film on the unheated wall remained. © 2002 Wiley Periodicals, Inc. Heat Trans Asian Res, 31(3): 149–164, 2002; Published online in Wiley InterScience ( www.interscience.wiley.com ). DOI 10.1002/htj.10022  相似文献   

7.
Heat removal of more than 10 MW/m2 in heat flux has been required in high‐heat‐generation equipment in nuclear fusion reactors. In some conditions of water subcooling and velocity, there appears an extraordinary high heat flux boiling in the transition boiling region. This boiling regime is called micro‐bubble emission boiling (MEB) because many micro‐bubbles are spouted from the heat transfer surface accompanying a huge sound. The study intent is to obtain heat transfer performance of MEB in horizontal and vertical heated surfaces to parallel flow of subcooled water, comparing with CHF of this system. Three types of MEB with different heat transfer performance and bubble behavior are observed according to the flow velocity and liquid subcooling. © 2003 Wiley Periodicals, Inc. Heat Trans Asian Res, 32(2): 130–140, 2003; Published online in Wiley InterScience ( www.interscience.wiley.com ). DOI 10.1002/htj.10077  相似文献   

8.
The characteristics of critical heat flux (CHF) in existing experiments under high subcooling and high velocity in short heated channels have, for the first time, been systematically and quantitatively investigated to provide a CHF correlation that can properly predict the effect of channel length, especially when the channel length-to-channel diameter ratio L/D is less than about 20. The major test conditions of existing CHF experiments investigated in this study were channel diameter 1 to 4 mm, L/D 1 to 25, 0.1 to 1.2 MPa pressure, 34 to 117°C inlet water subcooling and 500 to 40 700 kg/(m2 · s) mass flux in circular channels, and 3 to 20 mm gap size, 6 to 40 L/De, 0.1 to 3.1 MPa pressure, 4 to 166°C inlet water subcooling, and 940 to 27,000 kg/(m2 · s) mass flux in rectangular channels. The effect of L/D on CHF was evaluated referring to the analytical solution of CHF, which was previously derived by the author for the channel flow at high subcooling and high velocity. As a result, the effect of L/D was quantitatively clarified as an effect of magnitude in heat transfer of single-phase forced-convection flow, giving a larger CHF with a smaller L/D in the case of L/D less than about 20. The proposed correlation predicts CHF to within a ±35 percent error margin. ©1998 Scripta Technica, Heat Trans Jpn Res, 27(7): 509–521, 1998  相似文献   

9.
In this study, the coating process on the copper surface with titanium dioxide (TiO2) has been introduced. The coated surface exhibits extremely high affinity for water and the solid–liquid contact angle decreases nearly to zero by exposing the surface to ultra-violet light. This superhydrophilic characteristic was applied to nucleate boiling heat transfer of water jet impingement on a flat heated plate. By making use of this special heat transfer surface, the nucleate boiling heat transfer and the critical heat flux (CHF) of a bar water jet impingement on a large flat superhydrophilic surface was experimentally investigated. The experimental data were measured in a steady state. The purified water was employed as the working liquid. Three main influencing factors, i.e., subcooling, impact velocity and the surface coating condition, were changed and their effects on the nucleate boiling heat transfer and the CHF were investigated. The empirical correlations were obtained for predicting the CHF of steady boiling for a small round water jet impingement on a large flat superhydrophilic surface. The experimental results show that the CHF on the superhydrophilic surface is about 30% higher than that on conventional copper surface by decreasing the solid–liquid contact angle.  相似文献   

10.
Enhancements in nucleate boiling heat removal with dielectric liquids, by increasing either the bubbles nucleation sites density and/or the wetted surface area, are desirable for immersion cooling of high-power computer chips. This article presents the results of recent investigations of nucleate boiling enhancement of FC-72, HFE-7100, and PF-5060 dielectric liquids on porous graphite, copper microporous surfaces, and copper surfaces with square corner pins, 3 mm × 3 mm in cross-section and 2, 3, and 5 mm tall. All surfaces have a footprint measuring 10 × 10 mm. These investigations examined the effects of liquid subcooling up to 30 K and surface inclination, from upward-facing to downward-facing, on nucleate boiling heat transfer coefficient and critical heat flux. Natural convection of dielectric liquids for cooling chips while in the stand-by mode, at a surface average heat flux <20 kW/m2, is also investigated for the different surfaces.  相似文献   

11.
Experiments were conducted to study the subcooled flow boiling heat transfer performance of FC-72 over silicon chips. For boiling heat transfer enhancement, two kinds of micro-pin-fins having fin thickness of 50 μm and fin heights of 60 and 120 μm, respectively, were fabricated on the silicon chip surface with the dry etching technique. The fin pitch was twice the fin thickness. The experiments were conducted at the fluid velocities of 0.5, 1 and 2 m/s and the liquid subcoolings of 15, 25 and 35 K. The micro-pin-finned surfaces showed a sharp increase in heat flux with increasing wall superheat and a large heat transfer enhancement compared to a smooth surface. The nucleate flow boiling curves for the two micro-pin-finned surfaces collapsed to one line showing insensitivity to fluid velocity and subcooling, while the critical heat flux values increased with fluid velocity and subcooling. The micro-pin-finned surface with a larger fin height of 120 μm provided a better flow boiling heat transfer performance and a maximum critical heat flux of 145 W/cm2. The wall temperature at the critical heat flux for the micro-pin-finned surfaces was less than 85 °C for the reliable operation of LSI chips.  相似文献   

12.
This study experimentally investigated the critical heat flux(CHF) of departure from nucleate boiling(DNB) of water flowing under near-critical pressures in a 2 m-long vertical upward rifled tube with the size of Φ35 × 5.67 mm. Operating conditions included pressures of 18–21 MPa, mass fluxes of 475–1000 kg·m~(-2)·s~(-1), inlet subcooling temperatures of 3–5°C, and wall heat fluxes of 40–960 kW·m~(-2). Tube wall temperature distribution and heat transfer performance in different test conditions were obtained. The effects of the operating parameters on CHF were analyzed. Four heat transfer coefficient correlations were evaluated against our experimental data for further investigation of the two-phase heat transfer characteristics. A heat transfer correlation based on Martinelli number utilized in two-phase region and two empirical correlations used to predict the CHF in rifled tube at near-critical pressures were proposed. Meanwhile, experimental CHF data in rifled tube were compared with six widely used correlations and a CHF look-up table. The CHF enhancement effect in rifled tube is obvious as compared with the CHF data in smooth tube. Results show that DNB occurs at low vapor quality and subcooled region in the rifled tube at near-critical pressures. The increase in pressure leads to the early occurrence of DNB and the decrease in CHF, whereas the increase in mass flux delays the occurrence of DNB and results in the increase in CHF. DNB presents a tendency to move toward the inlet of the rifled tube. At individual operating conditions, DNB and dryout coexist at different sections of the rifled tube.  相似文献   

13.
For the purpose of cooling electronic components with high heat flux efficiently, some experiments were conducted to study the flow boiling heat transfer performance of FC-72 on silicon chips. Micro-pin-fins were fabricated on the chip surface using a dry etching technique to enhance boiling heat transfer. Three different fluid velocities (0.5, 1 and 2 m/s) and three different liquid subcoolings (15, 25 and 35 K) were performed, respectively. A smooth chip (chip S) and four micro-pin-finned chips with the same fin thickness of 30 μm and different fin heights of 60 μm (chip PF30–60) and 120 μm (chip PF30–120), respectively, were tested. All the micro-pin-finned surfaces show a considerable heat transfer enhancement compared to the smooth one, and the critical heat flux increases in the order of chip S, PF30–60 and PF30–120. For a lower ratio of fin height to fin pitch and/or higher fluid velocity, the fluid velocity has a positive effect on the nucleate boiling curves for the micro-pin-finned surfaces. At the velocities lower than 1 m/s, the micro-pin-finned surfaces show a sharp increase in heat flux with increasing wall superheat, and the wall temperature at the critical heat flux (CHF) is less than the upper limit, 85 °C, for the reliable operation of LSI chips. The CHF values for all surfaces increase with fluid velocity and subcooling. The maximum CHF can reach nearly 150 W/cm2 for chip PF30–120 at the fluid velocity of 2 m/s and the liquid subcooling of 35 K.  相似文献   

14.
This paper explores the subcooled nucleate boiling and critical heat flux (CHF) characteristics of a hybrid cooling module that combines the cooling attributes of micro-channel flow and jet impingement. A test module was constructed and tested using HFE-7100 as working fluid. Increasing the coolant’s flow rate and/or subcooling shifted both the onset of boiling (ONB) and CHF to higher heat fluxes and higher wall temperatures. The hybrid module yielded heat fluxes as high as 1127 W/cm2, which is the highest value ever achieved for a dielectric coolant at near atmospheric pressure. It is shown the hybrid cooling configuration involves complex interactions between circular jets and micro-channel flow, and unusual spatial variations of void fraction and liquid velocity. These variations are ascertained using the Developing Homogeneous Layer Model (DHLM) in which the micro-channel flow is described as consisting of a homogeneous two-phase layer along the heated wall and a bulk liquid layer. CHF is determined by a superpositioning technique that consists of dividing the heated wall into two portions, one dominated by jet impingement and the other micro-channel flow. This technique is shown to be highly effective at predicting the CHF data for the hybrid cooling configuration.  相似文献   

15.
The paper presents an experimental study of the flow-boiling heat-transfer characteristics of R12 and R134a in the annulus of a horizontal enhanced-surface-tubing evaporator. The test section has an inner-tube bore diameter of 17.5 mm, an envelope diameter of 28.6 mm and an outer smooth tube of 32.3 mm inside diameter. The ranges of heat flux and mass velocity covered in the tests were 5–25 kW/m2 and 180–290 kg/m2/s, respectively, at a pressure of 365 kPa. In order to establish the flow regime conditions at the inlet to the test section, the test rig allows for the visualization of refrigerant flow through the preheater. The experiments show two regions of heat transfer: a nucleate boiling region where the heat transfer depends mainly on heat flux, and a forced convective region where the heat transfer depends only on the refrigerant flow rate.  相似文献   

16.
An experimental study on the critical heat flux (CHF) in forced convective boiling of R142b/R22 mixtures was conducted with an electrically heated vertical test tube with 17 mm inner diameter, in which the inner surface temperature was controlled and the heated length varied from 0.058 to 0.661 m. Experiments were carried out under the following conditions: constant pressures of 1.3 and 2.0 MPa, constant mass fluxes of 1000 and 2000 kg/(m2s), and constant outlet qualities of −0.2, 0.0, and 0.1. Whole boiling curves were obtained and the effects of heated length, local quality, and mole fraction on the CHF were investigated. The CHF of mixtures was higher than that of pure fluids and showed a maximum in a CHF versus mole fraction plot at a certain mole fraction. However, the maximum was less significant for the longer test section and the higher outlet quality condition. © 1998 Scripta Technica. Heat Trans Jpn. Res., 26(5): 292–305, 1997  相似文献   

17.
This study constitutes an experimental investigation into the convective boiling heat transfer and critical heat flux (CHF) of methanol–water mixtures in a diverging microchannel with artificial cavities. Flow visualization shows that bubbles are generally nucleated at both the artificial cavities and side walls of the channel. This confirms the proper functioning of such artificial cavities. Consequently, the wall superheat of the onset nucleate boiling is significantly reduced. Experimental results show that the boiling heat transfer and CHF are significantly influenced by the molar fraction (xm) as well as the mass flux. The CHF increases with an increase in mass flux at the same molar fraction. On the other hand, the CHF increases slightly from xm = 0 to 0.3, and then decreases rapidly from xm = 0.3 to 1 at the same mass flux. The maximum CHF is reached at xm = 0.3, particularly for a mass flux of 175 kg/m2 s, due to the Marangoni effect. Flow visualization confirms that the Marangoni effect helps a region with a liquid film breakup persist to a higher heat flux, and therefore a higher CHF. Moreover, a new empirical correlation involving the Marangoni effect for the CHF on the flow boiling of methanol–water mixtures is developed. The present correlation prediction shows excellent agreement with the experimental data, and further confirms that the present correlation may predict the Marangoni effect on the CHF for the convective boiling heat transfer of binary mixtures.  相似文献   

18.
This paper presents an experimental study on the convective boiling heat transfer and the critical heat flux (CHF) of ethanol–water mixtures in a diverging microchannel with artificial cavities. The results show that the boiling heat transfer and the CHF are significantly influenced by the molar fraction (xm) as well as the mass flux. For the single-phase convection region except for the region near the onset of nucleate boiling with temperature overshoot, the single-phase heat transfer coefficient is independent of the wall superheat and increases with a decrease in the molar fraction. After boiling incipience, the two-phase heat transfer coefficient is much higher than that of single-phase convection. The two-phase heat transfer coefficient shows a maximum in the region of bubbly-elongated slug flow and deceases with a further increase in the wall superheat until approaching a condition of CHF, indicating that the heat transfer is mainly dominated by convective boiling. A flow-pattern-based empirical correlation for the two-phase heat transfer coefficient of the flow boiling of ethanol–water mixtures is developed. The overall mean absolute error of the proposed correlation is 15.5%, and more than 82.5% of the experimental data were predicted within a ±25% error band. The CHF increases from xm = 0–0.1, and then decreases rapidly from xm = 0.1–1 at a given mass flux of 175 kg/m2 s. The maximum CHF is reached at xm = 0.1 due to the Marangoni effect, indicating that small additions of ethanol into water could significantly increase the CHF. On the other hand, the CHF increases with increasing the mass flux at a given molar fraction of 0.1. Moreover, the experimental CHF results are compared with existing CHF correlations of flow boiling of the mixtures in a microchannel.  相似文献   

19.
Experiments are conducted which investigated enhancements in nucleate boiling of FC-72 dielectric liquid on porous graphite and compared results with those on a smooth copper surface of the same dimensions (10 × 10 mm). Also investigated is surface temperature excursion at boiling incipience and the obtained values of CHF are compared with those of other investigators on copper, silicon, and micro-finned silicon surfaces and micro-porous coatings. Results showed no temperature excursion at boiling incipience on porous graphite but as much as 14.0 K in saturation and 9.0-13.3 K in subcooled boiling on copper. The nucleate boiling heat transfer coefficients on porous graphite are significantly higher than on copper and the values of CHF (27.3, 39.6, 49.0, and 57.1 W/cm2 in saturation and at ΔTsub = 10, 20, and 30 K, respectively) are 63-94% higher than on copper (16.9, 21.9, 26.9, and 29.5 W/cm2, respectively). The surface superheats at CHF on porous graphite (11.0 K in saturation and 17.2-19.5 K in subcooled boiling) are lower than on copper (21.3 K and 22.9-24.9 K, respectively). The nucleate boiling heat transfer coefficient increase with subcooling and CHF increased linearly with ΔTsub. The subcooling coefficient of CHF on porous graphite (0.041) is slightly smaller than those on micro-porous coatings (0.044 and 0.049) but much higher than those on micro-finned silicon surfaces (0.022, 0.036), and on Cu, Si, and enhanced SiO2 (0.018) surfaces.  相似文献   

20.
The experimental investigation on vapor bubble growth is performed for analyzing subcooled boiling in a vertical annular channel with inner heating surface and upward water flow under atmospheric pressure. Bulk liquid mass flux ranges from 79 kg/m2s to 316 kg/m2s, and subcooling is from 40 K to 60 K. The bubble behaviors from inception to collapse are captured by High-speed photography. The performance of bubble growth recorded by the high-speed photography is given in this paper. The bubble behaviors, effect of the bubble slippage on the heat transfer, and various forces acting on the bubble are discussed.  相似文献   